of the Act and to the rules, regulations, and orders of the Commission now or hereafter in effect; and is subject to the additional conditions specified or incorporated below:

2.C.(1) Maximum Power Level Florida Power Corporation is authorized to operate the facility at a steady state reactor core power level not in excess of 2609 Megawatts (100 percent of rated core power level).

2.C.(2) Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 230, are hereby incorporated in the license. Florida Power Corporation shall operate the facility in accordance with the Technical Specifications.

The Surýeillance Requirements contained in the Appendix A Technical Specifications and listed below are not required to be performed immediately upon implementation of Amendment 149. The Surveillance Requirements shall be successfully demonstrated prior to the time and condition specified below for each.

a) SR 3.3.8.2.b shall be successfully demonstrated 'prior to entering MODE 4 on the first plant start-up following Refuel Outage 9.

b)

SR 3.3.11.2, Function 2, shall be successfully demonstrated no later than 31 days following the implementation date of the ITS.

c)

SR 3.3.17.1, Functions 1,2, 6, 10, 14, & 17 shall be successfully demonstrated no later than 31 days following the implementation date of the ITS.

d)

SR 3.3.17.2, Function 10 shall be successfully demonstrated prior to entering MODE 3 on the first plant start-up following Refuel Outage 9.

e)

SR 3.6.1.2 shall be successfully demonstrated prior to entering MODE 2 on the first plant start-up following Refuel Outage 9.

f)'

SR 3.7.12.2 shall be successfully demonstrated prior to entering MODE 2 on the first plant start-up following Refuel Outage 9.

g)

SR 3.8.1.10 shall be successfully demonstrated prior to entering MODE 2 on the first plant start-up following Refuel Outage 9.

h)

SR 3.8.3.3 shall be successfully demonstrated prior to entering MODE 4 on the first plant start-up following Refuel Outage 9.

Amendment No. 230

- 5c-2.C.(14)

Mitigation Strategy License Condition The licensee shall develop and maintain strategies for addressing large fires and explosions and that include the following key areas:

(1.)

Fire fighting responses strategy with the following elements:

a.

Pre-defined coordinated fire response strategy and guidance

b.

Assessment of mutual aid fire fighting assets

c.

Designated staging areas for equipment and materials

d.

Command and control

e.

Training of response personnel (2.)

Operations to mitigate fuel damager considering the following:

a.

Protection and use of personnel assets

b.

Communications

c.

Minimizing fire spread

d.

Procedures for implementing integrated fire response strategy

e.

Identification of readily-available pre-staged equipment

f.

Training on integrated fire response strategy

g.

Spent fuel pool mitigation measures (3.)

Actions to minimize release to include consideration of:

a.

Water spray scrubbing

b.

Dose to onsite responders 2.C.(15)

,Upon implementation of Amendment No230 adopting TSTF-448, Revision 3, the determination of control complex habitability envelope (CCHE) unfiltered a*ir inleakage as required by Surveillance Requirement (SR) 3.7.12.4, in

'accordance with ITS 5.6.2'21.3(i) and the assessment of CCHE habitability as required by ITS 5.6.2.21.3(ii), shall be considered met. Following implementation:

a)

The first performance of SR 3.7.12.4, in accordance with Specification 5.6.2.21.3(i), shall be within the specified Frequency of 6 years, plus the 18-month allowance of SR 3.0.2, as measured from May 18, 2007, the-date of the most recent successful inleakage test.

b)

The first performance of the periodic assessment of CCHE habitability, ITS 5.6.2.21.3(ii), shall be within 3 years, plus the 9-month allowance of SR 3.0.2, as measured from May 18, 2007, the date of the most recent successful inleakage test.

c)

The Control Complex Habitability Envelope Integrity Program will be used to verify the integrity of the Control Complex boundary.

Conditions that are identified to be adverse shall be trended and used as part of the 24 month assessment of the CCHE boundary. This assessment will be performed within 60 days of implementation of Amendment t

Amendment No. 230

- 5d-2.D Mitigation Strategy License Condition The licensee shall fully implement and maintain in effect all provisions of the Commission-approved physical security, training and qualification, and safeguards contingency plans including amendments made pursuant to provisions of the Miscellaneous Amendments and Search Requirements revisions to 10 CFR 73.55 (51 FR 27817 and 27822) and to the authority of 10 CFR 50.90 and 10 CFR 50.54(p).

