W UNITED STATES ATOMIC ENERGY COMMISSION JUL 51968 LICENSE AMENDMENT
.for DELIVERY OF SPECIAL NUCLEAR MATERIAL to a CARRIER FOR TRANSPORT Pursuant to the Atomic Energy Act of 1954 and Title 10, Code of Federal Regulations, Chapter 1, Part 70,and Part 71, the following amendment to the special nuclear material license identified below is h*ereby.issued, authorizing the licensee to deliver special nuclear material to a carrier for'transport, and.is subject to the conditions specified in that license
.and to the conditions specified below.
Licensee
- 3.
License No.
- 1. Name:
Kerr-McGee Corporation Amendment No.. 71-5
- 2. Address:
Kerr-McGee Building Oklahoma City, Oklahoma 73102
- 4.
Docket No.70-925 CONDITIONS S. (a)
Packaging (1)
Model number (2)
Description OR-12 (See Page 2, Uranium hexafluoride:
enrichment in the U-235 isotope not to exceed S.Q%,
H/U-235 ratio not to exceed 1.7.
(b) Contents (1) Type and form of material (2)
Maximum quantity of 45(
material per package 6.S (c)
Fissile Class (1) Minimum number of radi-ation units to be shown on label for Class II (2)
Maximum number of packages per shipment for Class III pounds UF6, containing not more than
) k& U-235.
II
-0.9-N. A.
9 9
LICENSEE:
Kerr-McGee Corporation com 1:
PAGE 2 LICENSE NO,: SNM-928 AMENDMENT NO.: 71-5 DOCKET NO.: 70-925
- 5.
(a)(2)
Twelve inch ID x 53-inch long UF6 cylinder, as described in Section 4.2, Figure a(7), TID-7019; protective package for 12-inch diameter UF6 cylinder as described in K-1714.
- 6.
Existing approvals for the delivery of 12-inch diameter UF6 cylinders to a carrier for transport, under Special Nuclear Material License No.
SNM-928 shall remain in effect under the existing terms and conditions until August 31,
- 1968, REFERENCES Licensee's application for a superseding license to deliver special nuclear material to a carrier for transport, dated November 16, 1966.
Supplement dated January 31, 1968.
K-1714, "Protective Shipping Packages for 8-and 12-Inch Diameter UF6 Cylinders,"
April 20, 1967, Union Carbide Corporation, Nuclear Division, Oak Ridge Gaseous Diffusion Plant, Oak Ridge, Tennessee, TID-7019, "Guide to Shipment of U-235 Enriched Uranium Materials," USAEC, June 1959.
4d0 FOR THE ATOMIC ENERGY COMMISSION mi 5 1968 Date of Amendment Donald A. Nussbaumer Division of Materials Licensing