License Termination Plan, Revision 1, Glossary of Terms, Acronyms and Abbreviations
ML081990504
Person / Time
Site: Rancho Seco
(DPR-054)
Issue date: 05/31/2008
From:
Sacramento Municipal Utility District (SMUD)
To:
NRC/FSME
References
MPC&D 08-060
Download: ML081990504 (6)


Text

Rancho Seco License Termination Plan Revision 1 Glossary of Terms, Acronyms and Abbreviations May 2008 Glossary of Terms Background Radiation - Radiation from cosmic sources, naturally occurring radioactive material, and global fallout, which contributes to the background radiation.

Containment Building - The building during plant operation that contained the reactor vessel, steam generators, pressurizer, reactor coolant pumps, and other systems.

Contamination - Deposition of reactor-generated radioactive material.

Corrective Action Records - Documentation for occurrences or events that recognized safety related deficiencies, identified conditions adverse to quality, or were reportable to regulatory agencies. Corrective action documentation includes evaluations, actions, results and responses that were associated with an event or condition that documented in License Event Reports (LERs), Occurrence Description Reports (ODRs), Non-Conformance Reports (NCRs), Potential Deviations from Quality (PDQ) or Deviation from Quality (DQ).

DCGL - (derived concentration guideline level) The derived radionuclide-specific activity concentration that corresponds to the release criterion (25mrem/y) within a survey unit.

Deterministic treatment - While using RESRAD-BUILD in the probabilistic mode, deterministic treatment is the assignment of a single conservative value to a parameter rather than a statistical distribution.

Health Physics Logbook - The logbook detailing the day-to-day site Health Physics activities.

Impacted Area - Any area that is not classified as non-impacted. Areas with a reasonable possibility of containing residual radioactivity in excess of natural background or fallout levels.

Industrial Area - The land area of potential radiological and non-radiological impact is that portion of the site where licensed activities took place. This location encompasses approximately 87 acres and includes the power block, the interim onsite radwaste storage building, and adjacent support structures and transport routes.

Independent Spent Fuel Storage Installation (ISFSI) - The area that contains the dry fuel storage facility.

Non-Impacted Area - An area where there is no reasonable possibility (extremely low probability) for residual radioactivity to exist.

pCi/g - Picocurie per gram, a concentration scale typically used in the measurement of radioactivity in soil.

Piezometer - A type of groundwater well used to measure differences in hydrostatic pressure in aquifers.

ix

Rancho Seco License Termination Plan Revision 1 Glossary of Terms, Acronyms and Abbreviations May 2008 PRCC - Partial ranked correlation coefficient - Estimates nonlinear monotonic relationship and gives the unique contribution of an input parameter to the resultant dose.

Residual Radioactivity - Radioactivity in structures, materials, soil, groundwater and other media at a site resulting from activities under the licensees control. This includes radioactivity from all licensed and unlicensed sources used by the licensee. It also includes radioactive materials remaining at the site as a result of routine or accidental releases. Residual radioactivity does not include background radiation from naturally occurring isotopes or fallout from nuclear bomb testing.

SAFSTOR - The alternative in which the nuclear facility is placed and maintained in a condition that allows the nuclear facility to be safely stored and subsequently decontaminated (deferred decontamination) to levels that permit release for unrestricted use.

Scoping Survey - An initial survey performed to evaluate: 1) radionuclide contaminants,

2) relative radionuclide ratios, and 3) general levels and extent of contamination.

Single nuclide DCGL - A radionuclide-specific activity concentration that would result in an annual total effective dose equivalent (TEDE) dose of 25 mrem with no other radionuclides present.

Stochastic treatment - While using RESRAD or RESRAD-BUILD in the probabilistic mode, stochastic treatment is the assignment of a statistical distribution for the value of a RESRAD or RESRAD-BUILD parameter.

Turbine Building - The building that once contained the condensate feed pumps, condensate demineralizers, moisture separators, feedwater heaters and main turbine generator.

Unity rule (mixture rule) - A rule applied when more than one radionuclide is present at a concentration that is distinguishable from background and where a single concentration comparison does not apply. In this case, the mixture of radionuclides is compared against default concentrations by applying the unity rule. This is accomplished by determining: 1) the ratio between the concentration of each radionuclide in the mixture, and 2) the concentration for that radionuclide in an appropriate listing of default values. The sum of the ratios for all radionuclides in the mixture should not exceed 1.

x

Rancho Seco License Termination Plan Revision 1 Glossary of Terms, Acronyms and Abbreviations May 2008 Acronym Table Acronym Description AEC Atomic Energy Commission AES Air Ejector System AF Area Factor ALARA As Low As Reasonably Achievable ANI American Nuclear Insurers ANSI American National Standards Institute AS Auxiliary Steam ASLB Atomic Safety and Licensing Board (NRC)

