ML083230049
| ML083230049 | |
| Person / Time | |
|---|---|
| Site: | San Onofre |
| Issue date: | 11/11/2008 |
| From: | Gershkoff A Southern California Edison Co |
| To: | Office of Nuclear Reactor Regulation |
| References | |
| Download: ML083230049 (33) | |
Text
ENCLOSURE SAN ONOFRE NUCLEAR GENERATING STATION (SONGS)
SONGS-2 CYCLE 15 STARTUP TEST ACTIVITY REDUCTION (STAR) PROGRAM IMPLEMENTATION
SUMMARY
REPORT Performed By Reviewed By Approved By A. Gershkoff
/
Reactor Engineer D. Powers Reactor Engineering Supervisor STomsen Manager, Nuclear Fuels Management Date:/1 2
Date:
Date: /1/)/9
SONGS-2 Cycle 15 Summary Report Page 2 of 33 SONGS-2 CYCLE 15 STAR IMPLEMENTATION
SUMMARY
REPORT Introduction Southern California Edison first applied the Startup Test Activity Reduction (STAR) Program methodology to San Onofre Nuclear Generating Station (SONGS) Unit 2 Cycle 15, which allowed the elimination of Control Element Assembly (CEA) group worth measurements from the Low Power Physics Test (LPPT) Program.
SONGS Technical Specification Surveillance Requirement (SR) 3.1.4.1, "Verify MTC [Moderator Temperature Coefficient] within the upper limit, [prior to entering Mode 1 after each fuel loading]," was not changed prior to SONGS-2 Cycle 15 initial criticality; therefore, SR 3.1.4.1 was performed consistent with previous cycles, as allowed by Reference 1.
The SONGS-2 Cycle 15 STAR Implementation Summary Report includes information as required from Condition/Limitation #3 of the NRC safety evaluation of Reference 1, which states, "The staff requires each licensee using STAR to submit a summary report following the first application, either successful or not, of STAR to its plant.
The report should (a) identify the core design method used, (b) compare the measured and calculated values and the differences between these values to the corresponding core design method uncertainties and (c) show compliance with the STAR applicability requirements. If the application of STAR is
,unsuccessful, identify the reasons why the STAR application failed."
Core Design Method The Westinghouse ROCS computer program and Studsvik SIMULATE-3 (SIM-3) computer program were used for the core design and startup test predictions of SONGS-2 Cycle 15, consistent with Reference 2.
STAR Test Results and Associated Uncertainties Table 1, "STAR Test Results and Uncertainties," provides results from the SONGS-2 Cycle 15 LPPT Program, consistent with the list of STAR program tests provided in Table 3-3 of Reference 1. All of the measured values
.were within test acceptance criteria. Differences between measured and predicted (calculated) parameters compared favorably with the core design method uncertainties.
SONGS-2 Cycle 15 Summary Report Page 3 of 33 STAR Applicability Requirements Reference 1 Table 3-4, "STAR Program Applicability Requirements," lists the applicability requirements for use of the STAR program. The STAR applicability requirements involve the following 5 areas: 1) Core Design, 2) Fabrication (Fuel Assembly and Control Element Assembly (CEA)), 3) Refueling, 4) CEA Lifetime, and 5) Startup Testing. Prior to eliminating the CEA group worth measurements from the SONGS-2 Cycle 15 Low Power Physics Test program, all STAR applicability requirements were verified to be met.
Conformance with the Core Design applicability requirements is documented in Reference 3.
Conformance with the Fuel Fabrication applicability requirements is documented in Reference 4.
Conformance with the CEA Fabrication applicability requirements is documented in Reference 5.
Conformance with the Refueling applicability requirements (programmatically) is documented in Reference 3. Reference 6, as performed for SONGS-2 Cycle 15, documents verification of proper CEA coupling based on visual criteria consistent with Reference 1 Table 3-4:1) weight comparison of coupled vs. uncoupled CEA, 2) visual verification of "7-slot" pin position, 3) visual height comparison of CEA extension shafts, and 4) reweighing of coupled CEA extension shafts by an independent team. Reference 7, as performed for SONGS-2 Cycle 15, documents verification that the fuel assemblies, CEAs, and neutron sources are installed in the proper location and with the correct orientation.
Conformance with the CEA Lifetime applicability requirements is documented in References 8 and 9. The eighty-three full length CEAs used in the SONGS-2 Cycle 15 core are comprised of seventy-five new 5-finger CEAs, four re-used 5-finger CEAs that were new for Cycle 14, and four re-used 4-finger CEAs that were new for Cycle 13. At most, Cycle 15 represents a third cycle of operation for its constituent CEAs. Reference 8 concludes that these CEAs will be within the CEA lifetime requirements throughout Cycle 17 operation. Therefore, all of the full length CEAs utilized in SONGS-2 Cycle 15 are within established limits.
Conformance with the Startup Testing requirement of Critical Boron Concentration within 500 pcm of prediction is documented in Reference 10, as performed for SONGS-2 Cycle 15. Test results are provided in Attachment 1.
SONGS-2 Cycle 15 Summary Report Page 4 of 33 Summary The measured test results for all the required STAR tests in Table 3-3 of Reference 1 were within the test acceptance criteria; all test results compared favorably with the associated core design method uncertainties. Compliance with the STAR applicability requirements was demonstrated. Therefore, all of the requirements to implement STAR for SONGS-2 Cycle 15 were met. STAR was implemented successfully for SONGS-2 Cycle 15.
References
- 1. WCAP-1 6011-P-A, Revision 0, "Startup Test Activity Reduction Program,"
February 2005 (referred to in this report as STAR)
- 2. SCE-9801 -P-A, Reload Analysis Methodology for the San Onofre Nuclear Generating Station Units 2 and 3 [Reload Topical Report],
June 1999
- 3. Calculation NFM-2-PH-1519, SONGS-2 Cycle 15 STAR Core Design/Refueling Requirements, 11/9/2007
- 4. Memorandum For File, Fuel Assembly Fabrication Verification to Support WCAP-1 6011-P-A Rev. 0, STAR, Implementation at SONGS Unit 2 Cycle 15, 12/26/2007
- 5. Memorandum For File, STAR - CEA Fabrication Verification to Support WCAP-1 6011-P-A Rev. 0, Implementation at SONGS Unit 2 Cycle 15, 12/21/2007
- 6. Procedure S023-1-3.46, Remote Five Finger CEA Extension Shaft Coupling, Rev. 4 (EC 4-1), 9/24/2004
- 7. Procedure S023-X-7, Nuclear Fuel Movement for Refueling Cycles, Rev 14,
,3/30/2007
- 8. Calculation N-1 020-175, CEA Life Limit for Units 2 and 3 Cycles 15 through 17, 5/10/2007
- 9. Calculation NFM-2-PH-1520, SONGS-2 Cycle 15 Physics RAR Input, 8/3/2007
- 10. Procedure S023-XXXVII-1, Low Power Physics Testing, Rev. 5, 12/19/2007
SONGS-2 Cycle 15 Summary Report Page 5 of 33 ATTACHMENT 1 TEST RESULTS TABLE 1 STAR TEST RESULTS AND UNCERTAINTIES TEST POWER MEASURED CALCULATED DIFFERENCE TEST CRITERIA UNCERTAINTY VALUE VALUE Drop Time to Maximum CEA Drop Time Shutdown 90% Inserted:
N/A N/A Allowed:
