ES-401 GG-2009-03 Written Examination Review Worksheet Form ES-401-9

1. 2. 3. Psychometric Flaws 4. Job Content Flaws 5. Other 6. 7. 8.

Q# LOK LOD (F/H) (1-5) Stem Cues T/F Cred. Partial Job- Minutia #/ Back- Q= SRO B/M/N U/E/S Explanation Focus Dist. Link units ward K/A Only 1 F 2 N S Edited stem for clarity 2 F 2 N S 3 F 3 N S 4 H 2 N S Need to status the Recirc Pumps in the stem since the cooldown is initiated while E attempting to restart the pumps and prevent thermal stratification (steps 3.9.4 and 5 H 3 E N 3.9.5).

S The stem was revised to include the status of the recirc pumps.

6 F 2 N S Edited stem for clarity.

7 F 2 N S 8 H 3 N S Instructions

[Refer to Section D of ES-401 and Appendix B for additional information regarding each of the following concepts.]

1. Enter the level of knowledge (LOK) of each question as either (F)undamental or (H)igher cognitive level.
2. Enter the level of difficulty (LOD) of each question using a 1 B 5 (easy B difficult) rating scale (questions in the 2 B 4 range are acceptable).
3. Check the appropriate box if a psychometric flaw is identified:

$ The stem lacks sufficient focus to elicit the correct answer (e.g., unclear intent, more information is needed, or too much needless information).

$ The stem or distractors contain cues (i.e., clues, specific determiners, phrasing, length, etc).

$ The answer choices are a collection of unrelated true/false statements.

$ The distractors are not credible; single implausible distractors should be repaired, more than one is unacceptable.

$ One or more distractors is (are) partially correct (e.g., if the applicant can make unstated assumptions that are not contradicted by stem).

4. Check the appropriate box if a job content error is identified:

$ The question is not linked to the job requirements (i.e., the question has a valid K/A but, as written, is not operational in content).

$ The question requires the recall of knowledge that is too specific for the closed reference test mode (i.e., it is not required to be known from memory).

$ The question contains data with an unrealistic level of accuracy or inconsistent units (e.g., panel meter in percent with question in gallons).

$ The question requires reverse logic or application compared to the job requirements.

5. Check questions that are sampled for conformance with the approved K/A and those that are designated SRO-only (K/A and license level mismatches are unacceptable).
6. Enter question source: (B)ank, (M)odified, or (N)ew. Check that (M)odified questions meet criteria of ES-401 Section D.2.f.
7. Based on the reviewer=s judgment, is the question as written (U)nsatisfactory (requiring repair or replacement), in need of (E)ditorial enhancement, or (S)atisfactory?
8. At a minimum, explain any AU@ ratings (e.g., how the Appendix B psychometric attributes are not being met). Page 1 of 8 OBDI 202 - IOLE Process

ES-401 GG-2009-03 2 Form ES-401-9

1. 2. 3. Psychometric Flaws 4. Job Content Flaws 5. Other 6. 7. 8.

Q# LOK LOD (F/H) (1-5) Stem Cues T/F Cred. Partial Job- Minutia #/ Back- Q= SRO B/M/N U/E/S Explanation Focus Dist. Link units ward K/A Only 9 F 3 N S Edited stem for clarity U KA mismatch. Does not address focus on refuel accidents.

10 F 3 U N S The stem was revised to reinforce the applicability to refueling accidents.

11 H 3 N S 12 H 3 N S Question was replaced after audit exam.

13 F 2 N S 14 F 2 N S KA mismatch. The only item needed to answer this question is knowledge of the U

15 H 2 U N design maximum pressure of containment.

S This question was rewritten.

16 F 3 N S Edited stem for clarity Since there is no flow/head correlation curve given, the applicant could default to zero gpm. The elicited response needs to focus on knowledge of the effects on LCPS. As U written, the applicant could incorrectly decide that LPCS has not started and get the 17 H 3 U U N answer correct. Need to change answers to pump status and (discharge valve or S

flow status).

This question was revised to address this comment.

As written, there could be no correct answer. The current pressure is within the E nominal control band. Level is currently passing through the upper portion of the 18 H 3 E N ATWS control band, so I would expect no reductions in pressure to be made.

S This question was revised.

19 F 2 N S 20 F 2 N S 21 H 3 N S KA mismatch. Low water level (ie EOP entry condition) does not exist. Lots of U

22 H 2 U N examples in EOP for this KA. (Fuel zone level/temperature effects etc.)

S This question was revised.

23 H 2 N S U KA mismatch. Does not address increased cooling all coolers; containment spray.

24 F 2 U N S This question is ok as written because the reason for initiating containment sprays is Page 2 of 8 OBDI 202 - IOLE Process

ES-401 GG-2009-03 3 Form ES-401-9

1. 2. 3. Psychometric Flaws 4. Job Content Flaws 5. Other 6. 7. 8.

Q# LOK LOD (F/H) (1-5) Stem Cues T/F Cred. Partial Job- Minutia #/ Back- Q= SRO B/M/N U/E/S Explanation Focus Dist. Link units ward K/A Only to maintain containment temperature below the design temperature limits which is the same reason for increasing containment cooling per the EOPs.

25 F 3 N S KA mismatch. This is a system level question, not E/APE Loss of CRD pumps. Right now, the question centers on both CRD pumps running and the effects this will have U

26 H 2 U N on the CRD system.

S This question is ok since rod drifts will result in reactivity control issues as defined by the KA.

27 H 3 N S This question was rewritten to address the comment on question 95.

28 H 2 N S 29 F 2 N S Answer A is a give-away. The answer is modified with never before used, and cues U

30 H 2 U N in on an infrequent procedure.

S This question was replaced.

E Recommend rewriting the stem as indicated on the markup.

31 F 2 N S This question is ok as is.

32 H 3 N S 33 F 3 N S 34 F 2 N S 35 H 3 N S 36 F 3 N S 37 F 3 N S 38 H 2 N S Minor edits of answers completed.

39 H 3 N S 40 H 3 N S 41 F 2 N S Minor edit to stem completed.

42 H 3 N S 43 H 3 N S Page 3 of 8 OBDI 202 - IOLE Process

ES-401 GG-2009-03 4 Form ES-401-9

1. 2. 3. Psychometric Flaws 4. Job Content Flaws 5. Other 6. 7. 8.

Q# LOK LOD (F/H) (1-5) Stem Cues T/F Cred. Partial Job- Minutia #/ Back- Q= SRO B/M/N U/E/S Explanation Focus Dist. Link units ward K/A Only 44 H 3 N S As written, this parallels K4.05, paralleling interlock design features. Need to focus U

45 H 4 U N on fundamentals of paralleling 2 AC sources.

S This question was rewritten.

46 H 2 N S 47 F 2 N S E See markup.

48 F 2 N S This question is correct as written.

U Verify this answer in the references. Explanation does not support the given answer.

49 F 3 N S The explanations were revised to address this comment.

50 H 2 N S E See markup.

51 F 2 N S Comment was incorporated.

See markup.

52 H 3 N E Comment was incorporated.

53 F 2 N S E Add ONLY to the stem.

54 F 2 N S This question is OK as written.

55 F 2 N S 56 H 3 N S 57 H 3 N S 58 H 2 N S 59 F 2 N S 60 H 3 N S This is a K2 question as written. KA mismatch.

U This question is OK as written. The KA requires the question focus on the physical 61 F 3 U N S connections between the main turbine control system and DC power and the question tests on this. Page 4 of 8 OBDI 202 - IOLE Process

ES-401 GG-2009-03 5 Form ES-401-9

1. 2. 3. Psychometric Flaws 4. Job Content Flaws 5. Other 6. 7. 8.

Q# LOK LOD (F/H) (1-5) Stem Cues T/F Cred. Partial Job- Minutia #/ Back- Q= SRO B/M/N U/E/S Explanation Focus Dist. Link units ward K/A Only UE Both C and D are correct. Change D to The suction valve closing after 15 seconds.

62 H 3 U N S Distractor C was rewritten.

63 H 3 N S 64 H 3 N S 65 F 3 N S 66 F 2 N S 67 H 3 N S 68 F 2 N S 69 F 3 N S 70 F 3 N S 71 H 3 N S Need to add maximum to stem, or verify that the distractor values are not below the E

72 F 2 N maximum values for the respective conditions.

S This comment has been incorporated.