AUX Auxiliary AWJ Abrasive Water Jet bgs Below Ground Surface BOP Balance Of Plant BWST Borated Water Storage Tank CBS Containment Building Spray CCR California Code of Regulations CCW Component Cooling Water CDE Committed Dose Equivalent CDS Condensate System CEDE Committed Effective Dose Equivalent CEQA California Environmental Quality Act CFR Code of Federal Regulations Ci Curie cm Centimeters C of C Certificate of Compliance CRD Control Rod Drive System CST Condensate Storage Tank D&D Decontamination and Dismantlement DAW Dry Activated Waste DCGL Derived Concentration Guideline Level DMW Demineralized Water System DOE Department of Energy DOT Department of Transportation dpm Disintegrations per minute DQ Deviation from Quality DQOs Data Quality Objectives DSAR Defueled Safety Analysis Report DTS Defueled Technical Specifications ECCS Emergency Core Cooling System EGS Emergency Generator System EIS Environmental Impact Statement EMC Elevated Measurement Comparison EPA Environmental Protection Agency EPRI Electric Power Research Institute ER Environmental Report FCC Federal Communications Commission FGEIS Final Generic Environmental Impact Statement xi

Rancho Seco License Termination Plan Revision 1 Glossary of Terms, Acronyms and Abbreviations May 2008 Acronym Description FSS Final Status Survey FWS Feedwater System GEIS Generic Environmental Impact Statement GeLi Germanium - Lithium GPR Ground Penetrating Radar GPS Global Positioning System GTCC Greater Than Class C HAZMAT Hazardous Materials HEPA High Efficiency Particulate Absorber HLW High Level Waste HSA Historical Site Assessment HTD Hard-to-Detect HVAC Heating, Ventilating, and Air Conditioning HVS Ventilation Air System IAEA International Atomic Energy Agency I&C Instrument and Control IDCGL Initial Derived Concentration Guideline Level IOSB Interim On-Site (Radwaste) Storage Building ISFSI Independent Spent Fuel Storage Installation LAN Local Area Network LBGR Lower Boundary of the Gray Region LLRW Low-Level Radioactive Waste LLW Low-Level Waste LTP License Termination Plan MARSSIM Multi-Agency Radiation Survey & Site Investigation Manual MCW Main Circulating Water MDA Minimum Detectable Activity MDC Minimum Detectable Concentration MDCR Minimum Detectable Count Rate MDCRs Minimum Detectable Count Rate surveyor MDER Minimum Detector Exposure Rate MCC Motor Control Center msl Mean Sea Level MSS Main Steam System NAC Nuclear Assurance Corporation NaI Sodium - Iodide NIS Nuclear Instrumentation System NIST National Institute of Standards and Technology NMSS Nuclear Materials Security and Safeguards NOAA National Oceanographic and Atmospheric Administration NORM Naturally Occurring Radioactive Material NPDES National Pollutant Discharge Elimination System NRC Nuclear Regulatory Commission NSSS Nuclear Steam Supply System NWS National Weather Service ODCM Offsite Dose Calculation Manual xii

Rancho Seco License Termination Plan Revision 1 Glossary of Terms, Acronyms and Abbreviations May 2008 Acronym Description ODR Occurrence Description Report OJT On-the-Job Training OSHA Occupational Safety & Health Administration OTSG Once Through Steam Generator PAG Protective Action Guidelines PAP Personnel Access Portal PCP Process Control Program PDP Proposed Decommissioning Plan PDQ/DQ Potential Deviation from Quality/Deviation from Quality PE Plant Effluent P-o-M Peak of the Mean PPE Personal Protective Equipment ppm Parts Per Million PRCC Partial Ranked Correlation Coefficient PSDAR Post Shutdown Decommissioning Activities Report PZR Pressurizer QA/QC Quality Assurance/Quality Control QAPP Quality Assurance Project Plan QPD Quality Program Description RA Restricted Area RAI Request for Additional Information RB Reactor Building (or RCB Reactor Containment Building)

RCA Radiologically Controlled Area RCP Reactor Coolant Pump RCRA Resource Conservation Recovery Act RCS Reactor Coolant System RDM Radiation Monitoring System REM Radiation Equivalent Man REMP Radiological Environmental Monitoring Program RESRAD RESidual RADioactivity (Computer Code)

RESRAD-BUILD RESidual RADioactivity-BUILDing (Computer Code)

RETS Radiological Effluent Technical Specifications RHUT Regenerant Holdup Tank(s) (A, B, & C)

RP Radiation Protection RPD Relative Percent Difference RPV Reactor Pressure Vessel RWS Radwaste System Rx Reactor SAB Survey Area Block SAR Safety Analysis Report SD Storm Drain SDC Document Control Center SER Safety Evaluation Report SFP Spent Fuel Pool xiii

Rancho Seco License Termination Plan Revision 1 Glossary of Terms, Acronyms and Abbreviations May 2008 Acronym Description SSC Structures, Systems, or Components SMCM Subsurface Multispectral Contamination Monitor SMUD Sacramento Municipal Utility District SU Survey Unit SUID Survey Unit Identification Number SWS Service Water System SYS System TEDE Total Effective Dose Equivalent TLD Thermoluminescent Dosimeter TK Tank TRU Transuranic WGS Waste Gas System xiv