The plans, which contain Safeguards Information protected under 10 CFR 73.21, are entitled: "Physical Security Plan, Revision 5," and "Safeguards Contingency Plan, Revision 4," submitted by letter dated May 16, 2006, and "Guard Training and Qualification Plan, Revision 0," submitted by letter dated September 30, 2004, as supplemented by letters dated October 20, 2004, and September 29, 2005.

Amendment No. 230

CREVS 3.7.12 3.7 PLANT SYSTEMS 3.7.12 Control Room Emergency Ventilation System (CREVS)

LCO 3.7.12 Two CREVS trains shall be OPERABLE.

NOTE----------------------

The control complex habitability envelope (CCHE) boundary may be opened intermittently under administrative control.

APPLICABILITY:.

MODES 1, 2, 3, and 4.

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.

One CREVS train A.1 Restore CREVS train 7 days inoperable for reasons to OPERABLE status.

other than Condition B.

B.

One or more CREVS B.1 Initiate action to Immediately trains inoperable due implement mitigating to inoperable CCHE actions.

boundary.

AND B.2 Verify mitigating 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> actions ensure CCHE occupant exposures to radiological,

chemical, and smoke hazards will not exceed limits.

AND B.3 Restore CCHE 90 days boundary to OPERABLE status.

(continued)

Crystal River Unit 3 3.7-24 Amendment No. 230

CREVS 3.7.12 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME C. Required Action and C.1 Be in MODE 3.

6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Time of Condition A AND or B not met.

C.2 Be in MODE 5.

36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> D. Two CREVS trains D.1 Enter LCO 3.0.3.

Immediately inoperable for reasons other than.

Condition B.

SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.7.12.1 Operate each CREVS train for 31 days

Ž 15 minutes.

SR 3.7.12.12 Perform required CREVS filter testing in In accordance accordance with the Ventilation Filter with the Testing Program.

Ventilation Filter Testing Program SR 3.7.12.3 Verify each CREVS train actuates to the 24 months emergency recirculation mode on an actual or simulated actuation signal.

SR 3.7.12.4 Perform required CCHE unfiltered air in-In accordance leakage testing in accordance with the with the Control Complex Habitability Envelope Control Integrity Program.

Complex Habitability Envelope Integrity' Program Crystal RiVer Unit 3 3.7-25 Amendment No. 230

Procedures, Programs and Manuals 5.6 5.6 Procedures, Programs and Manuals 5.6.2.21 Control Complex Habitability Envelope Integrity Program A Control Complex Habitability Envelope Integrity Program shall be established and implemented to ensure that CCHE habitability is maintained such that, with an OPERABLE Control Room Emergency Ventilation System (CREVS),

CCHE occupants can control the reactor safely under normal conditions and maintain it in a safe condition following a radiological event, hazardous chemical release, or a challenge from smoke.

The program shall ensure that adequate radiation protection is provided to permit access and occupancy of the CCHE under design basis accident (DBA) conditions without personnel receiving radiation exposures. in excess of 5 rem total effective dose equivalent (TEDE) for the duration of the accident.

The program shall include the following elements.

1. The definition of the CCHE and the CCHE boundary.

'2. Requirements for maintaining the CCHE boundary in its design condition including configuration control and preventive maintenance.

3. Requirements for (i) determining the unfiltered air in-leakage past the CCHE boundary into the CCHE in accordance with the testing methods and at the Frequencies specified in Sections C.1 and C.2 of Regulatory Guide 1.197,. "Demonstrating Control Room Envelope Integr.ity at Nuclear Power Reactors," Revision 0, May 2003, and (0i) assessing.CCHE habitabi.lity at the Frequencies specified in Sections C.1 and C.2 of Regulatory, Guide 1.197, Revision 0.
4. The Control Complex Habitability Envelope Integrity Program will be used to verify the integrity of the Control Complex boundary.

Conditions that are identified to be adverse shall be trended and used as part of the 24 month assessment of the CCHE boundary.

15. The quantitative limits on unfiltered air in-leakage into the CCHE.

These limits shall be stated in a manner to allow direct comparison to the unfiltered air in-leakage measured by the testing described in paragraph 3.

The unfiltered air in-leakage limit for radiological challenges is the in-leakage flow rate assumed in the licensing basis analyses of DBA consequences.

Unfiltered air in-leakage limits for hazardous chemicals and smoke must ensure that exposure of CCHE occupants to these hazards will be within the assumptions in the licensing basis.

6. The provisions of SR 3.0.2 are applicable to the Frequencies for assessing CCHE habitability, determining CCHE unfiltered in-leakage as required by paragraph 3.

Crystal River Unit 3 5.0-23B Amendment No. 230