From:
Farideh Saba Sent:
Friday, March 27, 2009 10:19 AM To:
Westcott, Daniel Cc:
Marshall David
Subject:
CRYSTAL RIVER 3 ROD EJECTION UNDER EPU CONDITIONS (ME0730)
- Dan, The Nuclear Regulatory Commission (NRC) staff has assessed the submittal by Florid Power Corporation, dated February 26, 2009, for Crystal River Unit 3 - Licensee Amendment Request
- 307, Revision 0, "Methodology for Rod Ejection Accident Analysis under Extended Power Uprate Conditions." The NRC staff performed a cursory review to determine its technical contents and sufficiency. The staff finds the submittal is adequately detailed and includes sufficient discussion on methods validation to warrant a review. The NRC staff has determined that the submittal is acceptable for detailed technical review under LIC-109. If additional information is needed for the NRC staff to complete its technical review, you will be advised by separate correspondence.
If you have any questions, please contact me at (301) 415-1447.
Respectfully, Farideh E. Saba, P.E.
Senior Project Manager NRC/ADRO/NRR/DORL 301-415-1447 Mail Stop O-8G9A Farideh.Saba@NRC.GOV From: Anthony Attard Sent: Thursday, March 26, 2009 10:55 AM To: Farideh Saba Cc: Anthony Mendiola; Hans Ludewig
Subject:
RE: CRYSTAL RIVER 3 ROD EJECTION UNDER EPU CONDITIONS"
- Farideh, The SNPB branch staff has assessed the submittal by Crystal River -3 Rod Ejection Accident Methodology Report (ANP-2788P), dated XXX?, in support of an application by Florida Power Corporation (FPC) for License Amendment Request (LAR) in connection with an Extended Power Up-rate (EPU). The SNPB staff performed (with the help of Brookhaven National Laboratory (BNL) a cursory review to the determine its technical contents and sufficiency. The staff finds the submittal is adequately detailed and includes sufficient discussion on methods validation to warrant a review.
Anthon C. Attard 301-415-2876
E-mail Properties Mail Envelope Properties ()
Subject:
CRYSTAL RIVER 3 ROD EJECTION UNDER EPU CONDITIONS (ME0730)
Sent Date: 3/27/2009 9:58:31 AM Received Date: 3/27/2009 10:18:00 AM From: Farideh Saba Created By: Farideh.Saba@nrc.gov Recipients:
Daniel.Westcott@pgnmail.com (Westcott, Daniel)
Tracking Status: None Marshall.David@nrc.gov (Marshall David)
Tracking Status: None Post Office:
Files Size Date & Time MESSAGE 10842 3/27/2009 Options Expiration Date:
Priority: olImportanceNormal ReplyRequested: False Return Notification: False Sensitivity: olNormal Recipients received: