ML082630563

From kanterella
Jump to navigation Jump to search
Errata to Affidavit of John F. Orourke Dated June 11, 2008
ML082630563
Person / Time
Site: Oyster Creek
Issue date: 09/12/2008
From: Kuyler R
AmerGen Energy Co, Morgan, Morgan, Lewis & Bockius, LLP
To: Abramson P, Anthony Baratta, Hawkens E
Atomic Safety and Licensing Board Panel
SECY RAS
References
50-219-LR, RAS H-66
Download: ML082630563 (6)


Text

DOCKETED UNITED STATES OF AMERICA USNRC NUCLEAR REGULATORY COMMISSION September 12, 2008 (4:22pm)

ATOMIC SAFETY AND LICENSING BOARD OFFICE OF SECRETARY RULEMAKINGS AND Before Administrative Judges:

ADJUDICATIONS STAFF E. Roy Hawkens, Chair Dr. Paul B. Abramson Dr. Anthony J. Baratta In the Matter of:

))

AmerGen Energy Company, LLC

))

(License Renewal for Oyster Creek Nuclear

)

Generating Station)

))

September 12, 2008 Docket No. 50-219-LR ERRATA TO AFFIDAVIT OF JOHN F. O'ROURKE DATED JUNE 11, 2008 Counsel for AmerGen Energy Co., LLC ("AmerGen") hereby files these Errata to correct the Affidavit of John F. O'Rourke ("Affidavit") filed before the Commission on June 11, 2008.

. Table 1 of the Affidavit presented a bay-by-bay explanation of the rationale for what general area thicknesses are being used in the sand bed region for the base case for AmerGen's 3-D finite element analysis of the Oyster Creek Nuclear Generating Station drywell shell. The description of Bays 15 and 17 contained slightly incorrect values for three thickness values. The enclosed corrected page from the Affidavit shows, in "track-changes," the correct thickness values.

Respectfully submitted, onald

. Silverman, Esq.

Kathryn M. Sutton, Esq.

Alex S. Polonsky, Esq.

Raphael P. Kuyler, Esq.

MORGAN, LEWIS & BOCKIUS, LLP 1111 Pennsylvania Avenue, N.W.

Washington, DC 20004 Phone: (202) 739-5502 E-mail: dsilverman@(morganlewis.com DB1/62119296.1 oI~

E-mail: ksutton(lmorganlewis.com E-mail: apolonsky(&morganlewis.com E-mail: rkuyler(Zmorganlewis.com J. Bradley Fewell, Esq.

Associate General Counsel Exelon Corporation 4300 Warrenville Road Warrenville, IL 60555 Phone: (630) 657-3769 E-mail: Bradley.Fewell (&exeloncorp.com COUNSEL FOR AMERGEN ENERGY COMPANY, LLC Dated in Washington, D.C.

this 12th day of September 2008 DBI/62119296.1 2

This bay has close to nominal wall thickness above elevation 11 '-0"; therefore, the grid average of 1133 mils is used. Below 1 1'-0", similar to Bay 3, a representative thickness of the average between Bay 5 (1074 mils) and Bay 9 (993 mils) is used for the shell, thickness below elevation I '-0" (1034 mils).

This bay exhibits corrosion both above and below elevation 1 1'-0". Above 11'-0", the thickness is appropriately represented by the weighted average (one is a 49 point grid and the other is a 7 point grid) of the two internal grids (1074 mils). Below 1 1'-0", it was more appropriate to use the smaller of the two internal grid averages for the general shell thickness. This value is 993 mils.

This bay exhibits corrosion both above and below elevation 11 '-0". Therefore, the average of the internal grid measurements is used for the general shell thickness for the entire bay. This value is 860 mils (average of 822 and 898).

This bay also exhibits corrosion both above and below elevation 11 '-0". There are three internal grid measurements in this bay (two 49 point grids and one 7 point grid). The 7 point grid indicates no significant metal loss and appears to be an anomaly in this bay given that the other two grids indicate external corrosion. Therefore, the average of only the two 49 point internal grids is used for the general shell thickness for the entire bay.

This value is 907 mils.

This bay exhibits greater thicknesses above elevation 11'-0". Therefore, this bay is split and the weighted average of the two grids (one 49 point and one 7 point) is used for the thickness of the shell above 11'-0". This value is 1062 mils. Below 1 1'-0", similar to Bays 3 & 7, a representative thickness of the average between Bay 13 (907 mils) and Bay 17 (954-963 mils) is used for the shell thickness (9-34-935 mils).

