Appendix D Scenario Outline Form ES-D-1 Facility:
Turkey Point Scenario No.:
1 Op Test No.:
2007-301 Examiners:
Candidates:
US RD BOP Initial Conditions:
Mode 1 75% Power, MDL, Awaiting permission from plant management to increase power back to 100%. 3-GOP-301 in use complete through step 5.96 for retum to 100% power following a turbine valve test.
Turnover:
Equipment DOS: 3B EDG due to failed fuel pump (DOS 2 days; next 0-OSP-023.3 AU 1 & 9 in 4 hrs); B AFW Pump due to bearing failure (DOS 4 hrs; ETR 24 hrs; both trains verified operable);
3B CSP due to failed 1ST
- low discharge pressure (DOS 12 hr; ETR 36 hr)
Perform 3C ICWP isolation valve cycling test per step 7.1.3 of 3-OSP-019.3. Steps 7.1.1 & 7.1.2 for 3A and 3B ICWP are not scheduled for this shift.
Known tube leak in 3A S/G (2 gpd) unchanged for last week. Chemistry samples are being taken per 3-ONOP-071.2, Attachment 1. The current sample, just completed indicates no significant change in leak rate. MOV-3-1403 remains open at management direction due to small size and stability of tube leak rate.
Event Event Type*
Event Description No.
1 (N) SRO/BOP 30 ICWP discharge isolation valve cycling test per 3-OSP-019.3 step 7.1.3.
2 (I) RD Power range NI channel N-44 upper detector fails high. The crew responds TFN1P4AH = T TSl SRO per 3
See event 4a PT-3-1604 fails low. The crew responds per 3-ARP-097.CR for annunciator TFSIML3LT below D-7/4.
4 (C) BOP Loss of 3C 4kV bus. The crew responds per 3-ONOP-004.4. TS are TFE2Z52S = T (C TS) SRO evaluated for loss of the A SSGFWP.
4a (R) SRO/RO Automatic runback fails due to PT-3-1 604 failure and requires manual action I BOP*
to reduce power < 60 % to avoid reactor trip on s/g b-b level. The crew
responds per 3-ONOP-089.
5 TVFACN3 = 0.1 (M) ALL Once reactor power stabilized < 60% power, a 30 SG feed break occurs TFW98M=T C RO/SRO inside containment. A manual reactor trip is required before any SG level TCF1D09M = F
drops < 10% since the automatic reactor trip is failed. 3-EOP-E-0 is TFL2XASE = T performed. The MOV-3-1 409 breaker trips & FCV-3-498 fails to close leaving TFL2XBSE=T an uncontrolled feed path to 30 SG if 3A SGFP started.
6 (M) ALL C AFWP trips on overspeed prematurely at 6300 RPM (from setup). The trip TAFXSRPC
=
can not be reset. B AFWP is DOS. A AFWP starts, but runs out of steam 6300.0 pressure from the 30 feed line fault. Efforts to realign A AFWP to train 2 TCF5MTC = T steam are prevented by AFSS-3-007 stuck closed. SSGFW can not be used due to loss of 30 4kV bus and a dead battery on B SSGFWP. The crew transitions to 3-EOP-FR-H.1 when AFW flow < 345 gpm and is eventually required to initiate feed & bleed since all SGs < 32% narrow range with adverse containment conditions.
(N)ormal, (R)eactivity, (l)nstrument, (C)omponent, (M)ajor
- BOP action to either manually close CV-3-201 1 in event 3 or manually reduce load in event 4a due to automatic turbine runback failure satisfies the BOP PT-3-1 604 instrument failure manipulation.
1 Appendix D Scenario Outline Form ES-D-1 Facility:
Turkey Point Scenario No.:
1 Op Test No.:
2007-301 Examiners:
Candidates:
Mode 1, 75% Power, MOL, Awaiting permission from plant management to increase power back to 100%. 3-GOP-301 in use complete through step 5.96 for return to 100% power following a turbine valve test.
Turnover:
Equipment OOS: 3B EDG due to failed fuel pump (OOS 2 days; next 0-OSP-023.3 Att 1 & 9 in 4 hrs); B AFW Pump due to bearing failure (OOS 4 hrs; ETR 24 hrs; both trains verified operable);
3B CSP due to failed 1ST -low discharge pressure (OOS 12 hr; ETR 36 hr)
Perform 3C ICWP isolation valve cycling test per step 7.1.3 of 3-0SP-019.3. Steps 7.1.1 & 7.1.2 for 3A and 3B ICWP are not scheduled for this shift.
Known tube leak in 3A S/G (2 gpd) - unchanged for last week. Chemistry samples are being taken per 3-0NOP-071.2, Attachment 1. The current sample, just completed indicates no significant change in leak rate. MOV-3-1403 remains open at management direction due to small size and stability of tube leak rate.
Event Event Type*
Event Description No.
1 (N) SRO/BOP 3C ICWP discharge isolation valve cycling test per 3-0SP-019.3 step 7.1.3.
2 (I) RO Power range NI channel N-44 upper detector fails high. The crew responds TFN1P4AH = T per 3-0NOP-059.8.
(TS,I) SRO 3
See event 4a PT-3-1604 fails low. The crew responds per 3-ARP-097.CR for annunciator TFS1ML3L = T below 0-7/4.
4 (C) BOP Loss of 3C 4kV bus. The crew responds per 3-0NOP-004.4. TS are TFE2Z52S = T evaluated for loss of the A SSGFWP.
(C, TS) SRO 4a (R) SRO/RO Automatic runback fails due to PT-3-1604 failure and requires manual action (I) BOP*
to reduce power < 60 % to avoid reactor trip on slg 10-10 level. The crew responds per 3-0NOP-089.
5 TVFACN3 = 0.1 (M) ALL Once reactor power stabilized < 60% power, a 3C SG feed break occurs TFW98M=T (C) RO/SRO inside containment. A manual reactor trip is required before any SG level TCF1D09M = F drops < 10% since the automatic reactor trip is failed. 3-EOP-E-0 is TFL2XASE = T performed. The MOV-3-1409 breaker trips & FCV-3-498 fails to close leaving TFL2XBSE =T an uncontrolled feed path to 3C SG if 3A SGFP started.
6 (M)ALL C AFWP trips on overspeed prematurely at 6300 RPM (from setup). The trip TAFXSRPC =
can not be reset. B AFWP is OOS. A AFWP starts, but runs out of steam 6300.0 pressure from the 3C feed line fault. Efforts to realign A AFWP to train 2 TCF5MTC =T steam are prevented by AFSS-3-007 stuck closed. SSGFW can not be used due to loss of 3C 4kV bus and a dead battery on B SSGFWP. The crew transitions to 3-EOP-FR-H.1 when AFW flow < 345 gpm and is eventually required to initiate feed & bleed since all SGs < 32% narrow range with adverse containment conditions.
(N)ormal, (R)eactlvlty, (I)nstrument, (C)omponent, (M)aJor
- - BOP action to either manually close CV-3-2011 in event 3 or manually reduce load in event 4a due to automatic turbine runback failure satisfies the BOP PT-3-1604 instrument failure manipulation.
1
Appendix D Scenario Outline Form ES-D-1 Facility:
Turkey Point Scenario No.:
2 Op Test No.:
2007-301 Examiners:
Candidates:
Mode 1, 50% Power, MOL. Power on hold at 50% following inadvertent trip of 3B SGFP while investigation in progress.
Turnover:
Equipment OOS: 3B EDG due to failed fuel pump (OOS 2 days; next 0-OSP-023.3 Att 1 & 9 in 4 hrs); B AFW Pump due to bearing failure (OOS 4 hrs; ETR 24 hrs; both trains verified operable);
3B CSP due to failed 1ST
- low discharge pressure (OOS 12 hr; ETR 36 hr)
Need to swap 3D 4kV bus power supply to 3A 4kV bus per 3-OP-005 section 7.4 after shift turnover to support possible emergent maintenance on 3A COW pump (vibration increase last shift).
Known tube leak in 3A S/G (2 gpd) unchanged for last week. Chemistry samples are being taken per 3-ONOP-071.2, Attachment 1. The current sample, just completed indicates no significant change in leak rate. MOV-3-1 403 remains open at management direction due to small size and stability of tube leak rate.
Event Event Type*
Event Description No.
