UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 December 2, 2008 Mr. David J. Bannister Vice President and CNO Omaha Public Power District Fort Calhoun Station FC-2-4 Post Office Box 550 Fort Calhoun, NE 68023-0550
SUBJECT:
FORT CALHOUN STATION, UNIT NO.1 - CORRECTION TO AMENDMENT NO. 255 RE: MODIFICATION OF CONTAINMENT SPRAY ACTUATION LOGIC AND DAMPERS IN CONTAINMENT AIR COOLING AND FILTERING SYSTEM (TAC NOS. MD6204 AND MD7043) AND AMENDMENT NO. 257 RE:
CONTROL ROOM ENVELOPE HABITABILITY (TAC NO. MD5577)
Dear Mr. Bannister:
On May 2,2008, and June 30, 2008, the U.S. Nuclear Regulatory Commission (NRC) issued Amendment Nos. 255 and 257, respectively, to Facility Operating License NO.DPR-40 for the Fort Calhoun Station (FCS), Unit No.1. Amendment No. 255 consisted of changes to the facility operating license and the Technical Specifications (TSs) in response to your applications dated July 30 and October 19, 2007, as supplemented by letters dated August 31 and December 12, 2007, and February 21, March 28, and April 4 and 10,2008. Amendment No. 257 consisted of changes to the facility operating license and TSs in response to your application dated May 16, 2007.
Amendment 255 revised TS Limiting Condition for Operation (LCO) 2.4, "Containment Cooling,"
LCO 2.14, "Engineered Safety Features System Initiation Instrumentation Settings," and LCO 2.15, "Instrumentation and Control Systems"; TS Surveillance Requirement (SR) 3.1 "Instrumentation and Control," SR 3.5(4), "Containment Isolation Valves Leak Rate Tests (Type C Tests)," and SR 3.6(3), "Containment Recirculating Air Cooling and Filtering System";
and associated TS Basis documents and Updated Safety Analysis Report sections to modify the containment spray system actuation logic to preclude automatic start of the containment spray pumps for a toss-of-coolant accident. This amendment also revised TS SR 3.6(3)a. to delete SRs for testing of the containment air cooling and filtering system (CACFS) emergency mode dampers and replace it with a surveillance to verify that the dampers are in the accident positions in all operating plant modes and deletes the requirement in TS SR 3.6(3)b. to remotely operate dampers.
Amendment 255 also added license conditions related to the replacement and testing of containment air cleaning and filtering (CACF) unit HEPA (high-efficiency particulate air) filters and surveillance testing of the CACF unit relief ports. The license conditions require administrative controls pending the completion of detailed analysis and confirm commitments for the licensee to submit TS amendments by October 31,2008.
Due to an administrative error, the issued revised TS 2.15 - Page 12 of the TSs inadvertently relocated "(f)" from the "Test, Maintenance and Inoperable BYPASS" column to the "Permissible
D. Bannister
- 2 Bypass Condition" column for the Pressurizer Low/Low Pressure functional unit. This error did not impact Amendment No. 255 for FCS and does not change the NRC staff's conclusions regarding Amendment No. 255 for FCS. Enclosed is a corrected version of TS 2.15 - Page 12.
Please discard the associated page from the previous amendment and replace it with the enclosed page.
Amendment 257 revised the TS requirements related to the control room envelope habitability in accordance with TS Task Force (TSTF) Traveler TSTF-448-A, Revision 3, "Control Room Habitability." The amendment also added a license condition regarding initial performance of new surveillance and assessment requirements. The TS improvement was published in the Federal Register on January 17, 2007 (72 FR 2022), as part of the consolidated line item improvement process.
Due to an administrative error, the issued revised TS 2.8 - Page 13 of the TSs inadvertently omitted the period under "Objective." This error did not impact Amendment No. 257 for FCS and the omission does not change the NRC staff's conclusions regarding Amendment No. 257 for FCS. Enclosed is a corrected version of TS 2.8 - Page 13. Please discard the associated page from the previous amendment and replace it with the enclosed page.
If you have any questions, please call me at 301-415-1445.
Sincerely,
~
1\\
,\\
OJ~'k ",'0 wvuy Alan B. Wang, Pr~ect Manager Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-285
Enclosure:
As stated cc w/encl: Distribution via Listserv
ENCLOSURES CORRECTED PAGE 2.15 - PAGE 12 FOR AMENDMENT NO. 255 OMAHA PUBLIC POWER DISTRICT FORT CALHOUN STATION, UNIT NO.1 AND CORRECTED PAGE 2.8 - PAGE 13 FOR AMENDMENT 257 FACILITY OPERATING LICENSE NO. DPR-40 DOCKET NO. 50-285
TECHNICAL SPECIFICATIONS TABLE 2-4 Instrument Operating Conditions for Isolation Functions
- Test, Minimum Minimum Permissible Maintenance Functional Operable Degree of Bypass and Inoperable No.