N/A 3.01 sec avg, 3.4 sec avg, 3.17 sec max 3.6 sec max 21 (of 91) CEAs identified to be Procedure and couple checked with reactimeter; program CEA Drop time risticscouple check of reactuall conservatisms All CEAs verified N/A Car tiShutdown couple check of 32 CEAs actually dictated couple to be coupled performed with reactimeter; all CEAs checks of 32 verified to be coupled CEAs 50 ppm Critical Boron Hot Zero Power 2148 ppm 2140 ppm 8 ppm (procedural
+/-26 ppm Concentration (CBC)
(HZP)
(55 pcm) review),
500 pcm (STAR)
Moderator Temperature Coefficient (MTC)
HZP
+1.1 pcm/fF
+1.0 pcmiF
+0.1 pcmPF MTC < 5 pcm/°F
+/- 2.4 pcmifF Alternate Surveillance MTC, as measured HZP
+0.7 pcmfF
+1.1 pcmfF
-0.4 pcmPF MTC < 5 pcm/°F;
+/- 2.4 pcmF using Reactimeter HP+7pmF
+.pci-04m/
Diff < 3 pcm/°F Relative Power
+4.63% max Density (RPD)
Incore Fluxpoiie wihn+1%f Symmetry Low (20%)
See Table 2 See Table 2 positive; within +/- 10% ofN/A
-7.32% most prediction for fuel negative assemblies with RPD > 0.9
SONGS-2 Cycle 15 Summary Report Page 6 of 33 ATTACHMENT 1 TEST RESULTS TABLE 1 STAR TEST RESULTS AND UNCERTAINTIES TEST POWER MEASURED CALCULATED DIFFERENCE TEST CRITERIA UNCERTAINTY VALUE VALUE_______
@ 20% power:
@ 20% power:
@ 20% power:
See Table 2 See-Table 2 2.15% RMS
@ 80% power:
@ 80% power:
@ 80% power:
See Table 3 See Table 3 1.30% RMS
< 5% RMS N/A Incore Power Radial PD; Distribution See Table 4 See Table 4 4.56% RMS
< 5% RMS N/A Axial PD; Fq =1.69; Fq =1.72;
-1.7%;
<t10%
+/- 5.93%;
Fxy =1.47; Fxy =1.49;
-1.0%;
<+/-10%
+/- 5.46%;
Fr =1.44; Fr =1.46;
-1.4%
<+/-10%
+/- 4.24%;
Fz =1.17 Fz =1.19
-1.9%
<+/- 10%
N/A Isothermal Intermediate to Temperature Hot Full Power
-7.8 pcm0 F
-9.7pcm/PF
+1.9 pcm/F Diff < 3 pcm/fF
+/- 2.4 pcm/PF Coefficient (ITC)
(HFP)
-4.7 pcm/F
-4.3 pcm/PF
-0.4 pcm/PF
< -0.6 pcmiF
@ 70% power;
-7.4 pcm/F
-7.0 pcm/tF
-0.4 pcmfF
< -3.0 pcm/F
@ 100% power; Intermediate to
-36.3 pcm/F
-35.9 pcmPF
-0.4 pcm/fF
> -37 pcm/F MTC Surveillance HFP
@ EOC 100%
_ 2.4 pcm/F (from HZP test);
-34.0 pcm/fF
-35.9 pcm/fF
+1.9 pcm/PF
> -37 pcm/F
@ EOC 100%
(from 33 EFPD HFP test)
SONGS-2 Cycle 15 Summary Report Page 7 of 33 ATTACHMENT 1 TEST RESULTS TABLE 1 STAR TEST RESULTS AND UNCERTAINTIES TEST POWER MEASURED CALCULATED DIFFERENCE TEST CRITERIA UNCERTAINTY VALUE VALUE See Table 5 See Table 5 1.18% RMS
< 5% RMS N/A Radial PD; See Table 6 See Table 6 2.52% RMS
< 5% RMS N/A Incore Power HFP Axial PD; Distribution Fq = 1.68; Fq = 1.70;
-1.2%;
<+/- 10%
+/- 5.93%;
Fxy = 1.47; Fxy = 1.48;
-0.7%;
<+/- 10%
+/- 5.46%;
Fr =1.44; Fr =1.46;
-1.4%
< +/- 10%
+/- 4.24%;
Fz =1.16 Fz =1.18
-1.7%
<+/-10%
N/A A CBC HZP - HFP HFP 525 ppm 505 ppm
+20 ppm
+/- 75 ppm
+/- 26 ppm
SONGS-2 Cycle 15 Summary Report Page 8 of 33 ATTACHMENT 1 TEST RESULTS TABLE 2 20% RADIAL POWER DISTRIBUTION PREDICTED RELATIVE POWER DENSITIES 1
2 '
3 5
..4 0.393 10.796 0.795 0.393 Assy #
RPD r
r r
r r
1 T
T 5
6 7
0.222 0.535 0.886 8
1.083 9
0.953 10 1.082 11 0.886 12 0.535 13 0.222
+
4 4
+/-
1 4
4 23 24 14 0.307 15 16 0.798 0.993 17 1.202 18 1.176 19 1.309 20 1.175 21 1.20 1 22' 0.993 23 0.798 24 0.307 0.798 0.307
+
t 4
1 t
4-1 4
r 25 26 27 28 29 30 31 32 33 34 1.207 35 1.012 36 37 0.582 0.307 83 0.393
.100 0.795 117 0.796 134 0.393 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 0.222 0.798 1.012 0.942 1.103 1.33 1.174 1.367 1.173 1.329 1.102 0.942 1.012 0.798 0.222 53 54 55 56 57 58 59 60 61.
62 63 64 05 66 67 0.535 0.993 1.207 1.102 1.31 1.161 1.35 1.142 1.349 1.159 1.31 1.103 1.208 0.993 0.535 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 0.886 1.201 1.095 1.329 1.159 1.333 1.11 1.296 1.109 1.333 1.161 1.33 1.096 1.202 0.886 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 1.082 1.175 1.345 1.173 1.349 1.109 1.211 0.893 1.211 1.11 1.35 1.174 1.347 1.176 1.083 102 103 104 105 106 107.
108 109 110 il11 112 113 114 115 116 0.953 1.309 1.171 1.367 1.142 1.296 0.893 0.775 0.893 1.296 1.142 1.367 1.171 1.309 -0.953 119-~
120 121 122 123 124 125 126 127 128 129 130 131 132 133 1.083 1.176 1.347 1.174 1.35 1.11 1.211 0.893 1.211 1.109 1.349 1.173 1.345 1.175 1.082 136 137 138 139 140 141 142 143 144-145 146 147 148 149 150 0.886 1.202 1.096 1.33 1.161 1.333 1.109 1.296 1.11 1.333 1.159 1.329 1.095 1.201 0.886 151 152 153 154 155 156 157.
158' 159 160.
161 162 163 164 165 0.535 0.993 1.208 1.103 1.31 1.159 1.349 1.142 1.35 1.161 1.31 1.102 1.207 0.993 0.535 166.
167 168 169 170 171 172 173 174 175 176 177 178 179 180 0.222 0.798 1.012 0.942 1.102 1.329 1.173 1.367 1.174 1.3 1.103 0.942 1.012 0.798 0.222 84 0.393 101 0.796 118 0.795 135 0.393 181 0.307 182 0.582 183 184 1.012 1.207 185 1.095 186 1.345 187 1.171 188 1.347 189 1.096 190 1.208 191 1.012 192 193 0.582 0.307 194 0.307 195 196 079 0.993 197 1.20 1 198' 1.175 199 1.309 200 1.176 201 1.202 202 0.993 203 0.798 204 0.307 205 206 0.222 0.535 207 0.886 208 1.082 209 0.953 210 1.083 211 0.886 212 0.535 213 0.222 214 215 0216 0217 0.393 0.795 0.796 0.393
SONGS-2 Cycle 15 Summary Report Page 9 of 33 ATTACHMENT 1 TEST RESULTS TABLE 2 20% RADIAL POWER DISTRIBUTION MEASURED RELATIVE POWER DENSITIES 1
2 3
4 0.405 10.802 10.803 10.407 Assy #
RPD 5
0.215 6
0.548 7
0.9 13 8
1.089 9
0.958
-~10 1.094 11 0.923 12 0.559 13 0.231 182,22 14 0.325 15 0.823 16 1.024 17 1.2 18 1.182 19 1.296 20 1.189 21 1.215 22 1.039 23 0.837 24 0.329 1.182 1.189 1.039 0.329
+
4 1
+
t I
I t
25 26 0.313 0.614 27 1.044 28 1.209 29 30 1.078 1.318 31 1.176 32 1.324 33 1.096
.34 1.225 35 1.055 36 0.622 37 0.318 83 0.398 100 0.799 117 0.795 134 0.386 38 39 40 41 42 43 44 45 46 47 48 49 150 5 51 52 0.222 0.804 1.022 0.972 1.119 1.303 1.158 1.271 1.161 1.31 1.13 0.985. 1035 0.815 0.224 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 0.532 0.994 1.196 1.102 1.294 1.16 1.319 1.133 1.318 1.152 1.303 1.121 1.212 1.007 0.537 68 69 70 71 72 73 74 75
.76 77 78 79 80 81 82 0.875 1.19 1.1 1.307 1.162 1.315 1.116 1.275 1.116 1.315 1.168 1.319 1.112 1.202 0.879 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 1.082 1.192 1.322 1.165 1.323 1.118 1.199 0.886 1.198 1.121 1.326 1.168 1.334 1.205 1.087 102 103 104 105 16 107 108 109 110 il1 112 113 114 115 116 0.97 1.295 1.159 1.269 1.134 1.283 0.898 0.781 0.892 1.278 1.133 1.274 1.165 1.302 0.974 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 1.074 1.181 1.322 1.168 1.328 1.127 1.204 0.889 1.197 1.113 1.325 1.175 1.324 1.183 1.076 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 0.868 1.187 1.104 1.315 1.168 1.32 1.121 1.28 1.118 1.315 1.163 1.312 1.099 1.184 0.868 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 0.53 0.997 1.203 1.116 1.303 1.158 1.323 1.139 1.321 1.162 1.297 1.107 1.195 0.99 0.529 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 0.221 0.804 1.028 0.983 1.131 1.317 11.16 1.267 1.156 1.304 1.119 0.972 1.019 0.801 0.22 84 0.393 101 0.801 118 0.798 135 0.39 181 0.305 182 183 0.618 1.058 184 1.229 185 1.114 186 1.322 187 1.164 188 1.314 189 1.082 190 1.208 191 192 1.035 0.612 193 0.311 194 0.327
- 195, 0.831 196 1.03 1 197 1.2 198 1.177 199 1.285 200 1.182 201 1.2 202 1.024.
