ML091670358
| ML091670358 | |
| Person / Time | |
|---|---|
| Site: | Browns Ferry (DPR-052) |
| Issue date: | 07/01/2009 |
| From: | Ellen Brown Plant Licensing Branch II |
| To: | Swafford P Tennessee Valley Authority |
| Sreenivas V.NRR/DORL/LPL2-1 415-2597 | |
| References | |
| 2-ISI-22, TAC ME1320 | |
| Download: ML091670358 (2) | |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 July 1,2009 Mr. Preston D. Swafford Chief Nuclear Officer and Executive Vice President Tennessee Valley Authority 3A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801
SUBJECT:
BROWNS FERRY NUCLEAR PLANT UNIT 2 - WITHDRAWAL OF RELIEF REQUEST (2-ISI-22) FOR REPAIR OF CLASSES 1, 2, AND 3AUSTENITIC STAINLESS STEEL PIPING (TAC NO. ME1320)
Dear Mr. Swafford:
By letter dated May 18, 2009, the Tennessee Valley Authority, the licensee submitted a relief request (RR) for Browns Ferry Nuclear Power Plant, Unit 2 to the U.S. Nuclear Regulatory Commission (NRC). The proposed RR was to utilize a system leakage test in accordance with IWA-5000 in lieu of the hydrostatic test required by Code Case N-504-3.
By letter dated May 21, 2009, the licensee requested to withdraw RR 2-ISI-22 application from NRC review (Agencywide Document Access and Management System Accession No. ML091470283) due to the fact that the flaw did not penetrate the pressure boundary during welding operations. We acknowledge your request to withdraw the application. As a result, NRC staff activities on the review have ceased and the associated Technical Assignment Control Number (No. ME1320) has been closed.
If you have any questions, please contact me at 301-415-2315.
Sincerely, IRA!
Eva A. Brown, Senior Project Manager Plant Licensing Branch 11-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No.: 50-260 cc: Distribution via ListServ
Mr. Preston D. Swafford Chief Nuclear Officer and Executive Vice President Tennessee Valley Authority 3A Lookout Place 11 01 Market Street Chattanooga, TN 37402-2801
SUBJECT:
BROWNS FERRY NUCLEAR PLANT UNIT 2 - WITHDRAWAL OF RELIEF REQUEST (2-ISI-22) FOR REPAIR OF CLASSES 1, 2, AND 3 AUSTENITIC STAINLESS STEEL PIPING (TAC NO. ME1320)
Dear Mr. Swafford:
By letter dated May 18, 2009, the Tennessee Valley Authority, the licensee submitted a relief request (RR) for Browns Ferry Nuclear Power Plant, Unit 2 to the U.S. Nuclear Regulatory Commission (NRC). The proposed RR was to utilize a system leakage test in accordance with IWA-5000 in lieu of the hydrostatic test required by Code Case N-504-3.
By letter dated May 21, 2009, the licensee requested to withdraw RR 2-ISI-22 application from NRC review (Agencywide Document Access and Management System Accession No. ML091470283) due to the fact that the flaw did not penetrate the pressure boundary during welding operations. We acknowledge your request to withdraw the application. As a result, NRC staff activities on the review have ceased and the associated Technical Assignment Control Number (No. ME1320) has been closed.
If you have any questions, please contact me at 301-415-2315.
Sincerely, IRA!
Eva A. Brown, Senior Project Manager Plant Licensing Branch 11-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No.: 50-260 cc: Distribution via ListServ Distribution:
PUBLIC RidsNrrPMEBrown RidsAcrsAcnwMailCenter JAdams, EDO LPL2-2 R/F RidsOgcRp VSreenives, NRR JCollins, NRR RidsNrrDorlLpl2-2 RidsNrrDciCpnb RidsRgn2MailCenter RidsNrrLABClayton(hard copy)
ADAMS ACCESSION NUMBER' ML091670358 NRR-028 OFFICE LP-WB/PM LPL2-2/PM LPL2-2/LA LPL2-2/BC NAME VSreenivas EBrown BClayton TBoyce DATE 7/1/09 7/1/09 7/1/09 7/1/09 OFFICIAL RECORD COpy