Unit Channels Redundancy Condition Bypass Containment Isolation A
Manual 1
None None N/A B
Containment High Pressure 2(a)(e)(g)
Logic Subsystem A During Leak (f) 2(a)(e)(g)
Logic Subsystem B Test C
Pressurizer Low/Low Pressure 2(a)(e)(g)
Logic Subsystem A Reactor Coolant (f) 2(a)(e)(g)
Logic Subsystem B Pressure Less Than 1700 psia(b) 2 Steam Generator Isolation A
Manual None None N/A B
Steam Generator Isolation None None N/A (i) Steam Generator Low Pressure Logic Subsystem A 2/Steam 1/Steam Steam Generator (f)
Gen(a)(e)(g)
Gen Pressure Less Than 600 psia(c)
Logic Subsystem B 2/Steam 1/Steam Gen(a)(e)(g)
Gen (ii) Containment High Pressure Logic Subsystem A 2(a)(e)(g)
During Leak (f)
Logic Subsystem B 2(a)(e)(g)
Test 3
Ventilation Isolation A
Manual None None N/A B
Containment High Radiation Logic Subsystem A 1(d)(g)
None If Containment (f)
Logic Subsystem B 1(d)(g)
None Relief and Purge Valves are Closed a
Circuits on ESF Logic Subsystems A and B each have 4 channels.
b Auto removal of bypass prior to exceeding 1700 psia.
c Auto removal of bypass prior to exceeding 600 psia.
2..15 - Page 12 Amendment No. 88,93,108,152,153,173,184,194,249, 255
TECHNICAL SPECIFICATIONS 2.0 LIMITING CONDITIONS FOR OPERATION 2.8 Refueling 2.8.3 Refueling Operations - Spent Fuel Pool 2.8.3(5)
Control Room Ventilation System (CRVS)
Applicability Applies to operation of the CRVS during REFUELING OPERATIONS in the spent fuel pool area. The provisions of Specification 2.0.1 for Limiting Conditions for Operation are not applicable.
Objective To minimize the consequences of a fuel handling accident to the control room staff.
Specification (1)
The CRVS shall be IN OPERATION and in the Filtered Air mode.
(2)
A spent fuel pool area radiation monitor shall be IN OPERATION.
*-------Notes-------------------------------------------------------
- 1. The control room envelope (CRE) may be opened intermittently under administrative control.
- 2. Place in toxic gas protection mode immediately if automatic transfer to toxic gas protection mode is not functional.
Required Actions (1)
If a CRVS train is not IN OPERATION in Filtered Air mode, immediately place the opposite train IN OPERATION in Filtered Air mode OR immediately suspend REFUELING OPERATIONS.
(2)
If a spent fuel pool area radiation monitor is not IN OPERATION, immediately suspend REFUELING OPERATIONS.
(3)
If one or more CRVS trains are inoperable due to an inoperable control room envelope (CRE) boundary, immediately suspend REFUELING OPERATIONS.
2.8-Page13 Amendment No. 188, 201, 257
December 2, 2008 D. Bannister
- 2 Bypass Condition" column for the Pressurizer Low/Low Pressure functional unit. This error did not impact Amendment No. 255 for FCS and does not change the NRC staff's conclusions regarding Amendment No. 255 for FCS. Enclosed is a corrected version of TS 2.15 - Page 12.
Please discard the associated page from the previous amendment and replace it with the enclosed page.
Amendment 257 revised the TS requirements related to the control room envelope habitability in accordance with TS Task Force (TSTF) Traveler TSTF-448-A, Revision 3, "Control Room Habitability." The amendment also added a license condition regarding initial performance of new surveillance and assessment requirements. The TS improvement was published in the Federal Register on January 17, 2007 (72 FR 2022), as part of the consolidated line item improvement process.
Due to an administrative error, the issued revised TS 2.8 - Page 13 of the TSs inadvertently omitted the period under "Objective." This error did not impact Amendment No. 257 for FCS and the omission does not change the NRC staff's conclusions regarding Amendment No. 257 for FCS. Enclosed is a corrected version of TS 2.8 - Page 13. Please discard the associated page from the previous amendment and replace it with the enclosed page.
If you have any questions, please call me at 301-415-1445.
Sincerely, IRAI Alan B. Wang, Project Manager Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-285
Enclosure:
As stated cc w/encl: Distribution via Listserv DISTRIBUTION PUBLIC RidsNrrDraAadb Resource LPLIV Reading RidsNrrDssScvb Resource RidsAcrsAcnw_MailCTR Resource RidsNrrDssSsib Resource RidsNrrDeEicb Resource RidsNrrPMFortCalhoun Resource RidsNrrDirsltsb Resource RidsNrrLAJBurkhardt Resource RidsNrrDorlDpr Resource RidsOgcRp Resource RidsNrrDorlLpl4 Resource RidsRgn4MailCenter Resource ADAM5Accesslon NO. ML083240769