ML092180026

From kanterella
Jump to navigation Jump to search
2008 Byron Station Initial License Examination ES-301-1 and ES-301-2 Forms
ML092180026
Person / Time
Site: Byron  
Issue date: 05/19/2008
From:
Operations Branch III
To:
Exelon Generation Co
References
ES-301-1, ES-301-2
Download: ML092180026 (6)


Text

ES-301 Administrative Topics Outline Form ES-301-1 Facility: Byron 2008 Exam Date of Examination: 5/19/08 Examination Level: RO SRO Operating Test Number: _2008301__

Administrative Topic (see Note)

Type Code*

Describe activity to be performed Conduct of Operations -

Manually Calculate SG Pri-Sec Tube Leakage N, S or R Ability to recognize indications for system operating parameters which are entry-level conditions for technical specifications. K/A 2.1.33 Imp Factor 3.4 Equipment Control -

Write a Clearance Order for approval N

Knowledge of Tagging and Clearance Procedures.

K/A 2.2.13 Imp Factor 3.6 Radiation Control -

Respond to GDT High Activity D

Ability to perform procedures to reduce excessive levels of radiation and guard against personnel exposure.

K/A 2.3.10 Imp Factor 2.9 Emergency Procedures/Plan Respond to Turbine Bldg Fire N

Knowledge of Fire Protection Procedures.

K/A 2.4.25 Imp Factor 3.3 NOTE: All items (5 total) are required for SROs. RO applicants require only 4 items unless they are retaking only the administrative topics, when all 5 are required.

  • Type Codes & Criteria:

(C)ontrol room, (S)imulator, or Class(R)oom (D)irect from bank ( 3 for ROs; 4 for SROs & RO retakes)

(N)ew or (M)odified from bank ( 1)

(P)revious 2 exams ( 1; randomly selected)

ES-301 Control Room/In-Plant Systems Outline Form ES-301-2 Facility: Byron Station Date of Examination: 5/19/08 Exam Level: RO SRO-I SRO-U Operating Test No.: _2008301______

Control Room Systems@ (8 for RO); (7 for SRO-I); (2 or 3 for SRO-U, including 1 ESF)

System / JPM Title Type Code*

Safety Function

a. Respond to an ATWS situation K/A 013 A4.01 Imp Factor 4.5/4.8 D, EN, A 1
b. Initiate a 60 PPM Dilution K/A 004A4.07 Imp Factor 3.9/3.7 D, S 2
c. Respond to a Pzr Press Control Malf K/A 010A4.01 Imp Factor 3.7/3.5 D, S 3
d. Respond High RCP Seal Leakoff Flow K/A 003 A2.01 Imp Factor 3.5/3.9 P, M, A, S 4
e. Start the 1B Cnmt Chiller Remotely K/A 022A4.02 Imp Factor 3.2/3.1 N, S, L 5
f. Start and Load the 1A D/G K/A 064A2.09 Imp Factor 3.1/3.3 D, A, S 6
g. Start Post Loca Cnmt H2 Monitoring Sys.K/A029A2.04 Imp Factor 2.5/3.2 N, S, EN 8
h. Release Unit 1 Cnmt K/A 071A4.26 Imp Factor 3.1/3.9 N, A, S 9

In-Plant Systems@ (3 for RO); (3 for SRO-I); (3 or 2 for SRO-U)

i. Start CC Hx Outlet Rad Monitor 2PR09J K/A 073 G2.1.30 Imp Factor 3.9/3.4 D

7

j. Parallel DC Busses (one bus de-energized) K/A 058AA1.01 Imp Factor 3.4/3.5 D, E 5
k. Emergency Start 2B AF pump K/A 061A2.04 Imp Factor 3.4/3.8 D, A, R, E 4

All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all 5 SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.

