Module 6: Air Pollutants and Control Techniques - Particulate Matter - Control Techniques l Basic Concepts in Environmental Sciences l APTI l USEPA Jump to main content.

BCES: Module 6: Air Pollutants/Control Techniques Contact Us Search:

All EPA This Area G You are here: EPA Home G Air & Radiation G Air Quality Planning & Standards G Air Pollution Training Institute G Basic Concepts in Environmental Sciences G Module Contents G Module 6: Air Pollutants and Control Techniques G Particulate Matter G Control Techniques Module 6: Air Pollutants and Control Techniques

- Particulate Matter - Control Techniques Features G Quick Reference G Glossary G Calculators G Help G A-Z Index G Full Contents http://www.epa.gov/apti/bces/module6/matter/control/control.htm (1 of 20)6/25/2009 1:27:44 PM Go

Module 6: Air Pollutants and Control Techniques - Particulate Matter - Control Techniques l Basic Concepts in Environmental Sciences l APTI l USEPA Introduction Gravity Settling Chambers Mechanical Collectors Particulate Wet Scrubbers Venturi Scrubbers Impingement Plate Scrubbers Spray Tower Scrubbers Wet Scrubbing Systems Scrubber Operating Principles Collection Efficiency of Wet Scrubbers Advantages and Disadvantages of Scrubbers Electrostatic Precipitators Types of Electrostatic Precipitators Advantages and Disadvantages of Electrostatic Precipitators Collection Efficiency of Electrostatic Precipitators Fabric Filters Operating Principles Types of Fabric Filters Advantages and Disadvantages of Fabric Filters General Applicability of Particulate Control Systems Practice Problems Objectives

1. Describe the basic designs of five different categories of particle control devices and the collection mechanisms they use.
2. Given a description of particulate matter and gas stream conditions, select appropriate particulate control devices for the situation.

Introduction http://www.epa.gov/apti/bces/module6/matter/control/control.htm (2 of 20)6/25/2009 1:27:44 PM

Module 6: Air Pollutants and Control Techniques - Particulate Matter - Control Techniques l Basic Concepts in Environmental Sciences l APTI l USEPA Within each of the five main categories of particulate control techniques, there are many different design types:

G Gravity settling chamber G Mechanical collectors G Particulate wet scrubbers G Electrostatic precipitators G Fabric filters Gravity Settling Chambers As the name implies, this category of control devices relies upon gravity settling to remove particles from the gas stream. Gravity settling chambers are used only for very large particles in the upper end of the supercoarse size range (approximately 75 micrometers and larger). The very low terminal settling velocities of most particles encountered in the field of air pollution limit the usefulness of gravity settling chambers. (See the lesson on Control Techniques in Module 3 for more information about terminal settling velocities.)

The stringent control requirements adopted in the late 1960s through early 1970s have resulted in a sharp decline in the use of this type of collector. There are very few gravity settling chambers still in commercial use.

Mechanical Collectors Mechanical collectors use the inertia of the particles for collection. The particulate-laden gas stream is forced to spin in a cyclonic manner. The mass of the particles causes them to move toward the outside of the vortex. Most of the large-diameter particles enter a hopper below the cyclonic tubes while the gas stream turns and exits the tube.

There are two main types of mechanical collectors: (1) large-diameter cyclones, and (2) small-diameter multi-cyclones. Large-diameter cyclones are usually one to six feet in diameter; while small-diameter multi-cyclones usually have diameters between 3 and 12 inches.

A typical large-diameter cyclone system is shown in Figure 1. The gas stream enters the cyclone tangentially and creates a weak vortex of spinning gas in the cyclone body. Large-diameter particles move toward the cyclone body wall and then settle into the hopper of the cyclone. The cleaned gas turns and exits the cyclone. Large-diameter cyclones are used to collect particles ranging in diameters from one-sixteenth inch to more than 6 inches.

http://www.epa.gov/apti/bces/module6/matter/control/control.htm (3 of 20)6/25/2009 1:27:44 PM

Module 6: Air Pollutants and Control Techniques - Particulate Matter - Control Techniques l Basic Concepts in Environmental Sciences l APTI l USEPA In systems where the large-diameter cyclone is located after the fan (positive pressure), the treated gas is usually discharged directly from the cyclone. In systems where the cyclone is located before the fan (negative pressure), the gas stream is either exhausted from a separate stack or from the discharge duct of the fan itself. In negative pressure systems, a solids discharge valve is used to prevent air infiltration up through the hopper area.

A small-diameter cyclone tube is shown in Figure 2. Vanes located on the inlet of each of the tubes create the spinning movement of the gas stream. Most of the commercial tubes are six, nine, or twelve inches in diameter. Due to the limited gas handling capacity of each tube, large numbers of tubes are mounted in parallel in a single collector.

http://www.epa.gov/apti/bces/module6/matter/control/control.htm (4 of 20)6/25/2009 1:27:44 PM

Module 6: Air Pollutants and Control Techniques - Particulate Matter - Control Techniques l Basic Concepts in Environmental Sciences l APTI l USEPA The small-diameter of the cyclone tube creates more rapid spinning of the gas stream than is possible in large-diameter cyclones. Furthermore, the particles moving outward in the spinning gas stream have a relatively shorter distance to travel in a small-diameter multi-cyclone tube before they reach the cyclone body wall. These features allow small-diameter multi-cyclones to collect considerably smaller particles than large-diameter cyclones can. Small-diameter multi-cyclones, such as the one shown in Figure 2 are capable of removing particles having diameters down to 5 micrometers. Conversely, the small-diameter multi-cyclones are not generally used for very large diameter material, such as one-eighth inch and above, because large particles may plug the spinner vanes in the multi-cyclone tubes.

Some mechanical collectors are specially designed to provide high-efficiency particulate matter collection down to a particle size of one micrometer. These have higher gas velocities within the cyclone tubes and different cyclone geometries than those shown in Figure 2.

A typical application of a conventional multi-cyclone collector is shown in Figure 3. In this example, the multi-cyclone is located after a small, wood-fired boiler and is used as a precollector for the fabric filter.

http://www.epa.gov/apti/bces/module6/matter/control/control.htm (5 of 20)6/25/2009 1:27:44 PM

Module 6: Air Pollutants and Control Techniques - Particulate Matter - Control Techniques l Basic Concepts in Environmental Sciences l APTI l USEPA Mechanical collectors are used whenever the particle size distributions generated by the process are relatively large (greater than 5 micrometers) and/or the control efficiency requirements are in the low-to-moderate range of 50 to 90%.

They are also used as the pre-collector of large-diameter embers generated in some combustion systems.

Removal of the embers is necessary to protect high-efficiency particulate control systems downstream from the mechanical collectors.

Most mechanical collectors are not applicable to industrial sources that generate sticky and/or wet particulate matter. These materials can accumulate on the cyclone body wall or the inlet spinner vanes of conventional multi-cyclone collectors.

Particulate Wet Scrubbers There are a number of major categories of particulate wet scrubbers. The list provided below is not exhaustive (nor is it listed in order of efficiency).

G Venturis http://www.epa.gov/apti/bces/module6/matter/control/control.htm (6 of 20)6/25/2009 1:27:44 PM

Module 6: Air Pollutants and Control Techniques - Particulate Matter - Control Techniques l Basic Concepts in Environmental Sciences l APTI l USEPA G Impingement and Sieve Plates G Spray Towers G Mechanically Aided G Condensation Growth G Packed Beds G Ejector G Mobile Bed G Caternary Grid G Froth Tower G Oriented Fiber Pad G Wetted Mist Eliminators This lesson discusses only three of the above types of scrubbers: venturis, impingement plate scrubbers, and spray towers.

Venturi Scrubbers A typical venturi throat is shown in Figure 4. Particulate matter, which accelerates as it enters the throat, is driven into the slow moving, large water droplets that are introduced near the high velocity point at the inlet of the venturi throat. The adjustable dampers in the unit illustrated are used to adjust the open cross-sectional area and thereby affect the speed of the particles entrained in the inlet gas stream.

Impingement Plate Scrubbers http://www.epa.gov/apti/bces/module6/matter/control/control.htm (7 of 20)6/25/2009 1:27:44 PM

Module 6: Air Pollutants and Control Techniques - Particulate Matter - Control Techniques l Basic Concepts in Environmental Sciences l APTI l USEPA An impingement plate scrubber is shown in Figure 5. These scrubbers usually have one to three horizontal plates, each of which has a large number of small holes. The gas stream accelerating through the holes atomizes some water droplets in the water layer above the plate. Particles impact into these water droplets.

Spray Tower Scrubbers A typical spray tower scrubber is shown in Figure 6. This is the simplest type of particulate wet scrubber in commercial service. Sets of spray nozzles located near the top of the scrubber vessel generate water droplets that impact with particles in the gas stream as the gas stream moves upwards.

http://www.epa.gov/apti/bces/module6/matter/control/control.htm (8 of 20)6/25/2009 1:27:44 PM

Module 6: Air Pollutants and Control Techniques - Particulate Matter - Control Techniques l Basic Concepts in Environmental Sciences l APTI l USEPA Each of the categories of particulate wet scrubbers listed earlier has a large number of different design types. For example, venturi scrubbers include the following different design types: (1) fixed throat, (2) adjustable throat, (3) collision (opposed-adjustable), (4) single rod decks, and (5) multiple rod decks.

Spray tower scrubbers include these design types: (1) open, (2) cyclonic, and (3) baffled spray towers.

The scrubber categories listed above comprise more than fifty different types of scrubbers in common commercial use. Scrubbers are by far the most diverse group of air pollution control devices used for particulate control.

Wet Scrubbing Systems Each particulate wet scrubber vessel is part of a large, and sometimes complex, wet scrubbing system.

For example, Figure 7 illustrates a venturi scrubber in a scrubbing system. The evaporative cooler, located before the venturi scrubber in the system, cools the gas stream, which serves the following purpose:

1. It protects the construction materials of the venturi throat.
2. It helps to homogeneously and heterogeneously nucleate vapor phase material emitted from the process before it reaches the scrubbing system.
3. It prevents the water droplets from evaporating and inhibiting inertial impaction.

http://www.epa.gov/apti/bces/module6/matter/control/control.htm (9 of 20)6/25/2009 1:27:44 PM

Module 6: Air Pollutants and Control Techniques - Particulate Matter - Control Techniques l Basic Concepts in Environmental Sciences l APTI l USEPA Located after the venturi scrubber, the cyclonic separator removes entrained water droplets from the gas stream leaving the venturi. The cyclonic separator consists of a cyclonic vessel and a horizontal mist eliminator. The overall scrubbing system includes pumps for liquid recirculation, a tank to treat the liquid being recirculated, an alkali addition unit to control the liquid pH, a purged liquid treatment unit, a fan for gas movement, and a stack. There are a wide variety of wet scrubber system designs; however, these components are present in many systems, regardless of which type of particulate matter scrubber is used.

Scrubber Operating Principles The numerous different types of particulate wet scrubbers mentioned earlier have some important common characteristics, which allow for a general discussion about wet scrubber operating principles and applicability. All particulate wet scrubber designs utilize particle and/or droplet inertia as the fundamental force to transfer particles from the gas stream to the liquid stream. Within the scrubber, particle-laden air is forced to contact the liquid droplets, sheets of liquid on a packing material, or jets of liquid from a plate. Particles with too much inertia impact on the water droplet, water sheet, or water jet instead of passing around the "target" with the gas stream.

Note: Two important particle collection mechanisms for scrubbers, inertial impaction and interception, http://www.epa.gov/apti/bces/module6/matter/control/control.htm (10 of 20)6/25/2009 1:27:44 PM

Module 6: Air Pollutants and Control Techniques - Particulate Matter - Control Techniques l Basic Concepts in Environmental Sciences l APTI l USEPA are discussed in the lesson on Collection Mechanisms in Module 3.

The ability of a particulate wet scrubber to remove particles depends on two or more of the following variables:

G The size (aerodynamic diameter) of the particle G The velocity of the particle G The velocity of the droplet, sheet, or jet The venturi scrubber throat shown in Figure 4 illustrates these principles. The collection efficiency increases as the gas stream accelerates upon entering the throat. The large, 100- to 1,000-micrometer water droplets formed from the inlet stream move relatively slowly compared with the small-diameter particles in the accelerating gas stream. Due to the difference in the velocities of the particles and droplets, inertial impaction and interception occur in the venturi throat. The effectiveness of the impaction increases for larger particles. The importance of the difference in velocity and the particle size is discussed in more detail in Module 3. (See the section on Inertial Impaction and Interception in the lesson on Collection Mechanisms.)

