ML083300095
| ML083300095 | |
| Person / Time | |
|---|---|
| Site: | Limerick |
| Issue date: | 11/24/2008 |
| From: | David Helker Exelon Corp, Exelon Generation Co, Exelon Nuclear |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| Download: ML083300095 (10) | |
Text
Exelon Nuclear 200 Exelon Way Kennett Square, PA 19348 November 24, 2008 www.exeloncorp.com Nuclear 10CFR50.46 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001 Limerick Generating Station, Units 1 and 2 Facility Operating License Nos. NPF-39 and NPF-85 NRC Docket Nos. 50-352 and 50-353 Subject
Reference:
10 CFR 50.46 Annual Report 1)
Letter from David P. Helker (Exelon Generation Company, LLC) to U. S. Nuclear Regulatory Commission, "10 CFR 50.46 Annual Report," dated November 30, 2007 The purpose of this letter is to submit the 10 CFR 50.46 reporting information for Limerick Generating Station (LGS), Units 1 and 2. The most recent annual 50.46 Report for Limerick Generating Station (LGS), Units 1 and 2 (Reference 1) provided the cumulative Peak Cladding Temperature (PCT) errors for the most recent fuel designs through November 30, 2007.
Since the Reference 1 report was issued, no vendor notifications of Emergency Core Cooling System (ECCS) model error/changes that are applicable to LGS, Units 1 and 2 have been issued. Also, no ECCS-related changes or modifications have occurred at LGS, Units 1 and 2 that affect the assumptions of the ECCS system.
Two attachments are included with this letter that provide the current Limerick Generating Station, Units 1 and 2, 10 CFR 50.46 status. Attachments 1 and 2 ("Peak Cladding Temperature Rack-Up Sheef') provide updated information regarding the PCT for the limiting Loss of Coolant Accident (LOCA) analysis evaluations for LGS, Units 1 and 2, respectively. Attachment 3, "Assessment Notes,"
contains a detailed description for each change or error reported.
If you have any questions, please contact Tom Loomis at 610-765-5510.
Respectfully, David P. Helker Manager, Licensing & Regulatory Affairs Exelon Generation Company, LLC Attachments:
1)
Peak Cladding Temperature Rack-Up Sheet (Limerick Generating Station, Unit 1) 2)
Peak Cladding Temperature Rack-Up Sheet (Limerick Generating Station, Unit 2) 3)
Assessment Notes (Limerick Generating Station, Units 1 and 2) cc:
S. J. Collins, USNRC Administrator, Region I P. Bamford, USNRC Project Manager, LGS E. M. DiPaolo, USNRC Senior Resident Inspector, LGS
ATTACHMENT 1 10 CFR 50.46 "Acceptance criteria for emergency core cooling systems for light-water nuclear power reactors" Report of the Emergency Core Cooling System Evaluation Model Changes and Errors Assessments as of November 24, 2008 Peak Cladding Temperature Rack-Up Sheet Limerick Generating Station, Unit 1
Report of the Emergency Core Cooling System Evaluation Model Changes and Errors Assessments as of November 24,2008 Peak Cladding Temperature Rack-Up Sheet, LGS U1 Page 1 of 2 PLANT NAME:
ECCS EVALUATION MODEL:
REPORT REVISION DATE:
CURRENT OPERATING CYCLE:
ANALYSIS OF RECORD Evaluation Model:
Limerick Unit 1 SAFER/GESTR-LOCA 11/24/08 13 1.
NEDC-23785-1-PA Rev. 1, "The GESTR-LOCA and SAFER Models for the Evaluation of the Loss-Of-Coolant Accident Volume II, SAFER - Long Term Inventory Model for BWR Loss-Of-Coolant Analysis," October 1984.
2.
NEDC-30996P-A, "SAFER Model for Evaluation of Loss-of-Coolant Accidents for Jet Pump and Non-jet Pump Plants, Volume I, SAFER - Long Term Inventory Model for BWR Loss-of-Coolant Analysis," October 1987.
3.
NEDC-32950P, "Compilation of Improvements to GENE's SAFER ECCS-LOCA Evaluation Model," January 2000.
4.
NEDC-23785-1-PA Rev. 1, "The GESTR-LOCA and SAFER Models for the Evaluation of the Loss-Of-Coolant Accident Volume III, SAFER/GESTR Application Methodology,"
October 1984.
(Jet Pump Plant - SAFER)
Calculations:
1.
"Limerick Generating Station, Units 1 and 2 SAFER/GESTR-LOCA Loss-of-Coolant Accident Analysis," NEDC-32170P, May 1995.
2.
"Limerick Generating Station Units 1 and 2 ECCS-LOCA Evaluation for GE14," GE-NE-J1103793-09-01 P, March 2001.
3.
Letter from C. P. Bott to R. M. Butrovich, "Limerick Units 1 and 2 SAFERIGESTR Analysis with GE13 Fuel," July 20, 1995.