  • Type Codes Criteria for RO / SRO-I / SRO-U (A)lternate path (C)ontrol room (D)irect from bank (E)mergency or abnormal in-plant (EN)gineered safety featu (L)ow-Power / Shutdown re (N)ew or (M)odified (P)revious 2 exams from bank including 1(A)

(R)CA (S)imulator 4-6 / 4-6 / 2-3 9 / 8 / 4 1 / 1 / 1

- / - / 1 (

1 / 1 / 1 control room system) 2 / 2 / 1 3 / 3 / 2 (randomly selected) 1 / 1 / 1

ES-301 Administrative Topics Outline Form ES-301-1 Facility: ___Byron 2008 Exam______________

Date of Examination:

5/19/08__

Examination Level: RO SRO Operating Test Number: _2008301__

Administrative Topic Co e*

Describe activity to be performed (see Note)

Type d

Conduct of Operations -

Initiate 1BOL 9.3 for failed N

Ability to apply te or a system. KA source range detector chnical specifications f 2.1.12 Imp Factor 4.0 (CFR 43.2 / 43.5 / 45.3)

Conduct of Operations -

Review Manual Calculation of SG Pri-Sec Tube Leakage N, S or R A

g technical spe Factor 3.5 bility to recognize indications for system operatin parameters which are entry-level conditions for cifications. K/A 2.1.33 Imp (CFR: 43.2 / 43.3 / 45.3)

Equipment Control -

Review a Clearance Order for N

Knowledge rocedures.

K

.8 (CFR: 41.10 / 45.13) approval of Tagging and Clearance P

/A 2.2.13 Imp Factor 3 Radiation Control -

Review a Liquid Release Package for release approval N

approving relea Imp Factor 3.1 (CFR: 43.4 / 45.10)

Knowledge of the requirements for reviewing and se permits. KA 2.3.6 Emergency Procedures/Plan -

re a PBI permit N

Knowledge of fire prot dures. KA 2.4.25 Imp (CFR: 41.10 / 45.13)

Prepa ection proce Factor 3.4 NOTE:

only 4 items unless they are retaking only the administrative topics, when all 5 are required.

All items (5 total) are required for SROs. RO applicants require

  • Type Codes & Criteria:

or SROs & RO retakes)

(P)revious 2 exams ( 1; randomly selected)

(C)ontrol room, (S)imulator, or Class(R)oom (D)irect from bank ( 3 for ROs; 4 f (N)ew or (M)odified from bank ( 1)

ES-301 Control Room/In-Plant Systems Outline Form ES-301-2 Facility: Byron Station Date of Examination: 5/19/08 Exam Level: RO SRO-I SRO-U Operating Test No.: _2008301______

Control Room Systems@ (8 for RO); (7 for SRO-I); (2 or 3 for SRO-U, including 1 ESF)

System / JPM Title Type Code*

Safety Function

a. Respond to an ATWS situation K/A 013 A4.01 Imp Factor 4.5/4.8 D, EN, A 1
b. Initiate a 60 PPM Dilution K/A 004A4.07 Imp Factor 3.9/3.7 D, S 2
c.
d. Respond High RCP Seal Leakoff Flow K/A 003 A2.01 Imp Factor 3.5/3.9 P, M, A, S 4
e. Start the 1B Cnmt Chiller Remotely K/A 022A4.02 Imp Factor 3.2/3.1 N, S, L 5
f. Start and Load the 1A D/G K/A 064A2.09 Imp Factor 3.1/3.3 D, A, S 6
g. Start Post Loca Cnmt H2 Monitoring Sys.K/A029A2.04 Imp Factor 2.5/3.2 N, S, EN 8
h. Release Unit 1 Cnmt K/A 071A4.26 Imp Factor 3.1/3.9 N, A, S 9

In-Plant Systems@ (3 for RO); (3 for SRO-I); (3 or 2 for SRO-U)

i. Start CC Hx Outlet Rad Monitor 2PR09J K/A 073 G2.1.30 Imp Factor 3.9/3.4 D

7

j. Parallel DC Busses (one bus de-energized) K/A 058AA1.01 Imp Factor 3.4/3.5 D, E 5
k. Emergency Start 2B AF pump K/A 061A2.04 Imp Factor 3.4/3.8 D, A, R, E 4

All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all 5 SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.

