Letter Sequence RAI |
---|
|
|
MONTHYEARML0916003362009-06-18018 June 2009 Company, Llc'S Status of Decommissioning Funding Assurance Project stage: Other ML0916003562009-06-18018 June 2009 Company, Llc'S Status of Decommissioning Funding Assurance Project stage: Other ML0916002402009-06-18018 June 2009 Company, Llc'S Status of Decommissioning Funding Assurance Project stage: Other ML0916001942009-06-18018 June 2009 Company, Llc'S Status of Decommissioning Funding Assurance Project stage: Other ML0918700662009-07-0707 July 2009 Summary of July 1, 2009, Conference Call with Exelon Generation Company, LLC, on Decommission Funding Assurance Project stage: Other RS-09-095, Decommissioning Funding Assurance Plan2009-07-29029 July 2009 Decommissioning Funding Assurance Plan Project stage: Request RS-09-111, Submittal of Clinton Power Station Site-Specific Safstor Decommissioning Cost Estimate2009-08-27027 August 2009 Submittal of Clinton Power Station Site-Specific Safstor Decommissioning Cost Estimate Project stage: Request ML0927304962009-10-0202 October 2009 RAI Decommissioning Financial Assurance Plans Project stage: RAI RS-09-145, Units 1 & 2 - Response to Request for Additional Information Regarding Decommissioning Financial Assurance Plans2009-10-27027 October 2009 Units 1 & 2 - Response to Request for Additional Information Regarding Decommissioning Financial Assurance Plans Project stage: Response to RAI RS-09-157, Submittal of Site-Specific Safstor Decommissioning Cost Estimate2009-11-16016 November 2009 Submittal of Site-Specific Safstor Decommissioning Cost Estimate Project stage: Request ML1000601672010-01-0707 January 2010 Request for Additional Information Decommissioning Financial Assurance Plans Project stage: RAI ML1001202412010-01-11011 January 2010 Submittal of Braidwood Station Site-Specific Safstor Decommissioning Cost Estimate Project stage: Request ML1001207712010-01-13013 January 2010 Correction - Braidwood Station, Units 1 and 2; Byron Station, Unit Nos. 1 and 2 - Request for Additional Information Decommissioning Financial Assurance Plans Project stage: RAI RS-10-034, Response to Request for Additional Information Regarding Decommissioning Financial Assurance Plans2010-02-15015 February 2010 Response to Request for Additional Information Regarding Decommissioning Financial Assurance Plans Project stage: Response to RAI RS-10-051, Submittal of Decommissioning Funding Assurance Calculations2010-03-10010 March 2010 Submittal of Decommissioning Funding Assurance Calculations Project stage: Request ML1011003382010-04-20020 April 2010 Request for Additional Information Regarding to Decommissioning Financial Assurance Plans (Tac Nos. ME0489, ME0490, ME0496, and ME0497) Project stage: RAI ML1014403232010-05-26026 May 2010 Request for Additional Information Regarding the Decommissioning Financial Assurance Plans Project stage: RAI ML1016803572010-06-28028 June 2010 June 2, 2010, Summary of a Telephone Conference Held with Exelon Generation Company, LLC, Regarding Decommissioning Funding Shortfalls Project stage: Other 2010-01-11
[Table View] |
|
---|
Category:Letter
MONTHYEARIR 05000456/20230042024-02-0202 February 2024 Integrated Inspection Report 05000456/2023004 and 05000457/2023004 IR 05000454/20230042024-02-0202 February 2024 Integrated Inspection Report 05000454/2023004 and 05000455/2023004 ML24025C7242024-01-29029 January 2024 Notification of NRC Baseline Inspection and Request for Information; Inspection Report 05000456/2024002; 05000457/2024002 IR 05000457/20230112024-01-25025 January 2024 2B Auxiliary Feedwater Pump Diesel Fuel Oil Dilution Report 05000457/2023011 and Preliminary Greater than Green Finding and Apparent Violation ML24022A2722024-01-23023 January 2024 Request for Information for an NRC Post-Approval Site Inspection for License Renewal Inspection Report 