203 204 0.822 0.324 205 0.221 206 0.542 207 0.875 208 1.068 209 0.946 2101 211 1.081 0.908 212 0.549 213 0.224 214 215
ý 21 6
ý 217 0.394 0.788 0.793 0.402
SONGS-2 Cycle 15 Summary Report Page 10of 33 ATTACHMENT 1 TEST RESULTS TABLE 2 20% RADIAL POWER DISTRIBUTION ASSEMBLY MEASURED PREDICTED DIFFERENCE DIFF / PRED 1
0.405 0.393 0.012 0,0305 2
0.802 0.796 0.006 0.0075 3
0.803 0.795 0.008 0.01 01 4
0.407 0.393 0.014 0.0356 5
0.215 0.222
-0.007
-0.0315 6
0.548 0.535 0.013 0.0243 7
0.913 0.886 0.027 0.0305 8
1.089 1.083 0.006 0.0055 9
0.958 0.953 0.005 0.0052 10 1.094 1.082 0.012
.0.0111 11 0.923 0.886 0.037 0.0418 12 0.559 0.535 0.024 0.0449 13 0.231 0.222 0.009 0.0405 14 0.325 0.307 0.018 0.0586 15 0.823 0.798 0.025 0.0313 16 1.024 0.993 0.031 0.0312 17 1.2 1.202
-0.002
-0.0017 18 1.182 1.176 0.006 0.0051 19 1.296 1.309
-0.013
-0.0099 20 1.189 1.175 0.014 0.0119 21 1.215 1.201 0.014 0.0117 22 1.039 0.993 0.046 0.0463 23 0.837 0.798 0.039 0.0489 24 0.329 0.307 0.022 0.0717 25 0.31.3 0.307 0.006 0.0195 26 0.614 0.582 0.032 0.055 27 1.044 1.012 0.032 0.0316 28 1.209 1.208 0.001 0.0008 29 1.078 1.096
-0.018
-0.0164 30 1.318 1.347
-0.029
-0.0215 31 1.176 1.171 0.005 0.0043 32 1.324 1.345
-0.021
-0.0156 33 1.096 1.095 0.001 0.0009 34 1.225 1.207 0.018 0.0149 35 1.055 1.012 0.043 0.0425 36 0.622 0.582
. 0.04 0.0687 37 0.318 0.307 0.011 0.0358 38 0.222 0.222 0
0 39 0.804 0.798 0.006 0.0075 40 1.022 1.012 0.01 0.0099
SONGS-2 Cycle 15 Summary Report Page 11 of 33 ATTACHMENT 1 TEST RESULTS TABLE 2 20% RADIAL POWER DISTRIBUTION ASSEMBLY MEASURED PREDICTED DIFFERENCE DIFF / PRED 41 0.972 0.942 0.03 0.0318 42 1.119 1.103 0.016 0.0145 43 1.303 1.33
-0.027
-0.0203 44 1.158 1.174
-0.016
-0.0136 45 1.271 1.367
-0.096
-0.0702 46 1.161 1.173
-0.012
-0.0102 47 1.31 1.329
-0.019
-0.0143 48 1.13 1.102 0.028 0.0254 49 0.985 0.942 0.043 0.0456 50 1.035 1.012 0.023 0.0227 51 0.815 0.798 0.017 0.0213 52 0.224 0.222 0.002 0.009 53 0.532 0.535
-0.003
-0.0056 54 0.994 0.993 0.001 0.001 55 1.196 1.207
-0.011
-0.0091 56 1.102 1.102 0
0 57 1.294 1.31
-0.016
-0.0122 58 1.16 1.161
-0.001
-0.0009 59 1.319 1.35
-0.031
-0.023 60 1.133 1.142
-0.009
-0.0079 61 1.318 1.349
-0.031
-0.023 62 1.152 1.159
-0.007
-0.006 63 1.303 1.31
-0.007
-0.0053 64 1.121 1.103 0.018 0.0163 65 1.212 1.208 0.004 0.0033 66 1.007 0.993 0.014 0.0141 67 0.537 0.535 0.002 0.0037 68 0.875 0.886
-0.011
-0.0124 69 1.19 1.201
-0.011
-0.0092 70 1.1 1.095 0.005 0.0046 71 1.307 1.329
-0.022
-0.0166 72 1.162 1.159 0.003 0.0026 73 1.315 1.333
-0.018
-0.0135 74 1.116 1.11 0.006 0.0054 75 1.275 1.296
-0.021
-0.0162 76 1.116 1.109 0.007 0.0063 77 1.315 1.333
-0.018
-0.0135 78 1.168 1.161 0.007 0.006 79 1.319 1.33
-0.011
-0.0083 80 1.112 1.096 0.016 0.0146
SONGS-2 Cycle 15 Summary Report Page 12 of 33 ATTACHMENT 1 TEST RESULTS TABLE 2 20% RADIAL POWER DISTRIBUTION ASSEMBLY MEASURED PREDICTED DIFFERENCE DIFF / PRED 81 1.202 1.202 0
0 82 0.879 0.886
-0.007
-0.0079 83 0.398 0.393 0.005 0.0127 84 0.393 0.393 0
0 85 1.082 1.082 0
0 86 1.192 1.175 0.017 0.0145 87 1.322 1.345
-0.023
-0.0171 88 1.165 1.173
-0.008
-0.0068 89 1.323 1.349
-0.026
-0.0193 90 1.118 1.109 0.009 0.0081 91 1.199 1.211
-0.012
-0.0099 92 0.886 0.893
-0.007
-0.0078 93 1.198 1.211
-0.013
-0.0107 94 1.121 1.11 0.011 0.0099 95 1.326 1.35
-0.024
-0.0178 96 1.168 1.174
-0.006
-0.0051 97 1.334 1.347
-0.013
-0.0097 98 1.205 1.176 0.029 0.0247 99 1.087 1.083 0.004 0.0037 100 0.799 0.795 0.004 0.005 101 0.801 0.796 0.005.
0.0063 102 0.97 0.953 0.017 0.0178 103 1.295 1.309
-0.014
-0.0107 104 1.159 1.171
-0.012
-0.0102 105 1.269 1.367
-0.098
-0.0717 106 1.134 1.142
-0.008
-0.007 107 1.283 1.296
-0.013
-0.01 108 0.898 0.893 0.005 0.0056 109 0.781 0.775 0.006 0.0077 110 0.892 0.893
-0.001
-0.0011 111 1.278 1.296
-0.018
-0.0139 112 1.133 1.142
-0.009
-0.0079 113 1.274 1.367
-0.093
-0.068 114 1.165 1.171
-0.006
-0.0051 115 1.302 1.309
-0.007
-0.0053 116 0.974 0.953 0.021 0.022 117 0.795 0.796
-0.001
-0.0013 118 0.798 0.795 0.003 0.0038 119 1.074 1.083
-0.009
-0.0083 120 1.181 1.176 0.005 0.0043
SONGS-2 Cycle 15 Summary Report Page 13 of 33 ATTACHMENT 1 TEST RESULTS TABLE 2 POWER DISTRIBUTION ASSEMBLY 121 1,22 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 20% RADIAL MEASURED 1.322 1.168 1.328 1.127 1.204 0.889 1.197 1.113 1.325 1.175 1.324 1.183 1.076 0.386 0.39 0.868 1.187 1.104 1.315 1.168 1.32 1.121 1.28 1.118 1.315 1.163 1.312 1.099 1.184 0.868 0.53 0.997 1.203 1.116 1.303 1.158 1.323 1.139 1.321 1.162 PREDICTED 1.347 1.174 1.35 1.11 1.211 0.893 1.211 1.109 1.349 1.173 1.345 1.175 1.082 0.393 0.393 0.886 1.202 1.096 1.33 1.161 1.333 1.109 1.296 1.11 1.333 1.159 1.329 1.095 1.201 0.886 0.535 0.993 1.208 1.103 1.31 1.159 1.349 1.142 1.35 1.161 DIFFERENCE
-0.025
-0.006
-0.022 0.017
-0.007
-0.004
-0.014 0.004
-0.024 0.002
-0.021 0.008
-0.006
-0.007
-0.003
-0.018
-0.015 0.008
-0.015 0.007
-0.013 0.012
-0.016 0.008
-0.018 0.004
-0.017 0.004
-0.017
-0.018
-0.005 0.004.
-0.005 0.013
-0.007
-0.001
-0.026
-0.003
-0.029 0.001 DIFF / PRED
-0.0186
-0.0051
-0.0163 0.0153
-0.0058
-0.0045
-0.0116 0.0036
-0.0178 0.0017
-0.0156 0.0068
-0.0055
-0.0178
-0.0076
-0.0203
-0.0125 0.0073
-0.0113 0.006
-0.0098 0.0108
-0.0123 0.0072
-0.0135 0.0035
-0.0128 0.0037
-0.0142
-0.0203
-0.0093 0.004
-0.0041 0.0118
-0.0053
-0.0009
-0.0193
-0.0026
-0.0215 0.0009
SONGS-2 Cycle 15 Summary Report Page 14 of 33 ATTACHMENT 1 TEST RESULTS TABLE 2 20% RADIAL POWER DISTRIBUTION ASSEMBLY MEASURED PREDICTED DIFFERENCE DIFF /PRED 161 1.297 1.31
-0.013
-0.0099 162 1.107 1.102 0.005 0.0045 163 1.195 1.207
-0.012
-0.0099 164 0.99 0.993
-0.003
-0.003 165 0.529 0.535
-0.006
-0.0112 166 0.221 0.222
-0.001
-0.0045 167 0.804 0.798 0.006 0.0075 168
.1.028 1.012 0.016 0.0158 169 0.983 0.942 0.041 0.0435 170 1.131 1.102 0.029 0.0263 171 1.317 1.329
-0.012
-0.009 172 1.16 1.173
-0.01.3
-0.0111 173 1.267 1.367
-0.1
-0.0732 174 1.156 1.174
-0.018
-0.0153 175 1.304 1.33
-0.026
-0.0195 176 1.119 1.103 0.016 0.0145 177 0.972 0.942 0.03 0.0318 178 1.019 1.012 0.007 0.0069 179 0.801 0.798 0.003 0.0038 180 0.22 0.222
-0.002
-0.009 181 0.305 0.307
-0.002
-0.0065 182 0.618 0.582 0.036 0.0619 183 1.058 1.012 0.046 0.0455 184 1.229 1.207 0.022 0.0182 185 1.114 1.095 0.019 0.0174 186 1.322 1.345
-0.023
-0.0171 187 1.164 1.171
-0.007
-0.006 188 1.314 1.347
-0.033
-0.0245 189 1.082 1.096
-0.014
-0.0128 190 1.208 1.208 0
0 191 1.035 1.012 0.023 0.0227 192 0.612 0.582 0.03 0.0515 193 0.311 0.307 0.004 0.013 194 0.327 0.307 0.02 0.0651 195 0.831 0.798 0.033 0.0414 196 1.031 0.993 0.038 0.0383 197 1.2 1.201
-0.001
-0.0008 198 1.177 1.175 0.002 0.0017 199 1.285 1.309
-0.024
-0.0183 200 1.182 1.176 0.006 0.0051
SONGS-2 Cycle 15 Summary Report Page 15 of 33 ATTACHMENT 1 TEST RESULTS TABLE 2 20% RADIAL POWER DISTRIBUTION ASSEMBLY 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 MEASURED 1.2 1.024 0.822 0.324 0.221 0.542 0.875 1.068 0.946 1.081 0.908 0.549 0.224 0.394 0.788 0.793 0.402 PREDICTED 1.202 0.993 0.798 0.307 0.222 0.535 0.886 1.082 0.953 1.083 0.886 0.535 0.222 0.393 0.795 0.796 0.393 DIFFERENCE
-0.002 0.031 0.024 0.017
-0.001 0.007
-0.011
-0.014
-0.007
-0.002 0.022 0.014 0.002 0.001
-0.007
-0.003 0.009 DIFF / PRED
-0.0017 0.0312 0.0301 0.0554
-0.0045 0.0131
-0.0124
-0.0129
-0.0073
-0.0018 0.0248 0.0262 0.009 0.0025
-0.0088
-0.0038 0.0229 SUM OF THE SQUARES OF THE DIFFERENCES =
RMS ERROR =.0215
.1002 ALL BUNDLE POWERS MEET THE ACCEPTANCE CRITERIA
SONGS-2 Cycle 15 Summary Report Page 16 of 33 ATTACHMENT 1 TEST RESULTS TABLE 3 80% RADIAL POWER DISTRIBUTION PREDICTED RELATIVE POWER DENSITIES 0.395 2
3 4
0.800 0.800 0.394 Assy #
RPD 5
0.220 6
0.535 7
0.880 8
1.088 9
0.970 10 1.086 11 0.880 12 0.535 13 0.220 14 0.317 15 0.81 16 1.020 17 1.205 18 1.192 19 1.307 20 1.190 21 1.204 22 1.020 23 0.817 24 0.317 7
25 26 27 28 29 30 31 1.177 32 1.336 33 1.105 34 1.216 35 1.031 36 0.606 37 0.317 83 0.394 100 0.800 117 0.800 134 0.395 0.377 1.0 1.336 1.105 1.216 1.303 1 0,.1 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 0.220 0.817 1.031 0.966 1.116 1.317 1.170 '1.346 1.169 1.316 1.116 0.966 1.031 0.817 0.220 53 54 55 56 57 58 59 60 61 62 63 64 65 1 66 67 0.535 1.020 1.216 1.116 1.299 1.153 1.322 1.131 1.321 1.152 1.299 1.116 1.217 1.020 0.535 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 0.880 1.204 1.105 1.316 1.152 1.303 1.095 1.261 1.094 1.303 1.153 1.317 1.106. 1.205 0.880 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 1.086 1.190 1.336 1.169 1.321 1.094 1.175 0.868 1.175 1.095 1.322 1.170 1.338 1.192 1.088 102 103 104 105 106 107 108 109 110 ill 112 113 114 115 116 0.970 1.307 1.177 1.346 1.131 1.261 0.868 0.753 0.868 1.261 1.131 1.346 1.177 1.307 0.970 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 1.088 1.192-1.338 1.170 1.322 1.095 1.175 0.868 1.175 1.094 1.321 1.169 1.336 1.190 1.086 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 0.880 1.205 1.106 1.317 1.153 1.303 1.094 1.261 1.095-1.303 1.152 1.316 1.105 1.204 0.880 151 152 153 154 155 156 157 158 159 1 60 161 162 163 164 165 0.535 1.020 1.217 1.116 1.299 1.152 1.321 1.131 1.322 1.153 1.299 1.116 1.216 1.020 0.535 166 167 168 169 170 171 172 173.
174.
175 176 177 178 179 180 0.220 0.817 1.031 0.966 1.116 1.316 1.169 1.346 11.170 1.317 1.116 0.966 1.031 10.817 0.220 84 0.395 101 0.800 118 0.800 135 0.394 181 0.317 182 0.606 183 1.03 1 184 1.216 185 1-io5 186 1.336 187 1.177 188-
, 189 1.338 1.106 190 1.217 191 1.031 192 0.606 193 0.317 194 0.317 195 0.817 196 1.020 197 1.204 198 1.190 199 1.307 200 201 1.19 1.205 12020 203 1.020 0.81~
204 0.317 7
I 4I..
I.
~
4
~
7 205 0.220 206 0.535 207 0.880 208 1.086 209 0.970 210 211 1.088 0.880 212 213 0.535 0.220 214 2150 0.394 0.800 02160 ý217 0.800
.395
SONGS-2 Cycle 15 Summary Report Page 17 of 33 ATTACHMENT 1 TEST RESULTS TABLE 3 80% RADIAL POWER DISTRIBUTION MEASURED RELATIVE POWER DENSITIES 1
2 3
4 0.405 0.802 0.803 0.406 Assy #
RPD 5
0.229 6
0.553 7
8 0.926 1.096 9
0.963 10 1.098 11 0.931 12 0.558 13ý 0.234 14 0.327 15 0.833 16 1.03 1 17 1.209 18
.182 19 1.294 20 1.186 21 1.216 22 1.039 23 0.842 24 0.33 1
0.4 0.33 25 0.325 26 0.62 27 1.061 28 1.21 29 1.08
ý30 1.32 31 1.164 32 1.322 33 1.086 34 1.227 35 1.073 36 0.627 37 0.329 7
83 0.407 100 0.801 117 0.8 134 0.4 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 0.222 0.815 1.028 0.971 1.112 1.298 1.163 1.333 1.166 1.303 1.121 0.982 1.039 0.824 0.224 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 0.536 1.013 1.2 1.092 1.28 1.14 1.311 1.124 1.312 1.138 1.288 1.105 1.214 1.026 0.539 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 0.88 1.193 1.093 1.294 1.145 1.295 1.102 1.265 11.102 1.299 1.152 1.306 1.1041 1.202 0.8821 85 86 87 88 89 90 1-91 92 93 94 95 96 97 98 99 1.085 1.179 1.318 1.152 1.311 1.098 1.186 0.89 1.187 1.102 1.317 1.161 1.328 1.186 1.087 102 103 104 105 106 107 108 109 110 ill 112 113 114 115 116 0.972 1.294 1.165 1.329 1.131 1.264 0.884 0.776 0.882 1.266 1.134 1.333 1.168 1.294- 0.971 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 1.083 1.179 1.321 1.153 1.312 1.1 1.19 0.898 1.191 1.104 1.314 1.153 1.316 1.17 1.079 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 0.878 1.195 1.097 1.299 1.149 1.299 1.106 1.271 1.107 1.301 1.148 1.297 1.092 1.189 0.875 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 0.536 1.019 1.207 1.1 1.287 1.143 1.316 1.128 1.316 1.145 1.285 1.099 1.202 1.014 0.535 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 0.223 0.818 1.033 0.977 1.121 1.311 1.169 1.337 1.167 1.303 1.114 0.97 11.027 10.815 10.222J 84 0.403 101 0.801 118 0.799 135 0.402 181 0.325 182 0.622 183
.065 184 1.228 185 1.109 186 1.328 187 1.167 188 1.326 189 1.088 190 1.214 191 1.046 192 1193 0.617 10.327 1
+
I 4
4 I
.4
-t t
4 4
