Review of the Refueling Outage Steam Generator Tube Inservice Inspection Report
ML093280169
Person / Time
Site: Fort Calhoun 
Issue date: 11/25/2009
From: Lynnea Wilkins
Plant Licensing Branch IV
To: Bannister D
Omaha Public Power District
Wilkins, L E, NRR/DORL/LPL4, 415-1377
References
TAC ME0313
Download: ML093280169 (3)


Text

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 November 25, 2009 Mr. David J. Bannister Vice President and CNO Omaha Public Power District Fort Calhoun Station 444 South 16th St. Mall Omaha, NE 68102-2247 SUB~IECT:

FORT CALHOUN STATION, UNIT 1 - REVIEW OF THE 2008 REFUELING OUTAGE STEAM GENERATOR TUBE INSERVICE INSPECTION REPORT (TAC NO. ME0313)

Dear Mr. Bannister:

By letter dated December 9, 2008 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML083440629), and supplemented by letter dated October 16, 2009 (ADAMS Accession No. ML093000157), Omaha Public Power Distribution (the licensee),

submitted information summarizing the results of the 2008 steam generator tube inspections performed at Fort Calhoun Station, Unit 1 during the 2008 refueling outage.

The Nuclear Regulatory Commission (NRC) staff has completed its review of the report and concludes that the licensee provided the information required by its technical specifications and no additional follow-up is required at this time. The NRC staff's review of the report is enclosed.

Sincerely,

'So. 'w q \\L1 G~\\"'-\\~ +

Lynnea Wilkins, Project Manager Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-285

Enclosure:

As stated cc w/encl: Distribution via Listserv

REVIEW OF STEAM GENERATOR TUBE INSPECTION REPORT FOR THE 2008 REFUELING OUTAGE FORT CALHOUN STATION UNIT 1 DOCKET NO. 50-285 By letter dated December 9, 2008 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML083440629), and supplemented by letter dated October 16, 2009 (ADAMS Accession No. ML093000157), Omaha Public Power Distribution (the licensee),

submitted information summarizing the results of the 2008 steam generator (SG) tube inspections performed at Fort Calhoun Station, Unit 1 (FCS) during the 2008 refueling outage.

FCS has two Mitsubishi Heavy Industries re-circulating model MHI-49TT-1 SGs. Each SG contains 5200 thermally-treated Alloy 690 tubes. Each tube has a nominal outside diameter of

% inches with a nominal wall thickness of 0.043 inches. The tubes were hydraulically expanded at both ends for the full length of the tubesheet and are supported by a series of type 405 stainless steel structures.

The licensee provided the scope, extent, methods, and results of its SG tube inspections in the documents referenced above. In addition, the licensee described corrective actions, such as tube plugging, taken in response to the inspection findings. The tubes in both SGs were inspected during the 2008 refueling outage.

After reviewing the information provided by the licensee, the Nuclear Regulatory Commission (NRC) staff has the following comments or observations:

The FCS SGs were replaced during its 2006 refueling outage. The first inservice inspection was performed in 2008.

Two new dent indications were identified in two different tubes in SG RC-2A and one new dent was identified in SG RC-2B with voltages of approximately 1 volt.

The licensee reported that the cause of the dents is indeterminable due to the small magnitude of the indications.

No wear was observed.

Based on a review of the information provided, the NRC staff concludes that the licensee provided the information required by the technical specifications. In addition, the NRC staff concludes that there are no technical issues that warrant follow-up action at this time since the inspections appear to be consistent with the objective of detecting potential tube degradation and the inspection results appear to be consistent with industry operating experience at similarly designed and operated units.

Enclosure

ML093000157), Omaha Public Power Distribution (the licensee),

submitted information summarizing the results of the 2008 steam generator tube inspections performed at Fort Calhoun Station, Unit 1 during the 2008 refueling outage.

The Nuclear Regulatory Commission (NRC) staff has completed its review of the report and concludes that the licensee provided the information required by its technical specifications and no additional follow-up is required at this time. The NRC staff's review of the report is enclosed.

Sincerely, IRA by Balwant K. Singal fori Lynnea Wilkins, Project Manager Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-285

Enclosure: