ENCLOSURE SAN ONOFRE NUCLEAR GENERATING STATION (SONGS)

SONGS-3 CYCLE 15 STARTUP TEST ACTIVITY REDUCTION (STAR) PROGRAM IMPLEMENTATION

SUMMARY

REPORT Performed By A. Gershkoff

  • Reactor Engine Date.:

6

$O Reviewed By km

(-

\\&. c -,-*-.

D. P oWe&

Reactor Engineering Supervisor Date:

Approved By n e0. Nho r Fsel M nager, Nuclear Fuels Management Date: b

SONGS-3 Cycle 15 Summary Report Page 2 of 33 SONGS-3 CYCLE 15 STAR PROGRAM' IMPLEMENTATION

SUMMARY

REPORT Introduction Southern California Edison first applied the Startup Test Activity Reduction (STAR) Program methodology to San Onofre Nuclear Generating Station (SONGS) Unit 2 Cycle 15, which allowed the elimination of Control Element Assembly (CEA) group worth measurements from the Low Power Physics Test (LPPT) Program.

SONGS Technical Specification Surveillance Requirement (SR) 3.1.4.1, "Verify MTC [Moderator Temperature Coefficient] within the upper limit [prior to entering Mode 1 after each fuel loading]," was not changed prior to SONGS-3 Cycle 15 initial criticality; therefore, SR 3.1.4.1 was performed consistent with previous cycles, as allowed by Reference 1.

The SONGS-3 Cycle 15 STAR Implementation Summary Report includes information as required from Condition/Limitation #3 of the NRC safety evaluation,,:-

of Reference 1, which states, "The staff requires each licensee using STAR to submit a summary report following the first application, either successful or not, of STAR to its plant.

The report should (a) identify the core design method used, (b), compare the&

measured and calculated values and the differences between these values to the corresponding core design method uncertainties and (c) show compliance..

with the STAR applicability requirements. If the application of STAR is unsuccessful, identify the reasons why the STAR application failed."

Core Design Method The Westinghouse Reactor Operation and Control Simulator (ROCS) computer program and Studsvik SIMULATE-3 (SIM-3) computer program were used for the core design and startup test predictions of SONGS-3 Cycle 15, consistent with Reference 2.

STAR Test Results and Associated Uncertainties Table 1, "STAR Test Results and Uncertainties," provides results from the SONGS-3 Cycle 15 LPPT Program, consistent with the list of STAR program tests provided in Table 3-3 of Reference 1. All of the measured values were within test acceptance criteria. Differences between measured and predicted (calculated) parameters compared favorably with the core design method uncertainties.

SONGS-3 Cycle.15 Summary Report Page 3 of 33 STAR Applicability Requirements Reference 1 Table 3-4, "STAR Program Applicability Requirements," lists the applicability requirements for use of the STAR program. The STAR applicability requirements involve the following 5 areas: 1) Core Design, 2) Fabrication (Fuel Assembly and Control Element Assembly (CEA)), 3) Refueling, 4) CEA Lifetime, and 5) Startup Testing. Prior to eliminating the CEA group worth measurements from the SONGS-3 Cycle 15 Low Power Physics Test program, all STAR applicability requirements were verified to be met.

Conformance with the Core Design applicability requirements is documented in Reference 3.

Conformance with the Fuel Fabrication applicability requirements is documented in Reference 4.

Conformance with the CEA Fabrication applicability requirements is documented in Reference 5.

Conformancel-with the Refueling requirements is documented in References 6 and 7. Reference 6, as performed for SONGS-3 Cycle 15, documents verificationof proper CEA coupling based on visual criteria consistent with Reference.. l:Table 3-4: 1) weight comparison of coupled vs. uncoupled CEA, 2) visual verification of "7-slot" pin position, 3) visual height comparison of CEA extension shafts, and 4) reweighing of coupled CEA extension shafts by an independent team. Reference 7, as performed for SONGS-3 Cycle 15, documents verification that the fuel assemblies and CEAs are installed in the proper location and with the correct orientation.

Conformance with the CEA Lifetime applicability requirements is documented in References 8 and 9. The eighty-three full length CEAs used in the SONGS-3 Cycle 15 core are comprised of seventy-five new 5-finger CEAs, four re-used 5-finger CEAs that were new for Cycle 14, and four re-used 4-finger CEAs that were new for Cycle 13. At most, Cycle 15 represents a third cycle of operation for its constituent CEAs. Reference 8 concludes that these CEAs will be within the CEA lifetime requirements throughout Cycle 17 operation. Therefore, all of the full length CEAs utilized in SONGS-3 Cycle 15 are within established limits.

Conformance with the Startup Testing requirement of Critical Boron Concentration within 500 pcm of prediction is documented in Reference 10, as performed for SONGS-3 Cycle 15. Test results are provided in Attachment 1.

SONGS-3 Cycle 15 Summary Report Page 4 of 33 Summary The measured test results for all the required STAR tests in Table 3-3 of Reference 1 were within the test acceptance criteria; all test results compared favorably with the associated core design method uncertainties. Compliance with the STAR applicability requirements was demonstrated. Therefore, all of the requirements to implement STAR for SONGS-3 Cycle 15 were met. STAR was implemented successfully for SONGS-3 Cycle 15.

References

1. WCAP-1 6011-P-A, Revision 0, "Startup Test Activity Reduction Program,"

February 2005 (referred to in this report as STAR)

2. SCE-9801 -P-A, Reload Analysis Methodology for the San Onofre Nuclear Generating Station Units 2 and 3 [Reload Topical Report],

June 1999

3. Calculation NFM-3-PH-1519 (Rev 0), SONGS-3 Cycle 15 STAR Physics;-.

Verification, 7/16/2008

4. Calculation'- NFM-3-MI-1501 (Rev 0), SONGS-3 Cycle 15 Fuel Mechanical Design Inputs, 5/5/2008
5. Calculation, NFM-3-MI-1502 (Rev 0), SONGS-3 Cycle 15 CEA STAR Verification, 8/12/2008
6. Procedure S023-1-3.46, Remote Five Finger CEA Extension Shaft Coupling, Rev. 5, 11/12/2008
7. Procedure S023-X-7, Nuclear Fuel Movement for Refueling Cycles, Rev 16, 10/17/2008
8. Calculation N-1020-175, CEA Life Limit for Units 2 and 3 Cycles 15 through 17, 5/10/2007
9. Calculation NFM-3-PH-1520, SONGS-3 Cycle 15 Physics RAR Input, 7/1/2008,
10. Procedure S023-XXXVII-1, Low Power Physics Testing, Rev. 6, 7/1/2008

SONGS-3 Cycle 15 Summary Report Page 5 of 33 ATTACHMENT 1 TEST RESULTS TABLE 1 STAR TEST RESULTS AND UNCERTAINTIES TEST POWER MEASURED CALCULATED DIFFERENCE TEST CRITERIA UNCERTAINTY VALUE VALUE Drop Time to Maximum CEA Drop Time Shutdown 90% Inserted:

N/A N/A Allowed:

N/A 3.05 sec avg, 3.4 sec avg, 3.22 sec max 3.6 sec max 30 (of 91) CEAs idehitified td be Procedureand CE rp iecouple checked With reactimeter;

.program CEA Drop time Shutdncouple checked o

h 3CEactuy conservatisms All CEAs verified CharacteristicsShutdown couple check of 33 CEAs actually dictated couple to be coupled N/A performed with reactimeter; all CEAs checks of 33 verified to be coupled CEAs 50 ppm Critical Boron Hot Zero Power 2162 ppm 2164 ppm

-2 ppm (procedural 26 ppm Concentration (CBC)

(HZP)

(-14 pcm) review),

500 pcm (STAR)

Moderator Temperature Coefficient (MTC)

HZP

+1.1 pcmifF

+1.1 pcm/tF

-0.0 pcm/fF MTC < 5 pcm/PF

+/- 2.4 pcmPF Alternate Surveillance MTC, as measured HZP

+0.7 pcmI0 F

+1.1 pcm/°F

-0.4 pcm/F MTC < 5 pcm/F;

+/-

using Reactimeter 0.7-1.1 iff

-0.

3 cm F

2.4 pcm3pF Relative Power

+5.22% max Density (RPD)

Incore Flux positive; within +/- 10% of Symmetry Low (20%)

See Table 2 See Table 2

-34%ms-rdcinfrfe N/A Symery-3.42%

most prediction for fuel negative assemblies with RPD > 0.9

SONGS-3 Cycle 15 Summary Report Page 6 of 33 ATTACHMENT 1 TEST RESULTS TABLE 1 STAR TEST RESULTS AND UNCERTAINTIES TEST POWER MEASURED CALCULATED DIFFERENCE TEST CRITERIA UNCERTAINTY VALUE VALUE

@ 20% power:

@ 20% power:

@ 20% power:

See Table 2 See Table 2 1.54% RMS

< 5% RMS N/A Radial PD;

@ 65% power:

@ 65% power:

@ 65% power:

See Table 3 See Table 3 1.56% RMS

< 5% RMS N/A Incore Power Radial PD; Distribution Intermediate See Table 4 See Table 4 3.42% RMS

< 5% RMS N/A

Axial PD; Fq = 1.70; Fq= 1.74;

-2.4%;

<+/- 10%

+/- 5.93%;

Fxy =1.47; Fxy =1.50;

-1.9%;

< +/- 10%

+/- 5.46%;

Fr =1.42; Fr =1.46;

-2.5%

< +/- 10%

+/- 4.24%;

Fz =1.18 Fz =1.20

-1.8%

< +/- 10%

N/A Isothermal Intermediate to Temperature Hot Full Power

-10.1 pcm/F

-10.Opcm/PF

-0.1 pcm/F Diff < 3 pcm/fF

+ 2.4 pcm/PF Coefficient (ITC)

(HFP)

-4.9 pcm/F

-4.5 pcm/fF

-0.4 pcm/F

< -0.6 pcm/fF

@ 70% power;

-7.6 pcm/fF

-7.2 pcm/PF

-0.4 pcm/tF

< -3.0 pcm/PF

@ 100% power; Intermediate to

-36.4 pcm/PF

-36.0 pcm/fF

-0.4 pcm/PF

> -37 pcm/PF MTC Surveillance

@ EOC 100%

+/- 2.4 pcm/fF (from HZP test);

-36.1 pcm/F

-36.0 pcm/tF

-0.1 pcm/fF

> -37 pcm/fF

@ EOC 100%

(from 48 EFPD HFP test)

SONGS-3 Cycle 15 Summary Report Page 7 of 33 ATTACHMENT 1 TEST RESULTS TABLE 1 STAR TEST RESULTS AND UNCERTAINTIES TEST POWER MEASURED CALCULATED DIFFERENCE TEST CRITERIA UNCERTAINTY VALUE VALUE See Table 5 See Table 5 1.42% RMS

< 5% RMS N/A Radial PD; See Table 6 See Table 6 2.73% RMS

< 5% RMS N/A Incore Power HFP Axial PD; Distribution Fq = 1.68; Fq = 1.72;

-2.3%;

<+/- 10%

_ 5.93%;

Fxy= 1.46; Fxy= 1.49;

-2.1%;

< +/- 10%

+/-5.46%;

Fr =1.42; Fr =1.45;

-2.0%

< +/- 10%

+/-4.24%;

Fz =1.16 Fz =1.19

-2.5%

<+/-10%

N/A A CBC HZP - HFP HFP 592 ppmr 583 ppm

+9 ppm

+ 74 ppm

_ 26 ppm

SONGS-3 Cycle 15 Summary Report Page 8 of 33 ATTACHMENT 1 TEST RESULTS TABLE 2 20% RADIAL POWER DISTRIBUTION PREDICTED RELATIVE POWER DENSITIES Assy #

RPD 1

2 0.417 0.838 3

4 0.838 0.418 5

6 0.312 0.507 7

0.880 8

9 1.162 1.056 10 1.163 11 0.881 12 0.508 13 0.313 14 0.415 15 0.916 16 1.087 17

.195 18 1.213 19 1.348 20 1.215 21 1.195 22 1.088 23 0.917 24 0.415 1

25 0.415 26 0.962 27 1.174 28 1.266 29 1.096 30 1.301 31 1.160 32 1.301 33-1.092 34 1.267 35 1.177 36 0.962 37 0.415 100 0.838 117 0.838 134 0.417 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 0.313 0.917 1.177 1.323 1.159 1.261 1.093 1.258 1.093 1.262 1.163 1.323 1.174 0,916 0.312 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 0.508 1.088 1.267 1.163 1.277 1.087 1.218 1.060 1.220 1.088 1.277 1.159 1.266 1,087 0.507 68 69 70 71 72 73

,74

-75 76 77 78 79 80 81 82 0.881 1.195 1.092 1.262 1.088 1.180 1.003 1.100 1.005 1.180 1.087 1.261 1.096 1.195 0.880 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 1.163 1.215 1.301 1.093 1.220 1.005 0.626 0.568 0.626 1.003 1.218 1.093 1.301 1.213 1.162 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 1.056 1.348 1.160 1.258 1.060 1.100 0.568 0.438 0.568 1.100 1.060 1.258 1.160 1.348 1.056 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 1.162 1.213 1.301 1.093 1.218 1.003 0.626 0.568 0.626 1.005 1.220 1.093 1.301 1.215 1.163 136 137 138

.139 140 141 142 143 144 145 146 147 148 149 150 0.880 1.195 1.096 1.261 1.087 1.180 1.005 1.100 1.003 1.180 1.088 1.262 1.092 1.195 0.881 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 0.507 1.087 1.266 1.159 1.277 1.088 1.220 1.060 1.218 1.087 1.277 1.163 1.267 1.088 0.508 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 0.312 0.916 1.174 1.323 1.163 1.262 1.093 1.258 1.093 1.261 1.159 1.323 1.177 0.917 0.313 84 0.417 101 0.838 118 0.838 135 0.418 181 0.4 15 182 0.962 183 1.177 184 1.267 185 1.092 186 187

.301 1.160

-188 1.30i1 189

'1.096 190 1.266 191 1.174 192 0.962 193 0.415 1

194 0.415 195 196 0.917 1.088 1.97 1.195

-. 198 199 1.215 1.348

29o, 1.213 201 202 1.195 1.087 203 0.916 204 0.415 205 0.313 206 0.508 207 0.881 208 209 1.163 1.056 210 1.162 211 212 0.880 0.507 213 0.312 214 215 216 21 0.418 10.8381 0.838 0.417

SONGS-3 Cycle 15 Summary Report Page 9 of 33 ATTACHMENT 1 TEST RESULTS TABLE 2 20% RADIAL POWER DISTRIBUTION MEASURED RELATIVE POWER DENSITIES 1

2 3

4 0.425 10.836 0.840 0.432 ASSY#

RPD 5

0.323 6

0.514 7

8 0.892 1.160 9

1.053 10 1.172 11 0.921 12 0.522 13 0.325 14 0.427 15 0.931 16 1.087 17 18 1.192 1.216 19 1.326 20 1.224 21 1.201 22 1.090 23 0.930 24 0.425 25 0.432 26 0.975 27 1.200 28 1.264 29 30 1.099 1.286 31 1.160 32 1.284 33 1.091 34 1.259 35 1.195 36 0.967 37 0.433 83 0.419 100 0.839 117 0.840 134 0.423 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52

0. 32 1 0.946 1.203 1.321 1.165 1.252 1.092 1.226 1.088 1.244 1.160 1.305 1.181 0.927 0.313 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 0.520 1.131 1.280 1.168 1.266 1.086 1.195 1.038 1.193 1.075 1.253 1.142 1.254 1.095 0.506 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 0.877 1.203 1.107 1.247 1.085 1.160 0.993 1.069 0.996 1.158 1.080 1.240 1.097 1.182 0.861 85 86 87 88 89 90 91

_92 93 94 95 96 97 98 99 1.160 1.216 1.279 1.066 1.192 0.991 0.619 0.535 0.620 0.998 1.197 1.081 1.278 1.205 1.145 102 103 104 105 106 107' 1081.

'109-110 111 112 113 114 115 116 1.071 1.325 1.154 1.215 1.052 1.088 0.571 0.432 0.570 1.085 1.055 1.223 1.157 1.325 1.065 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 1.159 1.209 1.278 1.066 1.199 1.012 0.627 0.540 0.622 0.994 1.198 1.075 1.284 1.222 1.157 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 0.879 1.205 1.112 1.250 1.089 1.171 1.007 1.080 1.005 1.167 1.091 1.253 1.108 1.198 0.872 151 152 153 154 155 156' 157 158 159 160 161 162 163 164 165 0.523 1.142 1.284 1.168 1.271 1.087 1.206 1.050 1.206 1.092 1.272 1.171 1.275 1.111 0.515 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 0.323 0.952 1.203 1.322 1.174 1.259 1.101 1.237 1.100 1.258 1.170 1.324 1.201 0.940 0.319 84 0.408 101 0.830 118 0.834 135 0.416 181 0.438 182 0.976 183 1.196 184 1.269

185, 1.105 186 1.297 187 1.166 188 189 1.29.1-.1.103 190 1.266 191 1.206 192 0.977 193 0.436 194 0.427 195 0.930 196 1.096 197.

