W3F1-2008-0045, License Amendment Request Relocation of TS 3.7.8 and Addition of LCO 3.0.8 the Inoperability of Snubbers
| ML082660038 | |
| Person / Time | |
|---|---|
| Site: | Waterford (NPF-038) |
| Issue date: | 09/18/2008 |
| From: | Walsh K Entergy Corp, Entergy Nuclear South, Entergy Operations |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| W3F1-2008-0045, W3F1-2008-0059 | |
| Download: ML082660038 (31) | |
Text
- iiztemvL.ýUlr Entergy Nuclear South Entergy Operations, Inc.
17265 River Road Killona, LA 70057 Tel 504 739 6660 Fax 504 739 6678 kwalshl @entergy.com Kevin T. Walsh Vice President, Operations Waterford 3 W3F1-2008-0059 September 18, 2008 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001
SUBJECT:
REFERENCE:
License Amendment Request NPF-38-279 Relocation of TS 3.7.8 and Addition of LCO 3.0.8 Regarding the Inoperability of Snubbers Waterford Steam Electric Station, Unit 3 Docket No. 50-382 License No. NPF-38
- 1.
Entergy letter dated May 29, 2008, "Inservice Inspection (ISI)
Program Third 10-Year Interval, Revision 0" (W3F1-2008-0045)
Dear Sir or Madam:
In accordance with the provisions of 10 CFR 50.90, Entergy Operations, Inc. (Entergy) hereby requests an amendment to Waterford Steam Electric Station, Unit 3 (Waterford 3)
Technical Specification (TS). The proposed amendment would modify TS requirements for inoperable snubbers by relocating the current TS 3.7.8, Snubbers, to the Technical Requirements Manual (TRM) and adding Limiting Condition for Operation (LCO) 3.0.8. In conjunction with the proposed changes, the TS Bases for LCO 3.0.8 will be added, consistent with Bases Control Program, as described in Section 6.16 of the TS. The proposed amendment is based, in part, on the NRC approved Industry / Technical Specification Task Force (TSTF) change to the Improved Standard Technical Specifications TSTF-372-A, Rev. 4, entitled Addition of LCO 3.0.8, Inoperability of Snubbers and is consistent with changes previously approved by the NRC for other reactor licensees, as well as a recent License Amendment Request from Arkansas Nuclear One, Unit 2. provides a description of the proposed change, the requested confirmation of applicability, and plant-specific verifications. Attachment 2 provides the existing TS pages marked up to show the proposed change. Attachment 3 provides revised (clean) TS pages. provides a summary of the regulatory commitments made in this submittal. provides the existing TS Bases pages marked up to show the proposed changes (for information only).
A D4 q
"'Mt
W3F1-2008-0059 Page 2 The proposed change has been evaluated in accordance with 10 CFR 50.91(a)(1) using criteria in 10 CFR,50.92(c), and it has been determined that this change involves no significant hazards consideration. The bases for these determinations are included in the attached submittal.
Entergy requests approval of the proposed amendment by September 10, 2009, in order to support the Fall 2009 refueling outage. Once approved, the amendment shall be implemented within 60 days. Although this request is neither exigent nor emergency, your prompt review is requested.
If you have any questions or require additional information, please contact Robert Murillo, Manager, Licensing at (504) 739-6715.
I declare under penalty of perjury that the foregoing is true and correct. Executed on September 18, 2008.
Sincerely, KTW/DBB/RLW/ssf Attachments:
- 1.
Description and Assessment
- 2.
Proposed Technical Specification Changes
- 3.
Revised Technical Specification Pages
- 4.
List of Regulatory Commitments
- 5.
Proposed Technical Specification Bases Changes (for information only)
/I,
W3F1 -2008-0059 Page 3 cc:
Mr. Elmo E. Collins Regional Administrator U. S. Nuclear Regulatory Commission Region IV 612 E. Lamar Blvd., Suite 400 Arlington, TX 76011-8064 NRC Senior Resident Inspector Waterford 3 P. 0. Box 822 Killona, LA 70066-0751 U. S. Nuclear Regulatory Commission Attn: Mr. N. Kalyanam MS 0-07 D1 Washington, DC 20555-0001 American Nuclear Insurers Attn: Library 95 Glastonbury Blvd.
Suite 300 Glastonbury, CT 06033-4443 Wise, Carter, Child & Caraway Attn: J. Smith P.O. Box 651 Jackson, MS 39205 Louisiana Department of Environmental Quality Office of Environmental Compliance Surveillance Division P. 0. Box 4312 Baton Rouge, LA 70821-4312 Winston & Strawn ATTN: N.S. Reynolds 1700 K Street, NW Washington, DC 20006-3817 Morgan, Lewis & Bockius LLP ATTN: T.C. Poindexter 1111 Pennsylvania Avenue, NW Washington, DC 20004 To W3FI-2008-0059 Description and Assessment to W3F1 -2008-0059 Page 1 of 5
1.0 DESCRIPTION
The proposed amendment would modify Waterford Steam Electric Station, Unit 3 (Waterford 3)
Technical Specification (TS) requirements for inoperable snubbers by relocating the current TS 3.7.8, Snubbers, to the Technical Requirements Manual (TRM) and adding Limiting Condition for Operation (LCO) 3.0.8. In conjunction with the proposed changes, TS Bases for LCO 3.0.8 will be added, consistent with the Bases Control Program as described in Section 6.16 of the TS.
The changes relating to the addition of LCO 3.0.8 are consistent with the Nuclear Regulatory Commission (NRC) approved Industry / Technical Specification Task Forceý (TSTF) change to the Improved Standard Technical Specifications TSTF-372-A, Rev. 4, entitled Addition of LCO 3.0.8, Inoperability of Snubbers. The availability of this TS improvement was published in the Federal Register on April 27, 2005 as part of the consolidated line item improvement process (CLIIP). The change which relocates TS 3.7.8 to the TRM is consistent with the Improved Standard Technical Specification (STS), which does not contain a specification for snubbers.
2.0 ASSESSMENT
2.1 Applicability of Published Safety Evaluation With regard to application-of TSTF -372 (adoption of LCO 3.0.8), Entergy Operations, Inc.