194 0.327 195 0.834 196 1.029 197 1.20 1 198 1.178 199 1.293 200 1.188 201 202 1.21 1.028 203 0.827 204 0.325 205 0.228 206 0.54 207 0.876 208 1.074 209 0.958 210 1.092 211 212 0.92 0.551 213 0.23 214 2151 ý216 0217 0.393 0.79 1
.797 0.402
SONGS-2 Cycle 15 Summary Report Page 18 of 33 ATTACHMENT 1 TEST RESULTS TABLE 3 80% RADIAL POWER DISTRIBUTION ASSEMBLY 1
2 3
4 5
'6 7
8 9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 MEASURED 0.405 0.802 0.803 0.406 0.229 0.553 0.926 1.096 0.963 1.098 0.931 0.558 0.234 0.327 0.833 1.031 1.209 1.182 1.294 1.186 1.216 1.039 0.842 0.33 0.325 0.62 1.06 1 1.217 1.08 1.32 1.164 1.322 1.086 1.227 1.073 0.627 0.329 0.222 0.815 i1.028 PREDICTED 0.3946 0.8004 0.7996 0.3942 0.2199 0.5349 0.8804 1.0877 0.9705 1.0863 0.8799 0.5355 0.2201 0.3173 0.817
.1.02 1.2053 1.1919 1.3067 1.1902 1.2042 1.02 0.81 68 0.31 71 0.31 71 0.6056 1.0309 1.21 68 1.1062 1.3384 1.1769 1.3356 1.1048 1.21 63 1.0305 0.6056 0.31 73 0.2201 0.8168 1.0305 DIFFERENCE 0.0104 0.0016 0.0034 0.0118 0.0091 0.01 81 0.0456 0.0083
-0.0075 0.0117 0.0511 0.0225 0.01 39 0.0097 0.016 0.011 0.0037
-0.0099
-0.0127
-0.0042 0.0118 0.019 0.0252 0.0129 0.0079 0.01 44 0.0301 0.0002
-0.0262
-0.0184
-0.0129
-0.0136
-0.0188 0.01 07 0.0425 0.0214 0.0117
- 0.0019
-0.0018
- -0.0025 DIFF /PRED 0.0264 0.002 0.0043 0.0299 0.0414 0.0338 0.0518 0.0076
-0.0077 0.01 08 0.0581 0.042 0.0632 0.0306 0.0196 0.01 08 0.0031
-0.0083
-0.0097
-0.0035 0.0098 0.0186 0.0309 0.0407 0.0249 0.0238 0.0292 0.0002
-0.0237
-0.0137
-0.01 1
-0.0102
-0.017 0.0088 0.0412 0.0353 0.0369 0.0086
-0.0022
-0.0024
SONGS-2 Cycle 15 Summary Report Page 19 of 33 ATTACHMENT 1 TEST RESULTS TABLE 3 POWER DISTRIBUTION ASSEMBLY 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 80% RADIAL MEASURED 0.971 1.112 1.298 1.163 1.333 1.166 1.303 1.121 0.982 1.039 0.824 0.224 0.536 1.013 1.2 1.092 1.28 1.14 1.311 1.124 1.312 1.138 1.288 1.105 1.214 1.026 0.539 0.88 1.193 1.093 1.294 1.145 1.295 1.102 1.265 1.1Q02 1.299 1.152 1.306 1.104 PREDICTED 0.9657 1.1161 1.3171 1.1702 1.3461 1.1688 1.31 59 1.1161 0.9657 1.0309 0.817 0.2199 0.5355 1.02 1.2163 1.1161 1.2991 1.1531 1.3221 1.131 1.3213 1.1516 1.2991 1.1161 1.2168 1.02 0.5349 0.8799 1.2042 1.1048 1.3159 1.1516 1.3033 1.0947 1.2609 1.0937 1.3033 1.1531 1.3171 1.1062 DIFFERENCE 0.0053
-0.0041
-0.0191
-0.0072
-0.0131
-0.0028
-0.0129 0.0049 0.0163 0.0081 0.007 0.0041 0.0005
-0.007
-0.0163
-0.0241
-0.0191
-0.0131
-0.0111
-0.007
-0.0093
-0.0136
-0.0111
-0.0111
-0.0028 0.006 0.0041 0.0001
-0.0112
-0.0118
-0.0219
-0.0066
-0.0083 0.0073 0.0041 0.0083
-0.0043
-0.0011
-0.0111
-0.0022 DIFF / PRED 0.0055
-0.0037
-0.0145
-0.0062
-0.0097
-0.0024
-0.0098 0.0044 0.0169 0.0079 0.0086 0.0186 0.0009
-0.0069
-0.0134
-0.0216
-0.0147
-0.0114
-0.0084
-0.0062
-0.007
-0.0118
-0.0085
-0.0099
-0.0023 0.0059 0.0077 0.0001
-0.0093
-0.0107
-0.0166
-0.0057
-0.0064 0.0067 0.0033 0.0076
-0.0033
-0.001
-0.0084
-0.002
SONGS-2 Cycle 15 Summary Report Page 20 of 33 ATTACHMENT 1 TEST RESULTS TABLE 3 POWER DISTRIBUTION 80% RADIAL ASSEMBLY 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 MEASURED 1.202 0.882 0.407 0.403 1.085 1.179 1.318 1.152 1.311 1.098 1.186 0.89 1.187 1.102 1.317 1.161 1.328 1.186 1.087 0.801 0.801 0.972 1.294 1.165 1.329 1.131 1.264 0.884 0.776 0.882 1.266 1.134 1.333 1.168 1.294 0.971 0.8 0.799 1.083 1.179 PREDICTED 1.2053 0.8804 0.3942 0.3946 1.0863 1.1902 1.3356 1.1688 1.3213 1.0937 1.1749 0.8675 1.1749 1.0947 1.3221 1.1702 1.3384 1.1919 1.0877 0.7996 0.8004 0.9705 1.3067 1.1769 1.3461 1.131 1.2609 0.8675 0.7528 0.8675 1.2609 1.131 1.3461 1.1769 1.3067 0.9705 0.8004 0.7996 1.0877 1.1919 DIFFERENCE
-0.0033 0.0016 0.0128 0.0084
-0.0013
-0.0112
-0.0176
-0.0168
-0.0103 0.0043 0.0111 0.0225 0.0121 0.0073
-0.0051
-0.0092
-0.0104
-0.0059
-0.0007 0.0014 0.0006 0.0015
-0.0127
-0.0119
-0.0171 0
0.0031 0.0165 0.0232 0.0145 0.0051 0.003
-0.0131
-0.0089
-0.0127 0.0005
-0.0004
-0.0006
-0.0047
-0.0129 DIFF/PRED
-0.0027 0.0018 0.0325 0.0213
-0.0012
-0.0094
-0.0132
-0.0144
-0.0078 0.0039 0.0094 0.0259 0.0103 0.0067
-0.0039
-0.0079
-0.0078
-0.005
-0.0006 0.0018 0.0007 0.0015
-0.0097
-0.0101
-0.0127 0
0.0025 0.019 0.0308 0.0167 0.004 0.0027
-0.0097
-0.0076
-0.0097 0.0005
-0.0005
-0.0008
-0.0043
-0.0108 C
SONGS-2 Cycle 15 Summary Report Page 21 of 33 ATTACHMENT 1 TEST RESULTS TABLE 3 POWER DISTRIBUTION ASSEMBLY 121 122 123 124 125 126 127 128 129 130 131
- 132, 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 80% RADIAL MEASURED 1.32 1 1.153 1.312 1.1 1.19 0.898 1.191 1.104 1.314 1.153 1.316 1.17 1.079
- 0.4 0.878 1.195 1.097 1.299 1.149 1.299 1.106 1.27 1 1.107 1.30 1 1.148 1.297 1.092 1.189 0.875 0.536 1.019 1.207 1.1 1.287 1.143 1.316 1.128 1.316 1.145 PR ED ICTED 1.3384 1.1702 1.3221 1.0947 1.1749 0.8675 1.1749 1.0937 1.3213 1.1688 1.3356 1.1902 1.0863 0.3946 0.3942 0.8804 1.2053 1.1062 1.31 71 1.1531 1.3033 1.0937 1.2609 1.0947 1.3033 1.1516 1.31 59 1.1048 1.2042 0.8799 0.5349 1.02 1.21 68 1.1161 1.2991 1.1516 1.3213 1.131 1.3221 1.1531 DIFFERENCE
-0.01 74
-0.0172
-0.01 01 0.0053 0.01 51 0.0305 0.01 61 0.01 03
-0.0073
-0.0158
-0.0196
-0.0202
-0.0073 0.0054 0.0078
-0.0024
-0.0103
-0.0092
-0.0181
-0.0041
-0.0043 0.0123 0.01 01 0.01 23
-0.0023
-0.0036
-0.01 89
-0.0128
-0.0152
-0.0049 0.0011
-0.001
-0.0098
-0.01 61
-0.0121
-0.0086
-0.0053
-0.003
-0.0061
-0.0081 DIFF / PRED
-0.013
-0.0147
-0.0076 0.0048 0.01 29 0.0352 0.0137 0.0094
-0.0055
-0.0135
-0.0147
-0.017
-0.0067 0.01 37 0.0198
-0.0027
-0.0085
-0.0083
-0.0137
-0.0036
-0.0033 0.0112 0.008 0.0112
-0.0018
-0.0031
-0.01 44
-0.0116
-0.0126
-0.0056 0.0021
-0.001
-0.0081
-0.0144
-0.0093
-0.0075
-0.004
-0.0027
-0.0046
-0.007
SONGS-2 Cycle 15 Summary Report Page 22 of 33 ATTACHMENT 1 TEST RESULTS TABLE 3 POWER DISTRIBUTION 80% RADIAL ASSEMBLY 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 MEASURED 1.285 1.099 1.202 1.014 0.535 0.223 0.818 1.033 0.977 1.121 1.311 1.169 1.337 1.167 1.303 1.114 0.97 1.027 0.815 0.222 0.325 0.622 1.065 1.228 1.109 1.328 1.167 1.326 1.088 1.214 1.046 0.617 0.327 0.327 0.834 1.029 1.201 1.178 1.293 1.188 PREDICTED 1.2991 1.1161 1.2163 1.02 0.5355 0.2199 0.817 1.0309 0.9657 1.1161 1.3159 1.1688 1.3461 1.1702 1.3171, 1.1161 0.9657 1.0305 0.8168 0.2201 0.3173 0.6056 1.0305 1.21 63 1.1048 1.3356 1.1769 1.3384 1.1062 1.2168 1.0309 0.6056 0.3171 0.3171 0.8168 1.02 1.2042 1.1902 1.3067 1.1919 DIFFERENCE
-0.0141
-0.0171
-0.0143
-0.006
-0.0005 0.0031 0.001 0.0021 0.0113 0.0049
-0.0049 0.0002
-0.0091
-0.0032
-0.0141
-0.0021 0.0043
-0.0035
-0.0018 0.0019 0.0077 0.0164 0.0345 0.0117 0.0042
-0.0076
-0.0099
-0.0124
-0.0182
-0.0028 0.0151 0.0114 0.0099 0.0099 0.0172 0.009
-0.0032
-0.0122
-0.0137
-0.0039 DIFF / PRED
-0.0109
-0.0153
-0.0118
-0.0059
-0.0009 0.0141 0.0012 0.002 0.0117 0.0044
-0.0037 0.0002
-0.0068
-0.0027
-0.0107
-0.0019 0.0045
-0.0034