1.212 198 1.235 199 1.338 200 201 1.220 1.187 202 1.083 203 0.927 204 0.426 205 0.314 206 0.522 207 0.927 208 1.186 209 1.072 210 211 1.161 0.870 212 0.505 213 0.310

.1 ______________

£ C ~

.1

£ ~

U 4

+/- _____________

214 2150 ý216 0217 0.436t. 0.85 0.843 0.423

SONGS-3 Cycle 15 Summary Report Page 10 of 33 ATTACHMENT 1 TEST RESULTS TABLE 2 20% RADIAL POWER DISTRIBUTION ASSEMBLY MEASURED PREDICTED DIFFERENCE DIFF / PRED 1

0.425 0.417 0.008 0.0192 2

0.836 0.838

-0.002

-0.0024 3

0.840 0.838 0.002 0.0024 4

0.432 0.418 0.014 0.0335 5

0.323 0.312 0.011 0.0353 6

0.514 0.507 0.007 0.0138 7

0.892 0.880 0.012 0.0136 8

1.160 1.162

-0.002

-0.0017 9

1.053 1.056

-0.003

-0.0028 10 1.172 1.163 0.009 0.0077 11 0.921 0.881 0.040 0.0454 12 0.522 0.508

.0.014 0.0276 13 0.325 0.313 0.012 0.0383 14 0.427 0.415 0.012 0.0289 15 0.931 0.916 0.015 0.0164 16 1.087 1.087 0

0 17 1.192 1.195

-0.003

-0.0025 18 1.216 1.213

.0.003 0.0025 19 1.326 1.348

-0.022

-0.0163 20 1.224 1.215 0.009 0.0074 21 1.201 1.195 0.006 0.0050 22 1.090 1.088 0.002 0.0018 23 0.930 0.917 0.013 0.0142 24 0.425 0.415 0.010 0.0241 25 0.432 0.415 0.017 0.0410 26 0.975 0.962 0.013 0.0135 27 1.200 1.174 0.026 0.0221 28 1.264 1.266

-0.002

-0.0016 29 1.099 1.096 0.003 0.0027 30 1.286 1.301

-0.015

-0.0115 31 1.160 1.160 0

0 32 1.284 1.301

-0.017

-0.0131 33 1.091 1.092

-0.001

-0.0009 34 1.259 1.267

-0.008

-0.0063 35 1.195 1.177 0.018 0.0153 36 0.967 0.962 0.005 0.0052 37 0.433 0.415 0.018 0.0434 38 0.321 0.313 0.008 0.0256 39 0.946 0.917 0.029 0.0316 40 1.203 1.177 0.026 0.0221

SONGS-3 Cycle 15 Summary Report Page 11 of 33 ATTACHMENT 1 TEST RESULTS TABLE 2 20% RADIAL POWER DISTRIBUTION ASSEMBLY MEASURED PREDICTED DIFFERENCE DIFF / PRED 41 1.321 1.323

-0.002

-0.0015 42 1.165 1.159 0.006 0.0052 43 1.252 1.261

-0.009

-0.0071 44 1.092 1.093

-0.001

-0.0009 45 1.226 1.258

-0.032

-0.0254 46 1.088 1.093

-0.005

-0.0046 47 1.244 1.262

-0.018

-0.0143 48 1.160 1.163

-0.003

-0.0026 49 1.305 1.323

-0.018

-0.0136 50 1.181 1.174 0.007 0.0060 51 0.927 0.916 0.011 0.0120 52 0.313 0.312 0.001 0.0032 53 0.520 0.508 0.012 0.0236 54 1.131 1.088 0.043 0.0395 55 1.280 1.267 0.013 0.0103 56 1.168 1.163 0.005 0.0043 57 1.266 1.277

-0.011

-0.0086 58 1.086 1.087

-0.001

-0.0009 59 1.195 1.218

-0.023

-0.0189 60 1.038 1.060

-0.022

-0.0208 61 1.193 1.220

-0.027

-0.0221 62 1.075 1.088

-0.013

-0.0119 63 1.253 1.277

-0.024

-0.0188 64 1.142 1.159

-0.017

-0.0147 65 1.254 1.266

-0.012

-0.0095 66 1.095 1.087 0.008 0.0074 67 0.506 0.507

-0.001

-0.0020 68 0.877 0.881

-0.004

-0.0045 69 1.203 1.195 0.008 0.0067 70 1.107 1.092 0.015 0.0137 71 1.247 1.262

-0.015

-0.0119 72 1.085 1.088

-0.003

-0.0028 73 1.160 1.180

-0.020

-0.0169 74 0.993 1.003

-0.010

-0.0100 75 1.069 1.100

-0.031

-0.0282 76 0.996 1.005

-0.009

-0.0090 77 1.158 1.180

-0.022

-0.0186 78 1.080 1.087

-0.007

-0.0064 79 1.240 1.261

-0.021

-0.0167 80 1.097 1.096 0.001 0.0009

SONGS-3 Cycle 15 Summary Report Page 12 of 33 ATTACHMENT 1 TEST RESULTS TABLE 2 20% RADIAL POWER DISTRIBUTION ASSEMBLY MEASURED PREDICTED DIFFERENCE DIFF / PRED 81 1.182 1.195

-0.013

-0.0109 82 0.861 0.880

-0.019

-0.0216 83 0.419 0.418 0.001 0.0024 84 0.408 0.417

-0.009

-0.0216 85 1.160 1.163

-0.003

-0.0026 86 1.216 1.215 0.001 0.0008 87 1.279 1.301

-0.022

-0.0169 88 1.066 1.093

-0.027

-0.0247 89 1.192 1.220

-0.028

,-0.0230 90 0.991 1.005

-0.014

-0.0139 91 0.619 0.626

-0.007

-0.0112 92 0.535 0.568

-0.033

-0.0581 93 0.620 0.626

-0.006

-0.0096 94 0.998 1.003

-0.005

-0.0050 95 1.197 1.218

-0.021

-0.0172 96 1.081 1.093

-0.012

-0.0110 97 1.278 1.301

-0.023

-0.0177 98 1.205 1.213

-0.008

-0.0066 99 1.145 1.162

-0.017

-0.0146 100 0.839 0.838 0.001 0.0012 101 0.830 0.838

-0.008

-0.0095 102 1.071 1.056 0.015 0.0142 103 1.325 1.348

-0.023

-0.0171 104 1.154 1.160

-0.006

-0.0052 105 1.215 1.258

-0.043

-0.0342 106 1.052 1.060

-0.008

-0.0075 107 1.088 1.100

-0.012

-0.0109 108 0.571 0.568 0.003 0.0053 109 0.432 0.438

-0,006

-0.0137 110 0.570 0.568 0.002 0.0035 111 1.085 1.100

-0.015

-0.0136 112 1.055 1.060

-0.005

-0.0047 113 1.223 1.258

-0.035

-0.0278 114 1.157 1.160

-0.003

-0.0026 115 1.325 1.348

-0.023

-0.0171 116 1.065 1.056 0.009 0.0085 117 0.840 0.838 0.002 0.0024 118 0.834 0.838

-0.004

-0.0048 119 1.159 1.162

-0.003

-0.0026 120 1.209 1.213

-0.004

-0.0033

SONGS-3 Cycle 15 Summary Report Page 13 of 33 ATTACHMENT 1 TEST RESULTS TABLE 2 POWER DISTRIBUTION ASSEMBLY 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 20% RADIAL MEASURED 1.278 1.066 1.199 1.012 0.627 0.540 0.622 0.994

.1.198 1.075 1.284 1.222 1.157 0.423 0.416 0.879 1.205 1.112 1.250 1.089 1.171 1.007 1.08 1.005 1.167 1.091 1.253 1.108 1.198 0.872 0.523 1.142 1.284 1.168 1.271 1.087 1.206 1.050 1.206 1.092 PREDICTED 1.301 1.093 1.218 1.003 0.626 0.568 0.626 1.005 1.220 1.093 1.301 1.215 1.163 0.417 0.418 0.880 1.195 1.096 1.261 1.087 1.180 1.005 1.100 1.003 1.180 1.088 1.262 1.092 1.195 0.881 0.507 1.087 1.266 1.159 1.277 1.088 1.220 1.060 1.218 1.087 DIFFERENCE

-0.023

-0.027

-0.019 0.009 0.001

-0.028

-0.004

-0.011

-0.022

-0.018

-0.017 0.007

-0.006 0.006

-0.002

-0.001 0.010 0.016

-0.011 0.002

-0.009 0.002

-0.020 0.002

-0.013 0.003

-0.009 0.016 0.003

-0.009 0.016 0.055 0.018 0.009

-0.006

-0.001

-0.014

-0.010

-0.012 0.005 DIFF / PRED

-0.0177

-0.0247

-0.0156 0.0090 0.0016

-0.0493

-0.0064

-0.0109

-0.0180

-0.0165

-0.0131 0.0058

-0.0052 0.0144

-0.0048

-0.0011 0.0084 0.0146

-0.0087 0.0018,,

-0.0076 0.0020

-0.0182 0.0020

-0.0110 0.0028

-0.0071 0.0147 0.0025

-0.0102 0.0316 0.0506 0.0142 0.0078

-0.0047

-0.0009

-0.0115

-0.0094

-0.0099 0.0046

SONGS-3 Cycle 15 Summary Report Page 14 of 33 ATTACHMENT 1 TEST RESULTS TABLE 2 20% RADIAL POWER DISTRIBUTION ASSEMBLY MEASURED PREDICTED DIFFERENCE DIFF IPRED 161 1.272 1.277

-0.005

-0.0039 162 1.171 1.163 0.008 0.0069 163 1.275 1.267 0.008 0.0063 164 1.111 1.088 0.023 0.0211 165 0.515 0.508 0.007 0.0138 166 0.323 0.312 0.011 0.0353 167 0.952 0.916 0.036 0.0393 168 1.203 1.174 0.029 0.0247 169 1.322 1.323

-0.001

-0.0008 170 1.174 1.163 0.011 0.0095 171 1.259 1.262

-0.003

-0.0024 172 1.101 1.093 0.008 0.0073 173 1.237 1.258

-0.021

-0.0167 174 1.100 1.093 0.007 0.0064 175 1.258 1.261

-0.003

-0.0024 176 1.170 1.159 0.011 0.0095 177 1.324 1.323 0.001 0.0008 178 1.201 1.177 0.024 0.0204 179 0.940 0.917 0.023 0.0251 180 0.319 0.313 0.006 0.0192 181 0.438 0.415 0.023 0.0554 182 0.976 0.962 0.014 0.01 46 183 1.196 1.177 0.019 0.0161 184 1.269 1.267 0.002 0.0016 185 1.105 1.092 0.013 0.0119 186 1.297 1.301