1 (N) SROIBOP Swap 3D 4kV bus power supply to 3A 4kV bus per 3-OP-005 section 7.4.
2 (I) BOP First stage impulse pressure channel PT-3-446 fails low. The crew responds TFS1MABL=T (TS I) SRO per 3-ONOP-028 to stop inward rod movement by taking rod control to manual and then 3-ONOP-049.1.
3 (C) ALL 1 2OVAC power panel 3P09 normal inverter fails. The auto swap to the CVT TFE6XO6F = T also fails leaving 3P09 deenergized. The crew responds per 3-ONOP-003.9.
TcE6DIlc=T 3P09 is swapped over to the spare inverter per 3-ONOP-003.9 Attachment 1.
4 TFcMM2A4 = T (C) ALL The 3A steam generator tube leak grows to 2 gpm. R-3-1 9 fails to respond.
TVI-IHSGA
=
(TS) SRO The crew responds per 3-ONOP-071.2 4a (R) ALL A fast load reduction from 50% power is initiated and performed per 3-ONOP-071.2 TVHHSGA (M) ALL The 3A steam generator tube leak grows from 2 gpm into a rupture. The
° (C) SRO/BOP reactor is tripped and 3-EOP-E-0 performed. MOV-3-1433 fails to close TFSW33CT requiring manual isolation of MSIVs.
6 (C) ALL When transition is made from 3-EOP-E-0 to 3-EOP-E-3, the startup transformer locks out. 3A EDG starts but the output breaker does not TFQ5A2OA=T automatically close, and 3-EOP-ECA-0.0 is entered. 3A EDG output breaker is manually closed and the crew transitions back to 3-EOP-E-3. Only 3A & 3D 4kV bus are now available from 3A EDG. 3-EOP-E-3 is performed to cooldown and depressurize the ROS to stop primary-secondary leak flow.
(N,iormal, (R)eactivity, (l)nstrument, (C)omponent, (M)ajor 1
Appendix 0 Scenario Outline Form ES-O-1 Facility:
Turkey Point Scenario No.:
2 Op Test No.:
2007-301 Examiners:
Candidates:
Mode 1, 50% Power, MOL. Power on hold at 50% following inadvertent trip of 3B SGFP while investigation in progress.
Turnover:
Equipment OOS: 3B EDG due to failed fuel pump (OOS 2 days; next 0-OSP-023.3 Att 1 & 9 in 4 hrs); B AFW Pump due to bearing failure (OOS 4 hrs; ETR 24 hrs; both trains verified operable);
3B CSP due to failed 1ST -low discharge pressure (OOS 12 hr; ETR 36 hr)
Need to swap 3D 4kV bus power supply to 3A 4kV bus per 3-0P-005 section 7.4 after shift turnover to support possible emergent maintenance on 3A CCW pump (vibration increase last shift).
Known tube leak in 3A S/G (2 gpd) - unchanged for last week. Chemistry samples are being taken per 3-0NOP-071.2, Attachment 1. The current sample, just completed indicates no significant change in leak rate. MOV-3-1403 remains open at management direction due to small size and stability of tube leak rate.
Event Event Type*
Event Description No.
1 (N) SRO/BOP Swap 3D 4kV bus power supply to 3A 4kV bus per 3-0P-005 section 7.4.
2 (I) BOP First stage impulse pressure channel PT-3-446 fails low. The crew responds TFS1MABL = T (TS,I) SRO per 3-0NOP-028 to stop inward rod movement by taking rod control to manual and then 3-0NOP-049.1.
3 (C) ALL 120VAC power panel 3P09 normal inverter fails. The auto swap to the CVT TFE6X06F = T also fails leaving 3P09 deenergized. The crew responds per 3-0NOP-003.9.
TCE6DI1C =T 3P09 is swapped over to the spare inverter per 3-0NOP-003.9 Attachment 1.
4 TFCMM2A4=T (C) ALL The 3A steam generator tube leak grows to 2 gpm. R-3-19 fails to respond.
TYHHSGA=
(TS) SRO The crew responds per 3-0NOP-071.2 0.002 4a (R) ALL A fast load reduction from 50% power is initiated and performed per 3-0NOP-071.2 5
TYHHSGA=
(M) ALL The 3A steam generator tube leak grows from 2 gpm into a rupture. The 0,4 (C) SRO/BOP reactor is tripped and 3-EOP-E-0 performed. MOV-3-1433 fails to close TFSW33C=T requiring manual isolation of MSIVs.
