ML082820577

From kanterella
Jump to navigation Jump to search
Meeting Summary, Meeting Between the NRC and PPL Susquehanna, Llc., Concerning Requests for Additional Information Responses Pertaining to the Susquehanna Steam Electric Station, Units 1 and 2, License Renewal Application
ML082820577
Person / Time
Site: Susquehanna  Talen Energy icon.png
Issue date: 10/17/2008
From: Gettys E
License Renewal Projects Branch 1
To:
Gettys Evelyn, NRR/DLR/RLRA 415-4029
References
Download: ML082820577 (7)


Text

October 17, 2008 LICENSEE: PPL Susquehanna, LLC FACILITY: Susquehanna Steam Electric Station, Units 1 and 2

SUBJECT:

SUMMARY

OF TELEPHONE CONFERENCE CALL HELD ON SEPTEMBER 18, 2008, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND PPL SUSQUEHANNA, LLC., CONCERNING REQUESTS FOR ADDITIONAL INFORMATION RESPONSES PERTAINING TO THE SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2, LICENSE RENEWAL APPLICATION The U.S. Nuclear Regulatory Commission and representatives of PPL Susquehanna, LLC, held a telephone conference call on September 18, 2008, to obtain clarifications to the request for additional information responses regarding the Susquehanna Steam Electric Station, Units 1 and 2, license renewal application. By letter dated August 12, 2008, PPL Susquehanna, LLC submitted responses to the request for additional information concerning the Closed Cooling Water Chemistry Program.

provides a listing of the participants and Enclosure 2 contains a listing of the items discussed with the applicant, including a brief description of the resolution of the items.

The applicant had an opportunity to comment on this summary.

\\RA\\

Evelyn Gettys, Project Manager Projects Branch 1 Division of License Renewal Office of Nuclear Reactor Regulation Docket Nos. 50-387 and 50-388

Enclosures:

As stated cc w/encls: See next page

ML082820577 OFFICE LA:DLR PM:RPB1:DLR BC:RER:DLR BC:RPB1:DLR NAME IKing EGettys JDozier DPelton (JRobinson for)

DATE 10/14/08 10/16/08 10/16/08 10/17/08

TELEPHONE CONFERENCE CALL SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2 LICENSE RENEWAL APPLICATION LIST OF PARTICIPANTS SEPTEMBER 18, 2008 PARTICIPANTS AFFILIATIONS Evelyn Gettys U.S. Nuclear Regulatory Commission (NRC)

On Yee NRC Dave Flyte PPL Susquehanna, LLC (PPL)

Dave Cassel PPL ENCLOSURE 1

ENCLOSURE 2 CLARIFICATION ON RESPONSES TO REQUEST FOR ADDITIONAL INFORMATION SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2 LICENSE RENEWAL APPLICATION SEPTEMBER 18, 2008 The U.S. Nuclear Regulatory Commission (NRC or the staff) and representatives of PPL Susquehanna, LLC held a telephone conference call on September 18, 2008, to obtain clarifications to the request for additional information responses regarding the Susquehanna Steam Electric Station, Units 1 and 2, license renewal application.

By letter dated July 10, 2008, the staff requested additional information regarding the Closed Cooling Water Chemistry Program. By letter dated August 12, 2008, PPL Susquehanna, LLC responded to the request for additional information. In the telephone conference on September 18, 2008, the staff wanted to verify the Closed Cooling Water Chemistry Program does handle cracking as an aging effect.

The applicants clarification:

Yes, Closed Cooling Water Chemistry Program is credited with mitigating damage due to cracking.

The applicants clarification:

The Chemistry Program Effectiveness Inspection and will be used for detection of aging effects.

This program will use the appropriate test methods, which will be a combination of volumetric testing and visual examination techniques.

In the telephone conference on September 18, 2008, the staff wanted to know in the letter dated August 12, 2008, if PPL Susquehanna, LLCs response to RAI B.2.14-1 Part b, paragraph two in referencing RAI B.22-02 was a misprint.

The applicants clarification:

It should have been RAI B.2.22-02.

Letter to PPL Susquehanna, LLC from E. Gettys, dated October 17, 2008 DISTRIBUTION:

SUBJECT:

SUMMARY

OF TELEPHONE CONFERENCE CALL HELD ON SEPTEMBER 15, 2008, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND PPL SUSQUEHANNA, LLC, CONCERNING DRAFT REQUESTS FOR ADDITIONAL INFORMATION PERTAINING TO THE SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2, LICENSE RENEWAL APPLICATION HARD COPY:

DLR RF E-MAIL:

PUBLIC RidsNrrDlr RidsNrrDlrRlra RidsNrrDlrRlrb RidsNrrDlrRlrc RidsNrrDlrReba RidsNrrDlrRebb RidsNrrDciCvib RidsNrrDciCpnb RidsNrrDraAfpb RidsNrrDeEmcb RidsNrrDeEeeb RidsNrrDssSrxb RidsNrrDssSbpb RidsNrrDssScvb RidsOgcMailCenter EGettys FJaxheimer

Susquehanna Steam Electric Station, Units 1 and 2 cc:

Cornelius J. Gannon Vice President - Nuclear Operations PPL Susquehanna, LLC 769 Salem Blvd., NUCSB3 Berwick, PA 18603-0467 Robert M. Paley General Manager - Plant Support PPL Susquehanna, LLC 769 Salem Blvd., NUCSB2 Berwick, PA 18603-0467 Rocco R. Sgarro Manager - Nuclear Regulatory Affairs PPL Susquehanna, LLC Two North Ninth Street, GENPL4 Allentown, PA 18101-1179 Supervisor - Nuclear Regulatory Affairs PPL Susquehanna, LLC 769 Salem Blvd., NUCSA4 Berwick, PA 18603-0467 Michael H. Crowthers Supervisor - Nuclear Regulatory Affairs PPL Susquehanna, LLC Two North Ninth Street, GENPL4 Allentown, PA 18101-1179 Ronald E. Smith General Manager - Site Preparedness and Services PPL Susquehanna, LLC 769 Salem Blvd., NUCSA4 Berwick, PA 18603-0467 Michael H. Rose Manager - Quality Assurance PPL Susquehanna, LLC 769 Salem Blvd., NUCSB2 Berwick, PA 18603-0467 Joseph J. Scopelliti Community Relations Manager, Susquehanna PPL Susquehanna, LLC 634 Salem Blvd., SSO Berwick, PA 18603-0467 Bryan A. Snapp, Esq.

Associate General Counsel PPL Services Corporation Two North Ninth Street, GENTW3 Allentown, PA 18101-1179 Document Control Services PPL Susquehanna, LLC Two North Ninth Street, GENPL4 Allentown, PA 18101-1179 Richard W. Osborne Allegheny Electric Cooperative, Inc.

212 Locust Street P.O. Box 1266 Harrisburg, PA 17108-1266 Director, Bureau of Radiation Protection Pennsylvania Department of Environmental Protection Rachel Carson State Office Building P.O. Box 8469 Harrisburg, PA 17105-8469

Susquehanna Steam Electric Station, Units 1 and 2 cc:

Senior Resident Inspector U.S. Nuclear Regulatory Commission P.O. Box 35, NUCSA4 Berwick, PA 18603-0035 Regional Administrator, Region 1 U.S. Nuclear Regulatory Commission 475 Allendale Road Berwick, PA 18603-0467 Board of Supervisors Salem Township P.O. Box 405 Berwick, PA 18603-0035 Dr. Judith Johnsrud National Energy Committee Sierra Club 443 Orlando Avenue State College, PA 16803