ML092330041
| ML092330041 | |
| Person / Time | |
|---|---|
| Site: | Oconee, 07201004 |
| Issue date: | 08/18/2009 |
| From: | Baxter D Duke Energy Carolinas |
| To: | Document Control Desk, NRC/NMSS/SFPO |
| References | |
| Download: ML092330041 (2) | |
Text
Duke DAVE BAXTER Duke Vice President Energy Oconee Nuclear Station Duke Energy ON01 VP / 7800 Rochester Highway Seneca, SC 29672 864-873-4460 864-873-4208 fax dabaxter@dukeenergy. corn August 18, 2009 ATTN: Document Control Desk, Director, Spent Fuel Project Office, Office of Nuclear Material Safety and Safeguards, U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001
Subject:
Duke Energy Carolinas, LLC Oconee Nuclear Site, Units 1, 2, and 3 Renewed Operating Licenses: DPR-38, 47, and 55 Docket Numbers: 50-269, 270, and 287 Registration for Use of General License Spent Fuel Cask Number 109 In accordance with 10CFR72.212(b)(1)(ii), Duke Energy Carolinas, LLC (Duke), hereby notifies the Commission of storage of dry fuel under Cask Certificate of Compliance 72-1004, Amendment 9. The date of storage was August 9, 2009; the Cask Load Number was 109. The cask model is the Standardized NUHOMS 24PHB, the dry storage canister (DSC) identification number is ONS-24PHBL-HZ109; the physical location at the Oconee ISFSI was Module W-43.
If there are any questions regarding this registration, please contact Stephen C. Newman, Oconee Regulatory Compliance Lead Engineer, at (864) 873-4388.
Sincerely, Dave axter Vice President, Oconee Nuclear Station www. duke-energy, com
U. S. Nuclear Regulatory Commission August 18, 2009 Page 2 cc:
Mr. Michael F. Weber, Director Office of Nuclear Material Safety and Safeguards Mailstop: EBB I U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Mr. John M. Goshen, Project Manager Division of Spent Fuel Storage and Transportation Office of Nuclear Material Safety and Safeguards Mailstop: E3 D2M U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Mr. John Stang, Project Manager Office of Nuclear Reactor Regulation Mail Stop 0-14 H25 U.S. Nuclear Regulatory Commission Washington, D. C., 20555-0001 Mr. Scott Atwater Senior Fuel Facility Inspector USNRC, Region II Sam Nunn Atlanta Federal Center, Suite 23T85, 61 Forsyth St., SW, Atlanta, GA 30303-8931 Mr. Luis Reyes USNRC - Region II Sam Nunn Atlanta Federal Center, Suite 23T85, 61 Forsyth St., SW, Atlanta, GA 30303-8931 Mr. Eric Riggs NRC Senior Resident Inspector (Acting)
Oconee Nuclear Station