05000454/2024011 ML24018A0362024-01-17017 January 2024 Paragon Energy Solutions, Defect with Detroit Diesel/Mtu Fuel Injectors P/N R5229660 Cat Id 0001390618 RS-24-004, Proposed Alternative to the Distribution Requirements of ASME Code Table IWC-2411-1 for the Steam Generators2024-01-11011 January 2024 Proposed Alternative to the Distribution Requirements of ASME Code Table IWC-2411-1 for the Steam Generators ML23348A2162023-12-15015 December 2023 Exemption from Select Requirements of 10 CFR Part 73 (EPID L-2023-LLE-0030 (Security Notifications, Reports, and Recordkeeping and Suspicious Activity Reporting)) IR 05000456/20200232023-12-15015 December 2023 Baseline Security Inspection Document; 05000456/2023/402; 05000457/2023/402 ML23320A1762023-12-13013 December 2023 Exemption from Select Requirements of 10 CFR Part 73 (EPID L-2023-LLE-0027 (Security Notifications, Reports, and Recordkeeping and Suspicious Activity Reporting)) ML23277A0032023-12-11011 December 2023 Issuance of Amendments Regarding Adoption of TSTF-370 ML23339A0452023-12-0505 December 2023 Request for Information for an NRC Post-Approval Site Inspection for License Renewal Inspection Report 05000546/2024010 ML23313A1552023-12-0101 December 2023 Review of the Fall 2022 Steam Generator Tube Inspection Report ML23318A5102023-12-0101 December 2023 Relief from the Requirements of the ASME Code IR 05000454/20233012023-11-27027 November 2023 NRC Initial License Examination Report 05000454/2023301 and 05000455/2023301 ML23331A8922023-11-22022 November 2023 Supplement - Braidwood Security Rule Exemption Request ISFSI Docket No. Reference 05000457/LER-2023-001, Submittal of LER 2023-001-00 for Braidwood Station, Unit 2, Train B Auxiliary Feedwater Pump Was Inoperable Due to Degraded Oil in the Crank Case2023-11-17017 November 2023 Submittal of LER 2023-001-00 for Braidwood Station, Unit 2, Train B Auxiliary Feedwater Pump Was Inoperable Due to Degraded Oil in the Crank Case ML23321A0442023-11-17017 November 2023 Notification of Deviation from Electric Power Research Institute (EPRI) Topical Report MRP-227, Revision 1-A, Materials Reliability Program: Pressurized Water Reactor Internals Inspection and Evaluation Guideline BYRON 2023-0065, Unit 2 - Notification of Deviation from Electric Power Research Institute (EPRI) Topical Report MRP-227, Revision 1-A, Materials Reliability Program: Pressurized Water Reactor Internals Inspection and Evaluation Guideline2023-11-17017 November 2023 Unit 2 - Notification of Deviation from Electric Power Research Institute (EPRI) Topical Report MRP-227, Revision 1-A, Materials Reliability Program: Pressurized Water Reactor Internals Inspection and Evaluation Guideline BYRON 2023-0063, Day Inservice Inspection Report for Interval 4, Period 3, (B2R24)2023-11-16016 November 2023 Day Inservice Inspection Report for Interval 4, Period 3, (B2R24) IR 05000454/20230032023-11-13013 November 2023 Integrated Inspection Report 05000454/2023003 and 05000455/2023003 and Exercise of Enforcement Discretion RS-23-117, Supplemental Information Letter for Part 73 Exemption Request - Responses to Request for Confirmatory Information2023-11-10010 November 2023 Supplemental Information Letter for Part 73 Exemption Request - Responses to Request for Confirmatory Information ML23317A1192023-11-10010 November 2023 Constellation Energy Generation, LLC - 2023 Annual Report - Guarantees of Payment of Deferred Premiums RS-23-118, Supplemental Information Letter for Part 73 Exemption Request - Responses to Request for Confirmatory Information2023-11-10010 November 2023 Supplemental Information Letter for Part 73 Exemption Request - Responses to Request for Confirmatory Information ML23313A0852023-11-0909 November 2023 Submittal of 2023-301 Byron Initial License Examination Post-Examination Comments RS-23-114, Proposed Alternative