ML093080803

From kanterella
Jump to navigation Jump to search
E-mail from J. White to N. Sheehan, Question Related to Oyster Creek Inspections
ML093080803
Person / Time
Site: Oyster Creek
Issue date: 05/15/2009
From: Jason White
NRC/RGN-I/DRS/PSB2
To: Neil Sheehan
NRC Region 1
References
FOIA/PA-2009-0214
Download: ML093080803 (1)


Text

,Gray, Harold From:

John White Sent:

Friday, May 15, 2009 8:13 AM To:

Neil Sheehan Cc:

Ronald Nimitz; Harold Gray; John Richmond

Subject:

RE: Question re: Oyster Creek inspections A 6" aluminum pipe (A-4, condensate pumps to turbine building) in the same area was inspected previously.

The leaking pipes were CS-24 (10" carbon steel associated with hotwell level control) and CS-25 (8" carbon steel associated with hotwell level control. They were not selected for prior inspection.

From: Neil Sheehan Sent: Thursday, May 14, 2009 4:06 PM

'To: John White

Subject:

Question re: Oyster Creek inspections Can you refresh my memory on this?

Neil:

RE: Al. At least one of them was inspected by Exelon but it looks like in a different spot.'

Were one or both pipes with leaks inspected before the plant's license was renewed and, if so, where and when and what were the results?

Thanks.

Todd