ML101730212
| ML101730212 | |
| Person / Time | |
|---|---|
| Site: | Braidwood |
| Issue date: | 12/19/2005 |
| From: | Condra D Oak Ridge Institute for Science & Education |
| To: | House J Division of Nuclear Materials Safety III |
| References | |
| FOIA/PA-2010-0209, RFTA-06-001 IR-05-010 | |
| Download: ML101730212 (3) | |
Text
.4 I.
GRi S
gý OAK RIDGE INSTITUTE FOR SCIENCE AND EDUCATIr.)N December 19, 2005 Mr. John House U.S. Nuclear Regulatory Commission Region III 2443 Warrenville Road Lisle, IL 60532-4351
SUBJECT:
ANALYTICAL RESULTS FOR WATER SAMPLES NEAR THE BRAIDWOOD NUCLEAR GENERATING STATION IN BRAIDWOOD, ILLINOIS
[INSPECTION REPORT 456/457/2005-0101 (RFTA NO.06-001)
Dear Mr. House:
The Environmental Survey and Site Assessment Program (ESSAP) of the Oak Ridge Institute for Science and Education (ORISE) received water samples from December 5, 2005 through December 12, 2005 that were collected near the Braidwood Nuclear Generating Station in Braidwood, Illinois. As directed, the residence and lake samples were first analyzed for tritium (H-3) to meet your request for rush processing.
The analysis was performed by liquid scintillation (Procedure AP2, Revision 15; Procedure CP4, Revision 3). The sample identifications and collection data are presented in Table 1. The H-3 results are presented in Table 2.
The report containing the gamma spectroscopy data for selected samples and the H-3 data for the remaining samples will follow as soon as the data review process permits.
ESSAP's Quality Control (QC) requirements were met for these analyses. The QC files are available for your review upon request..
If you have any questions, please call me at (865) 241-3242 or Wade Ivey at (865) 576-9184.
Sincerely, Dale Condra Laboratory Manager Environmental Survey and Site Assessment Program RDC:WPI:db Enclosure d
cc:
T. McLaughlin, NRC/NMSS/T-7E1 8 E. Knox-Davin, NRC/NMSS/TWFN T8A23 J. Cameron, Region III File 1682 E. Abelquist, ORISE/ESSAP S. Kirk, ORISE/ESSAP G. Bonano, Region III SDstribuion approval and concurre'nce:
I Iniials Technical Management Team Member Quality Manager P. 0. BOX 117, OAK RIDGE, TENNESSEE 37831-0117 Operated by Oak Ridge Associated Universities for the U.S. Department of Energy S
ORISE TABLE I SAMPLE IDENTIFICATIONS AND COLLECTION DATA BRAIDWOOD NUCLEAR GENERATING STATION BRAIDWOOD, ILLINOIS ESSAP Sample NRC Region III Collection Collection ID Sample ID Date Time 1682W0009 NRC-9-R3 12/1/2005 NA a 1682W0010 NRC-10-R3 12/1/2005 NA 1682W0011 NRC-I l-R3 12/1/2005 NA 1682W0012 NRC-12-R3 12/5/2005 NA 1682W0013 NRC-13-R3 12/5/2005 NA 1682W0014 NRC-14-R3 12/2/2005 2:35 PM 1682W0015 NRC-15-R3 12/2/2005 2:00 PM 1682W0016 NRC-16-R3 12/3/2005 1:28 PM 1682W0024 NRC-24-R3 11/30/2005 NA 1682W0025 NRC-25-R3 11/30/2005 NA 1682W0026 NRC-26-R3 11/30/2005 NA 1682W0027 NRC-27-R3 12/6/2005 NA 1682W0028 NRC-28-R3 11/30/2005 NA 1682W0029 NRC-29-R3 11/30/2005 NA 1682W0052--
NRC-52-R3 12/7/2005 4:10 PM 1682W0053 NRC-53-R3 12/8/2005 8:30 AM 1682W0054 NRC-54-R3 12/8/2005 8:40 AM 1682W0055 NRC-55-R3 12/7/2005 NA 1682W0056 NRC-56-R3 12/7/2005 NA 1682W0057 NRC-57-R3 12/7/2005 NA 1682WO058 NRC-58-R3 12/7/2005 NA 1682W0059 NRC-59-R3 12/7/2005 NA aCollection time was not provided.
Braidwood Nuclear Generating Station o 682/Data Tables/2005-12-19 Data Tables 1682 tritium only
ib ORISE TABLE 2 CONCENTRATIONS OF TRITIUM IN WATER SAMPLES BY LIQUID SCINTILLATION ANALYSIS AP2, REVISION 15; CP4, REVISION 3 BRAIDWOOD NUCLEAR GENERATING STATION BRAIDWOOD, ILLINOIS ESSAP Sample ID NRC Region III Radionuclide Concentrations, TPUs, Sample ID and MDCsa (pCi/L) 1682W0009 NRC-9-R3 240 a
120b (200) 1682W0010 NRC-10-R3 150 120 (200) 1682W0011 NRC-1 l-R3 300
+/-
120 (200) 1682W0012 NRC-12-R3
-340 120 (200) 1682W013 NRC-13-R3 100 120 (200) 1682W0014 NRC-14-R3 210 0 120 (200) 1682W0015 NRC-15-R3 210 120 (200) 1682W0016 NRC-16-R3 1,490
+/-
140 (200) 1682W0024 NRC-24-R3 200
'+
120 (200) m 1682W0025 NRC-25-R3 180
+/-
120 (200) 1682W0026 NRC-26-R3
-250
+
120 (200) 1682W0027 NRC-27-R3 1,020
+
130 (200) 1682W0028 NRC-28-R3 2,480
+
210 (310) 1682W0029 NRC-29-R3 2,490
+
190 (280) 1682W0052 NRC-52-R3 280
+/-
120 (200) 1682W0053 NRC-53-R3 210
+
120 (200) 1682W0054 NRC-54-R3 150
+
120 (200) 1682W0055 NRC-55-R3 310
+/-
120 (200) 1682W0056 NRC-56-R3 210
+/-
120 (200) 1682W0057 NRC-57-R4 190
+/-
120 (200) 1682W0058 NRC-58-R5 170
+
120 (200) 1682W0059 NRC-59-R6 100
+/-
120 (200)
'MDCs are in parenthesis.
bUncertainties represent the 95% confidence level, based on total propagated uncertainties.
Braidwood N)jc)C3T Generating Station r 682/Data Tables/2005-12-19 Data Tables 1682 tritiurn only