for Examination of Pressurizer Circumferential and Longitudinal Shell-to-Head Welds and Nozzle-to-Vessel Welds2023-11-0101 November 2023 Proposed Alternative for Examination of Pressurizer Circumferential and Longitudinal Shell-to-Head Welds and Nozzle-to-Vessel Welds ML23297A2352023-10-26026 October 2023 Information Request for the Cyber Security Baseline Inspection, Notification to Perform Inspection IR 05000456/20234012023-10-18018 October 2023 Security Baseline Inspection Report 05000456/2023401 and 05000457/2023401 IR 05000456/20230102023-10-18018 October 2023 Functional Engineering Inspection Commercial Grade Dedication Report 05000456/2023010 and 05000457/2023010 RS-23-100, Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation2023-10-13013 October 2023 Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation RS-23-097, Constellation Energy Generation, LLC, Advisement of Leadership Changes and Submittal of Updated Standard Practice Procedures Plans2023-10-12012 October 2023 Constellation Energy Generation, LLC, Advisement of Leadership Changes and Submittal of Updated Standard Practice Procedures Plans RS-23-108, Proposed Alternative for Examinations of Examination Categories B-B, B-D, and C-A Steam Generator Pressure Retaining Welds and Full Penetration Welded Nozzles2023-10-11011 October 2023 Proposed Alternative for Examinations of Examination Categories B-B, B-D, and C-A Steam Generator Pressure Retaining Welds and Full Penetration Welded Nozzles RS-23-105, Proposed Alternative for Examinations of Examination Category C-B Steam Generator Nozzle-to-Shell Welds and Nozzle Inside Radius Sections2023-10-10010 October 2023 Proposed Alternative for Examinations of Examination Category C-B Steam Generator Nozzle-to-Shell Welds and Nozzle Inside Radius Sections ML23278A0272023-10-0505 October 2023 Operator Licensing Examination Approval - Byron Station, October 2023 RS-23-094, Relief Request I4R-24, Alternative for Post-Peening Reexamination Frequency for Reactor Pressure Vessel Head Penetration Nozzle Number 752023-09-29029 September 2023 Relief Request I4R-24, Alternative for Post-Peening Reexamination Frequency for Reactor Pressure Vessel Head Penetration Nozzle Number 75 RS-23-093, License Amendment to Braidwood Station, Units 1 and 2, and Byron Station, Units 1 and 2, Technical Specifications 3.7.15, Spent Fuel Pool Boron Concentration, 3.7.16, Spent Fuel.2023-09-29029 September 2023 License Amendment to Braidwood Station, Units 1 and 2, and Byron Station, Units 1 and 2, Technical Specifications 3.7.15, Spent Fuel Pool Boron Concentration, 3.7.16, Spent Fuel. ML23251A1622023-09-29029 September 2023 Steam Generator Tube Inspection Reports to Reflect TSTF-577 Reporting Requirements RS-23-091, Relief Request I4R-25, Alternative Requirements for Reactor Pressure Vessel Inservice Inspection Intervals2023-09-26026 September 2023 Relief Request I4R-25, Alternative Requirements for Reactor Pressure Vessel Inservice Inspection Intervals ML23226A0062023-09-19019 September 2023 Review of License Renewal Commitment Number 10 Submittal ML23180A1692023-09-11011 September 2023 Calvert Cliff Units 1 & 2, and R.E. Ginna Plant - Withdrawal of Proposed Alternatives to American Society of Mechanical Engineers (ASME) Requirements (Epids L-2022-LRR-0074, 0076, 0079, 0091, 0092, 0093 and 0094) ML23242A3282023-09-0101 September 2023 Amendment No. 233 Correction IR 05000454/20235012023-08-31031 August 2023 Emergency Preparedness Biennial Exercise Inspection Report 05000454/2023501 and 05000455/2023501 IR 05000454/20230052023-08-30030 August 2023 Updated Inspection Plan for Byron Station (Report 05000454/2023005 and 05000455/2023005) IR 05000456/20230052023-08-30030 August 2023 Updated Inspection Plan for Braidwood Station Report 05000456/2023005 and 05000457/2023005 ML23234A2462023-08-25025 August 2023 Confirmation of Initial License Examination IR 05000456/20230022023-08-0303 August 2023 Integrated Inspection Report 05000456/2023002 and 05000457/2023002 IR 05000454/20230022023-08-0303 August 2023 Integrated Inspection Report 05000454/2023002 and 05000455/2023002 2024-02-02