(Entergy) has reviewed the safety evaluation dated April 27, 2005 as part of the CLIIP. This review included a review of the NRC staff's evaluation, as well as the information provided to support TSTF-372. Entergy has concluded that the justifications presented in the TSTF proposal and the safety evaluation prepared by the NRC staff are applicable to Waterford 3 and justify this amendment for the incorporation of the changes to the Waterford 3 TS.
The relocation of the snubber-related requirements of TS 3.7.8 to the TRM is consistent with the original (and current) version of the STS. The NRC's Final Policy Statement states that LCOs and associated requirements that do not satisfy or fall within any of the four specified criteria presently contained in 10 CFR 50.36, maybe relocated from existing TS (an NRC-controlled document) to appropriate licensee-controlled documents. Relocation of these requirements to the TRM is acceptable, in that, changes to the TRM will be adequately controlled by 10 CFR 50.59. These provisions will continue to be implemented by appropriate station procedures (i.e., operating procedures, maintenance procedures, surveillance and testing procedures, and work control procedures).
Snubbers are used on piping systems or equipment to limit displacement from dynamic loads such as earthquake or thermal-hydraulic transient, while allowing displacement from thermal expansion. Snubbers are not active components, but are a type of support like springs, baseplates, or struts with the same potential for impact on operability as any support. The majority of snubbers at Waterford 3 are installed on Seismic Class I piping, which include all of the safety systems. Snubber testing is required by 10 CFR 50.55a to be performed in accordance with ASME/American Nuclear Standards Institute (ANSI) OM Part 4, "Examination and Performance Testing of Nuclear Power Plant Dynamic Restraints" or ASME OM Code, Subsection ISTD, "Preservice and Inservice Examination and Testing of Dynamic Restraints (Snubbers) in Light-Water Reactor Nuclear Power Plants." Thus, specifying such testing in the to W3F1 -2008-0059 Page 2 of 5 TS is unnecessary. Snubbers are not a design feature that is an initial condition of a DBA or transient. Thus, TS requirements forsnubbers do not meet the criteria of 10 CFR 50.36 for retention in the TS. In addition, snubber degradation does not necessarily render the associated safety system inoperable. Rather, it is appropriate to evaluate issues with a snubber using existing guidance for degraded or nonconforming conditions within the corrective action program. If a problem with one or more snubbers did make a system or component, inoperable, the TS for the affected system will define the appropriate remedial actions. Testing will be adequately controlled in accordance with 10 CFR 50.55a and 10 CFR 50.59. Based on the above, it is acceptable to relocate the snubber specification to the TRM.
2.2 Optional Changes and Variations The relocation of TS 3.7.8 to the TRM is not included in the CLiUP associated with TSTF-372.
However, this relocation is necessary to support application of the new LCO 3.0.8 and the intent of TSTF-372. Furthermore, this relocation is consistent with the STS.
Because Waterford 3 is a non-STS plant and because Entergy proposes to relocate TS 3.7.8 to support the adoption of LCO 3.0.8, these changes are not proposed to be approved under the normal 6-month CLIIP review process. Notwithstanding the additional review and time the NRC may require to issue the requested amendment, Entergy has confirmed that all other requirements of the CLIIP, as stated in Section 2.1 above, are met for Waterford 3. Given the necessity of TS 3.7.8 relocation in order to adopt TSTF-372, Entergy believes this deviation is minor.
Other than discussed above, the only remaining minor deviation is the maintenance of Waterford 3 custom TS wording and usage rules in the adoption of TSTF-372. Specifically:
- 1.
TSTF-372 adds LCO 3.0.8 reference to LCO 3.0.1. Currently, the STS has reference to LCO 3.0.2 and 3.0.7 within LCO 3.0.1. Waterford 3 TS does not contain LCO 3.0.7 (associated with Special Test Exceptions); therefore, reference to LCO 3.0.7 is not included in the Waterford 3 LCO 3.0.1. However, reference to LCO 3.0.2 should be included and, therefore, Entergy is adding this reference to the Waterford 3 LCO 3.0.1 to gain consistency with the STS.
- 2.
As discussed in Item 1 above, Waterford 3 does not have an LCO 3.0.7. However, to maintain consistent numbering (where possible) with the STS, Waterford 3 proposes to add an LCO 3.0.6 and LCO 3.0.7 placeholder which will permit using the LCO 3.0.8 designation for snubbers, consistent with TSTF-372 and the STS.
- 3.
Item 1(e) of the model Safety Evaluation (SE), Section 3.2, contains the statement "LCO 3.0.8 does not apply to non-seismic snubbers." This does not appear to be captured in the implementation process of the TSTF. Therefore, Entergy proposes to include this statement in the LCO 3.0.8 Bases (see Attachment 5 of this submittal). Further guidance associated with the intent of this statement, as discussed in Section 3.0 of the model SE and in TSTF-IG-05-03, Implementation Guidance for TSTF-372, Revision 4, "Addition of LCO 3.0.8, Inoperability of Snubbers," is also included in the Bases. In addition, the TSTF use of "10 CFR 50.36(c)(2)(ii)" is modified to simply state 10 CFR 50.36. This is due to the recent rule change that inadvertently re-designated Part 50.36(c) as Part 50.36(d).
to W3F1 -2008-0059 Page 3 of 5
- 4.
The footer of TS Page 3/4 7-20 is revised to account for the pages being deleted by the relocation of TS 3.7.8. This is administrative in nature.
These variations are few and insignificant with regard to ensuring proper application of TSTF-372 intent. Note that TS Page 3/4 7-20 is tied to the August 16, 2007 Entergy letter to adopt TSTF-448, which is currently under review by the NRC. The proposed changes contained within the TSTF-448 submittal are not shown on the attached mark-up or clean page for TS Page 3/4 7-20.
3.0 REGULATORY ANALYSIS
3.1 No Significant Hazards Consideration Determination Entergy Operations, Inc. (Entergy) has reviewed the proposed no significant hazards consideration determination (NSHCD) published in the Federal Register as part of the CLIIP.
