ML081500263
| ML081500263 | |
| Person / Time | |
|---|---|
| Site: | South Texas |
| Issue date: | 04/30/2008 |
| From: | South Texas |
| To: | Office of Nuclear Reactor Regulation |
| References | |
| NOC-AE-08002283, STI: 32284244 | |
| Download: ML081500263 (7) | |
Text
STPEGS UFSAR TABLE OF CONTENTS CHAPTER 11 RADIOACTIVE WASTE MANAGEMENT Section Title Page TC 11-1 Revision 13 11.1 SOURCE TERMS 11.1-1 11.1.1 Design Basis Radioactivity in Systems and Components 11.1-1 11.1.2 Radioactivity Concentrations in the Fluid Systems, Realistic Basis 11.1-4 11.1.3 Tritium Production and Release to the Reactor Coolant 11.1-4 11.1.4 Activity in Radwaste Systems 11.1-5 11.1.5 Leakage Sources 11.1-5 11.1.6 The Impact of Extended Burnup Fuel on Source Terms 11.1-5 11.1.7 The Impact of Operating at a Reduced Feedwater Temperature on Source Terms 11.1-5 11.1.8 The Impact of Replacement Steam Generators on Source Terms 11.1-6 11.2 LIQUID WASTE MANAGEMENT SYSTEMS 11.2-1 11.2.1 Design Bases 11.2-1 11.2.2 Systems Descriptions 11.2-1 11.2.3 Radioactive Releases 11.2-9 11.2.4 Dilution Factors 11.2-11 11.2.5 Estimated Doses 11.2-11 11.3 GASEOUS WASTE MANAGEMENT SYSTEM 11.3-1 11.3.1 Design Bases 11.3-1 11.3.2
System Description
11.3-3 11.3.3 Radioactive Releases 11.3-10 11.4 SOLID WASTE MANAGEMENT SYSTEM 11.4-1 11.4.1 Design Bases 11.4-1 11.4.2
System Description
11.4-3 11.5 PROCESS AND EFFLUENT RADIOLOGICAL MONITORING AND SAMPLING SYSTEMS 11.5-1 11.5.1 Design Bases 11.5-1 11.5.2
System Description
11.5-4 11.5.3 Effluent Monitoring and Sampling 11.5-15
STPEGS UFSAR TABLE OF CONTENTS (Continued)
CHAPTER 11 Section Title Page TC 11-2 Revision 13 11.5.4 Process Monitoring and Sampling 11.5-16 APPENDIX OFFSITE RADIOLOGICAL IMPACT DUE TO 11.A EFFLUENTS RESULTING FROM OPERATION OF THE SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION 11.A-1 11.A.1 INTRODUCTION 11.A-1 11.A.2 Summary and Conclusions 11.A-1 11.A.2.1 Maximum Individual Dose 11.A-1 11.A.2.2 Population Dose 11.A-1 11.A.2.3 Conclusions 11.A-2 11.A.3 Radiological Impact on Man 11.A-2 11.A.3.1 Dose Pathways to Man 11.A-2 11.A.3.2 Radioactivity in the Environment 11.A-2 11.A.3.3 Radiation Dose from Gaseous Effluents 11.A-3 11.A.3.4 Radiation Dose from Liquid Effluents 11.A-4 11.A.4 Dose Totals and Comparison with Federal Regulations and Natural Background 11.A-6 11.A.4.1 Individual Doses 11.A-6 11.A.4.2 Population Doses 11.A-6 11.A.5 Comparison of Site Boundary Concentrations (Design Basis Releases) to 10CFR20 Appendix B 11.A-6 11.A.5.1 Liquid Effluent Concentrations 11.A-6 11.A.5.2 Gaseous Effluent Concentrations 11.A-7
TC 11-3 Revision 13 STPEGS UFSAR LIST OF TABLES CHAPTER 11 Table Title Page 11.1-1 Parameters Used in the Calculation of Design Basis Fission and Corrosion Product Concentrations 11.1-8 11.1-2 Reactor Coolant Design Equilibrium Fission and Corrosion Product Concentrations 11.1-11 11.1-3 Volume Control Tank Vapor Activity 11.1-12 11.1-4 Parameters Used in the Calculation of Design Basis Secondary Coolant Concentrations 11.1-13 11.1-5 Secondary Coolant Design Basis Equilibrium Fission and Corrosion Product Concentrations 11.1-15 11.1-6 Parameters Used to Describe the Reactor System - Realistic Basis 11.1-18 11.1-7 Specific Activities in Principal Fluid Streams - Realistic Basis 11.1-20 11.1-8 Total Tritium Sources 11.1-23 11.2-3 Equipment Design Descriptions 11.2-12 11.2-4.1 Radionuclide Inventory of LWPS Tanks/Units (Realistic Basis) 11.2-31 11.2-4.2 Radionuclide Inventory of LWPS Tanks/Units (Design Basis) 11.2-32 11.2-5 Tanks Potentially Containing Radioactive Liquid 11.2-33 11.2-5A LWPS Tank Monitoring Provisions 11.2-34 11.2-7.1 Assumptions Used For Estimating Activity Releases 11.2-35 11.2-7.2 Expected Site Radionuclide Releases and 11.2-38 Concentrations 11.3-1.1 Expected Annual Activity Released Per Unit 11.3-12 11.3-2 Assumptions Used for Estimating Activity Releases for Tables 11.3-1.1 and 11.3-1.2 11.3-13 11.3-3 Gaseous Waste Processing System Component Design Parameters 11.3-15