[Table view] Category:Request for Additional Information (RAI)
MONTHYEARML23339A0452023-12-0505 December 2023 Request for Information for an NRC Post-Approval Site Inspection for License Renewal Inspection Report 05000546/2024010 ML23297A2352023-10-26026 October 2023 Information Request for the Cyber Security Baseline Inspection, Notification to Perform Inspection ML23209A7242023-07-31031 July 2023 Request for Information on the NRC Quadrennial Comprehensive Engineering Team Inspection: Inspection Report 05000454/2024010 and 05000455/2024010 ML23198A0372023-07-17017 July 2023 Information Request to Support Upcoming Problem Identification and Resolution (PIR) Inspection at Byron Nuclear Plant ML23191A8442023-07-10010 July 2023 05000456; 05000457 Notification of an NRC Biennial Licensed Operator Requalification Program Inspection and Request for Information ML23172A1172023-06-22022 June 2023 Notification of NRC Fire Protection Team Inspection Request for Information ML23110A3202023-04-21021 April 2023 Information Request to Support the NRC Annual Baseline Emergency Action Level and Emergency Plan Changes Inspection ML23094A1352023-04-0404 April 2023 Request for Information for Nrc Commercial Grade Dedication Inspection Inspection Report 05000456/2023010 05000457/2023010 ML23069A0342023-03-0606 March 2023 Unit 1 Lr Commitment 10 RAI Set 1 - (Non-Proprietary) ML23069A0332023-03-0606 March 2023 Email to K. Lueshen Byron and Braidwood Commitment 10 - Request for Additional Information Set 1 ML23115A2412023-01-20020 January 2023 NRR E-mail Capture - Preliminary RAIs Related to L-2022-LLA-0131 - Byron, Unit 2, Reinsertion of an Accident Tolerant Fuel Lead Test Assembly ML23018A1632023-01-18018 January 2023 Notification of NRC Baseline Inspection and Request for Information ML22241A0522022-08-29029 August 2022 Notification of NRC Baseline Inspection and Request for Information Inspection Report 05000456/2022004 05000457/2022004 ML22237A0272022-08-25025 August 2022 Notification of an NRC Biennial Licensed Operator Requalification Program Inspection and Request for Information ML22271A0772022-05-0606 May 2022 NRR E-mail Capture - Final RAIs 9.1.2021 Constellation Relief Request ML22129A0132022-05-0606 May 2022 NRR E-mail Capture - Draft RAIs for Requests for Alternatives I4R-17, I4R-23, ISI-05-018, I6R-10 ML22116A1272022-04-26026 April 2022 Unit 2 RFI for an NRC Triennial Heat Exchanger/Sink Performance Inspection and RFI IR 05000454/2022002 05000455/2022002 ML22091A0852022-04-0101 April 2022 NRR E-mail Capture - Braidwood and Byron - Final RAI Regarding Proposed Alternative for Various Pressurizer Welds (EPID L-2021-LLR-0035 and 0036) ML22041B5362022-02-10010 February 2022 NRR E-mail Capture - Constellation Energy Generation, LLC - Request for Additional Information Regarding Fleet License Amendment Request to Adopt TSTF-541 ML22034A9862022-02-0404 February 2022 Information Request for the Cyber-Security Baseline Inspection, Notification to Perform Inspection 05000456/2022402 05000457/2022402 ML21350A4372021-12-16016 December 2021 Request for Information for an NRC Triennial Baseline Design Bases Assurance Inspection (Team) Inspection Report 05000456/2022010 and 05000457/2022010 ML21273A3312021-10-0404 October 2021 Information Request to Support Upcoming Biennial Problem Identification and Resolution (Pi&R) Inspection at Byron Station ML21256A1902021-09-10010 September 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Request for Additional Information Regarding License Transfer Application ML21228A2352021-08-17017 August 