Entergy has concluded that the proposed NSHCD presented in the Federal Register notice is applicable to Waterford 3 and is hereby incorporated by reference to satisfy the requirements of 10 CFR 50.91 (a).
3.2 Verification and Commitments As discussed in the notice of availability published in the Federal Register on April 27, 2005 for this TS improvement, plant-specific verifications were performed as follows:
In the model Safety Evaluation (SE), two Conditions [the first of the two having five parts, 1(a) through 1(e)] for application of TSTF-372 are specified. Each is discussed below.
Condition 1 Appropriate plant procedures and administrative controls will be used to implement the following Tier 2 restrictions. Tier 2 restrictions (Conditions) involve the identification of potentially high-risk configurations that could exist if equipment in addition to that associated with the change were to be taken out of service simultaneously, or other risk significant operational factors such as concurrent equipment testing were also involved.
- 1.
Condition 1(a) assumes the availability of one Emergency Feedwater (EFW) train during application of LCO 3.0.8.a. The TSTF-372 and the model SE specify the application of LCO 3.0&8.a is contingent on the assumption that the redundant train remains available.
Even though Waterford 3 has a unique EFW system design, the plant TS LCO and ACTION statements will ensure the system remains capable of performing its safety function with various combinations of pumps and flow paths OPERABLE. Although the TS implementation process at Waterford 3 may include this restriction in other procedures or administrative processes upon approval of this amendment, Entergy does not believe further action is required to ensure compliance with Condition 1(a) since the TS inherently prevents application of LCO 3.0.8.a due to a snubber-related condition which could render the entire EFW system inoperable.
- 2.
Condition 1(b) requires either one EFW train or some alternative means of core cooling must be available when one or more snubbers are inoperable that affect both trains of a to W3F1 -2008-0059 Page 4 of 5 given system. As described in Condition 1(a) above, there are no instances where the EFW system or both trains of any system being relied upon as the only core cooling method would be removed from service or any work permitting both at the same time during its associated Modes of Applicability that require these systems. Again, such a plant configuration would result in LCO 3.0.3 entry or plant shutdown, which prevents the utilization of the 12-hour allowance of LCO 3.0.8.b. Although the TS implementation process at Waterford 3 may include this restriction in other procedure or administrative processes upon approval of this.amendment, Entergy believes the TS LCO and ACTION statements will ensure the system remains capable of performing its safety function with no further action required to ensure compliance with Condition 1 (b).
- 3.
Conditions 1(c) and 1(d) are only applicable to west coast plants and boiling water reactors, respectively, and therefore, are not applicable to Waterford 3.
- 4.
Condition 1(e), first part, relates to Conditions 1(a) and 1(b) discussed above. The statement "LCO 3.0.8 does not apply to non-seismic snubbers" is added to the TS Bases (see markup in Attachment 5 of this submittal). This is a minor deviation from TSTF-372 and is discussed in Section 2.2 aboye. The second part of Condition 1(e) requires that the design function of the inoperable snubber (i.e., seismic vs. non-seismic), implementation of any Tier 2 restrictions during the use of LCO 3.0.8, and the associated plant configuration are recoverable (e.g. can be produced) for staff inspection. Entergy will ensure, during the relocation of the TS 3.7.8 snubber requirements to the TRM, that the TRM Actions are modified, in accordance with 10 CFR 50.59, to require a record of the design function of the inoperable snubber (i.e.,
seismic vs. non-seismic), implementation of any Tier 2 restrictions each time a required snubber is rendered inoperable and the associated plant configuration are available for NRC staff inspection. This commitment is included in Attachment 4 of this submittal.
Condition 2 Implementation of the provisions of LCO 3.0.8 must be performed in accordance with an overall Continuous Risk Management Program (CRMP). Waterford 3 has and continues to maintain a CRMP and associated risk-related tools to meet the intent of 10 CFR 50.65(a)(4) of the Maintenance Rule. Entergy will revise plant procedures or administrative process to ensure seismic risks are considered in conjunction with other plant maintenance activities and integrated into the existing 10 CFR 50.65(a)(4) process during application of the LCO 3.0.8 delay period when one or more snubbers are inoperable. This commitment is included in Attachment 4 of this submittal.
In addition to the above Conditions, Entergy will establish TS Bases for'LCO 3.0.8 which provide guidance and details on how to implement the new requirements. This commitment is included in Attachment 4 of this submittal. LCO 3.0.8 requires that risk be managed and assessed. The Bases also state that while the Industry and NRC guidance on implementation of 10 CFR 50.65(a)(4) (the Maintenance Rule) does not address seismic risk, LCO 3.0.8 should be considered with respect to other plant maintenance activities, and integrated into the existing Maintenance Rule process to the extent possible so that maintenance on any unaffected train or subsystem is properly controlled, and emergent issues are properly addressed. The risk assessment need not be quantified, but may be a qualitative assessment of the vulnerability of systems and components when one or more snubbers are not able to perform their associated to W3F1 -2008-0059 Page 5 of 5 support function. Finally, Waterford 3 has a Bases Control Program consistent with Section 5.5 of the STS and is contained in Waterford 3 TS Section 6.16.
4.0 ENVIRONMENTAL EVALUATION Entergy has reviewed the environmental evaluation included in the model safety evaluation dated April 27, 2005 as part of the CLIIP. Entergy has concluded that the staff's findings presented in that evaluation are applicable to Waterford 3, and the evaluation is hereby incorporated, by reference for this application.
To W3FI -2008-0059 Proposed Technical Specification Changes C
to W3F 1-2008-0059 Page 1 of 11 3/4 LIMITING CONDITIONS FOR OPERATION AND SURVEILLANCE REQUIREMENTS 3/4.0 APPLICABILITY LIMITING CONDITION FOR OPERATION 3.0.1 Compliance with the Limiting Conditions for Operation (LCO) contained in the succeeding specifications is required during the OPERATIONAL MODES or other conditions specified thereinmox ct that upon failure to meet the Limiting Conditions for Operation, the associ CTION requirements shall be met.
3.0.2 Noncompliance with a specification shall exist when irements of INSER" the Limiting Condition for Operation and/or associated ACTION requirem e
except not met within the specified time intervals. If the Limiting Condition for provide Operation is restored prior to expiration of the specified time intervals, LCO 3.
completion of the ACTION requirements is not required.
or 3.0.