Collection Efficiency of Wet Scrubbers All of the particulate wet scrubbers in commercial use depend on inertial impaction. However, the velocities of the particle-laden gas stream and the liquid targets vary substantially. Accordingly, there are substantial differences in the ability of particulate wet scrubbers to collect particles less than approximately 5 micrometers. This is illustrated in Figure 8. If a significant portion of the particulate matter mass is composed of particles less than 5 micrometers, care is needed to select the type of scrubber that is effective in this size range.

http://www.epa.gov/apti/bces/module6/matter/control/control.htm (11 of 20)6/25/2009 1:27:44 PM

Module 6: Air Pollutants and Control Techniques - Particulate Matter - Control Techniques l Basic Concepts in Environmental Sciences l APTI l USEPA It should be noted that some types of wet scrubbers have limited capability to remove particles in the less than 0.3-micrometer range. Methods of particle collection in this very small size range take advantage of these particles' tendencies to diffuse slowly due to their interactions with gas molecules (Brownian diffusion). In other words, these particles are so small that their movement is influenced by collisions with individual molecules in the gas stream.

Advantages and Disadvantages of Scrubbers Many types of particulate wet scrubbers can provide high efficiency control of particulate matter. One of the main advantages of particulate wet scrubbers is that they are often able to simultaneously collect particulate matter and gaseous pollutants. Also, wet scrubbers can often be used on sources that have potentially explosive gases or particulate matter. They are compact and can often be retrofitted into existing plants with very limited space.

One of the main disadvantages of particulate wet scrubbers is that they require make-up water to replace the water vaporized into the gas stream and lost to purge liquid and sludge removed from the scrubber system. Wet scrubbers generate a waste stream that must be treated properly.

Electrostatic Precipitators Types of Electrostatic Precipitators An electrostatic precipitator (ESP) uses nonuniform, high-voltage fields to apply large electrical charges http://www.epa.gov/apti/bces/module6/matter/control/control.htm (12 of 20)6/25/2009 1:27:44 PM

Module 6: Air Pollutants and Control Techniques - Particulate Matter - Control Techniques l Basic Concepts in Environmental Sciences l APTI l USEPA to particles moving through the field. The charged particles move toward an oppositely charged collection surface, where they accumulate.

There are three main styles of electrostatic precipitators: (1) negatively charged dry precipitators, (2) negatively charged wetted-wall precipitators, and (3) positively charged two-stage precipitators. The negatively charged dry precipitators are the type most frequently used on large applications such as coal-fired boilers, cement kilns, and kraft pulp mills. Wetted-wall precipitators (sometimes called wet precipitators) are often used to collect mist and/or solid material that is moderately sticky. The positively charged two-stage precipitators are used only for the removal of mists. In the remainder of this section, the discussions will focus only on negatively charged dry precipitators because these are the most common types of precipitators.

Figure 9 shows the scale of a typical electrostatic precipitator used at a coal-fired boiler.

Essentially all of these units are divided into a number of separately energized areas that are termed fields (see Figure 10). Most precipitators have between three and ten fields in series along the gas flow path. On large units, the precipitators are divided into a number of separate, parallel chambers, each of which has an equal number of fields in series. There is a solid partition or physical separation between the 2 to 8 chambers that are present on the large systems.

http://www.epa.gov/apti/bces/module6/matter/control/control.htm (13 of 20)6/25/2009 1:27:44 PM

Module 6: Air Pollutants and Control Techniques - Particulate Matter - Control Techniques l Basic Concepts in Environmental Sciences l APTI l USEPA Figure 11 shows a single gas passage in a typical electrostatic precipitator. A high-voltage electrical charge is applied to the small-diameter electrode shown in the center of the picture. The large vertical surfaces on both sides of the electrode are electrically grounded collection plates. The particles in the gas stream, which is moving horizontally through the unit (into the photograph shown in Figure 11), become charged and then move to either side.