-0.004

-0.0031 187 1.166 1.160 0.006 0.0052 188 1.291 1.301

-0.010

-0.0077 189 1.103 1.096 0.007 0.0064 190 1.266 1.266 0

0 191 1.206 1.174 0.032 0.0273 192 0.977 0.962 0.015 0.0156 193 0.436 0.415 0.021 0.0506 194 0.427 0.415 0.012 0.0289 195 0.930 0.917 0.013 0.0142 196 1.096 1.088 0.008 0.0074 197 1.212 1.195 0.017 0.0142 198 1.235 1.215 0.020 0.0165 199 1.338 1.348

-0.010

-0.0074 200 1.220 1.213 0.007 0.0058

SONGS-3 Cycle 15 Summary Report Page 15 of 33 ATTACHMENT 1 TEST RESULTS TABLE 2 20% RADIAL POWER DISTRIBUTION ASSEMBLY 201 202 203 204 205 206 207 208 209 210-211 212 213 214 215 216 217 MEASURED 1.187 1.083 0.927 0.426 0.314 0.522 0.927 1.186 1.072 1.161 0.870 0.505 0.310 0.436 0.850 0.843 0.423 PREDICTED 1.195 1.087 0.916 0.415 0.313 0.508 0.881 1.163 1.056 1.162 0.880 0.507 0.312 0.418 0.838 0.838 0.417 DIFFERENCE

-0.008

-0.004 0.011 0.011 0.001 0.014 0.046 0.023 0.016

-0.001

-0.010

-0.002

-0.002 0.018 0.012 0.005 0.006 DIFF / PRED

-0.0067

-0.0037 0.0120 0.0265 0.0032 0.0276 0.0522 0.0198 0.0152

-0.0009

-0.0114

-0.0039

-0.0064 0.0431 0.0143 0.0060 0.0144 SUM OF THE SQUARES OF THE DIFFERENCES =

RMSERROR=

.0154 0.0518 ALL BUNDLE POWERS MEET THE ACCEPTANCE CRITERIA BOXED VALUES ARE MOST NEGATIVE AND MOST POSITIVE VALUES FOR INCORE FLUX SYMMETRY IN TABLE 1

SONGS-3 Cycle 15 Summary Report Page 16 of 33 ATTACHMENT 1 TEST RESULTS TABLE 3 65% RADIAL POWER DISTRIBUTION PREDICTED RELATIVE POWER DENSITIES 1

2 3

4 0.413 0.835 0.836 0.414 Assy #

RPD 5

0.304 6

0.495 7

0.867 8

1.163 9

1.069 10 1.165 11 0.868 12 0.497 13 0.305 14 0.410 15 0.914 16 1.081 17 1.191 18 1.221 19 1.343 20 1.223 21 1.192 22 1.082 23 0.916 24 0.411 25 0.411 26 0.957 27

.185 28 1.264 29 1.099 30 31 1.297 1.166 32 1.297 33 1.094 34 35 36 37 1

83 0.414 100 0.836 117 0.835 134 0.413 0.5 151241091.9

.6

.9

.9 1.266 1.190 0.957 0.410 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 0.305 0.916 1.190 1.320 1.161 1.259 1.097 1.258 1.098 1.259 1.166 1.320 1.185 0.914 0.304 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 0.497 1.082 1.266 1.166 1.274 1.090 1.220 1.069 1.222 1.092 1.274 1.161 1.264 1.081 0.495 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 0.868 1.192 1.094 1.259 1.092 1.183 1.018 1.108 1.022 1.183 1.090 1.259 1.099 1.191 0.867 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 1.165 1.223 1.297 1.098 1.222 1.022 0.627 0.569 0.627 1.018 1.220 1.097 1.297 1.221 1.163 102 103 104 105 106' 107 108 109 110 111 112 113 114 115 116 1.069 1.343 1.166 1.258 1.069 1.108 0.569 0.435 0.569 1.108 1.069 1.258 1.166 1.343 1.069 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 1.163 1.221 1.297 1.097 1.220 1.018 0.627 0.569 0.627 1.022 1.222 1.098 1.297 1.223 1.165 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 0.867 1.191 1.099 1.259 1.090 1.183 1.022 1.108 1.018 1.183 1.092 1.259 1.094 1.192 0.868 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 0.4951.081 1.264 1.161 1.274 1.092 1.222 1.069 1.220 1.090 1.274 1.166 1.266 1.082 0.497 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 0.304 0.914 1.185 1.320 1.166 1.259 1.098 1.258 1.097 1.259 1.161 1.320 1.190 0.916 0.305 84 0.413 101 0.835 118 0.836 135 0.414 181 0.410 182 0.957 183 1.190 184 1.266 185" 1.094, 186 1.297 187 1.166

188, 1.297 189 1.099 190 1.264 191 1.185 192 0.957 193 0.411 194 0.411 195 0.916 196 1.082 197 1.192 198 1.223 199 1.343 200" 1.221 201 1.191 202 1.081 203 0.914 204 0.410 0.410 i

i i

205 206 0.305 0.497 207 0.868 208 209 1.165 1.069 210 1.163 211 212 0.867 0.495 213 0.304 214 -ý0215 61.216 0217 0.414 0.836 0.835 0.413

SONGS-3 Cycle 15 Summary Report Page 17 of 33 ATTACHMENT 1 TEST RESULTS TABLE 3 65% RADIAL POWER DISTRIBUTION MEASURED RELATIVE POWER DENSITIES 1

ý

.2 0

.3

ý

.4 0.424

.830 0833__0428 Assy #

RPD 5

0.325 6

7 0.515 0.902 8

-9 1.158 1.043 10 1.167 11 0.920 12 0.519 13 0.324 4

4

+

I F

I 14 0.423 15 0.926 16 17 1.085 1.192 18 19 1.214 1.324 20 1.220 21 1.198 22 1.087 23 24 0.926 0.422 25 0.433 26 0.971 27 1.188 28 29 1.257 1.089 30 31 1.285 1.161 32 1.284 33 1.082 34 1.255 35 36 37 1.189 0.964 0.430 83 0.427 100 0.841 117 0.842 134 0.427 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 0.320 0.947 1.201 1.316 1.159 1.247 1.094 1.244 1.092 1.243 1.157 1.303 1.181 0.930 0.313 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 0.520 1.136 1.281 1.165 1.264 1.078 1.202 1.049 1.203 1.076 1.255 1.138 1.257 1.108 0.509 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 0.879 1.202 1.105 1.250 1.086 1.166 1.001 1.087 1.007 1.170 1.082 1.240 1.096 1.186 0.867 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 1.162 1.203 1.279 1.072 1.204 1.005 0.629 0.563 0.633 1.017 1.207 1.076 1.276 1.197 1.150 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 1.073 1.326 1.158 1.235 1.062 1.100 0.579 0.445 0.579 1.101 1.065 1.239 1.156 1.319 1.066 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 1.164 1.212 1.283 1.072 1.207 1.018 0.634 0.564 0.632 1.009 1.209 1.080 1.281 1.203 1.158 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 0.882 1.208 1.111 1.251 1.089 1.175 1.011 1.092 1.009 1.173 1.089 1.250 1.104 1.197 0.876 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 0.522 1.141 1.282 1.160 1.267 1.084 1.209 1.053 1.208 1.085 1.265 1.157 1.273 1.122 0.516 166 167 168 169 170 171 172 173 174 175 176 177 178

.179 180 0.321 0.949 1.198 1.316 1.167 1.253 1.097 1.245 1.095 1.251 1.160 1.315 1.196 0.940 0.318 84 0.418 101 0.833 118 0.837 135 0.427 181 182 0.435 0.970 183 1.188 184 1.262 185 1.094 186 187 188 189 1.288 1.152 1.281i" 1.090 190 1.257 191 192 193 1.195 0.971 0.432 194 0.424 195 0.926 196 1.092 197-1.206

'198 199 200",

201 1.224 1.323 1.206 1.177 202 1.077 203 204 0.924 0.423 205 0.320 206 0.522 207 0.929 208 209 210 211 1.175 1.054 1.145 0.861 212 0.503 213 0.321 214 215 216 217 0.43 1 0.83 8 10.829 10.415

SONGS-3 Cycle 15 Summary Report Page 18 of 33 ATTACHMENT 1 TEST RESULTS TABLE 3 65% RADIAL POWER DISTRIBUTION ASSEMBLY 1

2 3

4 5

6 7

8 9

10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 MEASURED 0.424 0.830 0.833 0.428 0.325 0.515 0.902 1.158 1.043 1.167 0.920 0.519 0.324 0.423 0.926 1.085 1.192 1.214 1.324 1.220 1.198 1.087 0.926 0.422 0.433 0.971 1.188 1.257 1.089 1.285 1.161 1.284 1.082 1.255 1.189 0.964 0.430 0.320 0.947 1.201 PREDICTED 0.4128 0.8354 0.8362 0.4136 0.3043 0.4954 0.8665 1.1626 1.0689 1.1648 0.8679 0.4967 0.3050 0.4102 0.9138 1.0810 1.1913 1.2207 1.3431 1.2229 1.1918 1.0825 0.9158 0.4110 0.4110 0.9570 1.1854 1.2640 1.0990 1.2974 1.1659 1.2968 1.0945 1.2662 1.1901 0.9570 0.4102 0.3050 0.9158 1.1901 DIFFERENCE 0.0112

