E-mail from J. Richmond of USNRC to D. Screnci, N. Sheehan and R. Bellamy of USNRC, Regarding Oyster Creek Outage Inspection of License Renewal Commitments
ML091190088
Person / Time
Site: Oyster Creek
Issue date: 10/15/2008
From: Richmond J
Engineering Region 1 Branch 1
To: Bellamy R, Diane Screnci, Neil Sheehan
Office of Public Affairs Region I, NRC/RGN-I/DRP/PB6
References
FOIA/PA-2009-0070
Download: ML091190088 (2)


Text

'i, Elizabeth Keighley From: John Richmond ?11 Sent: Wednesday, October 15, 2008 1:05 PM To: Diane Screnci; Neil Sheehan; Ronald Bellamy Cc: Richard Conte; Michael Modes; Glenn Meyer; Timothy OHara

Subject:

Oyster Creek Outage Inspection of License Renewal Commitments Diane, per our discussion this morning, I understand no comm plan is needed (or desired) regarding the upcoming OC outage license renewal (LR) inspection.

Below is a summary overview of our planned inspection activities, to verify AmerGen's implementation of LR commitments. DRS will implement the outage portion of IP 71003. The inspection is scheduled for 1-week, using 3 inspectors. The inspection may run into a second week, depending on outage work schedules. The non-outage portion of IP 71003 is a Team inspection (TL + 4), and is currently scheduled for March 2009.

OC Outage Inspection of License Renewal Commitments This is not a complete list, and some bullets have many separate inspection tasks.

  • Verify AmerGen's drywell liner (steel shell) thickness verifications

" Independently verify & evaluate conditions (i.e., water accumulation) in the two floor trenches inside the drywell

  • Independently verify & evaluate whether any water leakage is occurring on the outside of the drywell liner, in the sandbed regions. In the past, when the reactor refuel cavity was flooded, water leaked past the cavity seal and onto the outside of the drywell liner.

" Verify selected samples of AmerGen's electrical testing of inaccessible medium voltage cables

  • Verify AmerGen's inspection of electrical cables inside the drywell (adverse localized environment), for indications of accelerated insulation aging e Verify AmerGen's inspection & testing of an isolation condenser, for stress corrosion cracking, or pitting corrosion
  • Verify AmerGen's structural inspection and evaluation of emergency service water intake structure & piping, including below the water line
  • Verify selected samples of AmerGen's 1-time inspections, to verify assumptions in their LR Application that no adverse aging effects exist (i.e., verifies that no aging management program is needed)
  • Verify selected samples of AmerGen's routine surveillances to monitor SSC for indications of adverse aging effects Other OC Outage Activities of Interest Ron, please add any additional details of the OC outage as may be useful for Diane Please let me know if you need any additional information John Richmond

Received: from R1CLSTR01.nrc.gov ([148.184.99.7]) by R1MS01.nrc.gov

([148.184.99.10]) with mapi; Wed, 15 Oct 2008 13:05:13 -0400 Content-Type: application/ms-tnef; name="winmail.dat" Content-Transfer-Encoding: binary From: John Richmond <John.Richmond@nrc.gov>

To: Diane Screnci <Diane.Screnci@nrc.gov>, Neil Sheehan

<Neil.Sheehan@nrc.gov>, Ronald Bellamy <Ronald.Bellamy@nrc.gov>

CC: Richard Conte <Richard. Conte@nrc.gov>, Michael Modes

<Michael.Modes@nrc.gov>, Glenn Meyer <Glenn.Meyer@nrc.gov>, Timothy OHara

<Timothy.OHara@nrc.gov>

Date: Wed, 15 Oct 2008 13:05:11 -0400

Subject:

Oyster Creek Outage Inspection of License Renewal Commitments Thread-Topic: Oyster Creek Outage Inspection of License Renewal Commitments Thread-Index: Acku6C9bJtsLGcNXTuO3gNFNUEiROA==

Message-ID:

<2856BC46F6A308418F033D973BBOEE72AA29FF9C5B@R 1CLSTRO1. nrc.gov>

Accept-Language: en-US Content-Language: en-US X-MS-Has-Attach:

X-MS-Exchange-Organization-SCL: -1 X-MS-TNEF-Correlator:

<2856BC46F6A308418F033D973BBOEE72AA29FF9C5B@R1 CLSTR01.nrc.gov>

MIME-Version: 1.0