6 (C) ALL When transition is made from 3-EOP-E-0 to 3-EOP-E-3, the startup transformer locks out. 3A EDG starts but the output breaker does not TF05A20A=T automatically close, and 3-EOP-ECA-0.0 is entered. 3A EDG output breaker TA05LRSB =T is manually closed and the crew transitions back to 3-EOP-E-3. Only 3A & 3D TFP1S38S = T 4kV bus are now available from 3A EDG. 3-EOP-E-3 is performed to cooldown and depressurize the RCS to stop primary-secondary leak flow.
(N)ormal, (R)eactlvlty, (I)nstrument, (C)omponent, (M)aJor 1
Appendix D Scenario Outline Form ES-D-1 Facility:
Turkey Point Scenario No.:
3 Op Test No.:
2007-301 Examiners:
Candidates:
Mode 1, 75% Power, MOL, Awaiting permission from plant management to increase power back to 100%. 3-GOP-301 in use complete through step 5.96 for return to 100% power following a turbine valve test.
Turnover:
Equipment OOS: 3B EDG due to failed fuel pump (OOS 2 days; next 0-OSP-023.3 AU 1 & 9 in 4 hrs); B AFW Pump due to bearing failure (OOS 4 hrs; ETR 24 hrs; both trains verified operable);
3B CSP due to failed 1ST - low discharge pressure (OOS 12 hr; ETR 36 hr)
Perform monthly surveillance on 3A ECC per 3-OSP-055.1 section 7.1 immediately after shift turnover. 1ST and remote valve position verification not required.
Known tube leak in 3A S/G (2 gpd) unchanged for last week. Chemistry samples are being taken per 3-ONOP-071.2, Attachment 1. The current sample, just completed indicates no significant change in leak rate. MOV-3-1 403 remains open at management direction due to small size and stability of tube leak rate.
Event Event Type*
Event Description No.
1 (N) BOP 3A ECC monthly surveillance performed per 3-OSP-055.1 section 7.1. 3A TFKVOO5A=T (N,TS) SRO ECC inlet valve CV-3-2905 fails to open and 3A ECC is declared OOS.
2 (I) SRO/RO TM-3-408C (Tavg input to rod control) fails high. Crew responds per 3-TFL1TSCH = T ONOP-028 and takes rods to manual to stop continuous inward rod movement.
3 (C) RO/BOP Loss of 3H 480V LC. Also takes 3C charging pump, 3B ECC, 3B ECF & 3D TFE3D37A=T C TS SRO NCC OOS. Requires starting another charging pump or securing the in TFE3D38T = -r
service 60 gpm orifice. The crew responds per 3-ARP-097.CR for annunciators F-9/6, A-5/4, 1-9/3 or 1-9/4.
4 TAKPXA1=10.0 (C) SRO/BOP 3A1 Intake screen high p. Crew responds per 3-ONOP-Ol 1. 3A1 CWP is TAKPXA2 = 4.0 secured.
4a (R) ALL 3A2 Intake screen high p. Fast load reduction per 3-ONOP-100 to 60% for TAKPXA2 = 1.0 the purpose of securing 3A2 CWP. Manual rod control must be used due to rod control Tavg failure.
TAHUVBSB=22 (M) ALL 3B RCP high vibration. The crew responds per 3-ONOP-041.1. Once vibration reaches the trip setpoint the crew manually trips the reactor and TAHUVBMB=6
.immediate actions of 3-EOP-E-0 are performed.
6 (M) ALL When 3B RCP is tripped, 3B 4kV bus is lost and a large break LOCA occurs.
TFE2Z51S =T (contd from An automatic SI occurs but train A sequencer fails. Train A ECCS equipment TvHHCLB=0.1 event 5) must be manually started. The crew completes 3-EOP-E-0 and transitions to TFQ634AF = T (C) ALL applicable FRPs followed by 3-EOP-E-1.
6a Once CSFSTs are monitored for implementation, if containment pressure is still above 20 psig, the crew immediately transitions to 3-EOP-FR-Z.1 if no higher red or orange path exists.