3.0.3 When a Limiting Condition for Operation is not met, except as provided in the associated ACTION requirements, within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />, action shall be initiated to place the unit in a MODE in which the specification does not apply by placing it, as applicable, in:
- 1.
At least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />,
- 2.
At least HOT SHUTDOWN within the following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />, and
- 3.
At least COLD SHUTDOWN within the subsequent 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.
Where corrective measures are completed that-permit operation under the ACTION requirements, the ACTION may be taken in accordance with the specified time limits as measured from the time of failure to meet the Limiting Condition for Operation. Exceptions to these requirements are stated in the individual specifications.
This specification is not applicable in MODE 5 or 6.
3.0.4 Entry into an OPERATIONAL MODE or other specified condition shall not be made when the conditions for the Limiting Conditions for Operation are not met and the ACTION requires a shutdown if they are not met within a specified interval. Entry into an OPERATIONAL MODE or specified condition may be made in accordance with ACTION requirements when conformance to them permits continued operation of the facility for an unlimited period of time. Applying this exception shall be subject to review and approval as described in plant administrative controls unless the individual specification contains an exception to these requirements. This provision shall not prevent passage through or to OPERATIONAL MODES as required to comply with ACTION statements.
3.0.5 Equipment removed from service or declared inoperable to comply with ACTIONS may be returned to service under administrative control solely to perform testing required to demonstrate its OPERABILITY or the OPERABILITY of other equipment. This is an exception to LCO 3.0.2 for the system returned to service under administrative control to perform the testing required to demonstrate OPERABILITY.
WATERFORD - UNIT 3 3/4 0-1 Amendment No. 99,4-04, to W3F1-2008-0059 Page 2 of 11 3/4 LIMITING CONDITIONS FOR OPERATION AND SURVEILLANCE REQUIREMENTS 3/4.0 APPLICABILITY (continued)
LIMITING CONDITION FOR OPERATION INSERT 2 3.0.6 To be used later.
3.0:7 To be used later.
3.0.8 When one or more required snubbers are unable to perform their associated support function(s), any affected supported LCO(s) are not required to be declared not met solely for this reason if risk is assessed and managed, and:
- a.
the snubbers not able to perform their associated support function(s) are associa with only one train or subsystem of a multiple train or subsystem supported syste or are' associated with a single train or subsystem supported system and are ablE perform their associated support function within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />; or
- b.
the snubbers not able to perform their associated support function(s) are associa with more than one train or subsystem of a multiple train or subsystem supported system and are able to perform their associated support function within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.
At the end of the specified period the required snubbers must be able to perform their associated support function(s), or the affected supported system LCO(s) shall be declared not met.
ted m
to ted WATERFORD - UNIT 3 3/4 0-1 a AMENDMENT NO. 4-7-O,-1-4, to W3F 1-2008-0059 Page 3 of 11 PLANT SYSTEMS SURVELLIANCE REQUIREMENTS
- c.
After every 720 hours0.00833 days <br />0.2 hours <br />0.00119 weeks <br />2.7396e-4 months <br /> of charcoal adsorber operation by verifying within 31 days after removal that a laboratory analysis of a representative carbon sample obtained in accordance with Regulatory Position C.6.b of Regulatory Guide 1.52, Revision 2, March 1978, shows the methyl iodide penetration less than 0.5% when tested in
..accordance with ASTM D3803-1989 at a temperature of 300C and a relative humidity of 70%.
- d.
At least once per 18 months by:
- 1.
Verifying that the pressure drop across the combined HEPA filters and charcoal adsorber banks is less than 7.8 inches water gauge while operating the system at a flow rate of 3000,cfm +/- 10%.
- 2.
Verifying that the system starts on a Safety Injectibn Actuation Test Signal and achieves and maintains a negative pressure of _ 0.25 inch water gauge within 45 seconds.
- 3.
Verifying that the filter cooling bypass valves can be manually cycled.
- 4.
Verifying that the heaters dissipate 20 + 2.0, -2.0 kW when tested in accordance with ANSI N510-1975.
- e.
After each complete or partial replacement of a HEPA filter bank by verifying that the HEPA filter banks remove greater than or equal to 99.95% of the DOP when they are tested in-place in accordance with ANSI N510-1975 while operating the system at a flow rate of 3000 cfm +/- 10%.
- f.
After each complete or partial replacement of a charcoal absorber bank by verifying that the charcoal adsorbers remove greater than or equal to 99.95% of a halogenated hydrocarbon refrigerant test gas when they are tested in-place in accordance with ANSI N510-1975 while operating the system at a flow rate of 3000 cfm + 10%.
WATERFORD - UNIT 3 3/4 7-20 AMENDMENT NO. 1-G7,1-94, Next Page is 3/4 7-27 to W3F1-2008-0059 Page 4 of 11
\\LANT SYSTEMS 3/4.
SNUBBERS LIMITN CONDITION FOR OPERATION 3.7.8 All h raulic and mechanical snubbers shall be OPERABLE.
APPLICABIL_
MODES 1, 2, 3, and 4. MODES 5 and 6 for snubbers located on s tems required OPERA LE in those OPERATIONAL MODES.
ACTION:
With one or more snubb s inoperable on any system, within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> repl e or restore the inoperable snubber(s) to ERABLE status and perform an engineering Valuation per Specification 4.7.8g. on the tached component or declare the attache systieminoperable and follow the appropriate ACTIO tatement for that system.
4.7.8 Each snubber shall be demons ted OPERABLE by--Pofrmance of the following augmented inservice inspection progra
- a.
Inspection Types As used in this specification, f snubber" shall mean snubbers of the same design and manufacturer espective of capacity,
- b.
Visual Inspections Snubbers are categoriz as inaccessib or accessible during reactor operation. Each of th se categories (inac ssible and accessible) may be inspected independ ntly according to the sc edule determined by Table 4.7-2.
