ML092740464
| ML092740464 | |
| Person / Time | |
|---|---|
| Site: | 07000925 |
| Issue date: | 09/29/1970 |
| From: | Nussbaumer D US Atomic Energy Commission (AEC) |
| To: | Pittman F Kerr-McGee Corp |
| References | |
| Download: ML092740464 (3) | |
Text
SEP 2 9 1970 70-025 Am~endment No. 71-13
!err-Mcwee Corporation Attn:
Dr. F. K. Pittman O.klahoma City, Okla*oma 73102 Gent lemen:
Enclosed is Amendment No. 71-13 to Speelal Nuclear Materiatl License N.i SM4-928 euthorizing the delivery of special nuclear material to
- carrier for transport in the 0-3 pakagae.
Please note,that this ame.dment does not authorize the..transprt.of
Such transport ia normally subjct: to
.regulation by the Department of, Transportation (DOT.
quefstionks re-sar4ing their requitements ahouId be drecited ýto 1)?.
Sincerely, original Signed by Doniald A. ýUssbaumer
Enclosure:
As stated cc; Mr. William A. Brobst DOT Donald A. Nusebaumer, Chief Fuel Fabrication and Tranaportation Branch Division of Materials Licensing Distribution:
Docket File, w/encl.4 hZ Document Room, w/encl.
State Health (License only)
Compliance, HQ (2), w/encl.
H.
J. McAlduff,
- OROO, w/encl.
R. Weber, SMM, w/encl.
- Director, NMS, w/encl.
A.
Cabell, ADM:DR, w/encl.
R. L. Stevenson, DML, w/encl.
J. C.
- Delaney, DML, w/encl.
C.
E. MacDonald,
- DML, w/encl.
(2)
Branch R/F Division R/F OFFICE D DML D
R...
M..Mac*onald/vj* h RLStevenson DAN' SURNAME;D T
7--0---------
- /--*------..1;-
i
- -/70 9/25/70 9/
.S./b G
/EP O70 9/
Form AEC-318 (Rev. 9-53)
U.S. GOVERNMENT FRINTING OFFICE i969-0-364-598
- i ----
o us' aumer i4 / 70
For~iAEC7401a (7/1b5 9
co.py UNITED STATES ATOMIC ENERGY COMMISSION LICENSE AMENDMENT for DELIVERY OF RADIOACTIVE MATERIAL to a CARRIER FOR TRANSPORT Pursuant to the Atomic Energy Act of 1954 and Title 10, Chapter 1, Code of Federal Regulations, Part 30, "Rules of General Applicability to Licensing of Byproduct Material", Part 70, "Special Nuclear Material", as appropriate, and Part 71, "Packaging of Radioactive Material for Transport", the follow-ing amendment to the license identified below is hereby issued, authorizing the licensee to deliver radioactive material to a carrier for transport, and is subject to the conditions specified in that license and to the condi-tions specified below:
LICENSEE
- 1. Name:
Kerr-McGee Corporation
- 3.
License No.
- 2.
Address: Kerr-McGee Building Amendment No. 71-13 Oklahoma City, Oklahoma 73102 Docket No.70-925 CONDITIONS
- 4.
(a)
Packaging (1)
Model number KM-3 (2)
Description Inner container is a 11 5/16" ID by 52" long minimum 20-gage thick steel removable head drum with bolted ring closure.
Inner container is centered and supported in a 22 13/16" ID by 66 3/4" long steel outer container of minimum 20-gage thickness.
Closure of the outer container is by a deep fitting slip cover which is secured to the outer container by four tie bolts.
Center-ing and support mechanism is minimum 5 1/4" thick consisting of spirally wrapped layers of corrugated cardboard and innermost 12" diameter cardboard and 1/2" thick plywood spacers are placed in each end of the card-board tube.
A wood'spacer is positioned in the inner container to restrict the geom-etry of the contents.
Container is con-_
structed in accordance with Kerr-McGee Corporation Drawing NPD-206-3022 (Rev.
2).
K COpy Kerr-McGee Corporation PAGE NO:
LICENSEE:
2 of 2
LICENSE NO:
SNM-928 DOCKET NO:
70-925 (b)
Contents AMENDMENT NO:
71-13 (1) Type and form of material Uranium dioxide as clad MH-lA fuel elements of the following specifications:
Pellet diameter (Nom)
Rod diameter (Nom)
Fuel length (Nom)
Rods/element (Max)
Cross Section (Nom)
U-235/element (Max)
U-235 enrichment (Max) 0.457" 0.490" 36" 104 6.2" sq 4.4 kgs 4.72 w/o (2)
Maximum quantity of material per package (c)
Fissile Class (1) Minimum transport index to be shown on label for Class II One (1) MH-lA fuel *element containing not more than 4.4 kgs U-235.
II 3.1
- 5.
The package authorized by this amendment is hereby approved for use under the general license provisions of Paragraph 71.7(b) of 10 CF.R Part 71.
REFERENCES Licensee's application dated September 17, 1970, requesting approval to deliver special nuclear material to a carrier for transport in the KM-3 package.
Supplement dated September 22, 1970.
Final Report U-4185, dated February 24, 1969, as amended March 19, 1969, by Mechanics Research, Inc.
a~0 0
FOR THE ATOMIC ENERGY COMMISSION Original Signed by.
Donald A. fussbaumer Date of Amendment SEP 2 9 1970 Donald A.
Nussbaumer Division of Materials Licensing