Fuel Analyzed in Calculations: P8x8R, GE9, GE11/13 and GE14 Limiting Fuel Type: GE14 (note: P8x8R, GE9 and GE11/13 are no longer in operation and are not considered for defining the limiting fuel type)
Limiting Single Failure: Div 2 DC Power Source Limiting Break Size and Location: Double-Ended Guillotine in a Recirculation Suction Pipe Reference Peak Cladding Temperature (PCT) - GE14 PCT =1670°F
Report of the Emergency Core Cooling System Evaluation Model Changes and Errors Assessments as of November 24,2008 Peak Cladding Temperature Rack-Up Sheet, LGS U1 MARGIN ALLOCATION A.
PRIOR LOCA MODEL ASSESSMENTS Page 2 of 2 10 CFR 50.46 Report dated December 18, 2002 (See Note 1)
GE14 ~PCT = 10°F 10 CFR 50.46 Report dated December 16, 2003 (See Note 2)
GE14 ~PCT = -5°F 10 CFR 50.46 Report dated December 03, 2004 (See Note 3)
GE14 ~PCT =
O°F 10 CFR 50.46 Report dated December 01, 2005 (See Note 4)
GE14 ~PCT = O°F 10 CFR 50.46 Report dated December 01, 2006 (See Note 5)
GE14 ~PCT = QOF 10 CFR 50.46 Report dated November 30, 2007 (See Note 6)
GE14 ~PCT = QOF Net PCT (GE14) 1675 of B.
CURRENT LOCA MODEL ASSESSMENTS None - (See Note 7)
Total PCT change from current assessments (GE14)
L~PCT =O°F Cumulative PCT change from current assessments (GE14)
L I~PCTI =O°F Net PCT (GE14) 1675 of
ATTACHMENT 2 10 CFR 50.46 "Acceptance criteria for emergency core cooling systems for light-water nuclear power reactors" Report of the Emergency Core Cooling System Evaluation Model Changes and Errors Assessments as of November 24, 2008 Peak Cladding Temperature Rack-Up Sheet Limerick Generating Station, Unit 2
Report of the Emergency Core Cooling System Evaluation Model Changes and Errors Assessments as of November 24,2008 Peak Cladding Temperature Rack-Up Sheet, LGS U2 Page 1 of 2 PLANT NAME:
ECCS EVALUATION MODEL:
REPORT REVISION DATE:
CURRENT OPERATING CYCLE:
ANALVSIS OF RECORD Evaluation Model:
Limerick Unit 2 SAFERIGESTR-LOCA 11/24/08 10 1.
NEDC-23785-1-PA Rev. 1, "The GESTR-LOCA and SAFER Models for the Evaluation of the Loss-Of-Coolant Accident Volume II, SAFER - Long Term Inventory Model for BWR Loss-Of-Coolant Analysis," October 1984.
2.
NEDC-30996P-A, "SAFER Model for Evaluation of Loss-of-Coolant Accidents for Jet Pump and Non-jet Pump Plants, Volume I, SAFER - Long Term Inventory Model for BWR Loss-of-Coolant Analysis," October 1987.
3.
NEDC-32950P, "Compilation of Improvements to GENE's SAFER ECCS-LOCA Evaluation Model," January 2000.
4.
NEDC-23785-1-PA Rev. 1, "The GESTR-LOCA and SAFER Models for the Evaluation of the Loss-Of-Coolant Accident Volume III, SAFERIGESTR Application Methodology,"
October 1984.
(Jet Pump Plant - SAFER)
Calculations:
1.
"Limerick Generating Station, Units 1 and 2 SAFERIGESTR-LOCA Loss-of-Coolant Accident Analysis," NEDC-32170P, May 1995.
2.
"Limerick Generating Station Units 1 and 2 ECCS-LOCA Evaluation for GE14," GE-NE-J1103793-09-01 P, March 2001.
3.
Letter from C. P. Bott to R. M. Butrovich, "Limerick Units 1 and 2 SAFERIGESTR Analysis with GE13 Fuel," July 20, 1995.
Fuel Analyzed in Calculations: P8x8R, GE9, GE11/13 and GE14 Limiting Fuel Type: GE14 (note: P8x8R, GE9 and GE11/13 are no longer in operation and are not considered for defining the limiting fuel type)
Limiting Single Failure: Div 2 DC Power Source Limiting Break Size and Location: Double-Ended Guillotine in a Recirculation Suction Pipe Reference Peak Cladding Temperature (PCT) - GE14 PCT =1670°F
Report of the Emergency Core Cooling System Evaluation Model Changes and Errors Assessments as of November 24,2008 Peak Cladding Temperature Rack-Up Sheet, LGS U2 MARGIN ALLOCATION A.