2021 Notification of NRC Baseline Inspection and Request for Information Inspection Report 05000457/2021004 ML21203A3112021-07-21021 July 2021 NRR E-mail Capture - Final Byron Permanently Defueled Technical Specifications (PDTS) - Second Round RAI ML21193A0942021-07-12012 July 2021 Notification of an NRC Biennial Licensed Operator Requalification Program Inspection and Request for Information ML21189A1612021-07-0808 July 2021 NRR E-mail Capture - Second Round Request for Additional Information - Byron Permanently Defueled Technical Specification Amendment ML21189A1602021-07-0808 July 2021 NRR E-mail Capture - Request for Additional Information - Braidwood, Byron, and Ginna - Amendment to Address the Issues in Westinghouse NSALs ML21144A2132021-05-24024 May 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Request for Additional Information Regarding License Transfer Application ML21117A0342021-05-0505 May 2021 Request for Additional Information Regarding Proposed Alternative to Use ASME Code Case N-893 ML21062A0652021-03-0101 March 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Request for Additional Information Regarding Proposed Fleet Alternative to Documentation Requirements for Pressure Retaining Bolting ML21057A1022021-02-25025 February 2021 Notification of NRC Fire Protection Team Inspection Request for Information; Inspection Report 05000456/2021010; 05000457/2021010 ML21049A2572021-02-18018 February 2021 Request for Additional Information Byron/Dresden Proposed Changes to Site Emergency Plans to Support Post-Shutdown and Permanently Defueled Conditions (EPID-2020-LLA-0240 & EPID-2020-LLA-0237) ML21036A1102021-02-0404 February 2021 NRR E-mail Capture - Draft RAIs for Byron Station, Unit Nos. 1 and 2, Proposed Defueled Technical Specifications and Revised License Conditions for Permanently Defueled Condition ML21029A3302021-01-29029 January 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Request for Additional Information Regarding Fleet Alternative Request to Use ASME Code Case N-885 ML21020A1292021-01-20020 January 2021 Notification of NRC Baseline Inspection and Request for Information; Inspection Report 05000456/2021002; 05000457/2021002 ML21004A1452020-12-30030 December 2020 NRR E-mail Capture - Request for Additional Information Regarding Relief Requests Braidwood I4R-11 and Byron I4R-18 ML20329A4852020-11-24024 November 2020 Notification of NRC Fire Protection Team Inspection Request for Information ML20294A5492020-10-21021 October 2020 Notification of an NRC Biennial Licensed Operator Requalification Program Inspection and Request for Information ML20289A1142020-10-0909 October 2020 NRR E-mail Capture - Preliminary RAIs for LAR Regarding Non-conservative TS EDG Frequency Tolerance ML20153A7042020-06-0101 June 2020 NRR E-mail Capture - Preliminary RAI for Fleet Request to Use Alternative OMN-26 ML20104C1452020-04-10010 April 2020 NRR E-mail Capture - Preliminary RAIs for Exelon'S April 6, 2020, Application to Defer Braidwood, Unit 2, Steam Generator Inspections ML20077M2212020-03-20020 March 2020 Ti 2515/194 Inspection Documentation Request ML20023A0812020-01-23023 January 2020 NRR E-mail Capture - RAIs for L-2019-LLA-0201 - Braidwood, Units 1 and 2, LAR to Revise TS 3.7.9, Ultimate Heat Sink ML20008D3992020-01-0808 January 2020 Notification of NRC Baseline Inspection and Request for Information; Inspection Report 05000454/2020001 ML19350B2952019-12-16016 December 2019 NRR E-mail Capture - Draft Request for Additional Information Regarding Braidwood Station, Units 1 and 2, Impractical Inservice Inspection Requirements (L-2019-LLA-0081) ML19275H1362019-10-0202 October 2019 NRR E-mail Capture - Exelon Generation Company, LLC - Request for Additional Information Regarding Request to Use ASME Code Case N-879 ML19252C1542019-08-22022 August 2019 NRR E-mail Capture - Issuance of the Remainder of Preliminary RAIs for Braidwood/Byron TSTF-505 Application ML19232A2242019-08-0707 August 2019 NRR E-mail Capture - Partial Issuance of Final RAIs for Braidwood/Byron TSTF-505 Application ML19207A0672019-07-26026 July 2019 NRR E-mail Capture - Partial Issuance of Preliminary RAIs for Braidwood/Byron TSTF-505 Application 2023-07-31
