P.O. Box 63 C:EN G Lycoming, NY 13093 a joint venture of 0

c Cnstelation ney".IeDF NINE MILE POINT NUCLEAR STATION January 28, 2010 U. S. Nuclear Regulatory Commission Washington, DC 20555-0001 Attention:

Document Control Desk

Subject:

Nine Mile Point Nuclear Station, LLC Unit Nos. 1 and 2; Docket Nos. 50-220 and 50-4 10 10 CFR 50.46 ECCS Evaluation Model Annual Reports for 2009 Pursuant to the reporting requirements of 10 CFR 50.46(a)(3)(ii), Nine Mile Point Nuclear Station, LLC (NMPNS) is submitting the Emergency Core Cooling System (ECCS) evaluation model annual reports for Nine Mile Point Unit 1 (NMP1) and Nine Mile Point Unit 2 (NMP2).

These annual reports, provided in Attachments 1 and 2, summarize the nature of and estimated effect of any changes or errors in the ECCS models for NMP1 and NMP2 for the period January 1, 2009 through December 31, 2009.

Should you have any questions regarding this submittal, please contact T. F. Syrell, Licensing Director, at (315) 349-5219.

Very truly yours,

?.Pacher M

ager, Engineering Services JEP/RJC A-00

Document Control Desk January 28, 2010 Page 2 Attachments:

1. Nine Mile Point Unit 110 CFR 50.46 ECCS Evaluation Model Annual Report for 2009
2. Nine Mile Point Unit 2 10 CFR 50.46 ECCS Evaluation Model Annual Report for 2009 cc:

NRC Regional Administrator, Region I NRC Resident Inspector NRC Project Manager

ATTACHMENT 1 NINE MILE POINT UNIT 1 10 CFR 50.46 ECCS EVALUATION MODEL ANNUAL REPORT FOR 2009 Nine Mile Point Nuclear Station, LLC January 28, 2010

ATTACHMENT 1 NINE MILE POINT UNIT 1 10 CFR 50.46 ECCS EVALUATION MODEL ANNUAL REPORT FOR 2009 BACKGROUND In accordance with 10 CFR 50.46(a)(3)(ii), this annual report summarizes the nature of and estimated effect of any changes or errors in the Emergency Core Cooling System (ECCS) model for the period January 1, 2009 through December 31, 2009 for Nine Mile Point Unit 1 (NMP1).

DISCUSSION No changes or errors to the ECCS evaluation model were identified in 2009 for NMP 1.

IMPACT Not applicable CONCLUSION As documented in Table 1, the NMP1 Loss of Coolant Accident analysis Peak Clad Temperature (PCT) remains in compliance with 10 CFR 50.46(b)(1), which requires that the PCT shall not exceed 2200 'F.

1 of 2

ATTACHMENT 1 NINE MILE POINT UNIT 1 10 CFR 50.46 ECCS EVALUATION MODEL ANNUAL REPORT FOR 2009 Table 1 LOCA Margin Summary Sheet Nine Mile Point Nuclear Station, LLC Nine Mile Point Unit 1 Evaluation Model:

General Electric SAFER / CORCL / GESTR methodology Net PCT Effect Absolute PCT Effect A. Prior 10 CFR 50.46 Changes or Error Corrections -

Previous Years B. Prior 10 CFR 50.46 Changes or Error Corrections -

This Year Absolute Sum of 10 CFR 50.46 Changes APCT =

0 OF APCT =

0 OF APCT =

0 OF 0 OF 0 OF The sum of the PCT from the most recent analysis using an acceptable evaluation model and the estimates of PCT impact for changes and errors identified since this analysis is less than 2200 degrees F.

2 of 2

ATTACHMENT 2 NINE MILE POINT UNIT 2 10 CFR 50.46 ECCS EVALUATION MODEL ANNUAL REPORT FOR 2009 Nine Mile Point Nuclear Station, LLC January 28, 2010

ATTACHMENT 2 NINE MILE POINT UNIT 2 10 CFR 50.46 ECCS EVALUATION MODEL ANNUAL REPORT FOR 2009 BACKGROUND In accordance with 10 CFR 50.46(a)(3)(ii), this annual report summarizes the nature of and estimated effect of any changes or errors in the Emergency Core Cooling System (ECCS) model for the period January 1, 2009 through December 31, 2009 for Nine Mile Point Unit 2 (NMP2).

DISCUSSION No changes or errors to the ECCS evaluation model were identified in 2009 for NMP2.

IMPACT Not applicable CONCLUSION As documented in Table 1, the NMP2 Loss of Coolant Accident analysis Peak Clad Temperature (PCT) remains in compliance with 10 CFR 50.46(b)(1), which requires that the PCT shall not exceed 2200 °F.

1 of 2

ATTACHMENT 2 NINE MILE POINT UNIT 2 10 CFR 50.46 ECCS EVALUATION MODEL ANNUAL REPORT FOR 2009 Table 1 LOCA Margin Summary Sheet Nine Mile Point Nuclear Station Nine Mile Point Unit 2 Evaluation Model:

General Electric SAFER / GESTR - LOCA methodology Net PCT Effect Absolute PCT Effect A. Prior 10 CFR 50.46 Changes or Error Corrections - APCT =

Previous Years B. Prior 10 CFR 50.46 Changes or Error Corrections - APCT This Year 0 OF 0 OF 0 OF 0 0 F 0 OF Absolute Sum of 10 CFR 50.46 Changes APCT =

The sum of the PCT from the most recent analysis using an acceptable evaluation model and the estimates of PCT impact for changes and errors identified since this analysis is less than 2200 degrees F.

2 of2