-0.0022 0.0086 0.0243 0.0271 0.0335 0.0096 0.0038
-0.0057
-0.0084
-0.0093
-0.0165
-0.0023 0.0146 0.0188 0.0312 0.0312 0.0211 0.0088
-0.0027
-0.0103
-0.0105
-0.0033
SONGS-2 Cycle 15 Summary Report Page 23 of 33 ATTACHMENT 1 TEST RESULTS TABLE 3 POWER DISTRIBUTION ASSEMBLY 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 80% RADIAL MEASURED 1.21 1.028 0.827 0.325 0.228 0.54 0.876 1.074 0.958 1.092 0.92 0.551 0.23 0.393 0.791 0.797 0.402 PREDICTED 1.2053 1.02 0.817 0.3173 0.2201 0.5355 0.8799 1.0863 0.9705 1.0877 0.8804 0.5349 0.2199 0.3942 0.7996 0.8004 0.3946 DIFFERENCE 0.0047 0.008 0.01 0.0077 0.0079 0.0045
-0.0039
-0.0123
-0.0125 0.0043 0.0396 0.0161 0.0101
-0.0012
-0.0086
-0.0034 0.0074 DIFF/PRED 0.0039 0.0078 0.0122 0.0243 0.0359 0.0084
-0.0044
-0.0113
-0.0129 0.004 0.045 0.0301 0.0459
-0.003
-0.0108
-0.0042 0.0188 SUM OF THE SQUARES OF THE RMSERROR=
.0130 DIFFERENCES =.0364 ALL BUNDLE POWERS MEET THE ACCEPTANCE CRITERIA
ATTACHMENT 1 TEST RESULTS TABLE 4 80% CORE AVERAGE AXIAL POWER SONGS-2 Cycle 15 Summary Report Page 24 of 33 DISTRIBUTION PCT.
HT.
100 (TOP) 98 96 94 92 90 88 86 84 82 80 78 76 74 72 70 68 66 64 62 60 58 56 54 52 50 48 46 44 42 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8
6 4
2 0 (SOT)
MEASURED VALUE 0.4087 0.5185 0.6196 0.7915 0.8612 0.9201 0.9686 1.0077 1.0384 1.0621 1.08 1.0936 1.1041 1.1125 1.1197 1.1264 1.133 1.1396 1.146 1.1522 1.1578 1.1624 1.1656 1.1671 1.1668 1.1647 1.1607 1.1552 1.1485 1.141 1.1331 1.1251 1.1174 1.1099 1.1026 1.0951 1.0866 1.0764 1.0633 1.046 1.0232 0.9935 0.9555 0.9082 0.8506 0.7822 0.7029 0.613 0.51 31 0.4046 PREDICTED VALUE 0.397 0.55 0.689 0.781 0.859 0.923 0.974 1.016 1.05 1 1.079 1.102 1.12 1.136 1.148 1.158 1.166 1.17?
1.176 1.18 1.182 1,182 1.182 1.18 1.176 1.172 1.167 1.161 1.154 1.146 1.138 1.128 1.117 1.106 1.093 1.079 1.064 1.048 1.03 1.011 0.99 0,967 0.941 0.9 13 0.88 0.842 0.797 0.743 0.678 0.601 0.48 0.347 DIFFERENCE
- 0. 0117
-0.0315
-0.0694
-0.0701
-0.0675
-0.0618
-0.0539
-0.0474
-0.0433
-0.0406
-0.0399
-0.04
-0.0424
-0.0439
-0.0455
-0.0463
-0.0456
-0.043
-0.0404
-0.036
-0.0298
-0.0242
-0.0176
-0.0104
-0.0049
-0.0002 0.0037 0.0067 0.0092 0.0105 0.013 0.0 161 0.0191 0.0244 0.0309 0.0386 0.0471 0.0566 0.0654 0.0733 0.079 0.0822 0.0805 0.0755 0.0662 0.0536 0.0392 0.0249 0.012' 0.0331 0.0576 SUM OF THE SQUARES OF THE DIFFERENCES =.1061 RMS ERROR =
.0456
SONGS-2 Cycle 15 Summary Report Page 25 of 33 ATTACHMENT 1 TEST RESULTS TABLE 5 100% RADIAL POWER DISTRIBUTION PREDICTED RELATIVE POWER DENSITIES 1
2 3
-4 0.397 0.801 0.800 10.397 Assy #
RPD 5
0.223 6
7 0.538 0.88 8
1.085 9
0.97 10 1.084 11 0.88
'.12 13 0.539 0.223 t
4 4
+
-d 4
14 15 16 17 18 19 20 22 23 24 14 0.321 15 0.82 16 1.02 17 1.201 18 1.188 19 1.3 20 1.186 21 1.2 22 1.02 23 0.82 24 0.321 0.32 1 0.82 1.02 1.20 1 1.188 1.3 1.186 1.02 0.82 0.321 1
t 1~
1 t
I I
4 1
+
25 37 25 0.321 26 0.611 27 1.032 28 1.21 29 1.105 30 1.333 31 1.174 32 1.33 33 1.104 34 1.214 35 1.032 36 0.61 1 37 4
83 0.397 100 0.8 117 0.801 134 0.397 0.324 1.3 114121 0201 0321 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 0.223 0.82 1.032 0.969 1.117 1.313 1.169 1.342 1.168 1.312 1.117 0.969 1.032 0.82 0.223 53 54 55 56 57 58 59 60 61 62 63 64 65
.66 67 0.539 1.02 1.214 1.117 1.297 1.153 1.32 1.132 1.319 1.152 1.297 1.117 1.214 1.02 0.538 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 0.88 1.2 1.104 1.312 1.152 1.302 1.098 1.263 1.097 1.302 1.153 1.313 1.105 1.201 0.88 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 1.084 1.186 1.33 1.168 1.319 1.097 1.18 0.876 1.18 1.098 1.32 1.169 1.333 1.188 1.085 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 0.97 1.3 1.174 1.342 1.132 1.263 0.876 0.763 0.876 1.263 1.132 1.342 1.174 1.3 0.97
-119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 1.085 1.188 1.333 1.169 1.32 1.098 1.18 0.876 1.18 1.097 1.319 1.168 1.33 1.186 1.084 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 0.88 1.201 1.105 1.313 1.153 1.302 1.097 1.263 1.098 1.302 1.152 1.312 1.104 1.2 0.88 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 0.538 1.02 1.214 1.117 1.297 1.152 1.319 1.132 1.32 1.153 1.297 1.117 1.214 1.02 0.539 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 0.223 0.82 1.032 0.969 1,117 1,312 1.168 1.342 1.169 1.313 1.117 0.969 1.032 0.82 0.223 84 0.397 101 0.80 1 118
-0.8 135 0.397 181 0.321 182 0.611 183 1.032 184 1.214 185 1.104 186 1.33 187 1.174 188 --
1.333 189 1.105 190 1.214 191 1.032 192 0.611 193 0.32 1 t
1 i
I-10.321 194 0.321 195 0.82 196 1.02 197 198 1.2 1.186 199 1.3 200 1.188 201 1.20 1 202 1.02 203 0.82 204 0.321 1.201 1.0 0.8 032 205 0.223 206 0.539 207 208 0.88 1.084 209 0.97 210 1.085 211 0.88 212 0.538 213 0.223 214 215.-
2161 217 0.397 0.8 0.801 0.3971
SONGS-2 Cycle 15 Summary Report Page 26 of 33 ATTACHMENT 1 TEST RESULTS TABLE 5 100% RADIAL POWER DISTRIBUTION MEASURED RELATIVE POWER DENSITIES 0.402 2
3 4
10.797 10.798 0.404 Assy #
RPD 5
6 0.552 7
0.921 8
1.09 1 9
0.958 10 1.094 11 0.926 12 0.558 13 0.238 18 19 20 21 22 23 2
14 0.327 15 0.834 16 1.028 17 1.206 18 1.178 19 1.291 1
20
.182 21 1.213 22 23 1.037 1 0.843 24 0.331 1.178 1.29 1
.182 1.213 1.037 0.843 0.331 4-4 4-4
+
4
+
4-
+
25 0.331 26 0.62 1 27 1.059 28 1.216 29 1.078 30 1.318 31
.159 32 1.32 33 1.083 34 1.226 35 1.072 36 37
- 0. 629 0.334 1
83 0.41 100 0.8 117 0.799 134 0.403 38 39 40 141 42 43 44 45 46 47 48 49 150 1 51 52 0.223 0.817 1.03 0.97 1.111 1.298 1.162 1.333 1.164 1.303 1.12 0.981 1041 0.827 0.225 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 0.536 1.013 1.202 1.093 1.282 1.139 1.313 1.124 1.314 1.138 1.289 '1. 104 1.215 1.025 0.539 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 0.881 1.193 1.092 1.295 1.145, 1.298 1.104 1.271 1.105 1.301 1.152 1.306 1.102 1.201 0.882 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 1.085 1.174 1.317 1.151 1.313 1.101 1.193 0.9 1.193 1.104 1.319 1.16 1.326 1.179 1.085 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 0.97 1.291 1.162 1.329 1.132 1.268 0.888 0.782 0.886 1.27 1.134 1.332 1.164 1.29 0.968 119 120 121 122 123 124 125 126 127 128 129 130 131' 132 133 1.083 1.174 1.32 1.152 1.314 1.102 1.197 0.907 1.198 1.107 1.316 1.151 1.314 1.163 1.078 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 0.878 1.194 1.096 1.3 1.148 1.302 1.109 1.277 1.109-1.304 1.148 1.298 1.09 1.188 0.875 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 0.535 1.016 1.207 1.099 1.288 1.142 1.318_
1.128 1.319 1.146 1.287 1.099 1.203 1.013 0.535 166 167 168 169 170 171 172 173 174 175
-176 177 178 179 180 0.223 0.82 1.034 0.976 11.119 1.312 1.168 1.338 11.166 11.304 1.113 0.969 11.029 10.818 10.222 84 0.405 101 0.799 118 0.797 135 0.404 181 0.33 182 0.623 183 1.063 184 1.228 185 1.108 186 1.328 187 1.165 188 1.325 189 1.086 190 1.214 191 1.044 192 0.618 193 0.333
- 4..
