MONTHYEARML22235A7862022-08-23023 August 2022 Acceptance Review: Exemption Request from 10 CFR 20, Appendix G, LLW Shipping Investigation Requirements ML21181A1882021-06-30030 June 2021 E-mail from S. Johnston, Holtec, to A. Snyder and F. Bower, NRC - Oyster Creek Nuclear Generating Station - Readiness Status for ISFSI Only Inspection ML21175A2092021-06-24024 June 2021 E-mail from A. Sterdis to P. Longmire - Oyster Creek Nuclear Generating Station: ISFSI-only Physical Security Plan (Stating Implementation Intent) ML21162A3602021-06-11011 June 2021 E-mail Response from the State of New Jersey Regarding the Pending Revision to the Emergency Plan to Reflect Independent Spent Fuel Storage Installation Only Status ML21162A1172021-06-11011 June 2021 E-mail to HDI: Acceptance Review - FOF Exemption ML21168A0172021-06-10010 June 2021 E-mail from HDI: RAI Response ML21161A2572021-06-0707 June 2021 State Consultation: ISFSI-only Physical Security Plan (Email Response) ML21175A0712021-06-0202 June 2021 Issuance of Request for Additional Information: Oyster Creek Nuclear Generating Station. Request for Amendment to Technical Specifications ML21148A0562021-05-27027 May 2021 E-mail to State of New Jersey Informing of the Pending Revision to the Emergency Plan to Reflect Independent Spent Fuel Storage Installation Only Status ML21132A3182021-05-12012 May 2021 E-Mail from V. Gubbi, DEP to Z. Cruz, NRC - Oyster Creek Nuclear Generating Station - State of New Jersey Response to the Pending Revision to the Defueled Technical Specifications to Reflect Independent Spent Fuel Storage Installation Only ML21132A0312021-05-11011 May 2021 E-mail to State of New Jersey Informing of the Pending Revision to the Physical Security Plan to Reflect Independent Spent Fuel Storage Installation Only Status ML21119A1422021-04-28028 April 2021 E-mail to State of New Jersey Informing of the Pending Revision to the Emergency Plan to Reflect Independent Spent Fuel Storage Installation Only Status ML21113A0742021-04-23023 April 2021 Acceptance Review Email - April 20, 2021 Oyster Creek Request for Exemption from 10 CFR Part 73 Requirements Due to Covid ML21099A0382021-04-0808 April 2021 Email from Z. Cruz to A. Sterdis - Request for Additional Information - HDI Request for Approval of Oyster Creek Nuclear Generating Station Independent Spent Fuel Storage Installation Facility Only Emergency Plan ML21085A4872021-03-26026 March 2021 E-mail from Z. Cruz to A. Sterdis - Acceptance Review: Oyster Creek Nuclear Generating Station - Request for Approval of Independent Spent Fuel Storage Installation Only Permanently Defueled Technical Specifications ML21064A2432021-03-0505 March 2021 Email from Z. Cruz to A. Sterdis Acceptance Review_ Oyster Creek Nuclear Generating Station - Request for Approval of Independent Spent Fuel Storage Installation Facility Only Emergency Plan and Emergency Action Level Scheme ML21064A2392021-03-0202 March 2021 E-mail from Z. Cruz to A. Sterdis Acceptance Review - Oyster Creek Nuclear Generating Station - Request for Approval of Independent Spent Fuel Storage Installation Only Physical Security Plan ML20345A1462020-12-0909 December 2020 E-mail - Response to Request for Additional Information: HDI Request for One-Time Exemption from Part 73, Appendix B FOF Requirements ML20335A3112020-11-30030 November 2020 Request for Additional Information Regarding Request for a one-time Exemption from Part 73, Appendix B Requirements for Oyster Creek Nuclear Generating Station ML20332A1472020-11-24024 November 2020 Acceptance Review: November 20 2020 Exemption Request from 10 CFR Part 73 Appendix B Requirements for Oyster Creek ML20297A2372020-10-22022 October 2020 Request for Additional Information - HDI Fleet Decommissioning Quality Assurance Program ML20279A5082020-10-0505 October 2020 Email to Holtec - Response to Notification of Oyster Creek Onsite Property Insurance Coverage ML20266G4032020-09-22022 September 2020 Acceptance Review Email - Request for Approval of HDI Fleet Decommissioning Quality Assurance Program, Revision 0 ML20134H8742020-05-12012 May 2020 Request for Additional Information Regarding Request for Temporary Exemption from