-0.0054

-0.0032 0.0144 0.0207 0.0196 0.0355

-0.0046

-0.0259 0.0022 0.0521 0.0223 0.0190 0.0128 0.0122 0.0040 0.0007

-0.0067

-0.0191

-0.0029 0.0062 0.0045 0.0102 0.0110 0.0220 0.0140 0.0026

-0.0070

-0.0100

-0.0124

-0.0049

-0.0128

-0.0125

-0.0112

-0.0011 0.0070 0.0198 0.0150 0.0312 0.0109 DIFF / PRED 0.0271

-0.0065

-0.0038 0.0348 0.068 0.0396 0.041

-0.004

-0.0242 0.0019 0.06 0.0449 0.0623 0.0312 0.0134 0.0037 0.0006

-0.0055

-0.0142

-0.0024 0.0052 0.0042 0.0111 0.0268 0.0535 0.0146 0.0022

-0.0055

-0.0091

-0.0096

-0.0042

-0.0099

-0.0114

-0.0088

-0.0009 0.0073 0.0483 0.0492 0.0341 0.0092

SONGS-3 Cycle 15 Summary Report Page 19 of 33 ATTACHMENT 1 TEST RESULTS TABLE 3 POWER DISTRIBUTION ASSEMBLY 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 65% RADIAL MEASURED 1.316 1.159 1.247 1.094 1.244 1.092 1.243 1.157 1.303 1.181 0.930 0.313 0.520 1.136 1.281 1.165 1.264 1.078 1.202 1.049 1.203 1.076 1.255 1.1.38 1.257 1.108 0.509 0.879 1.202 1.105 1.250 1.086 1.166 1.00 1 1.087 1.007 1.170 1.082 1.240 1.096 PREDICTED 1.3204 1.1607 1.2586 1.0975 1.2582 1.0976 1.2594 1.1664 1.3204 1.1854 0.9 138 0.3043 0.4967 1.0825 1.2662 1.1664 1.2737 1.0897 1.2200 1.0691 1.2224 1.09 19 1.2737 1.1607 1.2640 1.0810 0.4954 0.8679 1.1918 1.0945 1.2594 1.09 19 1.1827 1.01 82 1.1076 1.02 16 1.1827 1.0897 1.2586 1.0990 DIFFERENCE

-0.0044

-0.0017

-0.0116

-0.0035

-0.0142

-0.0056

-0.0164

-0.0094

-0.0174

-0.0044 0.01 62 0.0087 0.0233 0.0535 0.01 48

-0.0014

-0.0097

-0.0117

-0.0180

-0.0201

-0.0194

-0.0159

-0.0187

-0.0227

-0.0070 0.0270 0.01 36 0.0111 0.01 02 0.01 05

-0.0094

-0.0059

-0.0167

-0.0172

-0.0206

-0.0146

-0.0127

-0.0077

-0.0186

-0.0030 DIFF / PRED

-0.0033

-0.001 5

-0.0092

-0.0032

-0.0113

-0.0051

-0.01 30

-0.0081

-0.0132

-0.0037 0.0177 0.0286 0.0469,.

0.0494 0.0117

-0.0012

-0.0076

-0.0107

-0.0148

-0.0188

-0.0159

-0.0146

-0.0147

-0.0196

-0.0055 0.0250 0.0275 0.0128 0.0086 0.0096

-0.0075

-0.0054

-0.0141

-0.0169

-0.0186

-0.0143

-0.0107

-0.0071

-0.0148

-0.0027

SONGS-3 Cycle 15 Summary Report Page 20 of 33 ATTACHMENT 1 TEST RESULTS TABLE 3 POWER DISTRIBUTION ASSEMBLY 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 65% RADIAL MEASURED 1.186 0.867 0.427 0.418 1.162 1.203 1.279 1.072 1.204 1.005 0.629 0.563 0.633 1.017 1.207 1.076 1.276 1.197 1.150 0.841 0.833 1.073 1.326 1.158 1.235 1.062 1.100 0.579 0.445 0.579 1.101 1.065 1.239 1.156 1.319 1.066 0.842 0.837 1.164 1.212 PREDICTED 1.1913 0.8665 0.4136 0.4128 1.1648 1.2229 1.2968 1.0976 1.2224 1.0216 0.6265 0.5687 0.6265 1.0182 1.2200 1.0975 1.2974 1.2207 1.1626 0.8362 0.8354 1.0689 1.3431 1.1659 1.2582 1.0691 1.1076 0.5687 0.4348 0.5687 1.1076 1.0691 1.2582 1.1659 1.3431 1.0689 0.8354 0.8362 1.1626 1.2207 DIFFERENCE

-0.0053 0.0005 0.0134 0.0052,

-0.0028

-0.0199

-0.0178

-0.0256

-0.0184

-0.0166 0.0025

-0.0057 0.0065

-0.0012

-0.0130

-0.0215

-0.0214

-0.0237

-0.0126 0.0048

-0.0024 0.0041

-0.0171

-0.0079

-0.0232

-0.0071

-0.0076 0.0103 0.0102 0.0103

-0.0066

-0.0041

-0.0192

-0.0099

-0.0241

-0.0029 0.0066 0.0008 0.0014

-0.0087 DIFF / PRED

-0.0044 0.0006 0.0324 0.0126

-0.0024

-0.0163

-0.0137

-0.0233

-0.0151

-0.0162 0.0040

-0.0100 0.0104

-0.0012

-0.0107

-0.0196

-0.0165

-0.0194

-0.0108 0.0057-.,

-0.0029 0.0038

-0.0127

-0.0068

-0.0184

-0.0066

-0.0069 0.0181 0.0235 0.0181

-0.0060

-0.0038

-0.0153

-0.0085

-0.0179

-0.0027 0.0079 0.0010 0.0012

-0.0071

SONGS-3 Cycle 15 Summary Report Page 21 of 33 ATTACHMENT 1 TEST RESULTS TABLE 3 POWER DISTRIBUTION ASSEMBLY 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 65% RADIAL MEASURED 1.283 1.072 1.207 1.018 0.634 0.564 0.632 1.009 1.209 1.08 1.28 1 1.203 1.158 0.427 0.427 0.882 1.208 1.111 1.251 1.089 1.175 1.011 1.092 1.009 1.173 1.089 1.250 1.104 1.197 0.876 0.522 1.141 1.282 1.160 1.267 1.084 1.209 1.053 1.208 1.085 PREDICTED 1.2974 1.0975 1.2200 1.01 82 0.6265 0.5687 0.6265 1.0216 1.2224 1.0976 1.2968 1.2229 1.1648 0.4128 0.4136 0.8665 1.1913 1.0990 1.2586 1.0897 1.1827 1.02 16 1.1076 1.01 82 1.1827 1.09 19 1.2594 1.0945 1.1918 0.8679 0.4954 1.08 10 1.2640 1.1607 1.2737 1.09 19 1.2224 1.0691 1.2200 1.0897 DIFFERENCE

-0.0144

-0.0255

-0.0130

-0.0002 0.0075

-0.0047 0.0055

-0.01 26

-0.01 34

-0.0176

-0.0158

-0.0199

-0.0068 0.01 42 0.01 34 0.01 55 0.01 67 0.01 20

-0.0076

-0.0007

-0.0077

-0.0106

-0.0156

-0.0092

-0.0097

-0.0029

-0.0094 0.0095 0.0052 0.0081 0.0266 0.0600 0.01 80

-0.0007

-0.0067

-0.0079

-0.0134

-0.0161

-0.01 20

-0.0047 DIFF / PRED

-0.0111

-0.0232

-0.0107

-0.0002 0.0120

-0.0083 0.0088

-0.0123

-0.0110

-0.0160

-0.0122

-0.0163

-0.0058 0.0344 0.0324 0.0179 0.01 40 0.01 09

-0.0060

-0.0006

-0.0065

-0.0104

-0.01 41

-0.0090

-0.0082

-0.0027

-0.0075 0.0087 0.0044 0.0093 0.0537 0.0555 0.01 42

-0.0006

-0.0053

-0.0072

-0.0110

-0.0151

-0.0098

-0.0043

SONGS-3 Cycle 15 Summary Report Page 22 of 33 ATTACHMENT 1 TEST RESULTS TABLE 3 POWER DISTRIBUTION ASSEMBLY 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 65% RADIAL MEASURED 1.265 1.157 1.273 1.122 0.516 0.321 0.949 1.198 1.316 1.167 1.253 1.097 1.245 1.095 1.251 1.160 1.315 1.196 0.940