4-4-4-
4 194 0.328 195 0.835 196 1.028 197 1.20 1 198 1.176 199 1.292 200 1.185 201 1.208 202 1.026 203.
0.827 204 0.325 205 0.232 206 0.541 207 0.876 208 1.073 209 0.954 210 1.089 211 0.916
'212 0.55 213 0.232 214 215
ý 216 02171 0.392 0.787 0.793 0.401
SONGS-2 Cycle 15 Summary Report Page 27 of 33 ATTACHMENT 1 TEST RESULTS TABLE 5 100% RADIAL POWER DISTRIBUTION ASSEMBLY MEASURED PREDICTED DIFFERENCE DIFF IPRED 1
0.402 0.3971 0.0049 0.0123 2
0.797 0.8011
-0.0041
-0.0051 3
0.798 0.8003
-0.0023
-0.0029 4
0.404 0.3967 0.0073 0.01 84 5
0.234 0.2227 0.0113 0.0507 6
0.552 0.5383 0.01 37 0.0255 7
0.921 0.8804 0.0406 0.0461 8
1.091 1.0848
-0.0062 0.0057 9
0.958 0.9697
-0.0117
-0.0121 10 1.094 1.0835 0.0105 0.0097 11 0.926 0.8799 0.046 1 0.0524 12 0.558 0.539 0.019 0.0353 13 0.238 0.223 0.015 0.0673 14 0.327 0.3213 0.0057 0.0177 15 0.834 0.8202 0.0138 0.0168 16 1.028 1.0204 0.0076 0.0074 17 1261.2013 0.0047 0.0039 18 1.178 1.1879
-0.0099
-0.0083 19 1.291 1.3003
-0.0093
-0.0072 20 1.182 1.1862
-0.0042
-0.0035 21 1.213-1.2003 0.0127 0.0106 22 1.037 1.0204 0.0166 0.0163 23 0.843 0.82 0.023 0.028 24 0.331 0.3211 0.0099 0.0308 25 0.331 0.3211 0.0099 0.0308 26 0.621 0.6107 0.0103 0.0169 27 1.059 1.0322 0.0268 0.026 28 1.216 1.2144 0.0016 0.0013 29 1.078 1.1052
-0.0272
-0.0246 30 1.318 1.3327
-0.0147
-0.011 31 1.159 1.1743
-0.0153
-0.013 32 1.32 1.33
-0.01
-0.0075 33 1.083 1.1038
-0.0208
-0.0188 34 1.226 1.2139 0.0121 0.01 35 1.072 1.0318
.0.0402 0.039 36 0.629 0.61 07 0.01 83 0.03 37 0.334 0.3213 0.01 27 0.0395 38 0.223 0.223 0
0 39 0.817 0.82
-0.003
-0.0037 40 1.03 1.0318
-0.0018
-0.0017
SONGS-2 Cycle 15 Summary Report Page 28 of 33 ATTACHMENT 1 TEST RESULTS TABLE 5 100% RADIAL POWER DISTRIBUTION ASSEMBLY MEASURED PREDICTED DIFFERENCE DIFF / PRED 41 0.97 0.9688 0.0012 0.0012 42 1.111 1.1167
-0.0057
-0.0051 43 1.298 1.3134
-0.0154
-0.0117 44 1.162 1.1691
-0.0071
-0.0061 45 1.333 1.3418
-0.0088
-0.0066 46 1.164 1.1677
-0.0037
-0.0032 47 1.303 1.3124
-0.0094
-0.0072 48 1.12 1.1167 0.0033 0.003 49 0.981 0.9688 0.0122 0.0126 50 1.041 1.0322
.0.0088 0.0085 51 0.827 0.8202 0.0068 0.0083 52 0.225 0.2227 0.0023 0.01 03 53 0.536 0.539
-0.003
-0.0056 54 1.013 1.0204
-0.0074
-0.0073 55 1.202 1.2139
-0.0119
-0.0098 56 1.093 1.1167
-0.0237
-0.0212 57 1.282 1.2967
-0.0147
-0.0113 58 1.139 1.1533
-0.0143
-0.0124 59 1.313 1.3198
-0.0068
-0.0052 60 1.124 1.1321
-0.0081
-0.0072 61 1.314 1.3191
-0.0051
-0:0039 62 1.138 1.1518
-0.0138
-0.012 63 1.289 1.2967
-0.0077
-0.0059 64 1.104 1.1167
-0.0127
-0.0114 65 1.215 1.2144 0.0006 0.0005 66 1.025 1.0204 0.0046 0.0045 67 0.539 0.5383 0.0007 0.0013 68 0.881 0.8799
- 0.0011 0.0013 69 1.193 1.2003
-0.0073
-0.0061 70 1.092 1.1038
-0.0118
-0.0107 71 1.295 1.3124
-0.0174
-0.0133 72 1.145 1.1518
-0.0068
-0.0059 73 1.298 1.3022
-0.0042
-0.0032 74 1.104 1.0979 0.0061 0.0056 75 1.271 1.2626 0.0084 0'0067 76 1.105 1.0969 0.0081 0.0074 77 1.301 1.3022
-0.0012
-0.0009 78 1.152 1.1533
-0.0013
-0.0011 79 1.306 1.3134
-0.0074
-0.0056 80 1.102 1.1052
-0.0032
-0.0029
SONGS-2 Cycle 15 Summary Report Page 29 of 33 ATTACHMENT 1 TEST RESULTS TABLE 5 100% RADIAL POWER DISTRIBUTION ASSEMBLY MEASURED PREDICTED DIFFERENCE DIFF / PRED 81 1.201 1.2013
-0.0003
-0.0002 82 0.882 0.8804 0.0016 0.0018 83 0.41 0.3967 0.0133 0.0335 84 0.405 0.3971 0.0079 0.0199 85 1.085 1.0835 0.0015 0.0014 86 1.174 1.1862
-0.0122
-0.0103 87 1.317 1.33
-0.013
-0.0098 88 1.151 1.1677
-0.0167
-0.0143 89 1.313 1.3191
-0.0061
-0.0046 90 1.101 1.0969 0.0041 0.0037 91 1.193 1.1796 0.0134 0.0114 92 0.9 0.8758 0.0242 0.0276 93 1.193 1.1796 0.0134 0.0114 94 1.104 1.0979 0.0061 0.0056 95 1.319 1.3198
-0.0008
-0.0006 96 1.16 1.1691
-0.0091
-0.0078 97 1.326 1.3327
-0.0067
-0.005 98 1.179 1.1879
-0.0089
-0.0075 99 1.085 1.0848 0.0002 0.0002 100 0.8 0.8003
-0.0003
-0.0004 101 0.799 0.8011
-0.0021
-0.0026 102 0.97 0.9697 0.0003 0.0003 103 1.291 1.3003
-0.0093
-0.0072 104 1.162 1.1743
-0.0123
-0.0105 105 1.329 1.3418
-0.0128
-0.0095 106 1.132 1.1321
-0.0001
-0.0001 107 1.268 1.2626 0.0054 0.0043 108 0.888 0.8758 0.0122 0.0139 109 0.782 0.7634 0.0186 0.0244 110 0.886 0.8758 0.0102 0.0116 111 1.27 1.2626 0.0074 0.0059
.112 1.134 1.1321 0.0019 0.0017 113 1.332 1.3418
-0.0098
-0.0073 114 1.164 1.1743
-0.0103
-0.0088 115 1.29 1.3003
-0.0103
-0.0079 116 0.968 0.9697
-0.0017
-0.0018 117 0.799 0.8011
-0.0021
-0.0026 118 0.797 0.8003
-0.0033
-0.0041 119 1.083 1.0848
-0.0018
-0.0017 120 1.174 1.1879
-0.0139
-0.0117
SONGS-2 Cycle 15 Summary Report Page 30 of 33 ATTACHMENT 1 TEST RESULTS TABLE 5 100% RADIAL POWER DISTRIBUTION ASSEMBLY MEASURED PREDICTED DIFFERENCE DIFF IPRED 121 1.32 1.3327
-0.0127
-0.0095 122 1.152 1.1691
-0.0171
-0.0146 123 1.314 1.3198
-0.0058
-0.0044 124 1.102 1.0979 0.0041 0.0037 125 1.197 1.1796 0.0174 0.0148 126 0.907 0.8758 0.0312 0.0356 127 1.198 1.1796 0.0184 0.0156 128 1.107 1.0969 0.0101 0.0092 129 1.316 1.3191
