ML090540143

From kanterella
Jump to navigation Jump to search
SFP Crack Data
ML090540143
Person / Time
Site: Indian Point  Entergy icon.png
Issue date: 09/07/2005
From:
- No Known Affiliation
To:
NRC Region 1
References
Download: ML090540143 (2)


Text

p.

Date 09/07/05 09/07/05 09/07/05 09/07/05 09/07/05 Sample of Hole Drilled in North FSB Wall (1) Base line (2) First 2" (0-2") of crack (3) Second 2" (2-4") of crack (4) Third 2" (4-6") of crack (5) Fourth 2" (6-8") of crack Detph of Hole in Wall 2

2 4

6 8

2_H 11.74 10.7 11.46 11.75 11.79 Co-60 uCi/.qm Cs-134uCi/gm ND ND 8.31 E-05 2.65E-05 4.04E-05 1.39E-05 1.02E-05 ND ND ND

Cs-137 uCi/gm ND 1.65E-03 8.46E-04 1.27E-04 1.75E-05 Iron ppm leachate 96 628 640 3285 60 Boron ppm leachate 159 72 56 28 226 r-"