Advantages and Disadvantages of ESPs Electrostatic precipitators can have very high efficiencies due to the strong electrical forces applied to the small particles. These types of collectors can be used when the gas stream is not explosive and does not contain entrained droplets or other sticky material.

http://www.epa.gov/apti/bces/module6/matter/control/control.htm (14 of 20)6/25/2009 1:27:44 PM

Module 6: Air Pollutants and Control Techniques - Particulate Matter - Control Techniques l Basic Concepts in Environmental Sciences l APTI l USEPA The composition of the particulate matter is very important because it influences the electrical conductivity within the dust layers on the collection plate. Resistivity, an important concept associated with electrostatic precipitators, is a measure of the ability of the particulate matter to conduct electricity and is expressed in units of ohm-cm. As the resistivity increases, the ability of the particulate matter to conduct electricity decreases. Precipitators can be designed to work in any resistivity range; however, they usually work best when the resistivity is in the moderate range (108 to 1010 ohms-cm).

Collection Efficiency of ESPs The typical Particle Size - Collection Efficiency curve for a properly sized and operated electrostatic precipitator is shown in Figure 12. The efficiency is usually at a minimum in the range of 0.1 to 0.5 micrometers. The shape of the efficiency curve is the combined effect of two particle electrical charging mechanisms, neither of which is highly effective in this particle size range. It should be noted that this decrease in efficiency occurs in the same particle size range as for particulate wet scrubbers. However, the reason for this decreased efficiency zone is entirely different than that for particulate wet scrubbers.

Fabric Filters Operating Principles Fabric filters collect particulate matter on the surfaces of filter bags. Most of the particles are captured by inertial impaction, interception, Brownian diffusion, and sieving on already collected particles that have formed a dust layer on the bags. (Inertial impaction, interception, and Brownian diffusion are discussed further in the lesson on Collection Mechanisms in Module 3.) The fabric material itself can http://www.epa.gov/apti/bces/module6/matter/control/control.htm (15 of 20)6/25/2009 1:27:44 PM

Module 6: Air Pollutants and Control Techniques - Particulate Matter - Control Techniques l Basic Concepts in Environmental Sciences l APTI l USEPA capture particles that have penetrated through the dust layers. Electrostatic attraction may also contribute to particle capture in the dust layer and in the fabric itself. Due to the multiple mechanisms of particle capture possible, fabric filters can be highly efficient for the entire particle size range of interest in air pollution control.

Types of Fabric Filters A reverse-air-type fabric filter, shown in Figure 13, is one of the major categories of fabric filters. It is used mainly for large industrial sources. In this type of unit, the particle-laden gas stream enters from the bottom and passes into the inside of the bags. The dust cake accumulates on the inside surfaces of the bags. Filtered gas passes through the bags and is exhausted from the unit.

When cleaning is necessary, dampers are used to isolate a compartment of bags from the inlet gas flow.

Then, some of the filtered gas passes in the reverse direction (from the outside of the bag to the inside) in order to remove some of the dust cake. The gas used for reverse air cleaning is re-filtered and released.

Another common type of fabric filter is the pulse jet shown in Figure 14. In this type of unit, the bags are supported on metal wire cages that are suspended from the top of the unit. Particulate-laden gas flows around the outside of the bags, and a dust cake accumulates on the exterior surfaces. When cleaning is needed, a very-short-duration pulse of compressed air is injected at the top inside part of each bag in the row of bags being cleaned. The compressed air pulse generates a pressure wave that moves down each bag and, in the process, dislodges some of the dust cake from the bag.

http://www.epa.gov/apti/bces/module6/matter/control/control.htm (16 of 20)6/25/2009 1:27:44 PM

Module 6: Air Pollutants and Control Techniques - Particulate Matter - Control Techniques l Basic Concepts in Environmental Sciences l APTI l USEPA Advantages and Disadvantages of Fabric Filters Fabric filters are used in a wide variety of applications where high efficiency particulate collection is needed. The control efficiencies usually range from 99% to greater than 99.5% depending on the characteristics of the particulate matter and the fabric filter design. As mentioned earlier, fabric filters can be very efficient at collecting particles in the entire size range of interest in air pollution control.