[Table view] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555*0001 May 26, 2010 Mr. Charles G. Pardee President and Chief Nuclear Officer Exelon Nuclear 4300 Winfield Road Warrenville, IL 60555
SUBJECT:
BYRON STATION, UNIT NOS. 1 AND 2. AND BRAIDWOOD STATION, UNITS 1 AND 2 - REQUEST FOR ADDITIONAL INFORMATION REGARDING THE DECOMMISSIONING FINANCIAL ASSURANCE PLANS (TAC NOS. ME0489, ME0490, ME0496, AND ME0497)
Dear Mr. Pardee:
The Nuclear Regulatory Commission (NRC) staff is continuing its review of the status of decommissioning funding at Braidwood Station (Braidwood), Units 1 and 2, and Byron Station (Byron), Unit Nos. 1 and 2. On March 31, 2009 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML090900463), Exelon Generation Company.
LLC (Exelon), submitted its "Report on Status of Decommissioning Funding for Reactors,"
pursuant to Title 10 of the Code of Federal Regulations. Section 50.75. At the request of the NRC staff, by letter dated July 29. 2009 (ADAMS Accession No. ML092220037), Exelon submitted its Decommissioning Funding Assurance Plan for. among other plants, Braidwood and Byron. The NRC staff requested additional information in letters dated October 2, 2009 (ADAMS Accession No. ML092730496), January 7 (ADAMS Accession No. ML100060167), and April 20, 2010 (ADAMS Accession No. ML101100338).
The request for additional information provided herein is related to the letter submitted by Exelon on March 10,2010 (ADAMS Accession No. ML100700098), regarding decommissioning funding assurance calculations for Braidwood and Byron. The specific information requested is addressed in the enclosure to this letter. During a discussion with your staff on May 20, 2010, it was agreed that the response to this information request and the response to the request dated April 20, 2010, can be combined into a single response due within 30 days of the date of this letter.
C. Pardee -2 The NRC staff considers that timely responses to requests for additional information help ensure sufficient time is available for staff review and contribute toward the NRC's goal of efficient and effective use of staff resources. If circumstances result in the need to revise the requested response date, please contact me at (301) 415-1055.
Sincerely,
~~~
Christopher Gratton, Senior Project Manager Plant Licensing Branch 111-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. STN 50-456, STN 50-457, STN 50-454 and STN 50-455
Enclosure:
Request for Additional Information cc w/encl: Distribution via Listserv
REQUEST FOR ADDITIONAL INFORMATION REGARDING THE DECOMMISSIONING FUNDING ASSURANCE PLAN BYRON STATION. UNIT NOS. 1 AND 2.
AND BRAIDWOOD STATION. UNITS 1 AND 2 DOCKET NOS. STN 50~454, STN 50-455.
STN 50~456 AND STN 50~457 The requests for additional information provided herein pertain to the Decommissioning Funding Assurance Plan, dated July 29, 2009 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML092220037) and supplemental submittals dated November 16,2009 (ADAMS Accession No. ML093210130), January 11, 2010 (ADAMS Accession No. ML100120241) and March 10,2010 (ADAMS Accession No. ML100700098) from Exelon Generation Company, LLC (Exelon, the licensee). Since the licensee and its management are in possession of all facts relating to a licensee's decommissioning trust funds, they are responsible for the completeness and accuracy of the information they provide under the provisions of Title 10 of the Code of Federal Regulations (10 CFR) Section 50.9.