-0.0031
-0.0024 130 1.151 1.1677
-0.0167
-0.0143 131 1.314 1.33
-006-0.012 132 1.163 1.1862
'-0.0232
-0.0196 133 1.078 1.0835
-0.0055
-0.0051 134
.0.403 0.3971 0.0059 0.01 49 135 0.404 0.3967 0.0073 0.0184 136 0.878 0.8804
-0.0024
-0.0027 137 1.194 1.2013
-0.0073
-0.0061 138 1.096 1.1052
-0.0092
-0.0083 139 1.3 1.3134
-0.0134
-0.0102 140 1.148 1.1533
-0.0053
-0.0046 141 1.302 1.3022
-0.0002
-0.0002 142 1.109 1.0969 0.0121 0.011 143 1.277 1.2626 0.0144 0.0114 144 1.109 1.0979 0.0111 0.0101 145 1.304 1.3022 0.0018 0.0014 146 1.148 1.1518
-0.0038
-0.0033 147 1.298 1.3124
-0.0144
-0.011 148 1.09 1.1038
-0.0138
-0.0125 149 1.188 1.2003
-0.0123
-0.0102 150 0.875 0.8799
-0.0049
-0.0056 151 0.535 0.5383
-0.0033
-0.0061 152 1.016 1.0204
-0.0044
-0.0043 153 1.207 1.2144
-0.0074
-0.0061 154 1.099 1.1167
-0.0177
-0.0159 155 1.288 1.2967
-0.0087
-0.0067 156 1.142 1.1518
-0.0098
-0.0085 157 1.318 1.3191
-0.0011
-0.0008 158 1.128 1.1321
-0.0041
-0.0036 159 1.319 1.3198
-0.0008
-0.0006 160 1.146 1.1533
-0.0073
-0.0063
SONGS-2 Cycle 15 Summary Report Page 31 of 33 ATTACHMENT 1 TEST RESULTS TABLE 5 100% RADIAL POWER DISTRIBUTION ASSEMBLY MEASURED
/ PREDICTED DIFFERENCE DIFF /PRED 161 1.287 1.2967
-0.0097
-0.0075 162 1.099 1.1167
-0.0177
-0.0159 163 1.203 1.2139
-0.0109
-0.009 164 1.013 1.0204
-0.0074
-0.0073 165 0.535 0.539
-0.004
-0.0074 166 0.223 0.2227 0.0003 0.0013 167 0.82 0.8202
-0.0002
-0.0002 168 1.034 1.0322 0.0018 0.0017 169 0.976 0.9688 0.0072 0.0074 170 1.119 1.1167 0.0023 0.0021 171 1.312 1.3124
-0.0004
\\-0.0003 172 1.168 1.1677 0.0003 0.0003 173 1.338 1.3418
-0.0038
-0.0028 174 1.166 1.1691
-0.0031
-0.0027 175 1.304 1.3134
-0.0094
-0.0072 176 1.113 1.1167
-0.0037
-0.0033 177 0.969 0.9688 0.0002 0.0002 178 1.029 1.0318
-0.0028
-0.0027 179 0.818 0.82
-0.002
-0.0024 180 0.222 0.223
-0.001
-0.0045 181 0.33 0.3213 0.0087 0.0271 182 0.623 0.6107 0.0123 0.0201 183 1.063 1.0318 0.0312 0.0302 184 1.228 1.2139 0.0141 0.0116 185 1.108 1.1038 0.0042 0.0038 186 1.328 1.33.
-0.002
-0.0015 187 1.165 1.1743
-0.0093
-0.0079 188 1.325 1.3327
-0.0077
-0.0058 189 1.086 1.1052
-0.0192
-0.0174 190 1.214 1.2144
-0.0004
-0.0003 191 1.044 1.0322 0.0118 0.0114 192 0.618 0.6107 0.0073 0.012 193 0.333 0.3211 0.0119 0.0371 194 0.328 0.3211 0.0069 0.0215 195 0.835 0.82 0.015 0.0183 196 1.028 1.0204 0.0076 0.0074 197 1.201 1.2003 0.0007 0.0006 198 1.176 1.1862
-0.0102
-0.0086 199 1.292 1.3003
-0.0083
-0.0064 200 1.185 1.1879
-0.0029
-10.0024
SONGS-2 Cycle 15 Summary Report Page 32 of 33 ATTACHMENT 1 TEST RESULTS TABLE 5 100% RADIAL POWER DISTRIBUTION ASSEMBLY 201 202 203 204 205 206 207 208 209 210
.211 212 213 214 215 216 217 MEASURED 1.208 1.026 0.827 0.325 0.232 0.541 0.876 1.073 0.954 1.089 0.916 0.55 0.232 0.392 0.787 0.793 0.401 PREDICTED 1.2013 1.0204 0.8202 0.3213 0.223 0.539 0.8799 1.0835 0.9697 1.0848 0.8804 0.5383 0.2227 0.3967 0.8003 0.8011 0.3971 DIFFERENCE 0.0067 0.0056 0.0068 0.0037 0.009 0.002
-0.0039
-0.0105
-0.0157 0.0042 0.0356 0.0117 0.0093
-0.0047
-0.0133
-0.0081 0.0039 DIFF / PRED 0.0056 0.0055 0.0083 0.0115 0.0404 0.0037
-0.0044
-0.0097
-0.0162 0.0039 0.0404 0.0217 0.0418
-0.0118
-0.0166
-0.0101 0.0098 SUM OF THE SQUARES OF THE DIFFERENCES =
RMS ERROR =.0118
.0300 ALL BUNDLE POWERS MEET THE ACCEPTANCE CRITERIA
SONGS-2 Cycle 15 Summary Report Page 33 of 33 ATTACHMENT 1 TEST RESULTS TABLE 6 AVERAGE AXIAL POWER DISTRIBUTION 100% CORE PCT.
HT.
100 (TOP) 98 96 94 92 90 88 86 84 82 80 78 76 74 72 70 68 66 64 62 60 58 56 54 52 50 48 46 44 42 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8
6 4
2 0 (BOT)
MEASURED VALUE 0.4062 0.515 0.6152 0.055 0.7853 0.8542 0.9125 0.9605 0.9992 1.0297 1.0532
- 1.0711 1.0848 1.0954 1.1041 1.1117
.1.1188 1.1257 1.1327 1.1396 1.1462 1.1522 1.1572 1.1607 1.1627 1.1628 1.161 1.1576 1.1526 1.1466 1.1399 1.1329 1.1259 1.1194 1.1132 1.1073 1.1012 1.0943 1.0856 1.0739 1.058 1.0363 1.0075 0.9701 0.9231 0.8654 0.7966 0.7165 0.6253 0.5239 0.4135 PREDICTED VALUE 0.377 0.52 0.651 0.738 0.814 0.876 0.927 0.97 1.005 1.034 1.059 1.08 1.098 1.113 1.126 1.137 1.146 1.154 1.16 1.165 1.169 1.172 1.173 1.174 1.173 1.171 1.168 1.164 1.159 1.153 1.147 1.139 1.13 1.119 1.108 1.095 1.081 1.065 1.048 1.028 1.007 0.982 0.954 0.921 0.882 0.837 0.781 0.714 0.634 0.507 0.367 DIFFERENCE 0.0292
-0.005
-0.0358
-0.0325
-0.0287
-0.0218
-0.0145
-0.0095
-0.0058
-0.0043
-0.0058
-0.0089
-0.0132
-0.0176
-0.0219
-0.0253
-0.0272
-0.0283
-0.0273
-0.0254
-0.0228
-0.0198
-0.0158
-0.0133
-0.0103
-0.0082
-0.007
-0.0064
-0.0064
-0.0064
-0.0071
-0.0061
-0.0041 0.0004 0.0052 0.0123 0.0202 0.0293 0.0376 0.0459 0.051 0.0543 0.0535 0.0491 0.0411 0.0284 0.0156 0.0025
-0.0087 0.0169 0.0465 SUM OF THE SQUARES OF THE RMS ERROR = 0.0252 DIFFERENCES =
0.0324