ML092650610
| ML092650610 | |
| Person / Time | |
|---|---|
| Site: | Indian Point |
| Issue date: | 09/24/2009 |
| From: | Boska J Plant Licensing Branch 1 |
| To: | Entergy Nuclear Operations |
| Boska J, NRR, 301-415-2901 | |
| References | |
| TAC MD7501 | |
| Download: ML092650610 (3) | |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 Vice President, Operations Entergy Nuclear Operations, Inc.
Indian Point Energy Center 450 Broadway, GSB P.O. Box 249 Buchanan, NY 10511-0249 SUB-JECT:
INDIAN POINT NUCLEAR GENERATING UNIT NO.2 - CORRECTION TO TECHNICAL SPECIFICATIONS (TAC NO. MD7501)
Dear Sir or Madam:
The purpose of this letter is to issue the following typographical correction to the Indian Point Nuclear Generating Unit No.2 (IP2) Technical Specifications (TSs).
By letter dated October 29,2008, Agencywide Documents Access and Management System (ADAMS) Accession 1\\10. ML082700099, the Nuclear Regulatory Commission issued License Amendment No. 256 to Facility Operating License No. DPR-26 for IP2. Although not a part of the amendment request, a typographical error was introduced on TS Page 3.5.2-2 by inadvertently revising the position of valve 856F from closed to open in Surveillance Requirement 3.5.2.1. Please replace the corresponding page from the TSs with the corrected TS page 3.5.2-2 enclosed with this letter.
Please contact me at (301) 415-2901 if you have any questions on this issue.
Sincerely, Ck-9~
a~~~; Boska, Senior Project Manager Plant Licensing Branch 1-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-247
Enclosure:
Corrected TS Page 3.5.2-2 cc w/encl: Distribution via Listserv
ECCS - Operating 3.5.2 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.5.2.1 Verify the following valves are in the listed position with power to the valve operator removed.
Number Position Function 842 Open SI Test Line Stop 843 Open SI Test Line Stop 883 Closed RHR Return to RWST 743 Open RHR Miniflow Line 1870 Open RHR Miniflow Line 856B Closed HH Branch Line Stop Valve 23 Loop Hot Leg 856F Closed HH Branch Line Stop Valve 21 Loop Hot Leg 1810 Open Common RWST Suction Isolation for HHSI Pumps 882 Open Common Suction Isolation for RHR Pumps 744 Open Common discharge isolation for RHR pumps 7 days SR 3.5.2.2 Verify each ECCS manual, power operated, and automatic valve in the flow path, that is not locked, sealed, or otherwise secured in position, is in the correct position.
31 days SR 3.5.2.3 Verify each ECCS pump's developed head at the test flow point is greater than or equal to the required developed head.
In accordance with the Inservice Testing Program SR 3.5.2.4 Verify each ECCS automatic valve in the flow path that is not locked, sealed, or otherwise secured in position, actuates to the correct position on an actual or simulated actuation signal.
24 months Indian Point 2 3.5.2 - 2 Amendment No. 256 Revised by letter dated September 24,2009
September 24, 2009 Vice President, Operations Entergy Nuclear Operations, Inc.
Indian Point Energy Center 450 Broadway, GSB P.O. Box 249 Buchanan, NY 10511-0249
SUBJECT:
INDIAN POINT NUCLEAR GENERATING UNIT NO.2 - CORRECTION TO TECHNICAL SPECIFICATIONS (TAC NO. MD7501)
Dear Sir or Madam:
The purpose of this letter is to issue the following typographical correction to the Indian Point Nuclear Generating Unit NO.2 (IP2) Technical Specifications (TSs).
By letter dated October 29, 2008, Agencywide Documents Access and Management System (ADAMS) Accession No. ML082700099, the Nuclear Regulatory Commission issued License Amendment No. 256 to Facility Operating License No. DPR-26 for IP2. Although not a part of the amendment request, a typographical error was introduced on TS Page 3.5.2-2 by inadvertently revising the position of valve 856F from closed to open in Surveillance Requirement 3.5.2.1. Please replace the corresponding page from the TSs with the corrected TS page 3.5.2-2 enclosed with this letter.
Please contact me at (301) 415-2901 if you have any questions on this issue.
Sincerely, IRAI John P. Boska, Senior Project Manager Plant Licensing Branch 1-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-247
Enclosure:
Corrected TS Page 3.5.2-2 cc w/encl: Distribution via Listserv DISTRIBUTION:
PUBLIC LPL 1-1 R/F RidsNrrDorl RidsNrrDorlLpl1-1 RidsNrrDorlDpr RidsNrrPMlndianPoint RidsNrrLASLittle (paper copy)
RidsNrrDirsltsb RidsRgn1 MailCenter RidsOGCRp RidsAcrsAcnw MailCTR ADAMS ACCESSION NO'.. ML092650610 OFFICE LPL1-1/PM LPL 1-1/LA LPL1-1/BC NAME JBoska SLittie NSalgado DATE 9/23/09 9/23/09 9/24/09