ML101650276

From kanterella
Jump to navigation Jump to search
Request for Additional Information for the Review of the Columbia Generating Station, License Renewal Application - Scoping and Screening Methodology
ML101650276
Person / Time
Site: Columbia 
(NPF-021)
Issue date: 06/24/2010
From: Gettys E
License Renewal Projects Branch 1
To: Oxenford W
Energy Northwest
Gettys E, NRR/DLR, 415-4029
References
Download: ML101650276 (7)


Text

June 24, 2010 Mr. W.S. Oxenford, Vice President, Nuclear Generation and Chief Nuclear Officer Columbia Generating Station Energy Northwest MD PE08 P.O. Box 968 Richland, WA 99352

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE COLUMBIA GENERATING STATION, LICENSE RENEWAL APPLICATION -

SCOPING AND SCREENING METHODOLOGY

Dear Mr. Oxenford:

By letter dated January 19, 2010, Energy Northwest submitted an application pursuant to Title 10 of the Code of Federal Regulations Part 54 (10 CFR Part 54), to renew operating license NPF-21 for Columbia Generating Station, for review by the U.S. Nuclear Regulatory Commission (NRC or the staff). The staff is reviewing the information contained in the license renewal application and has identified, in the enclosure, areas where additional information is needed to complete the review. Further requests for additional information may be issued in the future.

Items in the enclosure were discussed with Abbas Mostala and a mutually agreeable date for the response is within 30 days from the date of this letter. If you have any questions, please contact me at 301-415-4029 or by e-mail at evelyn.gettys@nrc.gov.

Sincerely,

/RA/

Evelyn Gettys, Project Manager Projects Branch 1 Division of License Renewal Office of Nuclear Reactor Regulation Docket No. 50-397

Enclosure:

As stated cc w/encl: See next page

ML101650276 OFFICE PM:RPB1:DLR LA:DLR BC: RPB1:DLR PM:RPB1:DLR NAME EGettys IKing BPham EGettys DATE 6/21/10 6/18/10 6/22/10 6/24/10

Letter to W.S. Oxenford from Evelyn H. Gettys dated June 24, 2010

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE COLUMBIA GENERATING STATION, LICENSE RENEWAL APPLICATION -

SCOPING AND SCREENING METHODOLOGY DISTRIBUTION:

HARD COPY:

DLR RF E-MAIL:

PUBLIC RidsNrrDlr Resource RidsNrrDlrRpb1 Resource RidsNrrDlrRpb2 Resource RidsNrrDlrRarb Resource RidsNrrDlrRapb Resource RidsNrrDlrRasb Resource RidsNrrDlrRerb Resource RidsNrrDlrRpob Resource EGettys DDoyle FLyon AMostala WWalker, RIV RCohen, RIV LSubin, OGC

ENCLOSURE COLUMBIA GENERATING STATION LICENSE RENEWAL APPLICATION REQUEST FOR ADDITIONAL INFORMATION RAI 2.3.3.22-1 License renewal application (LRA) drawing LR-M515-1, shows that several yard fire hydrants and post indicator valves are out of scope (i.e., not colored in green). The staff believes that yard fire hydrants and post indicator valves have the fire protection intended functions required to be compliant with 10 CFR 50.48 as stated in 10 CFR 54.4. The fire hydrants also serve as the pressure boundary for the fire protection water supply system. Further, NUREG-0892, Safety Evaluation Report related to the operation of WPPSS Nuclear Project No. 2, dated March 1982, Section 9.5.1.6, Fire Detection and Suppression, on page 9-33, states that fire hydrants are provided on the yard main at 300-foot intervals. A hydrant hose house is provided at each hydrant with 200 feet of 2 1/2 in. hose and other equipment. A valve is provided in each hydrant lateral to facilitate hydrant maintenance and repair without interrupting flow in the underground pipe loop. The staff requests that the applicant verify whether the yard hydrants and valves are in the scope of license renewal in accordance with 10 CFR 54.4(a) and whether they are subject to an aging management review (AMR) in accordance with 10 CFR 54.21(a)(1). If they are excluded from the scope of license renewal and are not subject to an AMR, the staff requests that the applicant provide justification for the exclusion.