Part 73, Appendix B Requirements ML20133J9182020-05-11011 May 2020 Acceptance Review Email - Oyster Creek Request for Exemption from Part 73 Qualification Requirements ML20120A0252020-04-22022 April 2020 NRR E-mail Capture - (External_Sender) Oyster Creek Sea Turtle Handling and Conservation Recommendation Obligations NRC-2019-0073, Response from NEIMA Local Community Advisory Board Questionnaire 10-30-2019 R Discenza2019-10-30030 October 2019 Response from NEIMA Local Community Advisory Board Questionnaire 10-30-2019 R Discenza ML19344C8022019-10-20020 October 2019 Response from NEIMA Local Community Advisory Board Questionnaire 10-20-2019 a Dressler ML19344C8002019-10-0909 October 2019 Response from NEIMA Local Community Advisory Board Questionnaire 10-09-2019 W Mcmullin ML19344C7982019-10-0909 October 2019 Response from NEIMA Local Community Advisory Board Questionnaire 10-09-2019 M Noto ML19344C7992019-10-0909 October 2019 Response from NEIMA Local Community Advisory Board Questionnaire 10-09-2019 s Feldman ML19344C7932019-10-0909 October 2019 Response from NEIMA Local Community Advisory Board Questionnaire 10-09-2019 C Bischoff ML19344C7962019-10-0909 October 2019 Response from NEIMA Local Community Advisory Board Questionnaire 10-09-2019 G Adams ML19344C7912019-10-0808 October 2019 Response from NEIMA Local Community Advisory Board Questionnaire 10-08-2019 J Branciforte ML19344C7902019-10-0808 October 2019 Response from NEIMA Local Community Advisory Board Questionnaire 10-08-2019 Anonymous ML19344C7892019-10-0505 October 2019 Response from NEIMA Local Community Advisory Board Questionnaire 10-05-2019 P Dressler ML19263D1222019-09-20020 September 2019 for Your Action Request for Additional Information Hdi Oyster Creek PSDAR ML19214A0452019-08-0202 August 2019 NRC to NMFS, Revised Proposed Action for Oyster Creek Endangered Species Act Section 7 Consultation ML19182A3422019-07-0101 July 2019 Transaction ML19178A0702019-06-26026 June 2019 Email to State of New Jersey - Oyster Creek - Request Comments on Proposed Amendment to Remove Reference to the Oyster Creek Cyber Security Plan and Update License Condition 2.C.(4) in the Renewed Facility License ML19196A3422019-06-20020 June 2019 Email: Courtesy Notice on the Issuance of the Oyster Creek License Transfer and Exemption (Sierra Club) ML19196A3342019-06-20020 June 2019 Email: Courtesy Notice on the Issuance of the Oyster Creek License Transfer and Exemption ML19162A2242019-06-11011 June 2019 NRC to NMFS, NRC Responses to NMFS Requests for Additional Information for Oyster Creek ESA Section 7 Consultation NRC-2018-0237, Comment from Paul Dressler of the Concerned Citizens for Lacey Coalition, Regarding the Oyster Creek Nuclear Plant License Transfer Application2019-06-0707 June 2019 Comment from Paul Dressler of the Concerned Citizens for Lacey Coalition, Regarding the Oyster Creek Nuclear Plant License Transfer Application ML19155A1182019-06-0404 June 2019 Incoming E-mail from State of New Jersey on the Oyster Creek Exemption for Reduced Insurances and Use of Decommissioning Trust Fund for Spent Fuel Management and Site Restoration ML19155A1192019-06-0404 June 2019 State of New Jersey Comments - Oyster Creek Conforming Amendment Associated with the Oyster Creek Generating Station License Transfer Application ML19154A0582019-05-31031 May 2019 E-mail Response from State of New Jersey Dated May 31, 2019, Notification-and-Request-Oyster Creek License Transfer Application L-2018-LLM-0002 ML19158A2912019-05-30030 May 2019 NRR E-mail Capture - Oyster Creek ESA Consultation: Information Requests from NMFS ML19158A2772019-05-28028 May 2019 NRR E-mail Capture - Oyster Creek ESA Consultation: Information Requests from NMFS ML19148A4392019-05-24024 May 2019 NMFS to NRC, Requests for Additional Information to Support Oyster Creek Reinitiated Section 7 Consultation 2022-08-23
[Table view] |
Text
John Richmond From: Timothy OHara ,
Sent: Sunday, November 02, 2008 11:55 PM To: John Richmond; John White; Richard Conte; Paul Kaufman
Subject:
RE: OC LRI Daily Update Oct 31 John & All,
'1) SB floor cracking: You may want to ask why they didn't identify the correct cause in 2006.