6b (C) SROIRO 3-EOP-E-1 is entered after which 3A RHRP trips. Since neither RHRP is TFM1D3AT=T running, transition is made to 3-EOP-ECA-1.1. Measures are taken to minimize the loss of RWST inventory.
(N)ormal, (R)eactivity, (l)nstrument, (C)omponent, (M)ajor 1
Appendix 0 Scenario Outline Form ES-O-1 Facility:
Turkey Point Scenario No.:
3 Op Test No.:
2007-301 Examiners:
Candidates:
Mode 1, 75% Power, MOL, Awaiting permission from plant management to increase power back to 100%. 3-GOP-301 in use complete through step 5.96 for return to 100% power following a turbine valve test.
Turnover:
Equipment OOS: 3B EDG due to failed fuel pump (OOS 2 days; next 0-OSP-023.3 Att 1 & 9 in 4 hrs); B AFW Pump due to bearing failure (OOS 4 hrs; ETR 24 hrs; both trains verified operable);
3B CSP due to failed 1ST -low discharge pressure (OOS 12 hr; ETR 36 hr)
Perform monthly surveillance on 3A ECC per 3-0SP-055.1 section 7.1 immediately after shift turnover. 1ST and remote valve position verification not required.
Known tube leak in 3A S/G (2 gpd) - unchanged for last week. Chemistry samples are being taken per 3-0NOP-071.2, Attachment 1. The current sample, just completed indicates no significant change in leak rate. MOV-3-1403 remains open at management direction due to small size and stability of tube leak rate.
Event Event Type*
Event Description No.
1 (N) BOP 3A ECC monthly surveillance performed per 3-0SP-055.1 section 7.1. 3A TFKV905A = T ECC inlet valve CV-3-2905 fails to open and 3A ECC is declared OOS.
(N,TS) SRO 2
(I) SRO/RO TM-3-408C (Tavg input to rod control) fails high. Crew responds per 3-TFL 1T8CH = T ONOP-028 and takes rods to manual to stop continuous inward rod movement.
3 (C) RO/BOP Loss of 3H 480V LC. Also takes 3C charging pump, 3B ECC, 3B ECF & 3D TFE3D37A = T (C,TS) SRO NCC OOS. Requires starting another charging pump or securing the in TFE3D38T = T service 60 gpm orifice. The crew responds per 3-ARP-097.CR for annunciators F-9/6, A-5/4, 1-9/3 or 1-9/4.
4 TAKPXA1=10.0 (C) SRO/BOP 3A 1 Intake screen high Llp. Crew responds per 3-0NOP-011. 3A 1 CWP is TAKPXA2 = 4.0 secured.
4a (R) ALL 3A2 Intake screen high Llp. Fast load reduction per 3-0NOP-100 to 60% for TAKPXA2 = 1.0 the purpose of securing 3A2 CWP. Manual rod control must be used due to rod control Tavg failure.
5 TAHUVBSB=22 (M) ALL 3B RCP high vibration. The crew responds per 3-0NOP-041.1. Once TAHUVBMB= 6 vibration reaches the trip setpoint, the crew manually trips the reactor and immediate actions of 3-EOP-E-0 are performed.
6 (M) ALL When 3B RCP is tripped, 3B 4kV bus is lost and a large break LOCA occurs.
TFE2Z51S = T (cont'd from An automatic SI occurs but train A sequencer fails. Train A ECCS equipment TVHHCLB = 0.1 event 5) must be manually started. The crew completes 3-EOP-E-0 and transitions to TFQ634AF = T (C) ALL applicable FRPs followed by 3-EOP-E-1.
6a Once CSFSTs are monitored for implementation, if containment pressure is still above 20 psig, the crew immediately transitions to 3-EOP-FR-Z.1 if no higher red or orange path exists.
6b (C) SRO/RO 3-EOP-E-1 is entered after which 3A RHRP trips. Since neither RHRP is TFM1D3AT =T running, transition is made to 3-EOP-ECA-1.1. Measures are taken to minimize the loss of RWST inventory.
(N)ormal, (R)eactlvlty, (I)nstrument, (C)omponent, (M)aJor 1