PRIOR LOCA MODEL ASSESSMENTS Page 2 of 2 10 CFR 50.46 Report dated December 18, 2002 (See Note 1)
GE14 L\\PCT =10°F 10 CFR 50.46 Report dated December 16, 2003 (See Note 2)
GE14 L\\PCT = -5°F 10 CFR 50.46 Report dated December 03, 2004 (See Note 3)
GE14 L\\PCT = OaF 10 CFR 50.46 Report dated December 01, 2005 (See Note 4)
GE14 L\\PCT = OaF 10 CFR 50.46 Report dated December 01, 2006 (See Note 5)
GE14 L\\PCT = OaF 10 CFR 50.46 Report dated November 30, 2007 (See Note 6)
GE14 L\\PCT = OaF Net PCT (GE14) 1675 of B.
CURRENT LOCA MODEL ASSESSMENTS None - (See Note 7)
Total PCT change from current assessments (GE14)
LilPCT = OaF Cumulative PCT change from current assessments (GE14)
L IilPCTI = OaF Net PCT (GE141 1675 of 10 CFR 50.46 "Acceptance criteria for emergency core cooling systems for light-water nuclear power reactors" Report of the Emergency Core Cooling System Evaluation Model Changes and Errors Assessment Notes Limerick Generating Station, Units 1 and 2
Report of the Emergency Core Cooling System Evaluation Model Changes and Errors Assessments as of November 24,2008 Assessement Notes LGS U1 and U2 1.
Prior LOCA Assessment Page 1 of 2 The referenced letter provided an annual 50.46 report for Units 1 and 2. This letter reported GE LOCA errors related to a SAFER core spray sparger elevation error and a SAFER bulk water level error. The PCT impact for the new errors was determined to be 15°F and -5°F, respectively, for GE14 fuel. The total PCT impact of these errors was determined to be 10°F for GE14 fuel.
[
Reference:
Letter from Michael P. Gallagher (Exelon Generation Company, LLC) to U. S.
NRC, "10 CFR 50.46 Reporting Requirements," dated December 18, 2002.]
2.
Prior LOCA Assessment The referenced letter provided an annual 50.46 report for Units 1 and 2. This letter reported a GE LOCA error related to a SAFER LevelNolume Table error. The PCT impact for the new error was determined to be -5°F for GE14 fuel.
[
Reference:
Letter from Michael P. Gallagher (Exelon Generation Company, LLC) to U. S.
NRC, "10 CFR 50.46 Reporting Requirements," dated December 16, 2003.]
3.
Prior LOCA Assessment The referenced letter provided an annual 50.46 report for Units 1 and 2. This letter reported GE LOCA errors related toa GESTR file interpolation error, a SAFER computer platform change, a WEVOL S1 volume error, a SAFER separator pressure drop error and a new heat source. The PCT impact for the new errors was determined to be OaF for each error. The total PCT impact of these errors on GE14 fuel was determined to be OaF.
[
Reference:
Letter from Michael P. Gallagher (Exelon Generation Company, LLC) to U. S.
Nuclear Regulatory Commission, "10 CFR 50.46 Annual Report," dated December 03, 2004.]
4.
Prior LOCA Assessment The referenced letter provided an annual 50.46 report for Units 1 and 2. There were no errors reported for the 2005 reporting period.
[
Reference:
Letter from Pamela B. Cowan (Exelon Generation Company, LLC) to U. S. Nuclear Regulatory Commission, "10 CFR 50.46 Annual Report," dated December 01, 2005.]
5.
Prior LOCA Assessment The referenced letter provided an annual 50.46 report for Units 1 and 2. This letter reported a newly discovered sensitivity to the assumed axial power shape for small break LOCA cases.
This sensitivity may result in higher calculated PCT values for top-peaked axial power shapes.
Due to this sensitivity, the calculated small break PCT for Limerick was higher than the previously calculated value. However, the Licensing Basis PCT (based on large break) remained the same. Therefore the licensing Basis PCT impact of the new power shape sensitivity was determined to be OaF for GE14 fuel.
Report of the Emergency Core Cooling System Evaluation Model Changes and Errors Assessments as of November 24,2008 Assessement Notes LGS U1 and U2 Page 2 of 2
[
Reference:
Letter from David P. Helker (Exelon Generation Company, LLC) to U. S. Nuclear Regulatory Commission, "10 CFR 50.46 Annual Report," dated December 01, 2006.]
6.
Prior LOCA Assessment The referenced letter provided an annual 50.46 report for Units 1 and 2. There were no errors reported for the 2007 reporting period.
[
Reference:
Letter from David P. Helker (Exelon Generation Company, LLC) to U. S. Nuclear Regulatory Commission, "10 CFR 50.46 Annual Report," dated November 30, 2007.]
7.
Current LOCA Assessment There are no vendor 50.46 notifications reported for Limerick since the last annual 50.46 letter dated November 30, 2007.