STPEGS UFSAR LIST OF TABLES (Continued)
CHAPTER 11 Section Title Page TC 11-4 Revision 13 11.3-5.1 Estimate of Maximum Component Activity -
Design Basis 11.3-18 11.3-5.2 Estimate of Maximum Component Activity -
Realistic Basis 11.3-19 11.3-5.3 Maximum and Realistic GWPS Inlet Activity 11.3-20 11.3-6 Gaseous Waste Processing System Instrumentation 11.3-21 11.4-1 Solid Waste Processing System Fabrication Codes 11.4-11 11.4-4 Estimated Maximum Annual Quantities of Solid Radwaste for One Unit 11.4-12 11.4-5 Estimated Maximum Annual Activities of the Inputs to the Solid Waste Processing System 11.4-13 11.4-6 Estimated Expected Annual Activities of the Inputs to the Solid Waste Processing System 11.4-15 11.4-7 Estimated Maximum Annual Activities in Shipped Radwaste 11.4-17 11.4-8 Estimated Expected Annual Activities in Shipped Radwaste 11.4-19 11.5-1 Process and Effluent Radiation Monitoring System 11.5-17 11.5-2 Radiation Monitoring System Failure Modes and Effects Analysis 11.5-22 11.A-1 Calculated Concentrations of Radioactive Materials in Environmental Media from Liquid Effluents of the South Texas Project Electric Generating Station 11.A-9 11.A-2 Maximum Site Boundary Concentration Compared to 10CFR20 Limits 11.A-10 11.A-3 Summary of Calculated Gaseous Pathway Doses South Texas Project Electric Generating Station 11.A-11 11.A-4 Summary of Calculated Liquids Pathway Doses South Texas Project Electric Generating Station 11.A-12
STPEGS UFSAR LIST OF TABLES (Continued)
CHAPTER 11 Section Title Page TC 11-5 Revision 13 11.A-5 Predicted Doses to the Population Within 50 Miles of the South Texas Project Electric Generating Station 11.A-13 11.A-6 Appendix I Conformance Summary Table South Texas Project Electric Generating Station 11.A-14 11.A-7 Comparison of Site Boundary to 10CFR20 Appendix B Maximum Permissible Limits (Expected Concentrations) 11.A-16
TC 11-6 Revision 13 STPEGS UFSAR LIST OF FIGURES CHAPTER 11 Figure Reference Number Title Number 11.2-1 P&ID Liquid Waste Processing 5R30-9-F-05022#1 System 5R30-9-F-05022#2 11.2-2 P&ID Liquid Waste Processing System 7R30-9-F-05023#1 7R30-9-F-05023#2 11.2-3 P&ID Liquid Waste Processing 7R30-9-F-05024#1 System 7R30-9-F-05024#2 11.2-4 P&ID Liquid Waste Processing System 7R30-9-F-90000#1 7R30-9-F-90000#2 11.2-5 P&ID Liquid Waste Processing 7R30-9-F-90001#1 System 7R30-9-F-90001#2 11.2-6 P&ID Liquid Waste Processing System) 7R30-9-F-05026#1 Waste Evaporator Package 7R30-9-F-05026#2 11.2-7 P&ID Liquid Waste Processing System 7R30-9-F-90020#1 Waste Evaporator Package 7R30-9-F-90020#2 11.2-8 P&ID Liquid Waste Processing 7R30-9-F-90017#1 System - Pump Seal Water System 7R30-9-F-90017#2 11.2-9 P&ID Liquid Waste Processing 7R30-9-F-90018#1 System 7R30-9-F-90018#2 11.2-10 P&ID Liquid Waste Processing System 7R30-9-F-90021#1 7R30-9-F-90021#2 11.2-11 P&ID Liquid Waste Processing 7R30-9-F-90022#1 System 7R30-9-F-90022#2 11.2-12 Flow Diagram Liquid Waste Processing 7R30-9-F-90023 System (Flow) 11.3-1 Gaseous and Airborne Waste Processing Systems
STPEGS UFSAR LIST OF FIGURES (Continued)
CHAPTER 11 Figure Reference Number Title Number TC 11-7 Revision 13 11.3-2 P&ID Gaseous Waste Processing 7R31-9-F-05043#1 7R31-9-F-05043#2 7R31-9-F-05055#1 7R31-9-F-05055#2 11.3-3 P&ID RCS Vacuum Degassing System 5R34-9-F-05046#1 5R34-9-F-05046#2 11.4-1 P&ID Solid Waste Processing System 6R32-9-F-05048#1 6R32-9-F-05048#2 11.4-2 P&ID Solid Waste Processing System 6R32-9-F-05059#1 6R32-9-F-05059#2 11.4-3 Process Flow Diagram, Solid Waste Processing System 11.5-1 Block Diagram Radiation Monitoring System 11.A-1 Exposure Pathways to Man