Regulatory Basis:
Pursuant to 10 CFR Section 50.75(e)(2), the Nuclear Regulatory Commission (NRC) staff reserves the right to take the following steps in order to ensure a licensee's adequate accumulation of decommissioning funds: review, as needed, the rate of accumulation of decommissioning funds; and, either independently or in cooperation with the Federal Energy Regulatory Commission and the licensee's State Public Utility Commission, take additional actions as appropriate on a case~by~case basis, including modification of a licensee's schedule for the accumulation of decommissioning funds.
Question 1 to the March 10, 2010, submittal is a table summarizing the projected SAFSTOR cash flow for Braidwood Station (Braidwood), Units 1 and 2. Attachment 2 provides the same information for Byron Station (Byron), Units 1 and 2.
Please provide a numerical example that shows how the values in the columns titled "Radiological Decommissioning Cost less Decommissioning Period Credit," were calculated.
Provide a description of the calculation, or a formula, in sufficient detail for the NRC staff to reproduce the figures reported in the columns. Provide a computer file with an Excel spreadsheet containing the formulas used for the calculations to permit the NRC staff to verify your methods.
Enclosure
-2 Question 2 to the March 10,2010, submittal includes two tables titled "NRC Funding Assurance Calculations," for Braidwood, Units 1 and 2. Attachment 4 includes two tables with the same information for Byron, Units 1 and 2.
For Braidwood Unit 1:
Line 8 of the first table in Attachment 3 is titled:
"Total Projected Trust Fund Amount (G) = (E) + (F)"
The amount listed under the column "Braidwood Unit 1 Site-Specific SAFSTOR Decommissioning Cost Estimate," for line 8 is $600,008,000.
For Braidwood Unit 2:
Line 8 of the second table in Attachment 3 is titled:
"Total Projected Trust Fund Amount (G) = (E) + (F)"
The amount listed under the column "Braidwood Unit 2 Site-Specific SAFSTOR Decommissioning Cost Estimate," for line 8 is $660,543,000.
For Byron Unit 1:
Line 8 of the first table in Attachment 4 is titled:
=
"Total Projected Trust Fund Amount (G) (E) + (F)"
The amount listed under the column "Byron Unit 1 Site-Specific SAFSTOR Decommissioning Cost Estimate," for line 8 is $614,327,000.
For Bryon Unit 2:
Line 8 of the second table in Attachment 4 is titled:
"Total Projected Trust Fund Amount (G) = (E) + (F)"
The amount listed under the column "Byron Unit 2 Site-Specific SAFSTOR Decommissioning Cost Estimate," for line 8 is $635,618,000.
The NRC staffs independent calculations indicate that the trust amounts cannot reach the projected amounts reported above using the 2 percent earnings credit permitted under 10 CFR 50.75( e)( 1)(i), when applied to the cash flows submitted in the March 10, 2010, submittal.
Please revise the projected trust fund amounts by submitting a table showing the annual year end projected trust balance after first subtracting the annual expense from the previous year's balance and then crediting the remainder with a 2 percent annual credit. If you choose, you may provide an alternate projection, and include a numerical example and an explanation how your calculations meet the requirements of 10 CFR 50. 75( e)( 1)(i). Provide a computer file with an
- 3 Excel spreadsheet containing the formulas used for the calculations to permit the staff to verify your methods.
Question 3 to the March 10,2010, submittal includes two tables titled "NRC Funding Assurance Calculations," for Braidwood, Units 1 and 2. Attachment 4 includes two tables with the same information for Byron, Units 1 and 2.
For Braidwood, Unit 1:
Line 7 of the first table in Attachment 3 is titled:
"Decommissioning Period Earnings Credit (F)"
The amount listed under the column "Braidwood Unit 1 Site-Specific SAFSTOR Decommissioning Cost Estimate," for line 7 is $313,775,000.
For Braidwood, Unit 2:
Line 7 of the second table in Attachment 3 is titled:
"Decommissioning Period Earnings Credit (F)"
The amount listed under the column "Braidwood Unit 2 Site-Specific SAFSTOR Decommissioning Cost Estimate," for line 7 is $338,938,000.