(2) Coating imperfections: I entered Bays 5, 1, 11, and 13. I was not (and did not intend to) performing a VT-I' inspection. The VT-i is supposed to be completed by Amergen - then we review the results. I don't think we should be performing the inspection for Amergen. Recall that Amergen had not completed any VT data sheets as of the end of the day on Thursday, 10/31/08.
1did discuss this issue with John White this evening., My recommendations are:
(a) Amergen should document the coating imperfections and have engineering disposition them. It could be just a coating defect or it could be due to actual corrosion on the drywell shell beneath the coating. There is an approved coating repair procedure.
(b) assuming that engineering says to repair the coating, they should remove the coating, in the affected area(s) to check for possible ongoing corrosion on the outside of the drywell, remove any corrosion if present, do a UT thickness measurement of the drywell shell in the affected area, decide what caused the corrosion and remove the cause, then recoat the repaired area. This should be repeated in all identified areas.
(C) I would assume that this imperfection was not present or visible in 2006, however, Amergen should tell us why it wasn't discovered in 2006.
Tim OHara E_1*. (b)(6) J From: John Richmond Sent: Sunday, November 02, 2008 2:02 PM To: Timothy OHara Cc: John White; Richard Conte
Subject:
RE: OC LRI Daily Update Oct 31 They have an IR on the floor cracking. Chris Hawkins and a GE NDE tech said that, in one bay there were no visible floor cracks during the initial inspection, and then later after an additional entry, they found a "new" crack. The current belief is that there may be voids between the cement floor and the floor epoxy coating.
There were also cracks in the moisture barrier seal, between the floor and the liner. They plan to rework all of the cracks.
On a second topic ... Pinhole Carbunkle, described below, was in Bay-1 1. One of the Bays you were in. It was partially visible from the opening, without going in all the way. Of course, knowing it was there in advance, ddhelp to find it. More to follow, later today.
From: Timothy OHara Sent: Sunday, November 02, 2008 12:52 PM To: John Richmond Cc: John White
Subject:
RE: OC LRI Daily Update Oct 31 John, a0ordu" with the Freedom of Infoffnem A~t ExwmonsO - 7 FMWPA __2. 00_
FYI.
The cracked floor in the sandbed is important because ifwater were to enter that sandbed it might not be directed to the sandbed drains and away from the exterior of the drywell.
Also, there were cracks in the sandbed floors in 2006. A few suggested questions to the licensee: (1) why are the cracks re-occurring? (2) what was the cause determined in 2006 and why weren't all sandbeds fixed so it wouldn't continue to happen?
Tim From: John Richmond Sent: Friday, October 31, 2008 8:21 PM To: Richard Conte; Darrell Roberts; Ronald Bellamy; David Pelton Cc: Jeffrey Kulp; Stephen Pindale; Michael Modes; Glenn Meyer; Marjorie McLaughlin; Justin Heinly; Timothy OHara; Diane Screnci; Joseph Schoppy
Subject:
OC LRI Daily Update Oct 31 OC LRI Outage Commitments Inspection Day 5 Drywell Structural Integrity Issues or Concerns
- 1) One sandbed bay (exterior drywell shell), appears to have a coating defect. Preliminary info is based on a verbal report, given to me during an impromptu status update, from the Exelon NDE Level-Ill Technical Lead for sandbed NDE. One bay had a pinhole in the drywell shell coating with some "bleed through" that was "rust colored." The NDE Level-Ill couldn't remember the bay number (there are pictures). I raised the question with Reg Affairs, as to whether this coating defect could be indicative of any "on-going corrosion" beneath the epoxy coating. In parallel with my talking with Reg Affairs, OC engineering got this information at about the same time that I did. Engineering is developing a plan to resolve this issue. Initial thoughts are to excavate
.the area to identify the cause (e.g., subsurface corrosion) and extend of condition. Plan and time table are TBD.