The visual inspec on interval for each type of ubber shall be determined based upon the riteria provided in Table 4.7-?
d the first inspection interval determined u ng this criteria shall be based upon he previous inspection interval as tablished by the requirements in effect efore amendment 73
-,UNIT 3 3/4 7-21 AMENDMENT NO.£,-7-,89, to W3F1-2008-0059 Page 5 of 11 TABLE 4.7-2 SNUBBER VISUAL INSPECTION INTERVAL NUMBER OF UNACCEPTABLE SNUBBERS Po tion Column A Column B Column C or Cat ory Extend Interval Repeat Interval Reduce Interv (Notes
& 2) (Notes 3 & 6)
(Notes 4 & 6)
(Notes 5 & 6).
1 0
0 1
80 0
0 2
100 0
1 4
150
- 0ý 3
200 2
5 300 5
12 400 a*
18 Soo 12 24 750 20 40 1000 or greater 21\\
16 Note 1:
The next visual in ection interval fo ea snubber population or catgoy size: shal1,*-determined ba d-upon.the previous inspection interval and the numb of unaccep a1e snubbers found during that interval.
Snubber ma be categoryzed, based upon their accessibility during Opera on, as accessible or inaccessible.
These categories may be e in separately or jointly.
- However, the licensee eust make and nt that decision before any inSpectiOn and shall use tha decision as the basis upon which to determine the next inspacti terval for that category.
Note 2:
Interpolation between p lation r category sizes and the nuber of unacceptable snubbers i permissib Use next lower integer for the value of the limi for Columns B, or C if that integer includes a fractions value of unacce le snubbers as determined by interpolation.
Note 3:
If the number of nacceptable snubber is ual to or less than the numer in Cal A, the next inspection in rval may be twice the previous into al but not greater than 48 mo s.
wATERF0jt-UNIT 3 3/4 7-23.a ANSOWEN No. 73 to W3F1 -2008-0059 Page 6 of 11 TABLE 4.7-2 (Continued)
SNUBBER VISUAL INSPECTION INTERVAL Note 4:
f the number of unacceptable snubbers is equal to or less tha the mn r in Column B but greater than the number in Column A, e
no t inspection interval shall be the same as the previous *terval.
Note 5:
If th number of unacceptable snubbers is equal to or gr ter than the number in Column C, the next inspection interval shall two-thirds of the evious interval.
However, if the number of u acceptable snubbers *s less than the number in Column C but gre er than the number in lumn B, the next interval shall be redu d proportionally by interpol ion, that is, the previous interval s all be reduced by a factor that is one-third of the ratio of the d ference between the number of unac ptable snubbers found during th previous interval and the number in C umn B to the difference in t numbers in Columns B and C.
Note 6:
The provisions of SIN tion intervals up to licable for all inspec-WATERFORD - UNIT 3 3/4 7-21b AMENDMENT NO - 73 to W3FI -2008-0059 Page 7 of 11
\\'LANT SYSTEMS SU ILLANCE REQUIREMENTS (Continued)
C.
Visual Inspection Acceptance Criteria isual inspections shall verify that (1) the snubber has no visible idications of damage or impaired OPERABILITY, (2) attachme s to the fo dation or supporting structure are functional, and (3) fasteners for he attachment of the snubber to the component and t the snubber ancho ge are functional.
Snubbers which appear ioper le as a result f visual inspections shall be classified as u cceptable and may be r classified acceptable for the purpose of es hlishing the next visu inspection interval, provided that (1),ne cause of rejec-tion is cl rly established and remedied for that iarticular snubber and for othe snubbers irrespective of type that/ ay be generically susceptible; d (2) the affected snubber is f cttonally.tested in the as-found co dition and determined OPERABL per Specifica-ti.on.4.7..8f..... Al. snubbers.found. connected t an. inoperable common...
hydraulic fluid re ervoir shall be counted s unacceptable for determining the nex inspection interval./ A review and evaluation shall be performed an documented to ju ify continued operation with an unacceptable snubbe If continued/t peration cannot be justified, the snubber shall be de ared inoper e and the ACTION requirements shall be met.
- d.
Transient Event Inspection An inspection shall be perfo of all hydraulic and mechanical snubbers attached to section of ysteus that have experienced unexpected, potentially d gi-ng ansients as determined from a review of operation~al dat and a vi al inspection of the systems within 6 months'follomwin such an ev t. In addition to satisfying the visual inspection ceptance crite ia, freedom-of-motion of mechanical snubbers s 11 be verified u 'ng at least one of the following: (1) man ly induced snubber vement; or (2) evaluation of in-place snubber piston setting; or (3) troking the mechanical snubber through i full range of travel.
UNIT 3 3/4 7-22 AMENDMENT NO.
to W3F1 -2008-0059 Page 8 of 11 PATSYSTEM$ 5 SR LLANCE REQUIREMENTS (Continued)
"e.
Functional-Tests
/
uring the first refueling shutdown and at least once per 18 m ths t reafter during shutdown, a representative sample of snubbe s shall be ested using one of the following sample plans.
The sam e plan shal be selected prior to the test period and cannot be c anged during the t t period.
The NRC Regional Administrator shall b notified in writing f the sample plan selected prior to the test p iod or the sample p n used in the prior test period shall be im emented:
- 1) At lea 10% of the total of each type of snub er shall be func-tionall tested either in-place or in a benc test.
For each snubber o a type that does not meet the fu tional test accept-ance crite a of Specification 4.7.8f., a additional 10% of that type of snub er shall be functionally te ed until no more failures are. found or.
Mti...al..
snubbers of t...that ype ha.ve.. been. functional ly tested; or
- /
- 2)
A representative mple of each typ of snubber shall be func-tionally tested in cordance wit Figure 4.7-1.
"C" is the total number of snub rs of a ty e found not meeting the accep-tance requirements of ecific ion 4.7.8f.
The cumulative number of snubbers of a ype ested is denoted by "N".
At the end of each days testin e new values of "N",and "C" (pre-vious day's total plus cur nt'day's increments) shall be plotted on Figure 4.7-1.
at any time the point plotted falls in the "Reject".r ion 11 snubbers of that type shall be functionally tested.
at an time the point plotted falls in the "Accept" region, esting o ubbers of that type may be terminated. When t point plott lies in the "Continue Test-ing" region, addi onal snubbers o that type shall be tested until the point Ils in the "Accept region or the "Reject" region, or all he snubbers of that e have been tested..