RAI 2.3.3.22-2 The fire protection components including jockey pump (FP-P-3), valves, piping, and fittings are not highlighted in the LRA drawing LR-M515-1 as components within the scope of license renewal and subject to an AMR. Further, NUREG-0892, Safety Evaluation Report related to the operation of WPPSS Nuclear Project No. 2, dated March 1982, Section 9.5.1.6, Fire Detection and Suppression, on page 9-33, states that a separate jockey pump, rated at 50 gpm at 100 psig, maintain[s] the yard fire main pressure at 100 to 125 psig. The staff believes that these fire protection components perform a pressure boundary intended function consistent with rest of the fire protection system in scope. The staff requests that the applicant verify whether the fire protection components listed above are in the scope of license renewal in accordance with 10 CFR 54.4(a) and whether they are subject to an AMR in accordance with 10 CFR 54.21(a)(1). If they are excluded from the scope of license renewal and are not subject to an AMR, the staff requests that the applicant provide justification for the exclusion.

RAI 2.3.3.22-3 LRA drawing LR-M515-1, shows that several fire suppression systems (Building 5, Building 6, and Building 8) are out of scope (i.e., not colored in green). The staff requests that the applicant verify whether these fire water suppression systems installed in various buildings of the plant are in the scope of license renewal in accordance with 10 CFR 54.4(a) and subject to an AMR in accordance with 10 CFR 54.21(a)(1). If they are excluded from the scope of license renewal and not subject to an AMR, the staff requests that the applicant provide justification for the exclusion.

RAI 2.3.3.22-4 LRA drawing LR-M515-4 shows that the fire suppression systems installed in the Turbine Building are out of scope (i.e., not colored in green). The staff requests that the applicant verify whether the Turbine Building fire water suppression systems are in the scope of license renewal in accordance with 10 CFR 54.4(a) and subject to an AMR in accordance with 10 CFR 54.21(a)(1). If they are excluded from the scope of license renewal and not subject to an AMR, the staff requests that the applicant provide justification for the exclusion.

RAI 2.3.3.22-5 LRA drawing LR-M573-2 show that the following fire protection components - pumps, tank, piping, valves, drains, and test connections - are out of scope (i.e., not colored in green). The staff requests that the applicant verify whether these fire protection components are in the scope of license renewal in accordance with 10 CFR 54.4(a) and subject to an AMR in accordance with 10 CFR 54.21(a)(1). If they are excluded from the scope of license renewal and not subject to an AMR, the staff requests that the applicant provide justification for the exclusion.

RAI 2.3.3.22-6 LRA Section 2.3.3.22, on page 2.3-93, states that the low pressure carbon dioxide system automatically provides fire protection for turbine generator exciter housing. A manual carbon dioxide hose station, with reel and hose, is also provided for exciter housing protection on the turbine generator floor. The automatic carbon dioxide (CO2) fire suppression system and manual CO2 hose station, with reel and hose, do not appear in LRA drawings as being in the scope of the license renewal and subject to an AMR. The staff requests that the applicant verify whether these CO2 fire suppression features are in the scope of license renewal in accordance with 10 CFR 54.4(a) and subject to an AMR in accordance with 10 CFR 54.21(a)(1). If they are excluded from the scope of license renewal and not subject to an AMR, the staff requests that the applicant provide justification for the exclusion.

RAI 2.3.3.22-7 LRA Section 2.3.3.22, on page 2.3-93, states that Halon 1301 suppression systems are installed in normally occupied areas where the application of water would be inappropriate.

