Technical Specifications, Issuance of Amendment Nos. 257 and 201 Regarding Editorial Revision to Standby Liquid Control Solution Figure
ML082590017
Person / Time
Site: Hatch  
Issue date: 09/23/2008
From:
Plant Licensing Branch II
To:
Martin, R E, NRR/DLPM, 301-415-1493
Shared Package
ML082340563 List:
References
TAC MD8616, TAC MD8617
Download: ML082590017 (4)


Text

257 257

(6)

Southern Nuclear, pursuant to the Act and 10 CFR Parts 30 and 70, to possess, but not separate, such byproduct and special nuclear materials as may be produced by the operation of the facility.

C. This renewed license shall be deemed to contain, and is subject to, the conditions specified in the following Commission regulations in 10 CFR Chapter I: Part 20, Section 30.34 of Part 30, Section 40.41 of Part 40, Section 50.54 of Part 50, and Section 70.32 of Part 70; all applicable provisions of the Act and the rules, regulations, and orders of the Commission now or hereafter in effect; and the additional conditions2 specified or incorporated below:

(1)

Maximum Power Level Southern Nuclear is authorized to operate the facility at steady state reactor core power levels not in excess of 2,804 megawatts thermal, in accordance with the conditions specified herein.

(2)

Technical Specifications The Technical Specifications (Appendix A) and the Environmental Protection Plan (Appendix B), as revised through Amendment No., are hereby incorporated in the renewed license. Southern Nuclear shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

(3)

Additional Conditions The matters specified in the following conditions shall be completed to the satisfaction of the Commission within the stated time periods following the issuance of the renewed license or within the operational restrictions indicated. The removal of these conditions shall be made by an amendment to the license supported by a favorable evaluation by the Commission.

(a)

Fire Protection Southern Nuclear shall implement and maintain in effect all provisions of the fire protection program, which is referenced in the the Updated Final Safety Analysis Report for the facility, as contained 2 The original licensee authorized to possess, use, and operate the facility was Georgia Power Company (GPC). Consequently, certain historical references to GPC remain in certain license conditions.

Renewed License No. NPF-5 Amendment No.

201 201

3.1.7 SLC System SPB Solution Volume VS. Concentration Requirements I (1716 gal, 13%) I 13 r----r---.=:=:::;==iiii 12 I----+---t---+-

11

'2 0

~

'0 =

(/)

10 C

m D.

(/)

i-

~

9 0

c 0.,..

IG 8

C -

CD tJ C

0 U

7 6I----+--+--+--+--+-----JI----+---+-_-+-_+-_+----t_~

5L.-----J._----L_--'--_...L.-_.l...-_'--------J._---'--_--'--_...L.-_"'-------J_---L._......L_....I.-----..,;~

1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 3200 3400 3600 3800 4000 4200 4400 4600 4800 Gross Volume of Solution Tank (gal)

Figure 3.1.7-1 (page 1 of 1)

Sodium Pentaborate Solution Volume Versus Concentration Requirements HATCH UNIT 1 3.1-20 Amendment No. 257

3.1.7 SLC System SPB Solution Volume vs. Concentration Requirements I (

I 1716 9al,13%)

13 C 0..

I

'0 en.:

m D.

en

~

0

~

c 0 ;;..-

cu c

eu u c 0

()

12 I---f---+--+_-

11 10 9

8 7

61----1f---+---+---+--+--+-----1--+--+--+--+--f------=:

S'----'-_---'--_--L.-_...J..-_"'----'_--'-_--'-_--L.-_...J..-_L.----'_--'-_-'--_-'------'

1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 3200 3400 3600 3800 4000 4200 4400 4600 4800 Gross Volume of Solution Tank (gal)

Figure 3.1.7-1 (page 1 of 1)

Sodium Pentaborate Solution Volume Versus Concentration Requirements HATCH UNIT 2 3.1-20 Amendment No. 201