John Richmond From:

David Pelton,

Sent:

Thursday, November 06, 2008 8:17 AM To:

John Richmond; Marsha Gamberoni; Darrell Roberts; Ronald Bellamy; Richard Conte; Mary Baty; James Davis; John White Cc:

Stephen Pindale; Justin Heinly; Jeffrey Kulp; Timothy OHara; Michael Modes; Glenn Meyer; Paul Kaufman; Heather Jones; Brian Holian

Subject:

RE: Oyster Creek Drywell Shell Coating Issue

John, I need help understanding the "inverted cone" and "small pit." Do you have a rough dimension (diameter, depth, etc.)? Does it appear to be a tool mark? Thoughts?

David Pelton NRC/NRR/DLR Chief, Projects Branch I (301) 415-2307 From: John Richmond Sent: Wednesday, November 05, 2008 9:02 PM To: Marsha Gamberoni; Darrell Roberts; Ronald Bellamy; Richard Conte; David Pelton; Mary Baty; James Davis; John White Cc: Stephen Pindale; Justin Heinly; Jeffrey Kulp; Timothy OHara; Michael Modes; Glenn Meyer; Paul Kaufman; Heather Jones

Subject:

Oyster Creek Drywell Shell Coating Issue Oyster Creek Drywell Sand Bed Bay 11 Coating Defects Nov 5 AmerGen initiated their repair plan this evening. The one loose blister previously identified by AmerGen was excavated, along with 3 other adjacent bumps identified by NRC inspection. Surface rust, on the drywell shell, was easily recognizable under all 4 locations. The 4 locations are within a 1 to 2 inch oval of each other. The 3 bumps, which AmerGen initially characterized as surface irregularities, were tightly adhered, and were difficult to "pop off" (e.g., the technician said it took a lot of force to dislodge them). The blister was easily removed intact. The exposed drywell shell (4 locations) was lightly sanded, generally resulting in a clean brighi metal surface. Under 2 of the locations, the exposed surface had an inverted cone shape, with the point of the cone going into the plate steel. There appeared to be a small pit at the center of the cones.

The original rust stain, about 6 inches long, was scrapped off, and the scrapings collected into a bag for lab analysis. The broken blister, originally described as a carbuncle, was collected mostly intact, also for lab analysis.

AmerGen's coating expert, Jon Cavallo, Corrosion Control Consultants & Labs, described the three layer coating as follows: (1) a clear primer, (2) a reddish brown epoxy layer, applied by roller, and (3) a grayish white epoxy layer applied by roller. Jon believes that the 2 epoxy layers should be 6 to 10 mils each, and that the three layer coating system would therefore be 12 to 18 mils in thickness. As a comparison, Jon said that a normal piece of copy paper is about 3 mils thick, so he expected the total coating thickness to be equivalent to about 3 sheets of paper. Jon believes the lab analysis will adequately determine the coating thickness of the collected scrapings and samples.

hoIialf In this reco=d was deltedIn armOrdnDe with the Freedom of Informatlon AO FOIoru 2-Aa ?-64-7f)

John Richmond From: John Richmond Sent: Monday, November 03, 2008 7:51 PM To: Marsha Gamberoni; Darrell Roberts; Ronald Bellamy; Richard Conte; David Pelton; Mary Baty; James Davis; John White Cc: Stephen Pindale; Justin Heinly; Jeffrey Kulp; Timothy OHara; Michael Modes; Glenn Meyer; Paul Kaufman

Subject:

RE: Oyster Creek Drywell Shell Coating Issue Summary of Conference Call between Exelon and NRC staff, regarding OC Drywell Sand Bed Bay-1 1 repair plans.

During an interactive discussion (questions and answers), Exelon Stated:

1) Detailed plan is still being developed, which will include:
a. Opportunities for NRC observations during excavation and examination of the defect
b. Chemical analysis to attempt to determine whether the surface stain contains iron
c. Will carefully remove top loose layers to help determine whether there is any on-going drywell shell corrosion
d. Will excavate an area maybe an inch in diameter, which should include any very close surface irregularities
2) No additional extent-of-condition was needed, to determine whether there are any blisters (carbuncles) in any other areas or other sand bed bays. A 100% coating examination had already been performed and no other defect or indication had been identified.
3) There is only one blister (about 1/4 inch in diameter), as documented on the VT-1 Examination Record.

There are no other blisters or carbuncles, as suggested by the NRC inspection of Nov 2. The inspector's observations must have been "bumps" that are just surface irregularities.

(b)(5)

6) An ultrasonic test (UT) will be performed (maybe tonight), from the inside of the drywell, at the location of the coating defect.

If I left anything out, please feel free to add it in.

John Richmond From: John Richmond Sent: Sunday, November 02, 2008 6:41 PM To: Marsha Gamberoni; Darrell Roberts; James Clifford; Ronald Bellamy; Richard Conte; Marc Dapas; John White Cc: David Pelton; Stephen Pindale; Justin Heinly; Jeffrey Kulp; Timothy OHara; Michael Modes; Glenn Meyer; Paul Kaufman

Subject:

Oyster Creek Drywell Shell Coating Issue OC License Renewal Outage Commitments Inspection Drywell Shell (steel liner) Coating Issue 2

Exterior Drywell Shell in Sand Bed Bay 11 On Oct 31, during a routine coating inspection, AmerGen identified a coating defect. NDE VT Examination Record documented a "Pinhole Carbuncle, 1/4 inch in diameter, with Evidence of Leakage (Rust Line) 6 inches Long. 16 inches right of Opening [access tunnel], 34 inches from Moisture Barrier [floor in sand bed cavity]."