For Byron Unit 1:
Line 7 of the first table in Attachment 4 is titled:
"Decommissioning Period Earnings Credit (F)"
The amount listed under the column "Byron Unit 1 Site-Specific SAFSTOR Decommissioning Cost Estimate," for line 7 is $307,538,000.
For Bryon Unit 2:
Line 7 of the second table in Attachment 4 is titled:
"Decommissioning Period Earnings Credit (F)"
The amount listed under the column "Byron Unit 2 Site-Specific SAFSTOR Decommissioning Cost Estimate," for line 7 is $325,716,000.
Provide a description of the calculation, or a formula, in sufficient detail for the NRC staff to reproduce the figures reported in Attachments 3 and 4 as Decommissioning Period Earnings Credit. Provide a computer file with an Excel spreadsheet containing the formulas used for the calculations to permit the NRC staff to verify your methods.
-4 Question 4 Per 10 CFR 50.75, the NRC staff determined that the amount of the decommissioning funding assurance shortfalls, rounded to the nearest million, using the trust fund balances and SAFSTOR costs included in your March 10,2010, submittal, are:
$69 million for Braidwood, Unit 1
$63 million for Braidwood, Unit 2
$87 million for Byron, Unit 2 These amounts meet the regulatory requirement of 10 CFR 50. 75( e)( 1)(i) for calculating the earnings credit using up to a 2 percent annual real rate of return during the SAFSTOR period that is specifically described in the estimate.
As a supplement to the 2009 Biennial Decommissioning Report, Exelon submitted supplemental information on March 10, 2010, including a parent company guarantee in the amount of:
$14.2 million for Braidwood, Unit 1
$10.5 million for Braidwood, Unit 2
$19.5 million for Byron, Unit 2 During a phone call on May 5,2010, your staff indicated that the above values were derived from net present value calculations. In our letter of October 2, 2009, the NRC staff informed you that 10 CFR 50.75( e)( 1))(i) does not provide for using net present value calculations to determine the amount of a potential guarantee.
Provide revised calculations of the shortfalls in decommissioning financial assurance based on your March 10,2010, fund balances and SAFSTOR expenses that are based on using up to a 2 percent annual real rate of return during a period of safe storage that is specifically described in the estimate. If your calculated amounts, do not equal or exceed the figures noted above by the staff, provide your basis for concluding that a lower amount satisfies the regulatory requirement.
Examples of calculations that the NRC staff have found to be acceptable may be found in a letter dated March 12,2009 (ADAMS Accession No. ML090760499), on pages 2-3 of the "Enclosure to the Supplement to Irradiated Fuel Management Plan and Preliminary Decommissioning Cost Estimates for Prairie Island Nuclear Generating Plant," and in a letter dated January 1, 2009 (ADAMS Accession No. ML090210156), on pages 8-9 of the "Enclosure to a Response to Requests for Additional Information for Prairie Island."
C. Pardee -2 The NRC staff considers that timely responses to requests for additional information help ensure sufficient time is available for staff review and contribute toward the NRC's goal of efficient and effective use of staff resources. If circumstances result in the need to revise the requested response date, please contact me at (301) 415-1055.
Sincerely, IRA!
Christopher Gratton, Senior Project Manager Plant Licensing Branch 111-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. STN 50-456, STN 50-457, STN 50-454 and STN 50-455
Enclosure:
Request for Additional Information cc w/encl: Distribution via Listserv DISTRIBUTION:
PUBLIC LPL3-2 RtF RidsNrrDorlLpl3-2 Resource RidsNrrPMByron Resource RidsNrrPMBraidwood Resource RidsNrrLATHarris Resource RidsOgcRp Resource RidsRgn3MailCenter Resource RidsNrrDorlDpr Resource RidsAcrsAcnw_MailCTR Resource ASimmons, NRR TFredrichs, NRR ADAMS Accession No ML101440323 *e-mail dated 5/24/10 NRR-088
- It"'r:::
LPL3-2/PM LPL3-21LA DIRS/PFPB* LPL3-2/BC NAME CGratton THarris CGratton for SCampbell RCarlson 5/25/10 5/24/10 5/26/10 DATE 5/25/10 OFFICIAL RECORD COpy