- 2) All sandbed bays have been NDE UT and VT examined (NDE examination records not yet, prepared). No other potential coating defects were identified. Some cracks in the.floor epoxy sealer and in the moisture barrier seal were identified, and are planned to be reworked. Rework plan and time table are TBD. Four sandbed bays were independently inspected by Tim O'Hara, only floor cracks in one bay were identified. Tim was not in the bay with the coating defect.
Inspection Progress
- 1) Progress remains Slow. Drywell NDE activities still behind schedule.
- 2) If AmerGen doesn't have sufficient NDE data available for review by COB Monday, I will probably reschedule the Exit.
Inspection Schedule
- 1) Currently plan to work Sunday. Have arranged for a telephone update tomorrow (Saturday) on sandbed coating defect. Am available to come in on Saturday, if needed.
- 2) Paul Kaufman will be on-site Monday to assist.
Today's Inspection Activities
- 1) Verified daily leakage checks on sandbed bay drain lines [no leakage] and cavity trough drain line [about as 1/8 inch stream]. Administrative limit on cavity trough leakage is < 12 gpm.
- 2) Inspected portions of a cable test. Nothing noteworthy.
(b)(5) "
2
(b)(5)
NJ State Interface Remains Good. Rich Pinney seems very satisfied.
Team Location: OCAB 2nd Floor, Visiting Exec Office, 609-9714830 3
Received: from RlCLSTRO1.nrc.gov ([148.184.99.71) by R1MS01.nrc.gov
([148.184.99.10]) with mapi; Sun, 2 Nov -2008 23:54:33 -0500 Content-Type: application/ms-tnef; name="winmail.dat" Content-Transfer-Encoding: binary From: Timothy OHara <Timothy.OHara@nrc.gov>
To: John Richmond <John.Richmond@nrc.gov>, John White <John.White@nrc.gov>,
Richard Conte <Richard.Conte@nrc.gov>, Paul Kaufman
<Paul. Kaufman@nrc.gov>
Date: Sun, 2 Nov 2008 23:54:33 -0500
Subject:
RE: OC LRI Daily Update Oct 31 Thread-Topic: OC LRI Daily Update Oct 31 Thread-Index:
Ack4gKEiWwVCl7a9S2m 917wfCwca0QAyjWwwAGMnHFAAM68PQABbL4SwAAJJiJAA FDowEA==
Message-ID:
<2856BC46F6A308418F033D973BBOEE72AA43652159@R1CLSTRO1.nrc.gov>
References:
<2856BC46F6A308418F033D973BBOEE72AA4363288D@R1CLSTRO1.nrc.gov>
<2856BC46F6A308418F033D973BBOEE72AA43632890@R1CLSTRO1.nrc.gov>
<2856BC46F6A308418F033D973BB0EE72AA436328A3@R 1CLSTR01.nrc.gov>
<2856BC46F6A308418F033D973BB0EE72AA436328AE@R lCLSTRO1. nrc.gov>
<2856BC46F6A308418F033D973BBOEE72AA43652158@R1 CLSTR01 .nrc.gov>
<2856BC46F6A308418F033D973BBOEE72AA436328C1 @R1 CLSTRO1.nrc.gov>
In-Reply-To:
<2856BC46F6A308418F033D973BBOEE72AA436328C1 @R1 CLSTR01.nrc.gov>
Accept-Language: en-US Content-Language: en-US X-MS-Has-Attach:
X-MS-Exchange-Organization-SCL: -1 X-MS-TN EF-Correlator:
<2856BC46F6A308418F033D973BBOEE72AA43652159@R lCLSTRO1 .nrc.gov>
MIME-Version: 1.0