OCT 3 0 1970 MM;.E.

70-92-5 SNM-928, Amendment no. 71-14 Kerr-McGee Corporation Attn:

Dr. F. K. Pittman

,Kerr-MaGeeBuiliding Oklahoma City, oklahom 73102 Gentlemen:.

Enclosed is Amendment No. 71-14 to Special Nuclear Material License No. SNM-928 authorizing the delivery of special nuclear material to a carrier for transport in the Hodel,Number 1A. 8A, 12A, 12B3

3sA, and 30B packages.

.. ease note that-thisaen nt does not authoriae the transport of speciaý*l nuclear material.

Such transport is normally sibject to re*dlation by the epartmennt of Transportation (.W).

Qtestions re-gairdng their requirements should be directed to DOT.

Sincerely, Original Signed by.

Donald AL ilsbaurner' Donald :A.

asbaumer, Chie Fuel Fabrication: and Traunartat*ton Branch Division of. Materials, Licensing EnclOsure*

Distribution:

At stated Docket -File, w/encl Document Room, w/encl cc: Mr. Alfred W. Grella State Health (License only)

Department of Transportation Compliance, HQ (2), w/encl H. J. McAlduff, OROO, w/encl R. Weber, SNM, w/encl.

Director, NS., w/encl.

A. Cabell, ADM:DR, w/encl J. C. Delaney, DML, w/encl C. E. MacDonald, DML, w/encl (2)

Branch R/F, w/encl.

DML, R/F w/o encl.

OFFICE Do,

-I-L SURNAMEjo - ---aanal-d/-vj-hJDTae DAQusaumer

--- ------V -- ------------ -----------------

DATE lo/2 I

q l0/2'/2"- 10

/70 10/ )b /70 7----------

Form AEC-318 (Rev. 9-53) ii~qrvPMN P-N R--9 0

Form~AEC'.401a (7/70)

COPY UNITED STATES-

"ATOMIC ENERGY COMMISSION LICENSE AMENDMENT for DELIVERY OF RADIOACTIVE MATERIAL to a CARRIER FOR TRANSPORT Pursuant to the Atomic Energy Act of 1954 and Title 10, Chapter 1, Code of Federal Regulations, Part 30, "Rules of General Applicability to Licensing of Byproduct Material", Part 70, "Special Nuclear Material", as appropriate, and Part 71, "Packaging of Radioactive Material for Transport", the follow-ing amendment to the license identified below is hereby issued, authorizing the licensee to deliver radioactive material to a carrier for transport, and is subject to the conditions specified in that license and to the condi-tions specified below:

LICENSEE

1. Name:

Kerr-McGee Corporation

3.

License No.

SNM-928

2.

Address: Kerr-McGee Building Amendment No. 71-14 Oklahoma City, Oklahoma 73102 Docket No.70-925 CONDITIONS

4.

(a)

Packaging (1) Model number (2)

Description 5A, 8A,

12A, 12B, 30A, and 30B Five-inch, 8-inch, 12-inch, 30-inch ID UF6 cylinders as described in Section 8, ORO-651, Rev.

2 and UnAi"i Carbide Corpor-ation Drawing No. D-P35721-F for the Model 30B.

(b)

Contents (1) Type,..form and maximum quantity,.6f material per package Uranium hexafluoride with a maximum U-235 enrichment, H/U atomic ratio, pounds UF6, and U-235 content for the cylinder models as follows:

Model Number 5A 8A 12A, 12B 30A, 30B Max. Enrichment w/o U-235 100.0 12.5 5.0 5.0 Max. H/U Max. UF6 Atomic Ratio Pounds

..0.1 005 1.0 10.0 Max. U-235 kgs 0.031

0. 019 0.015 0.153 0.088

Kerr-McGee CorporaQo4.

LICENSEE:

PAGE NO:

2 LICENSE NO:

SNM-928 AMENDMENT NO:

7114 DOCKET NO:

70-925 (c)

Fissile Class I

5.

The packages authorized by this amendment are hereby approved for use under the, general license provisions of Paragraph 71.7(b) of 10 CFR Part 71.

REFERENCES Licensee's application dated October 15, 1970, requesting approval to deliver special nuclear material to a carrier for transport in the packages listed above.

FOR THE ATOMIC ENERGY COMMISSION OCT 3 0 1970 Original Signed by Donald A. tJussbaumer Date of Amendment CODr.ý,,onald A. Nussbaumer

~iDivision of Materials Licensing