73 F 2 N S 74 H 2 N S 75 H 2 N S 76 H 2 N S 77 H 3 N S 78 H 4 N S U KA mismatch. Does not address reactor pressure.

79 H 2 U N S This question was replaced.

RO knowledge. The applicant only needs to know how ED is performed.

U This question is ok as written because it tests on procedure selection and a choice of 80 F 2 U N S methods of depressurizing. Both options are procedurally allowed but only one is correct in this situation.

81 H 3 N E Same knowledge requirement as Q78 - when level cant be determined, enter EP-5 Page 5 of 8 OBDI 202 - IOLE Process

ES-401 GG-2009-03 6 Form ES-401-9

1. 2. 3. Psychometric Flaws 4. Job Content Flaws 5. Other 6. 7. 8.

Q# LOK LOD (F/H) (1-5) Stem Cues T/F Cred. Partial Job- Minutia #/ Back- Q= SRO B/M/N U/E/S Explanation Focus Dist. Link units ward K/A Only S This question was rewritten.

Series of true/false statements.

U 82 F 2 U N This question is ok as written - the distractors are not stand alone true/false S

statements.

83 F 2 N S U This does not clearly address the reactor pressure in the KA 84 F 3 U N S Revised 85 H 4 N S Removed the hours after the 0700 86 H 2 N S Do not supply reference since all actions are <= 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />.

E This question was modified. The reference is needed as not all the distractors have 87 H 2 N S actions that are one hour or less. This question is testing on selecting the correct action statement.

E Remove all of the hours in this question.

88 H 2 N S This comment was incorporated.

89 H 3 N S 90 H 2 N S 91 F 2 N S 92 H 3 N S 93 F 3 N S 94 F 2 N S U This question is the same as one of the RO questions ->enter SAPS based on H2 95 F 3 N S Rewrote question 27 on the RO exam.

96 F 2 N S All of the explanations are incorrect. This is borderline RO since MCPR is a E 55.41(14) knowledge requirement.

97 F 2 N S The explanations have been corrected. This is an SRO question because it tests on the specific tech spec bases for this safety limit. Page 6 of 8 OBDI 202 - IOLE Process

ES-401 GG-2009-03 7 Form ES-401-9

1. 2. 3. Psychometric Flaws 4. Job Content Flaws 5. Other 6. 7. 8.

Q# LOK LOD (F/H) (1-5) Stem Cues T/F Cred. Partial Job- Minutia #/ Back- Q= SRO B/M/N U/E/S Explanation Focus Dist. Link units ward K/A Only RO knowledge. SRO should have to evaluate something below the line in TS after U

98 H 2 U N choosing the correct TS.

S This question is ok as written.

99 F 2 N S 100 F 2 N S Question was revised after validation.

B= F= 36 E=

RO TOTALS: M= H= 39 U= Additional Notes:

N=

B= F= E=

SRO TOTALS: M= H= U= Additional Notes:

N=

GENERAL COMMENT

S:

1. Bank questions are indicated by B; Modified are indicated by M; New questions are indicated by N.
2. Chief Examiner comments are indicated in blue.
3. Average difficulty is __ ___ on the RO exam and ___ on the SRO exam.
4. The 10CFR55.41/43 distribution is: RO / SRO 41.1 = 43.1 =

41.2 = 43.2 =

41.3 = 43.3 =

41.4 = 43.4 =

41.5 = 43.5 =

41.6 = 43.6 =

41.7 = 43.7 =

41.8 =

41.9 =

41.10 =

41.11 =

41.12 =

41.13 =

41.14 = Page 7 of 8 OBDI 202 - IOLE Process

ES-401 GG-2009-03 8 Form ES-401-9

5. The answer distribution is: RO / SRO A = 13 (17%) / 6 (24%)

B = 16 (22%) / 7 (28%)

C = 21 (28%) / 5 (20%)

D = 25 (33%) / 7 (28%)

6. There are questions with attachments provided. Page 8 of 8 OBDI 202 - IOLE Process