NRC 2008-0048, Technical Specification Bases Change Summary from January 1, 2007 Through June 30, 2008

From kanterella
(Redirected from ML081820650)
Jump to navigation Jump to search
Technical Specification Bases Change Summary from January 1, 2007 Through June 30, 2008
ML081820650
Person / Time
Site: Point Beach  
Issue date: 06/27/2008
From: Mccarthy J
Florida Power & Light Energy Point Beach
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NRC 2008-0048
Download: ML081820650 (6)


Text

FPL Energy Point Beach Nuclear Plant June 27,2008 FPL Energy Point Beach, LLC, 6610 Nuclear Road, Two Rivers, WI 54241 NRC 2008-0048 TS 5.5.1 3 10 CFR 50.71 (e)

U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 Point Beach Nuclear Plant, Units 1 and 2 Dockets 50-266 and 50-301 Renewed License Nos. DPR-24 and DPR-27 Technical Specification Bases Change Summary In accordance with the requirements of Technical Specification 5.5.1 3 and 10 CFR 50.71 (e),

FPL Energy Point Beach, LLC, is submitting changes made to the Point Beach Nuclear Plant (PBNP) Technical Specification Bases. contains the Technical Specification (TS) Bases change summary from January 1,2007, through June 30,2008.

This letter contains no new commitments and no revisions to existing commitments.

Very truly yours, FPL En Point Be ch, LLC 0

Enclosure

/

cc:

Administrator, Region Ill, USNRC Project Manager, Point Beach Nuclear Plant, USNRC Resident Inspector, Point Beach Nuclear Plant, USNRC PSCW An FPL Group company

ENCLOSURE I FPL ENERGY POINT BEACH, LLC POINT BEACH NUCLEAR PLANT, UNITS I AND 2 TECHNICAL SPECIFICATIONS BASES CHANGE

SUMMARY

Date of Affected Channe Section Summary 01/08/07 B3.1.4 In the last sentence of the Applicable Safety Analyses section, "Criterion 2 of the NRC Policy Statement" was changed to "Criterion 2 of 10 CFR 50.36(~)(2)(ii)."

In the first paragraph of the Actions section, a sentence was added to clarify the note is applicable to rods moved within one hour.

03/15/07 B 3.3.5 The requirements for operation of control room ventilation became applicable to only movement of irradiated fuel; applicability to core alterations was removed from Applicable Safety Analysis section, Applicability section and Actions section via Amendments 2241230.

B 3.6.6 Throughout the Background section generic references to release limits and DBA transient were replaced with the phrase "LOCA or SLB."

Specific descriptions of LOCA and SLB were added to the Background section.

The Applicable Safety Analysis section was rewritten to specifically address LOCA and SLB events.

The changes resulted in the addition of several pages, and page renumbering, to the Basis document.

B 3.7.2 The second paragraph of Applicable Safety Analyses section was changed to identify the containment pressure that would be reached by analysis, and statement of the containment pressure limit.

The final sentence of Applicable Safety Analysis section was changed to include a 10 CFR 50.36 subsection reference rather than an NRC policy statement number.

Section SR 3.7.2.1 had the specific MSlV stroke time value replaced by a reference to the ASME code-based inservice testing program via License Amendments 2301235.

The References section was changed to clarify that OM Code is part of ASME Boiler and Pressure Vessel Code, the reference for NUREG-800 was removed, and reference to TM 4.7, lnservice Testing Program was added.

Page 1 of 5

Date of Affected Change Section B 3.7.3 The second paragraph of Applicable Safety Analyses was changed to identify the containment pressure that would be reached by analysis, and statement of the containment pressure limit.

A paragraph was added that identifies the need to perform a safety function determination program (SFDP) review, and that the SFDP must consider containment spray and containment fan cooler operability. This same paragraph was added to the LC0 section.

B 3.7.9 In the Actions section, the action B.4 was removed, reflecting Amendments 2241230 to the Technical Specifications. Also, the term "Core Alterations" was removed as the Specification only applies during movement of irradiated fuel.

B 3.8.4 In the Background section, fourth paragraph, the reference to Safety lnjection Reset, has been removed because it does not apply.

In the Background section, beginning on Page 2, the value of battery voltage is removed and a corrected FSAR reference included with figure numbers removed.

The second paragraph of the Surveillance Requirements section on Page 8 has had details of the surveillance testing removed.

B 3.8.9 In the Background section, Page 2, sixth paragraph, the reference to Safety Injection Reset, has been removed because it does not apply.