Test-ing equipment iailure during functional esting may invalidate that day's t sting and allow that day's sting to resume anew at later ime, providing all snubbers te ed with the failed equipme:n during the day of equipment failu are retested; or
- 3)
An mi al representative sample of 55 snubber shall be function-ally ested.
For each snubber type which does n t meet the func-tio 1 test acceptance criteria, another Sample o at least one-h fthe size of the initial sample shall be teste until the total mber tested is equal to the initial sample size mu tiplied by the factor, 1 + C/2, where "C" is the number of snubbers und which do not meet the functional test acceptance criteria.
e results from this sample plan shall be plotted using an "Accept" ine which follows the equation N = 55(1 + C/2).
Each snubber point hould be plotted as soon as the snubber is tested.
If the point lotted falls on or below the "Accept" line, testing of that type of nubber may be terminated. If the point plotted falls above the "
Acce t line, testing must continue until the point falls in the "Accep region or all the snubbers of that type have been tested.
ATERFORO UNIT 3 3/4 7-23 to W3F1 -2008-0059 Page 9 of 11 SUR ILLANCE REQUIREMENTS (Continued) ehThe representative sample selected for the functional test samp
- lans shall be randomly selected from the snubbers of each typ and
- viewed before beginning the testing.
The review shall ensure as
~ fa ras practical that they are representative of the variou /con-fig ations, operating environments, range of size, and c acity of snubbers of each type.
Snubbers placed in the same loca ons as snubbe Ks which failed the previous functional test shal/ be retested at the
- ~me of the next functional test but shall not/ e included in the sampl, plan.
If during the functional testing, idditional sampling i~k required due to failure of only one ty* of snubber, the functional tsting results shall be reviewed at t
e time to deter-mine if addit onal samples should be limited to the type of snubber which has fail the functional testing..
w f
- f.
Fn The snu ber funtion 1 tes t sa ll vei fy at:
- 1) Ac i at o ( e tr iing a t o ) i chieved within the specified range in both tensf nand compre sion;
- 2)
Snubber bleed, or rel se rat Zwhere required, is present in both tension and compre Rsion, "within the specified range;
- 3)
Where required, the force equired to initiate or ma'intain motion of the snubber i iwi ~in the specified range in both directions of travel;d
- 4)
For snubbers specif /ally requi dnoN~
t to displace under c o n t i n u o u s l o a d, to el a blit y o f t h e s n u b b e r t o w i t h s t a n d l o a d without displace }nt.
Testing methodst ma ye used to measure pa rt e
vershindirectly or parameters other *an those specified if tho e results can be correlated to hspecified parameters throug established methods.
g.~~~~e Fucioa Te~
aslrAayi An enginee g evaluation shall be made of each fal ure to meet the function test acceptance criteria to determine the~ ause of the
~failure/
The results of this evaluation shall be use(*
if applicable, in sel cting snubbers to be tested in an effort to dete
'nine the
- OPER BILITY of other snubbers irrespective of type which ay be s
u pect to the same failu re mod e.
"c r the snubbers found inoperable, an engineering evaluationmhall
//be performed on the components to which the inoperable snubber are Sattached.
The purpose of this engineering evaluation shall be to determine if the components to which the inoperable snubbers are S attached were adversely affected by the inoperability of the s nubbs s in order to ensure that the component remains capable of meeting the designed service.
fATERFORD UNIT 33/4 7-24 to W3F1 -2008-0059 Page 10 of 11 XIANT SYSTEMS SURý&ILLANCE REQUIREMENTS (Continued)/
- If any snubber selected for functional testing either fails to/
- ]ock up or fails to move, i.e., frozen-in-place, the cause will be e
eluated and if caused by manufacturer or design deficiency I
sn bers of the same type subject to the same defect shall b func-tion ly tested.
This testing requirement shall be indepe ent of the re uirements stated in Specification 4.7.8e. for snub ers not meeting he functional test acceptance criteria.
- h.
Funct t _n al actin g nf R pnairpd and R pnla c~
d _Sn ijhhPr s Snubbers which fail the visual inspection or the f nctional test acceptance crit ia shall be repaired or replace.
Replacement snubbers and snub rs which have repairs which ght affect the functional test re t shall be tested to meet the functional test criteria before inst lation in the unit. M hanical snubbers shall
........ have met the acceptanc criteriasubsequent o their most-recent.
service, and the freedo of-motion test m t have been performed within 12 months before b ing installed
- the unit.
- i.
Snubber Seal Replacement Pro am The service life of hydraulic a chanical snubbers shall be moni-tored to ensure that the service fe is not exceeded between sur-veillance inspections.
The maxi umexpected service life for various seals, springs, and other crita('al p ts shall be determined and established based on engineering infor tion and shall be extended or shortened based on monit ed test re lts and failure history.
Critical parts shall be re aced so that e maximum service life will not be exceeded during a eriod when the sn bber is required to be OPERABLE.
The parts re* acements shall be d umented and the docu-mentation shall be re med in accordance wit pecification 6.10.3.
UNIT 3 3/4 7-25 to W3F1-2008-0059 Page 11 of 11 10 9
8 7
.6 C
5 4
3 2
1 SAMPLING PLAN FOR SNUBBER FUNCTIONAL TEST To W3FI-2008-0059 Revised Technical Specification Pages to W3F1 -2008-0058 Page 1 of 3 3/4 LIMITING CONDITIONS FOR OPERATION AND SURVEILLANCE REQUIREMENTS 3/4.0 APPLICABILITY LIMITING CONDITION FOR OPERATION 3.0.1 Compliance with the Limiting Conditions for Operation (LCO) contained in the succeeding specifications is required during the OPERATIONAL MODES or other conditions specified therein except as provided in LCO 3.0.2 or 3.0.8; or except that upon failure to meet the Limiting Conditions for Operation, the associated ACTION requirements shall be met.