The carbuncle was verbally described as a small blister, soft to the touch. The leakage was verbally described as a "bleed through" 6" long teardrop shaped surface stain, brownish in color, and dry to the touch.

A repair work order is being prepared. Repairs are scheduled for Nov 4. Per engineering specification, the coating defect will be removed using mechanical tools, such as pencil grinder, rotary file, flapper wheel, etc

[e.g., skill of the craft]. Prepare the substrate and feather the edges, then apply two layers of new coating

[Devoe epoxy]. The Issue Report contains additional requirements, not yet in the work order, including (1) document the extent of the damage, and how deep the blister has formed into the coating, (2) verify plate thickness in the area of the coating failure meets acceptance criteria [e.g., do a UT from inside the drywell],

and (3) document with pictures as loose coating layers are removed.

The carbuncle, on the exterior surface of drywell shell, is very close to ultrasonic test (UT) location 11 A, inside the drywell at elevation 11 ft. 3 in. UT location 1 1A is a 7x7 array (6"x6" grid). The carbuncle is located about 3 inches from a core plug that is in the 7x7 array. AmerGen estimates that the carbuncle is about 1 inch from the edge of the array. Therefore, it's reasonable to expect that a good UT can be done from inside the drywell at the location of the defect outside the drywell.

Sand Bed Bays 1, 11, and 13 were previously identified as the bays with the most significant corrosion (e.g.,

thinnest shell). The epoxy coating system was applied in 1992, and was 3 layers thick. The total thickness is believed to be about 25 mils. The first post-installation coating inspection was last outage, in 2006. This is only the second coatings inspection since 1992. In 2006, no coating defects were identified. This outage (2008), only this one coating defect was identified.

All sand bed bays have been NDE UT and VT examined this outage (not all NDE examination records have been prepared). No other potential coating defects were identified. Some cracks in the floor epoxy sealer and in the moisture barrier seal were identified, and are planned to be reworked.

(b)(5)

John Richmond OC NRC Team Room 609-971-4830 3

.5 Received: from TWMS01.nrc.gov(148.184.200.145) by R1MSO1.nrc.gov (148.184.99.10) with Microsoft SMTP Server (TLS) id 8.1.291.1; Thu, 6 Nov 2008 08:17:27 -0500 Received: from HQCLSTR02.nrc.gov ([148.184.44.77]) by TWMSO1.nrc.gov

([148.184.200.145]) with mapi; Thu, 6 Nov 2008 08:17:26 -0500 Content-Type: application/ms-tnef; name="winmail.dat" Content-Transfer-Encoding: binary From: David Pelton <David.Pelton@nrc.gov>

To: John Richmond <John.Richmond@nrc.gov>, Marsha Gamberoni

<Marsha.Gamberoni@nrc.gov>, Darrell Roberts <Darrell.Roberts@nrc.gov>, Ronald Bellamy <Ronald.Bellamy@nrc.gov>, Richard Conte <Richard.Conte@nrc.gov>, Mary Baty <Mary.Baty@nrc.gov>, James Davis <James.Davis@nrc.gov>, John White

<John.White@nrc.gov>

CC: Stephen Pindale <Stephen.Pindale@nrc.gov>, Justin Heinly

<Justin. Heinly@nrc.gov>, Jeffrey Kulp <Jeffrey. Kulp@nrc.gov>, Timothy OHara

<Timothy.OHara@nrc.gov>, Michael Modes <Michael. Modes@nrc.gov>, Glenn Meyer

<Glenn.Meyer@nrc.gov>, Paul Kaufman <Paul.Kaufman@nrc.gov>, Heather Jones

<Heather.Jones@nrc.gov>, Brian Holian <Brian.Holian@nrc.gov>

Date: Thu, 6 Nov 2008 08:17:25 -0500

Subject:

RE: Oyster Creek Drywell Shell Coating Issue Thread-Topic: Oyster Creek Drywell Shell Coating Issue Thread-Index:

Ack8Y7mvDm CrhVEUTRWMXhVNCmYTvwAxulcQAAUh2ZAAAPCYOAAAA1 7wADQEP8AAZ wVNIAAYg8pQ Message-ID:

<DC2088DF7F51 A8499309AA4A35D0C 1 EO 1 40F82960E@HQCLSTRO2. nrc.gov>

References:

<2856BC46F6A308418F033D973BBOEE72AA436328BC@R1CLSTR01.nrc.gov>

<2856BC46F6A308418F033D973BBOEE72AA436328C5@R1 CLSTR01.n rc.gov>

<2856BC46F6A308418 F033D973BBOEE72AA436328C6@R1 CLSTRO1.n rc.gov>

<2856BC46F6A308418F033D973BBOEE72AA436328C8@R1 CLSTRO1.n rc.gov>

<2856BC46F6A308418F033D973BBOEE72AA436328C9@R1 CLSTRO1.nrc.gov>

<2856 BC46F6A308418F033D973BBOEE72AA436328D9@R1 CLSTRO1.nrc.gov>

<2856BC46 F6A308418F033D973BBOE E72AA436328E2@R1 CLSTR01. nrc.gov>

In-Reply-To: <2856BC46F6A308418F033D973BBOEE72AA436328E2@R1CLSTRO1.nrc.gov>

Accept-Language: en-US Content-Language: en-US X-MS-Has-Attach:

X-MS-Exchange-Organization-SCL: -1 X-MS-TNEF-Correlator:

<DC2088DF7F51A8499309AA4A35D0C1 E0140F82960E@HQCLSTRO2.nrc.gov>

MIME-Version: 1.0 Return-Path: David.Pelton@nrc.gov