B 3.8.10 For the first paragraph of the Actions section, the specific limitations of applicability to Core Alterations and fuel movement are removed as a result of Amendments 2241230. Applicability is as specified in the Technical Specifications.

B 3.9.1 In the Actions section, removed reference to Action A.2 as it was deleted from Technical Specifications. Also the reference to Core Alterations due to Amendments 2241230 was removed.

B 3.9.2 Throughout the Action section, removed the reference to Core Alterations due to Amendments 2241230.

B 3.9.3 Page 2 was revised for typographical change and relocation of a revision bar from left to right margin.

In the Actions section, the reference to Action A.2 was removed as it no longer applies.

Page 2 of 5

Date of Affected Chan~e Section Summarv B 3.9.6 Throughout the document, removed the term "Core Alterations" because Amendments 2241230 removed the condition of applicability.

04/07/07 B 3.3.4 Title changed to delete "Load Sequence" and clearly identify that starting instrumentation only is addressed; references to undervoltage and degraded voltage are removed throughout the Bases.

The value for loss of voltage was changed.

The Background section was changed to explain how degraded voltage conditions initiate emergency diesel generator operation.

An enhanced functional description of setpoints and logic was added.

In the Allowable Values portion of Background section, the reference to the FSAR as a source has been replaced by electrical system analyses. Also, the surveillance requirement setpoint source is the electrical system analyses.

The Applicable Safety Analyses section has been changed to identify the system design is based on GDC 39, the impacts of individual components on system performance is deleted, and the NRC policy statement reference is replaced by the applicable 10 CFR 50.36 criterion.

In the Surveillance Requirement section for SR 3.3.4.3, the frequency changed from refueling to every 18 months, clarified the instrument loop by excluding the potential transformer sensor, and added a paragraph describing time delays.

04/30107 B 3.6.3 Changes throughout Bases to reflect the elimination of the inside containment valve as a containment isolation valve (CIV). Outside containment valve retained as CIV. Applicable to both Units 1 and 2 as physical modifications were completed.

B 3.9.3 Changes made throughout Bases to reflect the elimination of inside containment valve as a CIV. The outside containment valve retained as CIV. Applicable to both Units 1 and 2 as physical modifications have been completed.

06125107 B 3.8.1 Background section, second paragraph on Page 5, replaced "full load" with "design basis accident loads."

Background section, sixth paragraph, fan air temperature limit was lowered to 80° F.

Page 3 of 5

Date of Affected Channe Section Summary In Background section, the ASME Code changed to Section XI from Section Ill.

In Applicable Safety Analysis section "NRC Policy Statement" changed to 10 CFR 50.36 criterion.

In Reference section, added one calculation and changed ASME code number.

In Surveillance Requirements section, for MSlV testing, removed specific time value and details on timing; replaced by reference number as a result of Amendments 2301235.

In References section, ASME code name made formal and added reference to TRM 4.7.

In LC0 section, ltem a., added "or" between two paragraphs.

In LC0 section, ltem a., added "or" between two paragraphs.

All locations of steam generator narrow range surveillance limit were reduced to 35%.

All locations of pressurizer high and low-level indication values changed.

All locations of accumulator level indication values changed.

All locations of RWST volume limit (level value) changed.

All locations of indicated CST level limits changed.

In Background section, the maximum rod position deviation allowed changed from units of inches to rod steps.

All occurrences of high acceptable pH value changed to 10.5.

In the Background and LC0 sections, added the identification of Purge Supply and Exhaust System inside containment blind flanges as part of the containment boundary.

In the Reference section, added NRC SE for Amendments 2311236 associated with blind flanges.

Page 4 of 5

Date of Affected Change Section Summary B 3.6.3 In the Background section changes were made to describe the Purge Supply and Exhaust System configuration (one outside valve and one inside blind flange). Also identified that blind flange uses double 0 ring seal. (Amendments 2311236)

The Applicable Safety Analyses section was changed to reflect the removal of control switch positioning and status control.

The LC0 section was changed to reflect the removal of control switch positioning and status control.

The Actions section was changed to remove the restrictions associated with opening a single valve because the penetration remains closed by the blind flange.

The Surveilance Requirements section was changed, identifying SR 3.6.3.1 as "deleted."

The References section was revised to add the NRC Safety Evaluation for Amendments 2311236.

B 3.9.3 The Background section was changed to identify correct LC0 number, 3.6.1, in place of 3.6.3.

The References section was revised to add the NRC Safety Evaluation for Amendments 2311236.

Paragraph for SR 3.9.3.2 was changed to remove reference to SR 3.6.3.5 and valve timing; non-CIVs have no timing requirement.

Page 5 of 5