- 0.318 0.435 0.970 1.188 1.262 1.094 1.288 1.152 1.281 1.090 1.257 1.195 0.971 0.432 0.424 0.926 1.092 1.206 1.224 1.323 1.206 PREDICTED 1.2737 1.1664 1.2662 1.0825 0.4967 0.3043 0.9138 1.1854 1.3204 1.1664 1.2594 1.0976 1.2582 1.0975 1.2586 1.1607 1.3204 1.1901 0.9158 0.3050 0.4102 0.9570 1.1901 1.2662 1.0945 1.2968, 1.1659 1.2974 1.0990 1.2640 1.1854 0.9570 0.4110 0.4110 0.9158 1.0825 1.1918 1.2229 1.3431 1.2207 DIFFERENCE

-0.0087

-0.0094 0.0068 0.0395 0.0193 0.0167 0.0352 0.0126

-0.0044 0.0006

-0.0064

-0.0006

-0.0132

-0.0025

-0.0076

-0.0007

-0.0054 0.0059

-0.0242 0.0130 0.0248 0.0130

-0.0021

-0.0042

-0.0005

-0.0088

-0.0139

-0.0164

-0.0090

-0.0070 0.0096 0.0140 0.0210 0.0130 0.0102 0.0095 0.0142 0.0011

-0.0201

-0.0147 DIFF / PRED

-0.0068

-0.0081 0.0054 0.0365 0.0389 0.0549 0.0385 0.0106

-0.0033 0.0005

-0.0051

-0.0005

-0.0105

-0.0023

-0.006

-0.0006

-0.0041 0.0050 0.0264 0.0426 0.0605 0.0136

-0.0018

-0.0033

-0.0005

-0.0068

-0.0119

-0.0126

-0.0082

-0.0055 0.0081 0.0146 0.0511 0.0316 0.0111 0.0088 0.0119 0.0009

-0.0150

-0.0120

SONGS-3 Cycle 15 Summary Report Page 23 of 33 ATTACHMENT 1 TEST RESULTS TABLE 3 POWER DISTRIBUTION ASSEMBLY 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 65% RADIAL MEASURED 1.177 1.077 0.924 0.423 0.32 0.522 0.929 1.175 1.054 1.145 0.861 0.503 0.321 0.431 0.838 0.829 0.415 PREDICTED 1.1913 1.0810 0.9138 0.4102 0.3050 0.4967 0.8679 1.1648 1.0689 1.1626 0.8665 0.4954 0.3043 0.4136 0.8362 0.8354 0.4128 DIFFERENCE

-0.0143

-0.0040 0.0102 0.0128 0.0150 0.0253 0.0611 0.0102

-0.0149

-0.0176

-0.0055 0.0076 0.0167 0.0174 0.0018

-0.0064 0.0022 DIFF / PRED

-0.0120

-0.0037 0.0112 0.0312 0.0492 0.0509 0.0704 0.0088

-0.0139

-0.0151

-0.0063 0.0153 0.0549 0.0421 0.0022

-0.0077 0.0053 SUM OF THE SQUARES RMSERROR=

.0156 OF THE DIFFERENCES =

.0530 ALL BUNDLE POWERS MEET THE ACCEPTANCE CRITERIA

ATTACHMENT 1 TEST RESULTS TABLE 4 65% CORE AVERAGE AXIAL POWER SONGS-3 Cycle 15 Summary Report Page 24 of 33 DISTRIBUTION PCT.

HT.

100 (TOP) 98 96 94 92 90 88 86 84 82 80 78 76 74 72 70 68 66 64 62 60 58 56 54 52 50 48 46 44 42 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8

6 4

2 0 (BOT)

MEASURED VALUE 0.4028 0.5130 0.6149 0.7073 0.7894 0.8608 0.9217 0.9724 1.0138 1.0468 1.0726 1.0926 1.1079 1.1197 1.1292 1.1372 1.1442 1.1507 1.1569 1.1628 1.1681 1.1727 1.1761 1.1781 1.1785 1.1770 1.1737 1.1686 1.1619 1.1540 1.1452 1.1359 1.1264 1.1169 1.1076 1.0981 1.0883 1.0774 1.0647 1.0491 1.0293 1.0042 0.9725 0.9330 0.8845 0.8264 0.7582 0.6797 0.5912 0.4935 0.3878 PREDICTED VALUE 0.388 0.540 0.678 0.770 0.849 0.914 0.965 1.008 1.043 1.072 1.096 1.116 1.133 1.147 1.158 1.167 1.174 1.179 1.183 1.186 1.187 1.188 1.186 1.184 1.180 1.175 1.169 1.163 1.155 1.147 1.137 1.127 1.114 1.101 1.087 1.072 1.055 1.036 1.016 0.994 0.970 0.943 0.912 0.876 0.836 0.789 0.734 0.667 0.589 0.469 0.338 DIFFERENCE 0.0148

-0.0270

-0.0631

-0.0627

-0.0596

-0.0532

-0.0433

-0.0356

-0.0292

-0.0252

-0.0234

-0.0234

-0.0251

-0.0273

-0.0288

-0.0298

-0.0298

-0.0283

-0.0261

-0.0232

-0.0189

-0.0153

-0.0099

-0.0059

-0.0015 0.0020 0.0047 0.0056 0.0069 0.0070 0.0082 0.0089 0.0124 0.0159 0.0206 0.0261 0.0333 0.0414 0.0487 0.0551 0.0593 0.0612 0.0605 0.0570 0.0485 0.0374 0.0242 0.0127 0.0022 0.0245 0.0498 SUM OF THE SQUARES OF THE RMS ERROR =.0342 DIFFERENCES =.0595

SONGS-3 Cycle 15 Summary Report Page 25 of 33 ATTACHMENT 1 TEST RESULTS TABLE 5 100% RADIAL POWER DISTRIBUTION PREDICTED RELATIVE POWER DENSITIES 0.41 2

3 4

0.836 0.836 0.418 7

Assy #

RPD 5

6 7

8 9

10 1.065 1.157 11 0.868 12 0.502 13 0.310

.0309 0500 0866 1.155 22 23 24 14 15 0.91 16 1.077 17 1.184 18 1.213 19 1.33 1 20 1.215 21

.184 22 1.078 23 0.916 24 0.416 4

1 0.418 0.,6

.1 I.

4

,-444-4 25 26 0.416 0.955 27 1.178 28 1.255 29 1.098 30 1.29 1 31 1.164 32 1.290 33 1.093 34 1.257 35 1.183 36 0.955 37 0.415 83 0.418 100 0.836 117 0.836 134 0.417 38 39 40 41 42 43 44 45 46 47 48

49.

50.,

51 52 0.31 0.916 1.183 1.309 1.158 1.256 1.101 1.258 1.101 1.257 1.164 1.309 1.178 0.914 0.309 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 0.502 1.078 1.257 1.164 1.271 1.094 1.224 1.077 1.226 1.096 1.271 1.158 1.255 1.077 0.500 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 0.868 1.184 1.093 1.257 1.096 1.188 1.030 1.120 1.033 1.188 1.094 1.256 1.098 1.184 0.866 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 1.157 1.215 1.290 1.101 1.226 1.033 0.644 0.588 0.644 1.030 1.224 1.101 1.291 1.213 1.155 102 103 104 105 106 107 108 109 110 i11 112 113 114 115 116 1.065 1.331 1.164 1.258 1.077 1.120 0.588 0.454 0.588 1.120 1.077 1.258 1.164 1.331 1.065 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 1.155 1.213 1.291 1.101 1.224 1.030 0.644 b.588 0.644 1.033 1.226 1.101 1.290 1.215 1.157 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 0.866 1.184 1.098 1.256 1.094 1.188 1.033 1.120 1.030 1.188 1.096 1.257 1.093 1.184 0.868 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 0.500 1.077 1.255 1.158 1.271 1.096 1.226 1.077 1.224 1.094 1.271 1.164 1.257 1.078 0.502 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 0.309 0.914 1.178 1.309 1.164 1.257 1.101 1.258 1.101 1.256 1.158 1.309 1.183 0.916 0.310 84 0.417 101 0.836 118 0.836 135 0.418 181 182 183 184 185 186 187 1.164 188 1.291

-,189 1.098 190 1.255 191 1.178 192 0.955 193 0.416 0415 0955 1.183 1.257 1.093 1.290 194 0.416 195 0.9 16 196 1.078 197 1.184 198 1.215 199 1.331 200 1.213 201 1.184 202 1.077 203 0.914 204 0.415 4

+

+

+

4 4

1 4

.4.