3.0.2 Noncompliance with a specification shall exist when the requirements of the Limiting Condition for Operation and/or associated ACTION requirements are not met within the specified time intervals. If the Limiting Condition for Operation is restored prior to expiration of the specified time intervals, completion of the ACTION requirements is not required.
3.0.3 When a Limiting Condition for Operation is not met, except as provided in the associated ACTION requirements, within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />, action shall be initiated to place the unit in a MODE in which the specification does not apply by placing it, as applicable, in:
- 1.
At least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />,
- 2.
At least HOT SHUTDOWN within the following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />, and
- 3.
At least COLD SHUTDOWN within the subsequent 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.
Where corrective measures are completed that permit operation under the ACTION requirements, the ACTION may be taken in accordance with the specified time limits as measured from the time of failure to meet the Limiting Condition for Operation.
Exceptions to these requirements are stated in the individual specifications.
This specification is not applicable in MODE 5 or 6.
3.0.4 Entry into an OPERATIONAL MODE or other specified condition shall not be made when the conditions for the Limiting Conditions for Operatiorare not met and the ACTION requires a shutdown if they are not met within a specified interval. Entry into an OPERATIONAL MODE or specified condition may be made in accordance with' ACTION requirements when conformance to them permits continued operation of the facility for an unlimited period of time. Applying this exception shall be subject to review and approval as described in plant administrative controls unless the individual specification contains an exception to these requirements. This provision shall not prevent passage through or to OPERATIONAL MODES as required to comply with ACTION statements.
3.0.5 Equipment removed from service or declared inoperable to comply with ACTIONS may be returned to service under administrative control solely to perform testing required to demonstrate its OPERABILITY or the OPERABILITY of other equipment. This is an exception to LCO 3.0.2 for the system returned to service under administrative control to perform the testing required to demonstrate OPERABILITY.
WATERFORD - UNIT 3 3/4 0-1 Amendment No..99,404, to W3F1 -2008-0058 Page 2 of 3 3/4 LIMITING CONDITIONS FOR OPERATION AND SURVEILLANCE REQUIREMENTS 3/4.0 APPLICABILITY (continued)
LIMITING CONDITION FOR OPERATION 3.0.6 To be used later.
3.0.7 To be used later.
3.0.8 When one or more required snubbers are unable to perform their associated support function(s), any affected supported LCO(s) are not required to be declared not met solely for this reason if risk is assessed and managed, and:
- a.
the snubbers not able to perform their associated support function(s) are associated with only one train or subsystem of a multiple train or subsystem supported system or are associated with a single train or subsystem supported system and are able to perform their associated support function within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />; or
- b.
the snubbers not able to perform their associated support function(s) are associated with more than one train or subsystem of a multiple train or subsystem supported system and are able to perform their associated support function within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.
At the end of the specified period the required snubbers must be able to perform their associated support function(s), or the affected supported system LCO(s) shall be declared not met.
WATERFORD - UNIT 3 3/4 0-1 a Amendment No.
to W3F1 -2008-0058 Page 3 of 3 PLANT SYSTEMS SURVELLIANCE REQUIREMENTS
- c.
After every 720 hours0.00833 days <br />0.2 hours <br />0.00119 weeks <br />2.7396e-4 months <br /> of charcoal adsorber operation by verifying within 31 days after removal that a laboratory analysis of a representative carbon sample obtained in accordance with Regulatory Position C.6.b of Regulatory Guide 1.52, Revision 2, March 1978, shows the methyl iodide penetration less than 0.5%
when tested in accordance with ASTM D3803-1989 at a temperature of 300C and a relative humidity of 70%.
- d.
At least once per 18 months by:
- 1.
Verifying that the pressure drop across the combined HEPA filters and charcoal adsorber banks is less than 7.8 inches water gauge while operating the system at a flow rate of 3000 cfm +/- 10%.
- 2.
Verifying that the system starts on a Safety Injection Actuation. Test Signal and achieves and maintains a negative pressure of _ 0.25 inch water gauge within 45 seconds.
- 3.
Verifying that the filter cooling bypass valves can be manually cycled.
- 4.
Verifying that the heaters dissipate 20 + 2.0, -2.0 kW when tested in accordance with ANSI N510-1975.
- e.
After each complete or partial replacement of a HEPA filter bank by verifying that the HEPA filter banks remove greater than or equal to 99.95% of the DOP when they are tested in-place in accordance with ANSI N510-1975 while operating the system at a flow rate of 3000 cfm +/- 10%.
- f.
After each complete or partial replacement of a charcoal absorber bank by verifying that the charcoal adsorbers remove greater than or equal to 99.95% of a halogenated hydrocarbon refrigerant test gas when they are tested in-place in accordance with ANSI N510-1975 while~operating the system at a flow rate of 3000 cfm +/- 10%.
WATERFORD - UNIT 3 3/4 7-20 AMENDMENT NO. 4-7-0,1-94, Next Page is 3/4 7-27 To W3F1-2008-0059 List of Regulatory Commitments to W3F1 -2008-0059 Page 1 of 1 LIST OF REGULATORY COMMITMENTS The following table identifies those actions committed to by Entergy in this document. Any other statements in this submittal are provided for information purposes and are not considered to be regulatory commitments.
COMMITMENT TYPE SCHEDULED (Check one)
COMPLETION DATE ONE-TIME CONTINUING ACTION COMPLIANCE Entergy will establish the Technical
,/
To be Specification (TS) Bases for Limiting implemented in Condition for Operation (LCO) 3.0.8 as conjunction with adopted with the applicable license the amendment amendment.
Entergy 'Will ensure, during the relocation of
/
To be the TS 3.7.8 snubber requirements to the implemented in Technical Requirements Manual, that the conjunction with TRM Actions are modified, in accordance with the amendment 10 CFR 50.59, to require a record of the design function of the inoperable snubber (i.e.,
seismic vs. non-seismic), implementation of any Tier 2 restrictions each time a required snubber is rendered inoperable and the associated plant configuration.
