ML091900440

From kanterella
Jump to navigation Jump to search
E-mail from J. Richmond of USNRC to Various, Regarding Oyster Creek Lri Update Nov. 20
ML091900440
Person / Time
Site: Oyster Creek
Issue date: 11/22/2008
From: Richmond J
NRC Region 1
To: Baty M, Ronald Bellamy, Conte R, David Pelton, Darrell Roberts
NRC Region 1
References
FOIA/PA-2009-0070
Download: ML091900440 (3)


Text

Sarah Rich From:

John Richmond - RZ Sent:

Saturday, November 22, 2008 11:57 AM To:

Darrell Roberts; Richard Conte; David Pelton; Ronald Bellamy; Mary Baty Cc:

Doug Tifft; Stephen Pindale; Jeffrey Kulp; Justin Heinly; Diane Screnci; Neil Sheehan; Marjorie McLaughlin; Nancy McNamara; Lisa Regner

Subject:

OC LRI Update Nov 20 Thursday afternoon AmerGen provided us an update on the two issues below. It was a good exchange of information and viewpoints. NJ DEP (Ron Zak & Pat Mulligan) listened and had an opportunity to ask questions of AmerGen at the end. The conference call lasted about 30 minutes.

AmerGen's perspective was that they adequately implemented the two commitments in question because their actions "met the intend" of the commitments.

(b)(5)

Please remember out time table, to reach a consensus, is very short.

Thanks for the continued support John R.

ps: Have a Great Thanksgiving Day!!!

From: John Richmond Sent: Thursday, November 20, 2008 12:21 PM To: Calvin.TaYlor@exeloncorp.com; jhansi.kandasamy@exeloncorp.com; Darrell Roberts; Stephen Pindale; Doug Tifft; David Pelton; Lisa Regner; Mary Baty Cc: ron.zak@dep.state.nj.us; richard.pinney@dep.state.nj.us; Richard Conte; Ronald Bellamy; Jeffrey Kulp; Justin Heinly; Diane Screnci; Neil Sheehan; Nancy McNamara; Marjorie McLaughlin

Subject:

RE: OC Update Call on Strippable Coating & sand Bed Drain Commitments AmerGen's update will discuss their basis that the commitments were adequately implemented Telecom Update Date Today (11/20)

Time 3:00 PM Bridge 888-94_6-6308

(',

Passcode E5l)(2)High Duration 1/2 hO 8 bridge lines are available I

111111IN11111111W In Ot -oredwas dsetdk In WwIdfflo with the Freedom-of 1nfo6011o Act

R-M-M-A P 7-4c The 2 commitments in question (1) SER Commitment 27, ASME Section Xl, Subsection IWE. Item (2), A strippable coating will be applied to the reactor cavity liner to prevent water intrusion into the gap between the drywell shield wall and the drywell shell during periods when the reactor cavity is flooded.

AmerGen was asked to provide the following information

> Performance of the strippable coating during the two previous outages (2006 & 2004)

> Any condition reports (CRs), issue reports (IRs), or action requests (ARs) associated with the strippable coating from the 2006 outage (2) SER Commitment 27, ASME Section Xl, Subsection IWE. Item (3), The sand bed region drairns wild be monitored daily during refueling outages.

AmerGen was asked to provide their basis to conclude this commitment had been adequately satisfied, in light of the following

> Sand bed drains were monitored by checking poly bottles, attached to the drain lines by tygon tubing. The drain lines could not be directly observed.

> After the cavity was drained, 2 of 5 tygon tubes were found to be disconnected and laying on the floor.

> Sand bed Bay 11 drain line poly bottle was empty during each daily check until Nov 15 (cavity was drained on Nov 12), when it was found full (> 4 gallons). Bay 11 was entered, visually inspected, and found dry. AmerGen believes that the 4+ gallons had been held up in the catch funnel (not directly observable). This implies that the Bay 11 drain line had not be draining into the poly bottle for some period of time.

2

Received: from R1CLSTRO1.nrc.gov ([148.184.99.7]) by R1 MSO1.nrc.gov

([148.184.99.10]) with mapi; Sat, 22 Nov 2008 11:57:14-0500 Content-Type: application/ms-tnef; name="winmail.dat" Content-Transfer-Encoding: binary From: John Richmond <John.Richmond@nrc.gov>

To: Darrell Roberts <Darrell.Roberts@nrc.gov>, Richard Conte

<Richard.Conte@nrc.gov>, David Pelton <David.Pelton@nrc.gov>, Ronald Bellamy

<Ronald.Bellamy@nrc.gov>, Mary Baty <Mary.Baty@nrc.gov>

CC: Doug Tifft <Doug.Tifft@nrc.gov>, Stephen Pindale

<Stephen. Pindale@nrc.gov>, Jeffrey Kulp <Jeffrey. Kulp@nrc.gov>, Justin Heinly

<Justin. Heinly@nrc.gov>, Diane Screnci <Diane.Screnci@nrc.gov>, Neil Sheehan

<NeiI.Sheehan@nrc.gov>, Marjorie McLaughlin

<Marjorie.McLaughlin@nrc.gov>,

Nancy McNamara <Nancy.McNamara@nrc.gov>, Lisa Regner

<Lisa. Regner@nrc.gov>

Date: Sat, 22 Nov 2008 11:57:13 -0500

Subject:

OC LRI Update Nov 20 Thread-Topic: OC LRI Update Nov 20 Thread-Index: AclLLH9v7eCuowRpRAOe/ZIBGE8RrgABvzAQAGJWnxA=

Message-ID:

<2856BC46F6A308418F033D973BBOEE72AA545E3A25@R1 CLSTRO1.nrc.gov>

References:

<2856BC46F6A308418F033D973BBOEE72AA54A365E9@R1 CLSTRO1.nrc.gov>

<2856BC46F6A308418F033D973BBOEE72AA54A3663E@R1 CLSTRO1.nrc.gov>

In-Reply-To:

<2856BC46F6A308418F033D973BB0EE72AA54A3663E@R1 CLSTRO0.nrc.gov>

Accept-Language: en-US Content-Language: en-US X-MS-Has-Attach:

X-MS-Exchange-Organization-SCL: -1 X-MS-TNEF-Correlator:

<2856BC46F6A308418F033D973BBOEE72AA545E3A25@RICLSTRO1.nrc.gov>

MIME-Version: 1.0