ML093431063

From kanterella
Jump to navigation Jump to search
Forwards Nonproprietary Indian Point Unit 3 Steam Generator Sleeving Rept, & Westinghouse Authorization CAW-82-62. Submittal Supercedes 821018 Authorization CAW-82-50
ML093431063
Person / Time
Site: Indian Point 
Issue date: 12/06/1982
From: Bayne J
Power Authority of the State of New York
To: Varga S
Office of Nuclear Reactor Regulation
Shared Package
ML093431064 List:
References
IPN-82-79, NUDOCS 8212270259
Download: ML093431063 (2)


Text

POWER AUTHORITY OF THE STATE OF NEW YORK 10 COLUMBUS CIRCLE NEW YORK. N. Y. 10019 (212) 397.6200 LEROY W. SINCLAIR PRESIDENT &

CHIEF TRUSTEES OPERATING OFFICER IJOHN S. DYSON WALTER T. KICINSKI FIRST EXECUTIVE CHAIRMAN

,VICE PRESIDENT &

CHIEF ADMINISTRATIVE GEORGE L. INGALLS OFFICER VICE CHAIRMAN JOSEPH R. SCHMIEDER EXECUTIVE VICE PRESIDENT &

CHIEF RICHARD M. FLYNN ENGINEER ROBERT I. MILLONZI December 6, 1982 STEPHEN L. BAUM SENIOR VICE PRESIDENT JAMES L. LAROCCA IPN-82-79

& GENERAL COUNSEL Director of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Attention:

Mr. Steven A. Varga, Chief Operating Reaciors Branch No. 1 Division of Licensing

Subject:

Indian Point 3 Nuclear Power Plant Docket No. 50-286 Steam Generator Sleeving Report

Dear Sir:

Enclosed are six copies of the non-proprietary version of the Indian Point 3 sleeving report which was prepared by Westinghouse, entitled "Indian Point Unit 3 Steam Generator Sleeving Report Prepared for the Power Authority of the State of New York, WCAP-10146, September, 1982".

The proprietary version was transmitted to the. NRC by letter dated October 18, 1982 (IPN-82-70).

Also enclosed is Westinghouse Authorization CAW-82-62, a non proprietary document, which supercedes Westinghouse Authorization CAW-82-50 transmitted to the NRC by the aforementioned October 18, 1982 letter.

In addition, it should be noted that all references in the Authority's October 19, 1982 "Application for Amendment to Operating License" to the aforementioned sleeving report pertain to Revision 1 of the sleeving report.

Should you or your staff have any questions, please contact Mr. P. Kokolakis of my staff.

Very truly yours, Bayne Ex Vice President NucearGeneration Enc.

cc: attached 4',

4§212210259,8B21,206 DR ADOCK 05000-28 6---

_P

" PDR Itit

cc:

Resident Inspector's Office Indian Point 3 U. S. Nuclear Regulatory Commission P. 0. Box 38 Buchanan, New York 10511