Entergy will revise plant procedures or V
Prior to or in administrative process to ensure seismic risks conjunction with are considered during application of the implementation LCO 3.0.8 delay period when one or more of the snubbers are inoperable, amendment To W3F1-2008-0059 Proposed Technical Specification Bases Changes (for information only) to W3F1 -2008-0059 Page 1 of 3 BASES When a shutdown is required to comply with ACTION requirements, the provisions of Specification 3.0.4 do not apply because they would delay placing the facility in a lower MODE of operation.
Specification 3.0.5 establishes the allowance for restoring equipment to service Under administrative controls when it has been removed from service or declared inoperable to comply with ACTIONS. The sole purpose of this Specification is to provide an exception to Specification 3.0.2 (e.g., to not comply with the applicable Required Action(s)) to allow the performance of Surveillance Requirements to demonstrate:
- a.
The OPERABILITY of the equipment being returned to service; or
- b.
The OPERABILITY of other equipment.
The administrative controls ensure the time the equipment is returned to service in conflict with the requirements of the ACTIONS is limited to the time absolutely necessary to perform the allowed Surveillance Requirements. This Specification does not provide time to perform any other preventive or corrective maintenance.
An example of demonstrating the OPERABILITY of the equipment being returned to service is reopening a containment isolation valve that has been closed to comply with Required Actions and must be reopened to perform the Surveillance Requirements.
An example of demonstrating the OPERABILITY of other equipment is taking an inoperable channel or trip system out of the tripped condition to prevent the trip function from occurring during the performance of a Surveillance Requirement on another channel in the other trip system. A similar example of demonstrating the OPERABILITY of other equipment is taking an inoperable channel or trip system out of the tripped condition to permit the logic to function and indicate the appropriate response during the performance of a Surveillance Requirement on another channel in the same trip system.
Specification 3.0.8 LCO 3.0.8 establishes conditions under which systems are considered to remain capable of performing their intended safety function when associated snubbers are not capable of providing their associated support function(s). This LCO states that the supported system is not considered to be inoperable solely due to one or more snubbers not capable of performing their associated support function(s). This is appropriate because a limited length of time is allowed for maintenance, testing, or repair of one or more snubbers not capable of performing their associated support function(s) and appropriate compensatory measures are specified in the snubber requirements, which are located outside of the Technical Specifications (TS) under licensee control. The snubber requirements do not meet the criteria in 10 CFR 50.36, and, as such, are appropriate for control by the licensee.
If the allowed time expires and the snubber(s) are unable to perform their associated I
support function(s), the affected supported system's LCO(s) must be declared not met and the ACTIONS entered in accordance with LCO 3.0.2.
WATERFORD - UNIT 3 B 3/4 0-4 AMENDMENT NO. 62,,-1-04 Changed by letter dated August-22,4QQ0 CHANGE NO. 3G, to W3F1 -2008-0059 Page 2 of 3 BASES LCO 3.0.8.a applies when one or more snubbers are not capable of providing their associated support function(s) to a single train or subsystem of a multiple train or subsystem supported system or to a single train or subsystem supported system. LCO 3.0.8.a allows 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> to restore the snubber(s) before declaring the supported system inoperable. The 72-hour allowed outage time (AOT) is reasonable based on the low probability of a seismic event concurrent with an event that would require operation of the supported system occurring while the snubber(s) are not capable of performing their associated support function and due to the availability of the redundant train of the supported system.
LCO 3.0.8.b applies when one or more snubbers are not capable of providing their associated support function(s) to more than one train or subsystem of a multiple train or subsystem supported system. LCO 3.0.8.b allows 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> to restore the snubber(s) before declaring the supported system inoperable. The 12-hour AOT is reasonable based on the low probability of a seismic event concurrent with an event that would require operation of the supported system occurring while the snubber(s) are not capable of performing their associated support function.
LCO 3.0.8 requires that risk be assessed and managed. Industry and NRC guidance on the implementation of 10 CFR 50.65(a)(4) (the Maintenance Rule) does not address seismic risk. However, use of LCO 3.0.8 should be considered with respect to other plant maintenance activities, and integrated into the existing Maintenance Rule process to the extent possible so that maintenance on any unaffected train or subsystem is properly controlled, and emergent issues are properly addressed. The risk assessment need not be quantified, but may be a qualitative awareness of the vulnerability of systems and components when one or more.
snubbers are not able to perform their associated support function.
LCO 3.0.8 does not apply to non-seismic snubbers. The provisions of LCO 3.0.8 are not to be applied to supported TS systems unless the supported systems would remain capable of performing their required safety or support functions for postulated design loads other than seismic loads.
The risk impact of dynamic loadings other than seismic loads was not assessed as part of the development of LCO 3.0.8. These shock-type loads include thrust loads, blowdown loads, water-hammer loads, steam-hammer loads, LOCA loads and pipe rupture loads.
However, there are some important distinctions between non-seismic (shock-type) loads and seismic loads which indicate that, in general, the risk impact of the out-of-service snubbers is smaller for non-seismic loads than for seismic loads. First, while a seismic load affects the entire plant, the impact of a non-seismic load is localized to a certain system or area of the plant. Second, although non-seismic shock loads may be higher in total force and the impact could be as much or more than seismic loads, generally they are of much shorter duration than seismic loads. Third, the impact of non-seismic loads is more plant specific, and thus harder to analyze generically, than for seismic loads. For these reasons, every time LCO 3.0.8 is applied, at least one train (or subsystem) of each system that is supported by the inoperable snubber(s) should remain capable of performing their required safety or support functions for postulated design loads other than seismic loads.
WATERFORD - UNIT 3 B 3/4 0-4a AMENDMENT NO. 404 CHANGE NO.,-3 to W3F1 -2008-0059 Page 3 of 3 BASES
-+(DRN 03-1807, Ch. 30)
Specification 4.0.1 throuqh 4.0.4 establish the general requirements applicable to Surveillance Requirements. These requirements are based on the Surveillance Requirements stated in the Code of Federal Regulations, 10 CFR 50.36(c)(3):
4+-(DRN 03-1807, Ch. 30)
"Surveillance requirements are requirements relating to test, calibration, or inspection to ensure that the necessary quality of systems and components is maintained, the facility operation will be within safety limits, and that the limiting condition of operation will be met."
WATERFORD - UNIT 3 B 3/4 0-4b AMENDMENTNO.