July 10, 2008 Vice President, Operations Entergy Nuclear Operations, Inc.
Indian Point Energy Center 450 Broadway, GSB P.O. Box 249 Buchanan, NY 10511-0249
SUBJECT:
AUDIT REPORT FOR THE CORRECTIVE ACTIONS ASSOCIATED WITH GENERIC LETTER 2004-02 (TAC NOS. MC4689 AND MC4690)
Dear Sir or Madam:
During the week of December 3, 2007, the Nuclear Regulatory Commission (NRC) staff conducted a detailed audit of the new sump designs at Indian Point Nuclear Generating Unit Nos. 2 and 3, operated by Entergy Nuclear Operations, Inc. (Entergy). The audit focused on Entergys corrective actions related to NRC Generic Letter (GL) 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents.
Pursuant to Section 2.390 of Title 10 of the Code of Federal Regulations (10 CFR), our initial determination is that the enclosed audit report does not contain proprietary information.
However, we will delay placing the audit report in the public document room for a period of 2 weeks from the date of this letter to provide you with the opportunity to comment on any proprietary aspects. If you believe that any information in the enclosure is proprietary, please identify such information line-by-line and define the basis pursuant to the criteria of 10 CFR 2.390. After 2 weeks, the audit report will be made publicly available after making any necessary changes to remove proprietary information.
To facilitate the NRC staff's review of your comments, please provide a marked-up copy of the audit report showing proposed changes and provide a summary table of the proposed changes.
If you have any questions, please contact me at 301-415-2901.
Sincerely,
/ra/
John P. Boska, Senior Project Manager Plant Licensing Branch I-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-247 and 50-286
Enclosure:
Audit Report cc w/o encl: See next page
July 10, 2008 Vice President, Operations Entergy Nuclear Operations, Inc.
Indian Point Energy Center 450 Broadway, GSB P.O. Box 249 Buchanan, NY 10511-0249
SUBJECT:
AUDIT REPORT FOR THE CORRECTIVE ACTIONS ASSOCIATED WITH GENERIC LETTER 2004-02 (TAC NOS. MC4689 AND MC4690)
Dear Sir or Madam:
During the week of December 3, 2007, the Nuclear Regulatory Commission (NRC) staff conducted a detailed audit of the new sump designs at Indian Point Nuclear Generating Unit Nos. 2 and 3, operated by Entergy Nuclear Operations, Inc. (Entergy). The audit focused on Entergys corrective actions related to NRC Generic Letter (GL) 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents.
Pursuant to Section 2.390 of Title 10 of the Code of Federal Regulations (10 CFR), our initial determination is that the enclosed audit report does not contain proprietary information.
However, we will delay placing the audit report in the public document room for a period of 2 weeks from the date of this letter to provide you with the opportunity to comment on any proprietary aspects. If you believe that any information in the enclosure is proprietary, please identify such information line-by-line and define the basis pursuant to the criteria of 10 CFR 2.390. After 2 weeks, the audit report will be made publicly available after making any necessary changes to remove proprietary information.
To facilitate the NRC staff's review of your comments, please provide a marked-up copy of the audit report showing proposed changes and provide a summary table of the proposed changes.
If you have any questions, please contact me at 301-415-2901.
Sincerely,
/ra/
John P. Boska, Senior Project Manager Plant Licensing Branch I-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-247 and 50-286
Enclosure:
Audit Report cc w/o encl: See next page DISTRIBUTION:
See next page ADAMS Accession Number: ML081820036 OFFICE LPL1-1/PM LPL1-1/LA LPL1-1/BC NAME JBoska SLittle MKowal DATE 7/10/08 7/10/08 7/10/08 OFFICIAL RECORD COPY
DATED:
SUBJECT:
AUDIT REPORT FOR THE CORRECTIVE ACTIONS ASSOCIATED WITH GENERIC LETTER 2004-02 (TAC NOS. MC4689 AND MC4690)
DISTRIBUTION:
LPL1-1 R/F RidNrrDorl RidsNrrDorlLpl1-1 RidsNrrDorlDpr RidsNrrDirsItsb RidsNrrPMJBoska RidsNrrPMDPickett RidsNrrLASLittle (paper copy)
RidsRgn1MailCenter
Indian Point Nuclear Generating Unit Nos. 2 and 3 cc:
Senior Vice President Entergy Nuclear Operations, Inc.
P.O. Box 31995 Jackson, MS 39286-1995 Vice President Oversight Entergy Nuclear Operations, Inc.
P.O. Box 31995 Jackson, MS 39286-1995 Senior Manager, Nuclear Safety & Licensing Entergy Nuclear Operations, Inc.
P.O. Box 31995 Jackson, MS 39286-1995 Senior Vice President and COO Entergy Nuclear Operations, Inc.
440 Hamilton Avenue White Plains, NY 10601 Assistant General Counsel Entergy Nuclear Operations, Inc.
440 Hamilton Avenue White Plains, NY 10601 Manager, Licensing Entergy Nuclear Operations, Inc.
Indian Point Energy Center 450 Broadway, GSB P.O. Box 249 Buchanan, NY 10511-0249 Mr. Paul Tonko President and CEO New York State Energy, Research, and Development Authority 17 Columbia Circle Albany, NY 12203-6399 Mr. John P. Spath New York State Energy, Research, and Development Authority 17 Columbia Circle Albany, NY 12203-6399 Mr. Paul Eddy New York State Department of Public Service 3 Empire State Plaza Albany, NY 12223-1350 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Senior Resident Inspector=s Office Indian Point 2 and 3 U. S. Nuclear Regulatory Commission P.O. Box 59 Buchanan, NY 10511 Mr. Charles Donaldson, Esquire Assistant Attorney General New York Department of Law 120 Broadway New York, NY 10271 Mr. Raymond L. Albanese Four County Coordinator 200 Bradhurst Avenue Unit 4 Westchester County Hawthorne, NY 10532 Mayor, Village of Buchanan 236 Tate Avenue Buchanan, NY 10511 Mr. Jim Riccio Greenpeace 702 H Street, NW Suite 300 Washington, DC 20001 Mr. Phillip Musegaas Riverkeeper, Inc.
828 South Broadway Tarrytown, NY 10591 Mr. Mark Jacobs IPSEC 46 Highland Drive Garrison, NY 10524 Mr. Sherwood Martinelli FUSE USA via email