  • Type Codes Criteria for RO / SRO-I / SRO-U (A)lternate path (C)ontrol room (D)irect from bank (E)mergency or abnormal in-plant (EN)gineered safety feature (L)ow-Power / Shutdown (N)ew or (M)odified from bank including 1(A)

(P)revious 2 exams (R)CA (S)imulator 4-6 / 4-6 / 2-3 9 / 8 / 4 1 / 1 / 1

- / - / 1 (control room system) 1 / 1 / 1 2 / 2 / 1 3 / 3 / 2 (randomly selected) 1 / 1 / 1 ES-301 Administrative Topics Outline Form ES-301-1

Facility: ___Byron 2008 Exam_________________

Date of Examination: 5/19/08__

Examination Level: RO SRO Operating Test Number: __2008301_

Administrative Topic (see Note)

Type Code*

Describe activity to be performed Conduct of Operations -

Initiate 1BOL 9.3 for failed source range detector N

Ability to apply technical specifications for a system. KA 2.1.12 Imp Factor 4.0 (CFR 43.2 / 43.5 / 45.3)

Conduct of Operations -

Review Manual Calculation of SG Pri-Sec Tube Leakage N, S or R Ability to recognize indications for system operating parameters which are entry-level conditions for technical specifications. K/A 2.1.33 Imp Factor 3.5 (CFR: 43.2 / 43.3 / 45.3)

Equipment Control -

Review a Clearance Order for approval N

Knowledge of Tagging and Clearance Procedures.

K/A 2.2.13 Imp Factor 3.8 (CFR: 41.10 / 45.13)

Radiation Control -

Review a Liquid Release Package for release approval N

Knowledge of the requirements for reviewing and approving release permits. KA 2.3.6 Imp Factor 3.1 (CFR: 43.4 / 45.10)

Emergency Procedures/Plan -

Prepare a PBI permit N

Knowledge of fire protection procedures. KA 2.4.25 Imp Factor 3.4 (CFR: 41.10 / 45.13)

NOTE: All items (5 total) are required for SROs. RO applicants require only 4 items unless they are retaking only the administrative topics, when all 5 are required.

  • Type Codes & Criteria:

(C)ontrol room, (S)imulator, or Class(R)oom (D)irect from bank ( 3 for ROs; 4 for SROs & RO retakes)

(N)ew or (M)odified from bank ( 1)

(P)revious 2 exams ( 1; randomly selected)

ES-301 Control Room/In-Plant Systems Outline Form ES-301-2 Facility: Byron Station Date of Examination: 5/19/08 Exam Level: RO SRO-I SRO-U Operating Test No.: _2008301_____

Control Room Systems@ (8 for RO); (7 for SRO-I); (2 or 3 for SRO-U, including 1 ESF)

System / JPM Title Type Code*

Safety Function

a.
b. Initiate a 60 PPM Dilution K/A 004A4.07 Imp Factor 3.9/3.7 D, S 2
c.
d. Respond High RCP Seal Leakoff Flow K/A 003 A2.01 Imp Factor 3.5/3.9 P, M, A, S 4
e.
f.
g. Start Post Loca Cnmt H2 Monitoring Sys.K/A029A2.04 Imp Factor 2.5/3.2 N, S, EN 8
h.

In-Plant Systems@ (3 for RO); (3 for SRO-I); (3 or 2 for SRO-U)

i.
j. Parallel DC Busses (one bus de-energized) K/A 058AA1.01 Imp Factor 3.4/3.5 D, E 5
k. Emergency Start 2B AF pump K/A 061A2.04 Imp Factor 3.4/3.8 D, A, R, E 4

All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all 5 SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.

  • Type Codes Criteria for RO / SRO-I / SRO-U (A)lternate path (C)ontrol room (D)irect from bank (E)mergency or abnormal in-plant (EN)gineered safety feature (L)ow-Power / Shutdown (N)ew or (M)odified from bank including 1(A)

(P)revious 2 exams (R)CA (S)imulator 4-6 / 4-6 / 2-3 9 / 8 / 4 1 / 1 / 1

- / - / 1 (control room system) 1 / 1 / 1 2 / 2 / 1 3 / 3 / 2 (randomly selected) 1 / 1 / 1