October 29, 2009 Dr. Mario V. Bonaca, Chairman Advisory Committee on Reactor Safeguards U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001
SUBJECT:
RESPONSE TO THE ADVISORY COMMITTEE ON REACTOR SAFEGUARDS REPORT ON THE SAFETY ASPECTS OF THE LICENSE RENEWAL APPLICATION FOR THE BEAVER VALLEY POWER STATION, UNITS 1 AND 2
Dear Dr. Bonaca:
During the 565th meeting of the Advisory Committee on Reactor Safeguards (ACRS or the Committee) held September 10-12, 2009, the Committee completed its review of the license renewal application for the Beaver Valley Power Station, Units 1 and 2, and the associated final safety evaluation report prepared by the U.S. Nuclear Regulatory Commission (NRC). In the Committees final report, dated September 16, 2009, the Committee recommends renewal of the Beaver Valley Power Station, Units 1 and 2, operating license. The NRC staff appreciates the Committees expeditious review of the plants license renewal application and the associated final safety evaluation report.
As you mentioned in your report, dated September 16, 2009, the staff is reviewing the impact of the containment liner corrosion on the current licensing basis of the plant. The staff has initiated the following actions and expects to be ready to discuss these actions at an upcoming ACRS meeting as early as July 2010:
Staff is making changes to Inspection Procedure (IP) 71111.20, Refueling and Outage Activities Baseline Inspection Procedure, to notify inspectors that containments should be inspected as soon as practicable after shutdown, and to be certain to check for items that may be indicative of containment liner corrosion.
Staff is evaluating the need for issuing a supplement to Information Notice (IN) 2004-09, Corrosion of Steel Containment and Containment Liner, to holders of operating licenses or construction permits to review the Beaver Valley Power Station, Unit 1 operating experience for applicability to their facilities and consider actions, as appropriate.
Staff and industry members submitted a new agenda item in the last American Society of Mechanical Engineers (ASME) Subsection IWE meeting to identify early detection methods for liner plate degradation.
The Office of Nuclear Reactor Regulation is requesting the Office of Nuclear Regulatory Research investigate the mechanism responsible for through-wall corrosion of containment liners.
The staff recognizes the Committees commitment to safety and appreciates its continued support of the license renewal process.
Sincerely, Bruce S. Mallett for:
R. W. Borchardt Executive Director for Operations cc: Chairman Jaczko Commissioner Klein Commissioner Svinicki SECY
ML092680073 (Package) ML092660097 (Incoming)
ML092680094 (Response)
- concurred via e-mail OFFICE PM:RPB2:DLR LA:RPOB:DLR Tech Editor
NAME KHoward IKing CHsu LSubin DATE 10/05/09 09/30/09 09/30/09 10/02/09 OFFICE D:DCI:NRR D:DORL:NRR D:DE:NRR BC:DRS:RI
- NAME MEvans JGiitter PHiland RConte DATE 10/19/09 10/15/09 10/19/09 10/14/09 OFFICE BC:RPB2:DLR D:DLR:NRR D:NRR EDO NAME DWrona BHolian ELeeds RBorchardt BMallett for DATE 10/14/09 10/19/09 10/22/09 10/29/09
Letter to Mario V. Bonaca from R. W. Borchardt dated October 29, 2009
SUBJECT:
RESPONSE TO THE ADVISORY COMMITTEE ON REACTOR SAFEGUARDS REPORT ON THE SAFETY ASPECTS OF THE LICENSE RENEWAL APPLICATION FOR THE BEAVER VALLEY POWER STATION, UNITS 1 AND 2 DISTRIBUTION: G20090535/LTR-09-0462/EDATS: SECY-2009-0421 HARD COPY:
PUBLIC RidsEdoMailCenter Resource RidsNrrOd Resource RidsNrrAdro Resource RidsNrrAdes Resource RidsNrrMailCenter Resource RidsOgcMailCenter Resource RidsSecyMailCenter Resource RidsResOd Resource RidsRgn1MailCener Resource RidsAcrsAcnw_MailCTR Resource RidsNrrDlr Resource RidsNrrDlrRpb1 Resource RidsNrrDlrRpb2 Resource RidsNrrDlrRer1 Resource RidsNrrDlrRer2 Resource RidsNrrDlrRerb Resource RidsNrrDlrRpob Resource RidsNrrDciCvib Resource RidsNrrDciCpnb Resource RidsNrrDciCsgb Resource RidsNrrDraAfpb Resource RidsNrrDraApla Resource RidsNrrDeEmcb Resource RidsNrrDeEeeb Resource RidsNrrDssSrxb Resource RidsNrrDssSbpb Resource RidsNrrDssScvb Resource RidsOgcMailCenter Resource KHoward, NRR NMorgan, NRR MModes, RI PCataldo, RI DWerkheiser, RI RBellamy, RI RConti, RI JRichmond, RI