205 0.310 206 0.502 207 0.868 208 1.157 209 1.065 210 1.155 211 0.866 212 0.500 213 0.309 214 215

ý 216 0217 0.418 0.836 0.836 0.417

SONGS-3 Cycle 15 Summary Report Page 26 of 33 ATTACHMENT 1 TEST RESULTS TABLE 5 100% RADIAL POWER DISTRIBUTION MEASURED RELATIVE POWER DENSITIES 1

2 3

0.416 0.815__ 0.81 4

9 0.422 Assy #

RPD 5

0.333 6

0.512 7

0.886 8

143 9

1.029 10 1.155 11 0.912 12 0.518 13 0.329 1

4-4

+

+

F F

I t

I 14 0.421 15 0.924 16 1.083 17 1.187 18

.203 19 1.317 20 1.210 21 1.195 22 1.086 23 0.923 24 0.419 1

+

+

I

+

t I

t t

1 t

1 1

25 0.438 26 0.968 27

.175 28 1.255 29 1.084 30 1.285 31 1.156 32 1.284 33 1.076 34 1.253 35 36 1.175 0.960 37 0.434 1

83 0.431 100 0.836 117' 0.836 134 0.43 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 0.319 0.944 1.193 1.315 1.155 1.251 1.094 1.251 1.092 1.247 1.153 1.3 1.173 0.927 0.313 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67

.0.518 1.128 1.281 1.163 1.27 1.082 1.214 1.059 1.215 1.08 1.259 1.133 1.256 1.103 0.507 68 69 70 71 72 73 74 75 76 77 n8 79 80 81 82 0.882 1.203 1.103 1.257 1.092 1.182 1.014 1.107 1.019 1.184 1.086 1.244 1.091 1.184 0.867 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 1.161 1.199 1.284 1.077 1.218 1.023 0.643 0.593 0.646 1.033 1.220 1.079 1.275 1.182 1.144 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 1.066 1.323 1.156 1.245 1.070 1.117 0.590 0.460 0.59 1.118 1.072 1.247 1.15 1.311 1.055 li9 120 121 122 123 124 125 126 127 128 129 130 131 132 133 1.160 1.199 1.285 1.076 1.221 1.034 0.647 0.593 0.645 1.026 1.222 1.083 1.280 1.188 1.152 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 0.882 1.205 1.107 1.255 1.093 1.189 1.022 1.111 1.021 1.187 1.093 1.255 1.099 1.1,94 0.876 151 152 153 154 155 156

157, 158 159 160 161 162 163 164 165 0.519 1.132 1.278 1.154 1.272 1.088 1.220 1.060 1.218 1.089 1.270 1.151 1.272 1.118 0.514 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 0.319 0.944 1.188 1.312 1.161 1.256 1.096 1.249 1.094 1.253 1.156 1.315 1.190 0.939 0.317 84 0.423 101 0.826 118 0.829 135 0.43 181 0.438 182 0.965 183 184 1.173 1.259 185 1.087 186 187 1.285 1.143 188.,

1.278>

, 189 1.082 190 1.257 191 1.188 192 193 0.970 0.437

-I 1-1 1-

-~

  • ..-.--.-I----------1 1

t

-~

194 0.421 195 0.922 196 1.090 197 1.202 198 1.212 199 1.313 200 1.195 201 1.174 202 1.077 203 0.923 204 0.421 205 206 0.326 0.520 207 0.920 208 209

.161 1.036 210 1.133 211 0.856 212 0.501 213 0.323 1

214 215 1 216 02179 0.424 0.822 0.814 0.409

SONGS-3 Cycle 15 Summary Report Page 27 of 33 ATTACHMENT 1 TEST RESULTS TABLE 5 100% RADIAL POWER DISTRIBUTION ASSEMBLY MEASURED PREDICTED DIFFERENCE DIFF / PRED 1

0.416 0.4168

-0.0008

-0.0019 2

0.815 0.8356

-0.0206

-0.0247 3

0.819 0.8363

-0.0173

-0.0207 4

0.422 0.4176 0.0044 0.0105 5

0.333 0.3092 0.0238 0.0770 6

0.512 0.5003 0.0117 0.0234 7

0.886 0.8663 0.0197 0.0227 8

1.143 1.1552

-0.0122

-0.0106 9

1.029 1.0646

-0.0356

-0.0334 10 1.155 1.1572

-0.0022

-0.0019 11 0.912 0.8675 0.0445 0.0513 12 0.518 0.5015 0.0165 0.0329 13 0.329 0.3100 0.0190 0.0613 14 0.421 0.4150 0.0060 0.0145 15 0.924 0.9138 0.0102 0.0112 16 1.083 1.0765 0.0065 0.0060 17 1.187 1.1840 0.0030 0.0025 18 1.203 1.2130

-0.0100

-0.0082 19 1.317 1.3308

-0.0138

-0.0104 20 1.210 1.2151

-0.0051

-0.0042 21 1.195 1.1844 0.0106 0.0089 22 1.086 1.0779 0.0081 0.0075 23 0.923 0.9158 0.0072 0.0079 24 0.419 0.4158

.0.0032 0.0077 25 0.438 0.4158 0.0222 0.0534 26 0.968 0.9553 0.0127 0.0133 27 1.175 1.1780

-0.0030

-0.0025 28 1.255 1.2552

-0.0002

-0.0002 29 1.084 1.0977

-0.0137

-0.0125 30 1.285 1.2907

-0.0057

-0.0044 31 1.156 1.1637

-0.0077

-0.0066 32 1.284 1.2900

-0.0060

-0.0047 33 1.076 1.0933

-0.0173

-0.0158 34 1.253 1.2573

-0.0043

-0.0034 35 1.175 1.1825

-0.0075

-0.0063 36 0.96 0.9553 0.0047 0.0049 37 0.434 0.4150 0.0190 0.0458 38 0.319 0.3100 0.0090 0.0290 39 0.944 0.9158 0.0282 0.0308 40 1.193 1.1825 0.0105 0.0089

SONGS-3 Cycle 15 Summary Report Page 28 of 33 ATTACHMENT 1 TEST RESULTS TABLE 5 100% RADIAL POWER DISTRIBUTION ASSEMBLY MEASURED PREDICTED DIFFERENCE DIFF / PRED 41 1.315 1.3091 0.0059 0.0045 42 1.155 1.1581

-0.0031

-0.0027 43 1.251 1.2560

-0.0050

-0.0040 44 1.094 1.1007

-0.0067

-0.0061 45 1.251 1.2576

-0.0066

-0.0052 46 1.092 1.1008

-0.0088 70.0080 47 1.247 1.2567

-0.0097

-0.0077 48 1.153 1.1636

-0.0106

-0.0091 49 1.300 1.3091

-0.0091

-0.0070 50 1.173 1.1780

-0.0050

-0.0042 51 0.927 0.9138 0.0132 0.0144 52 0.313 0.3092 0.0038 0.0123 53 0.518 0.5015 0.0165 0.0329 54 1.128 1.0779 0.0501 0.0465 55 1.281 1.2573 0.0237 0.0188 56 1.163 1.1636

-0.0006

-0.0005 57 1.270 1.2707

-0.0007

-0.0006 58 1.082 1.0943

-0.0123

-0.0112 59 1.214 1.2235

-0.0095

-0.0078 60 1.059 1.0768

-0.0178

-0.0165 61 1.215 1.2258

-0.0108

-0.0088 62 1.080 1.0964

-0.0164

-0.0150 63 1.259 1.2707

-0.0117

-0.0092 64 1.133 1.1581

-0.0251

-0.0217 65 1.256 1.2552 0.0008 0.0006 66 1.103 1'.0765 0.0265 0.0246 67 0.507 0.5003 0.0067 0.0134 68 0.882 0.8675 0.0145 0.0167 69 1.203 1.1844 0.0186 0.0157 70 1.103 1.0933 0.0097 0.0089 71 1.257 1.2567 0.0003 0.0002 72 1.092 1.0964

-0.0044

-0.0040 73 1.182 1.1882

-0.0062

-0.0052 74 1.014 1.0300

-0.0160

-0.0155 75 1.107 1.1196

-0.0126

-0.0113 76 1.019 1.0333

-0.0143

-0.0138 77 1.184 1.1882

-0.0042

-0.0035 78 1.086 1.0943

-0.0083

-0.0076 79 1.244 1.2560

-0.0120

-0.0096 80 1.091 1.0977

-0.0067

-0.0061

SONGS-3 Cycle 15 Summary Report Page 29 of 33 ATTACHMENT 1 TEST RESULTS TABLE 5 100% RADIAL POWER DISTRIBUTION ASSEMBLY MEASURED PREDICTED DIFFERENCE DIFF / PRED 81 1.184 1.1840 0

0 82 0.867 0.8663 0,0007 0.0008 83 0.431 0.4176 0.0134 0.0321 84 0.423 0.4168 0.0062 0.0149 85 1.161 1.1572 0.0038 0.0033 86 1.199 1.2151

-0.0161

-0.0132 87 1.284 1.2900

-0.0060

-0.0047 88 1.077 1.1008

-0.0238

-0.0216 89 1.218 1.2258

-0.0078

-0.0064 90 1.023 1.0333

-0.0103

-0.0100 91 0.643 0.6441

-0.0011

-0.0017 92 0.593 0.5876 0.0054 0.0092 93 0.646 0.6441 0.0019 0.0029 94 1.033 1.0300 0.0030

'0.0029 95 1.220 1.2235

-0.0035

-0.0029 96 1.079 1.1007

-0.0217

-0.0197 97 1.275 1.2907

-0.0157

-0.0122 98 1.182 1.2130

-0.0310

-0.0256 99 1.144 1.1552

-0.0112

-0.0097 100 0.836 0.8363

-0.0003

-0.0004 101 0.826 0.8356

-0.0096

-0.0115 102 1.066 1.0646 0.0014 0.0013 103 1.323 1.3308

-0.0078

-0.0059 104 1.156 1.1637

-0.0077

-0.0066 105 1.245 1.2576

-0.0126

-0.0100 106 1.070 1.0768

-0.0068

-0.0063 107 1.117 1.1196

-0.0026

-0.0023 108 0.590 0.5876 0.0024 0.0041 109 0.460 0.4536 0.0064 0.0141

110, 0.590 0.5876 0.0024 0.0041 111 1.118 1.1196

-0.0016

-0.0014 112 1.072 1.0768

-0.0048,

-0.0045 113 1.247 1.2576

-0.0106

-0.0084 114 1.150 1.1637

-0.0137

-0.0118 115 1.311 1.3308

-0.0198

-0.0149 116 1.055 1.0646

-0.0096

-0.0090 117 0.836 0.8356 0.0004 0.0005 118 0.829 0.8363

-0.0073

-0.0087 119 1.160 1.1552 0.0048 0.0042 120 1.199 1.2130

-0.014

-0.0115

SONGS-3 Cycle 15.Summary Report Page 30 of 33 ATTACHMENT 1 TEST RESULTS TABLE 5 100% RADIAL POWER DISTRIBUTION ASSEMBLY MEASURED PREDICTED DIFFERENCE DIFF / PRED 121 1.285 1.2907

