April 26, 2010 LICENSEE:
Nebraska Public Power District FACILITY:
Cooper Nuclear Station Power Plant
SUBJECT:
SUMMARY
OF TELEPHONE CONFERENCE CALL HELD ON APRIL 7, 2010, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION STAFF AND NEBRASKA PUBLIC POWER DISTRICT, RELATED TO A CLARIFICATION FOR CERTAIN RESPONSES TO REQUESTS FOR ADDITIONAL INFORMATION, FOR COOPER NUCLEAR STATION LICENSE RENEWAL The U.S. Nuclear Regulatory Commission staff and representatives of Nebraska Public Power District held a telephone conference call on April 7, 2010, to discuss clarifications for certain responses to requests for additional information for Cooper Nuclear Station license renewal.
provides a listing of the participants, and Enclosure 2 contains a brief description of the conference call.
The applicant had an opportunity to comment on this summary.
Tam Tran, Project Manager /RA/
License Renewal Projects Branch 1 Division of License Renewal Office of Nuclear Reactor Regulation Docket No. 50-298
Enclosures:
As stated cc w/encls: See next page
ML101040872 OFFICE LA:DLR PM:RPB1:DLR BC:RPB1:DLR PM:RPB1:DLR NAME SFigueroa TTran BPham TTran DATE 04/15/10 04/15/10 04/26/10 04/26/10
ENCLOSURE 1 LIST OF PARTICIPANTS FROM THE TELEPHONE CONFERENCE CALL FOR COOPER NUCLEAR STATION LICENSE RENEWAL APPLICATION April 7, 2010 PARTICIPANTS AFFILIATIONS T. Tran U.S. Nuclear Regulatory Commission (NRC)
B. Pham NRC O. Yee NRC A. Hiser NRC D. Bremer Nebraska Public Power District (NPPD)
W. Victor NPPD K. Thomas NPPD T. McClure NPPD S. Freborg NPPD D. Lach, Entergy A. Cox Entergy T. Ivy Entergy
ENCLOSURE 2 COOPER NUCLEAR STATION POWER PLANT LICENSE RENEWAL APPLICATION (Brief description of the conference call)
The U.S. Nuclear Regulatory Commission (NRC) staff and representatives of NPPD held a telephone conference call on April 7, 2010, to discuss clarifications for a certain confirmatory item in the SER with Open Items for Cooper Nuclear Station license renewal.
Clarification for RAI 4.3.1-11(c) Response In its response to RAI 4.3.1-11(c), dated August 13, 2009, the applicant indicated that the Fen (environmental assisted correction factor) for alloy 600 was calculated in accordance with the method described in NUREG/CR 6335, which includes specific information for alloy 600.
However, the staff noted that NUREG/CR 6909 also provides equations for determining the Fen factor for nickel alloy components (alloy 600). The staff further noted that the use of these equations can result in an Fen factor that range approximately between 1.0 and 4.5 depending on temperature, strain rate, and water chemistry. The staff finds that the use of NUREG/CR 6335 may not be as conservative in calculating the Fen factor for nickel alloy components when compared to NUREG/CR 6909, which is based on more recent data and information.
The applicant agreed to submit additional information regarding its intention to use NUREG/CR 6335 or NUREG/CR 6909.