The performance of fabric filters is usually independent of the chemical composition of the particulate matter. However, they are not used when the gas stream generated by the process equipment includes corrosive materials that could chemically attack the filter media. Fabric filters are also not used when there are sticky or wet particles in the gas stream. These materials accumulate on the filter media surface and block gas movement.

Fabric filters must be designed carefully if there are potentially combustible or explosive particulate matter, gases, or vapors in the gas stream being treated. If these conditions are severe, alternative control techniques, such as wet scrubbers, are often used.

General Applicability of Particulate Control Systems http://www.epa.gov/apti/bces/module6/matter/control/control.htm (17 of 20)6/25/2009 1:27:44 PM

Module 6: Air Pollutants and Control Techniques - Particulate Matter - Control Techniques l Basic Concepts in Environmental Sciences l APTI l USEPA Particulate matter control systems are often selected based on the general criteria listed in Figure 15.

If there is a high concentration of wet and/or sticky particulate matter, either a particulate wet scrubber or a wet electrostatic precipitator is used. If wet or sticky materials are present with combustible materials or explosive gases or vapors, the particulate wet scrubber is most appropriate.

If the particulate matter is primarily dry, mechanical collectors, particulate wet scrubbers, conventional electrostatic precipitators, and fabric filters can be used. The next step in the selection process is to determine if the particulate matter and/or gases and vapors in the gas stream are combustible or explosive. If so, then mechanical collectors or particulate wet scrubbers can be used because both of these categories of systems can be designed to minimize the risks of ignition. In some cases, a fabric filter can also be used if it includes the appropriate safety equipment. An electrostatic precipitator is not used due to the risk of ignition caused by electrical sparking in the precipitator fields. When selecting between mechanical collectors and wet scrubbers, mechanical collectors are the more economical choice. They have a lower purchase cost and a lower operating cost than wet scrubbers.

If the dry particulate matter is present in a gas stream that is not combustible or explosive, the selection depends on the particle size range and the control efficiency requirements. If a significant portion of the gas stream is in the less than 0.5-micrometer size range, and high efficiency control is needed, a fabric filter is the most common choice. If a significant portion of the particulate matter is in the 0.5-to 5-micrometer size range, and high efficiency control is needed, fabric filters, electrostatic precipitators, or particulate wet scrubbers (certain types) could be used. If most of the particulate matter is larger than 5 micrometers, any of the four main types of particulate control systems could be used.

http://www.epa.gov/apti/bces/module6/matter/control/control.htm (18 of 20)6/25/2009 1:27:44 PM

Module 6: Air Pollutants and Control Techniques - Particulate Matter - Control Techniques l Basic Concepts in Environmental Sciences l APTI l USEPA There are numerous exceptions to the general applicability information presented above due to site-specific process conditions and unique particulate matter control systems. Nevertheless, this chart provides a general indication of the uses and limitations of many commercially available particulate matter control systems.

Practice Problems Particulate Matter - Control Techniques Instructions:

Complete the Practice Problems before proceeding to the next lesson. Click on the button below.

Practice Problems Previous Section Particulate Matter:

Formation Mechanisms Next Lesson Sulfur Oxides:

Contents APTI Virtual Classroom Local Navigation G Module 6:

Air Pollutants and Control Techniques G Particulate Matter G Sulfur Oxides G Ozone G Volatile Organic Compounds G Incompletely Oxidized Compounds http://www.epa.gov/apti/bces/module6/matter/control/control.htm (19 of 20)6/25/2009 1:27:44 PM

Module 6: Air Pollutants and Control Techniques - Particulate Matter - Control Techniques l Basic Concepts in Environmental Sciences l APTI l USEPA G Dioxins and Furans G Halogens G Review Exercises G EPA Home G Privacy and Security Notice G Contact Us G Share H Del.icio.us H Digg H Facebook H reddit H Slashdot H StumbleUpon H What is this?

Last updated on Friday, April 4th, 2008.

http://www.epa.gov/apti/bces/module6/matter/control/control.htm Print As-Is Jump to main content.

http://www.epa.gov/apti/bces/module6/matter/control/control.htm (20 of 20)6/25/2009 1:27:44 PM