-0.0057

-0.0044 122 1.076 1.1007

-0.0247

-0.0224 123 1.221 1.2235

-0.0025

-0.0020 124 1.034, 1.0300 0.0040 0.0039 125 0.647 0.6441 0.0029 0.0045 126 0.593 0.5876 0.0054 0.0092 127 0.645 0.6441 0.0009 0.0014 128 1.026 1.0333

-0.0073

-0.0071 129 1.222 1.2258

-0.0038

-0.0031 1.30 1.083 1.1008

-0.0178

-0.0162 131 1.280 1.2900

-0.0100

-0.0078 132 1.188 1.2151

-0.0271

-0.0223 133 1.152 1.1572

-0.0052

-0.0045 134 0.430 0.4168 0.0132 0.0317 135 0.430 0.4176 0.0124 0.0297 136 0.882 0.8663 0.0157 0.0181 137 1.205 1.1840 0.0210 0.0177 138 1.107 1.0977 0.0093 0.0085 139 1.255 1.2560

-0.0010

-0.0008 140 1.093 1.0943

-0.0013

-0.0012 141 1.189 1.18.82 0.0008 0.0007 142 1.022 1.0333

-0.0113

-0.0109 143 1.111 1.1196

-0.0086

-0.0077 144 1.021 1.0300

-0.0090

-0.0087 145 1.187 1.1882

-0.0012

-0.0010 146 1.093 1.0964

-0.0034

-0.0031 147 1.255 1.2567

-0.0017

-0.0014 148 1.099 1.0933 0.0057 0.0052 149 1.194 1.1844 0.0096 0.0081.

150 0.876 0.8675 0.0085 0.0098 151 0.519 0.5003 0.0187 0.0374 152 1.132 1.0765 0.0555 0.0516 153 1.278 1.2552 0.0228 0.0182 154 1.154 1.1581

-0.0041

-0.0035 155 1.272 1.2707 0.0013 0.0010 156 1.088 1.0964

-0.0084

-0.0077 157 1.220 1.2258

-0.0058

-0.0047 158 1.060 1.0768

-0.0168

-0.0156 159 1.218 1.2235

-0.0055

-0.0045 160 1.089 1.0943

-0.0053

-0.0048

SONGS-3 Cycle 15 Summary Report Page 31 of 33 ATTACHMENT 1 TEST RESULTS TABLE 5 100% RADIAL POWER DISTRIBUTION ASSEMBLY MEASURED PREDICTED DIFFERENCE DIFF / PRED 161 1.270 1.2707

-0.0007

-0.0006 162 1.151 1.1636

-0.0126

-0.0108 163 1.272 1.2573 0.0147 0.0117 164 1.118 1.0779 0.0401 0.0372 165 0.514 0.5015 0.0125 0.0249 166 0.319 0.3092 0.0098 0.0317 167 0.944 0.9138 0.0302 0.0330 168 1.188 1.1780 0.01 0.0085 169 1.312 1.3091 0.0029 0.0022 170 1.161 1.1636

-0.0026

-0.0022 171 1.256 1.2567

-0.0007

-0.0006 172 1.096 1.1008

-0.0048

-0.0044 173 1.249 1.2576

-0.0086

-0.0068 174 1.094 1.1007

-0.0067

-0.0061 175 1.253 1.256

-0.003

-0.0024 176 1.156 1.1581

-0.0021

-0.0018 177 1.315 1.3091 0.0059 0.0045 178 1.190 1.1825 0.0075 0.0063 179 0.939 0.9158 0.0232 0.0253 180 0.317 0.3100 0.007 0.0226 181 0.438 0.41 50 0.023 0.0554 182 0.965 0.9553 0.0097 0.01 02 183 1.173 1.1825

-0.0095

-0.0080 184 1.259 1.2573 0.0017 0.0014 185 1.087 1.0933

-0.0063

-0.0058 186 1.285 1.2900

-0.005

-0.0039 187 1.143 1.1637

-0.0207

-0.0178 188 1.278 1.2907

-0.0127

-0.0098 189 1.082 1.0977

-0.0157

-0.0143 190 1.257 1.2552 0.0018 0.0014 191 1.188 1.1780 0.01 0.0085 192 0.970 0.9553 0.0147 0.0154 193 0.437 0.4158 0.0212 0.0510 194 0.421 0.4158 0.0052 0.0125 195 0.922 0.9158 0.0062 0.0068 196 1.090 1.0779 0.0121 0.0112 197 1.202 1.1844 0.0176 0.0149 198 1.212 1.2151

-0.0031

-0.0026 199 1.313 1.3308

-0.0178

-0.0134 200 1.195 1.2130

-0.0180

-0.0148

SONGS-3 Cycle 15 Summary Report Page 32 of 33 ATTACHMENT 1 TEST RESULTS TABLE 5 100% RADIAL POWER DISTRIBUTION ASSEMBLY 201 202 20,3 204 205 206 207 208 209 210 211 212 213 214 215 216 217 MEASURED 1.174 1.077 0.923 0.421 0.326 0.520 0.920 1.161 1.036 1.133 0.856 0.501 0.323 0.424 0.822 0.814 0.409 PREDICTED 1.1840 1.0765 0.9138 0.4150 0.3100 0.5015 0.8675 1.1572 1.0646 1.1552 0.8663 0.5003 0.3092 0.4176 0.8363 0.8356 0.4168 DIFFERENCE

-0.0100 0.0005 0.0092 0.0060 0.0160 0.0185 0.0525 0.0038

-0.0286

-0.0222

-0.0103 0.0007 0.0138 0.0064

-0.0143

-0.0216

-0.0078 DIFF / PRED

-0.0084 0.0005 0.0101 0.0145 0.0516 0.0369 0.0605 0.0033

-0.0269

-0.0192

-0.0119 0.0014 0.0446 0.0153

-0.0171

-0.0258

-0.0187 SUM OF THE SQUARES OF THE DIFFERENCES RMSERROR=

.0142

.0438 ALL BUNDLE POWERS MEET THE ACCEPTANCE CRITERIA

SONGS.-3 Cycle 15 Summary Report Page 33 of 33 ATTACHMENT 1 TEST RESULTS TABLE 6 100% CORE AVERAGE AXIAL POWER DISTRIBUTION POT.

HT, 100 (TOP) 98 96 94 92 90 88 86 84 82 80 78 76 74 72 70 68 66 64 62 60 58 56 54 52 50 48 46 44 42 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8

6 4

2 0 (BOT)

MEASURED VALUE 0.3926 0.4987 0.5965 0.6849 0.7631 0.8309 0.8884 0.9362 0.9749 1.0058 1.0301 1.0490 1.0638 1.0758 1.0860

  • 1.0951 1.1038 1.1123 1.1208 1.1291 1.1371 1.1444 1.1506 1.1555 1.1587 1.1600 1.1597 1.1576 1.1543 1.1500 1.1451 1.1401 1.1354 1.1311 1.1274 1.1239 1.1202 1.1155 1.1089 1.0991 1.0846 1.0640 1.0358 0.9985 0.9509 0.8920 0.8214 0.7389 0.6448 0.5399 0.4257 PREDICTED VALUE 0.358 0.494 0.619 0.705 0.779 0.84 1 0.892 0.935 0.972 1.004 1.030 1.052 1.073 1.090 1.106 1.119 1.131 1.142 1.151 1.159 1.165 1.170 1.174 1.177 1.179 1.179 1.179 1.177 1.174 1.171 1.166 1.160 1.152 1.143 1.133 1.121 1.108 1.093 1.075 1.055 1.033 1.007 0.978 0.943 0.902 0.854 0.795 0.725 0.641 0.512 0.371 DIFFERENCE 0.0346 0.0047

-0.0225

-0.0201

-0.01 59

-0.0101

-0.0036 0.0012 0.0029 0.0018 0.0001

-0.0030

-0.0092

-0.0142

-0.0200

-0.0239

-0.0272

-0.0297

-0.0302

-0.0299

-0.0279

-0.0256

-0.0234

-0.0215

-0.0203

-0.0190

-0.0193

-0.0194

-0.0197

-0.0210

-0.0209

-0.0199

-0.0166

-0.0119

-0.0056 0.0029 0.0122 0.0225 0.0339 0.0441 0.0516 0,0570 0.0578 0.0555 0.0489 0.0380 0.0264 0.0 139 0.0038 0.0279 0.0547 SUM OF THE SQUARES OF THE DIFFERENCES = 0.0379 RMS ERROR = 0.0273