Letter to NPPD from T. Tran dated April 26, 2010
SUBJECT:
SUMMARY
OF TELEPHONE CONFERENCE CALL HELD ON APRIL 7, 2010, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION STAFF AND NEBRASKA PUBLIC POWER DISTRICT, RELATED TO A CLARIFICATION FOR CERTAIN RESPONSES TO REQUESTS FOR ADDITIONAL INFORMATION, FOR COOPER NUCLEAR STATION LICENSE RENEWAL DISTRIBUTION:
HARD COPY:
DLR RF E-MAIL:
PUBLIC RidsNrrDlr Resource RidsNrrDlrRpb1 Resource RidsNrrDlrRpb2 Resource RidsNrrDlrRarb Resource RidsNrrDlrRasb Resource RidsNrrDlrRapb Resource RidsNrrDlrRerb Resource RidsNrrDlrRpob Resource RidsNrrDciCvib Resource RidsNrrDciCpnb Resource RidsNrrDciCsgb Resource RidsNrrDraAfpb Resource RidsNrrDraApla Resource RidsNrrDeEmcb Resource RidsNrrDeEeeb Resource RidsNrrDssSrxb Resource RidsNrrDssSbpb Resource RidsNrrDssScvb Resource RidsOgcMailCenter Resource T. Tran B. Brady F. Lyon I. Couret, OPA D. Roth, OGC A. Jones, OGC N. Taylor, RIV E. Collins, RIV C. Casto, RIV B. Maier, RIV V. Dricks, RIV D. Chamberlain, RIV A. Vegel, RIV W. Walker, RIV G. Miller, RIV G. Pick, RIV
Cooper Nuclear Station cc:
Mr. Ronald D. Asche President and Chief Executive Officer Nebraska Public Power District 1414 15th Street Columbus, NE 68601 Mr. Gene Mace Nuclear Asset Manager Nebraska Public Power District P.O. Box 98 Brownville, NE 68321 Mr. John C. McClure Vice President and General Counsel Nebraska Public Power District P.O. Box 499 Columbus, NE 68602-0499 Mr. David Van Der Kamp Licensing Manager Nebraska Public Power District P.O. Box 98 Brownville, NE 68321 Mr. Michael J. Linder, Director Nebraska Department of Environmental Quality P.O. Box 98922 Lincoln, NE 68509-8922 Chairman Nemaha County Board of Commissioners Nemaha County Courthouse 1824 N Street Auburn, NE 68305 Ms. Julia Schmitt, Manager Radiation Control Program Nebraska Health & Human Services R&L Public Health Assurance 301 Centennial Mall, South P.O. Box 95007 Lincoln, NE 68509-5007 Deputy Director for Policy Missouri Department of Natural Resources P.O. Box 176 Jefferson City, MO 65102-0176 Senior Resident Inspector U.S. Nuclear Regulatory Commission P.O. Box 218 Brownville, NE 68321 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 612 E. Lamar Blvd., Suite 400 Arlington, TX 76011-4125 Director, Missouri State Emergency Management Agency P.O. Box 116 Jefferson City, MO 65102-0116 Chief, Radiation and Asbestos Control Section Kansas Department of Health and Environment Bureau of Air and Radiation 1000 SW Jackson, Suite 310 Topeka, KS 66612-1366 Ms. Melanie Rasmussen Radiation Control Program Director Bureau of Radiological Health Iowa Department of Public Health Lucas State Office Building, 5th Floor 321 East 12th Street Des Moines, IA 50319 Mr. Keith G. Henke, Planner Division of Community and Public Health Office of Emergency Coordination 930 Wildwood Drive P.O. Box 570 Jefferson City, MO 65102
Cooper Nuclear Station cc:
Mr. Art Zaremba, Director of Nuclear Safety Assurance Nebraska Public Power District P.O. Box 98 Brownville, NE 68321 Mr. John F. McCann, Director Licensing, Entergy Nuclear Northeast Entergy Nuclear Operations, Inc.
440 Hamilton Avenue White Plains, NY 10601-1813 Mr. Mike Boyce Cooper Strategic Initiatives Manager Cooper Nuclear Station 72676 - 648A Avenue Brownville, NE 68321 Mr. Dave Bremer License Renewal Project Manager Cooper Nuclear Station 72676 - 648A Avenue Brownville, NE 68321 Mr. Bill Victor License Renewal Project Licensing Lead Cooper Nuclear Station 72676 - 648A Avenue Brownville, NE 68321 Mr. Garry Young License Renewal Manager Entergy Nuclear 1448 S.R. 333, N-GSB-45 Russellville, AR 72802 Mr. Alan Cox License Renewal Technical Manager Entergy Nuclear 1448 S.R. 333, N-GSB-45 Russellville, AR 72802 Mr. Dave Lach LRP Entergy Project Manager Entergy Nuclear 1448 S.R. 333, N-GSB-45 Russellville, AR 72802