Review of 2007 Steam Generator Tube Inservice Inspection Report
ML082480378
Person / Time
Site: Cook  American Electric Power icon.png
Issue date: 09/10/2008
From: Beltz T
Plant Licensing Branch III
To: Rencheck M
Indiana Michigan Power Co
beltz T, NRR/DORL/LPL3-1, 301-415-3049
References
TAC MD8396, TAC MD8397
Download: ML082480378 (5)


Text

September 10, 2008 Mr. Michael W. Rencheck Senior Vice President and Chief Nuclear Officer Indiana Michigan Power Company Nuclear Generation Group One Cook Place Bridgman, MI 49106

SUBJECT:

DONALD C. COOK NUCLEAR PLANT, UNITS 1 AND 2 - REVIEW OF THE STEAM GENERATOR TUBE INSERVICE INSPECTION REPORT (TAC NOS. MD8396 AND MD8397)

Dear Mr. Rencheck:

By letters dated March 18, and August 5, 2008, Indiana Michigan Power Company (I&M) submitted information pertaining to the year 2007 steam generator (SG) tube inspections at the Donald C. Cook Nuclear Plant (CNP), Units 1 and 2. No SG tube inspections were performed at CNP Unit 1 during 2007.

The U.S. Nuclear Regulatory Commission (NRC) staff has completed its review of these submittals and concludes that I&M provided the information required by the CNP Unit 2 Technical Specifications and that no additional follow-up is required at this time. The NRC staffs review report is enclosed. This completes the staff efforts for TAC Nos. MD8396 and MD8397.

If you have any questions regarding this matter, I can be contacted at 301-415-3049.

Sincerely,

/RA/

Terry A. Beltz, Senior Project Manager Plant Licensing Branch III-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-315 and 50-316

Enclosure:

Staff Evaluation cc: See next page

ML082480378 OFFICE LPL3-1/PM LPL3-1/PM LPL3-1/LA DE/EEEB/BC*

LPL3-1/BC NAME TBeltz PTam THarris AHiser*

LJames DATE 09/9 /08 09/ 10 /08 09/ 9 /08 09/02/08 09/ 10 /08

  • Evaluation transmitted by letter of 09/02/2008.

EVALUATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION DONALD C. COOK NUCLEAR PLANT, UNITS 1 AND 2 2007 STEAM GENERATOR TUBE INSERVICE INSPECTION REPORTS

1.0 INTRODUCTION

By letter dated March 18, 2007 (Agencywide Document Access and Management System (ADAMS) Accession No. ML080870429) Indiana Michigan Power Company (I&M, the licensee) submitted information pertaining to its 2007 steam generator (SG) tube inspections at the Donald C. Cook Nuclear Power Plant (CNP), Units 1 and 2. The licensee provided additional information regarding the SG tube inspections in a letter dated August 5, 2008 (ADAMS Accession No. ML082390706).

No SG tube inspections were performed at CNP Unit 1 during 2007.

2.0 BACKGROUND

The CNP Unit 2 has four Westinghouse Model 54F SGs which are designated SG21, SG22, SG23, and SG24. All four SGs were inspected during the 2007 refueling outage. The Westinghouse Model 54F SG consists of 3,592 thermally-treated Iconel 60 tubes with an outside diameter of 0.875 inches and a wall thickness of 0.050 inches. The tubes have been hydraulically expanded into the tubesheet and are supported by seven 1.12-inch-thick Type 405 stainless steel support plates which contain quatrefoil-shaped holes through which the tubes pass. The four CNP Unit 2 SGs commenced operation in 1989.

The licensee provided the scope, extent, methods, and results of their SG tube inspections in the documents referenced above. The licensee also described corrective actions (i.e., tube plugging) taken in response to the inspection findings. At the time of the inspection, CNP Unit 2 was in the first sequential inservice inspection period (144 Effective Full Power Months (EFPM)).

The SGs had operated 132.6 EFPM in the 144 EFPM period and a total of 146 EFPM.

3.0 EVALUATION After reviewing the information provided by the licensee, the U.S. Nuclear Regulatory Commission (NRC) staff made the following observations and comments:

Steam drum inspections were performed in SG22 and SG23 with a focus on the feedring header/supports, J-nozzles, and moisture separator units. In SG22, an area of minor surface pitting was found on the underside of the primary diffuser window. The licensee did not consider this condition abnormal or to be of concern to the functionality or integrity of the separator assembly. This area will be monitored in all SGs during future inspections.

In SG21, SG22, and SG24, some objects (sludge rocks and pieces of metal) were identified during a foreign object search and retrieval that were not able to be retrieved and were left in place. These items were documented and evaluated by the licensee to ensure that SG tube integrity would be maintained. The licensee plans to re-examine the non-sludge rock items in their next scheduled inspection outage.

Enclosure

4.0 CONCLUSION

S The NRC staff concludes that the licensee provided the information required by the CNP Unit 2 Technical Specifications. There are no technical issues that warrant follow-up action at this time since the inspections appear to be consistent with the objective of detecting potential tube degradation and the inspection results appear to be consistent with industry operating experience at similarly designed and operated units.

Principal Contributor: Emma Wong Kenneth Karwoski Dated: September 10, 2008

Donald C. Cook Nuclear Plant, Units 1 and 2 cc:

Attorney General Department of Attorney General 525 West Ottawa Street Lansing, MI 48913 Township Supervisor Lake Township Hall P.O. Box 818 Bridgman, MI 49106 U.S. Nuclear Regulatory Commission Resident Inspector's Office 7700 Red Arrow Highway Stevensville, MI 49127 James M. Petro, Jr.

Senior Nuclear Counsel Indiana Michigan Power Company One Cook Place Bridgman, MI 49106 Mayor, City of Bridgman P.O. Box 366 Bridgman, MI 49106 Special Assistant to the Governor Room 1 - State Capitol Lansing, MI 48909 John A. Zwolinski Regulatory Affairs Manager Indiana Michigan Power Company Nuclear Generation Group One Cook Place Bridgman, MI 49106 Michigan Department of Environmental Quality Waste and Hazardous Materials Div.

Radiological Protection Section Radiological Assessment Unit Constitution Hall, Lower-Level North 525 West Allegan Street P. O. Box 30241 Lansing, MI 48909-7741 Joel P. Gebbie, Plant Manager Indiana Michigan Power Company Nuclear Generation Group One Cook Place Bridgman, MI 49106 Lawrence J. Weber, Site Vice President Indiana Michigan Power Company Nuclear Generation Group One Cook Place Bridgman, MI 49106