This bay has two 49 point grids and a portion of a grid that is partially in Bay 17 and partially in Bay 19. Since this third grid is at the edge of the bay, it is not used to determine representative thickness of the bay. Of the remaining two grids, the majority of the area above elevation 11'-0" is best represented by the weighted average of the bottom of the grid closest to Bay 15 (Grid 17A) and the entire middle grid (Grid 17D). This value is 864-863 mils. Below 11'-0", Bay 17 has a trench similar to Bay 5. Measurements from the trench provide representative data for most of the sandbed region between elevations 8'- 11" and 11 '-0". Therefore, the average of the internal grid measurements in the trench area is used for the shell thickness below 1 1'-0". This value is 9-54-963 mils.

17 19 This bay exhibits corrosion both above and below elevation 11 '70". Therefore, the average of the internal grid measurements (three 49 point grids) is used for the shell thickness for the entire bay. This value is 826 mils.

DB 1/62119131.1 8

In accordance with 28 U.S.C. § 1746, I state under penalty of perjury that the factual statements and opinions I express in this affidavit are true and correct to the best of my personal knowledge and belief:

Joh

'Rourke Date

)BI/62119131.1 9

UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION ATOMIC SAFETY AND LICENSING BOARD Before Administrative Judges:

E. Roy Hawkens, Chair Dr. Paul B. Abramson Dr. Anthony J. Baratta In the Matter of:

AmerGen Energy Company, LLC

))

(License Renewal for Oyster Creek Nuclear

)

Generating Station)

).)

September 12, 2008 Docket No. 50-219-LR CERTIFICATE OF SERVICE I hereby certify that copies of "ERRATA TO AFFIDAVIT OF JOHN F. O'ROURKE DATED JUNE 11, 2008" were served this day upon the persons listed below, by e-mail and first class mail.

Secretary of the Commission*

U.S. Nuclear Regulatory Commission Attn: Rulemakings and Adjudications Staff One White Flint North 11555 Rockville Pike Rockville, Maryland 20852-2738 (E-mail: HEARINGDOCKET(anrc.gov)

Administrative Judge Paul B. Abramson Atomic Safety and Licensing Board Panel Mail Stop: T-3 F23 U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 (E-mail: pba(qnrc.gov)

Administrative Judge E. Roy Hawkens, Chair Atomic Safety and Licensing Board Panel Mail Stop: T-3 F23 U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 (E-mail: erh(a3,nrc.gov)

Administrative Judge Anthony J. Baratta Atomic Safety and Licensing Board Panel Mail Stop: T-3 F23 U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 (E-mail: aib5( 1nrc. gov)

DBI/62119296.1

John A. Covino Valerie Anne Gray Division of Law Environmental Permitting and Counseling Section P.O. Box 093 Hughes Justice Complex Trenton, NJ 08625 (E-mail: john.covino(-dol.lps.state.ni.us)

(E-mail: valerie. gray(ad-dol.lps.state. ni.us)

Office of Commission Appellate Adjudication U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 (E-mail: OCAArnail(qnrc.gov)

Richard Webster Julia LeMense Eastern Environmental Law Center 744 Broad Street, Suite 1525 Newark, NJ 07102 (E-mail: rwebster(aeasternenvironrnental.org)

(E-mail: ilemense(aeasternenvironmental.or )

Mary C. Baty Kimberly A. Sexton Marcia J. Simon Office of the General Counsel, 0-15D21 U.S. Nuclear Regulatory Commission Washington, DC 20555 (E-mail: kas2Pnrc.gov)

(E-mail: mcb 1 (nrc. gov)

(E-mail: marcia. simon(q,,nrc. gov)

Original and 2 copies Paul Gunter Kevin Kamps Beyond Nuclear 6930 Carroll Avenue Suite 400 Takoma Park, MD 20912 (E-mail: paul(abeyondnuclear.org)

(E-mail: kevin(abeyondnuclear.org)

Emily Krause Law Clerk Atomic Safety and Licensing Board Mail Stop: T-3 F23 U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 (E-mail: eikl @nrc.gov)

RapVel P. Kuyler DBI/62119296.1 2