Halon 1301 provides automatic fire protection for the main control room Power Generation Control Cabinet (PGCC) under the floor. Eighteen Halon 1301 system[s] are installed in various main control room PGCC sub-floor duct sections to discharge on activation of their associated thermal detector units. The eighteen main control room PGCC Halon 1301 fire suppression systems do not appear in LRA drawings as being in the scope of the license renewal and subject to an AMR. The staff requests that the applicant verify whether these Halon 1301 fire suppression systems are in the scope of license renewal in accordance with 10 CFR 54.4(a) and subject to an AMR in accordance with 10 CFR 54.21(a)(1). If they are excluded from the scope of license renewal and not subject to an AMR, the staff requests that the applicant provide justification for the exclusion.

RAI 2.3.3.22-8 LRA Section 2.3.3.22, on page 2.3-94, states that A dry chemical system is installed in approved portable hazardous material storage buildings within the plant. The system automatically actuates by melting of the fusible links or manually by a local pull station. The dry chemical fire suppression system does not appear in LRA drawings as being in the scope of the license renewal and subject to an AMR. The staff requests that the applicant verify whether the above dry chemical fire suppression system is in the scope of license renewal in accordance with 10 CFR 54.4(a) and subject to an AMR in accordance with 10 CFR 54.21(a)(1). If the system is excluded from the scope of license renewal and not subject to an AMR, the staff requests that the applicant provide justification for the exclusion.

RAI 2.3.3.22-9 Tables 2.3.3-22 and 3.3.2-22 of the LRA do not include the following fire protection components:

fire hose stations, fire hose connections, and hose racks pipe fittings, pipe supports, hangers, and couplings flow elements flow indicators strainers filter housings test connections sprinklers floor drains for fire water dikes and curbs for oil spill confinement The staff requests that the applicant verify whether the fire protection components listed above are in the scope of license renewal in accordance with 10 CFR 54.4(a) and whether they are subject to an AMR in accordance with 10 CFR 54.21(a)(1). If they are excluded from the scope of license renewal and are not subject to an AMR, the staff requests that the applicant provide justification for the exclusion.

RAI 2.4.13-1 LRA Section 2.1.2.2, Screening of Structures, provides the methodology for determining the structures and components including fire barriers within the scope of license renewal. LRA Section 2.4.13, Bulk Commodities, and Table 2.4-13 provide the results of scoping and screening of structures including fire barriers. However, scoping and screening results do not provide the type of fire barriers present in various fire areas of the plant. The staff requests that the applicant provide details of fire barrier type and material in each plant fire area within scope of license renewal in accordance with 10 CFR 54.4(a) and subject to an AMR in accordance with 10 CFR 54.21(a)(1). For any fire barrier type or material that is excluded from the scope of license renewal and is not subject to an AMR, the staff requests that the applicant provide justification for the exclusion.

Columbia Generating Station cc:

Mr. J.V. Parrish, Chief Executive Officer Energy Northwest MD 1023 P.O. Box 968 Richland, WA 99352-0968 Mr. S. K. Gambhir Energy Northwest MD PE04 P.O. Box 968 Richland, WA 99352-0968 Mr. Douglas W. Coleman, Manager, Regulatory Programs Energy Northwest P.O. Box 968 MD PE20 Richland, WA 99352-0968 Mr. William A. Horin, Esq.

Winston and Strawn 1700 K Street, NW Washington, DC 20006-3817 Chairman, Benton County Board of Commissioners P.O. Box 190 Prosser, WA 99350-0190 Mr. Richard Cowley Washington State Department of Health 111 Israel Road, SE Tumwater, WA 98504-7827 Mr. Ron Cohen U.S. Nuclear Regulatory Commission P.0. Box 69 Richland, WA 99352 Regional Administrator U.S. NRC Region IV Texas Health Resources Tower 612 E. Lamar Boulevard, Suite 400 Arlington, TX 76011-4125 EFSEC Manager Energy Facility Site Evaluation Council P.O. Box 43172 Olympia, WA 98504-3172 Mr. Abbas Mostala Energy Northwest PO Box 968 MD PE 29 Richland, WA 99352-0968