1 NRC ASSESSMENT:
INDIAN POINT CONTAMINATED GROUNDWATER
2 Agenda
- 6:30 Introductions
- Marc Dapas, Deputy Regional Adminstrator
- 6:40 Meeting Ground Rules
- Rich Barkley, Technical Communications
- 6:45 Entergy Presentation
- Don Mayer, Director of Special Projects
- 7:10 NRC Presentation
- John White, Branch Chief, Plant Support 2
- 7:50 Break
- 8:00 Questions and Answers
3 NRC Inspection and Assessment Team Principal Inspection Contributors:
- NRC Region I
- James Noggle, Senior Health Physicist
- James Kottan, Senior Health Physicist
- John White, Chief, Plant Support Branch 2
- NRC Office of Research
- Thomas Nicholson, Senior Technical Advisor-Radionuclide Transport
- US Geological Survey
- John Williams, Senior Hydrologist
4 Coordinating Government Agencies Federal:
- US Geological Survey (USGS)
New York State:
- Department of Environmental Conservation (DEC)
- Department of Public Health (DPH)
5 Purpose
- Evaluate Entergys performance and provide status of inspection findings associated with the following:
- Cause of the groundwater contamination
- Extent and migration of the groundwater releases
- Radiological significance of these releases
- Ensure that public health and safety and protection of the environment were maintained
6 Purpose
- Ensure Entergys groundwater transport model is correct and tested
- Research prior opportunities for leak discovery and evaluate Entergys response
- Determine Entergys conformance with regulatory requirements
7 Scope
- Assess Entergys investigation of the Unit 2 spent fuel pool leak since August 2005
- Examine Entergys investigation of previous Unit 1 and Unit 2 spent fuel pool leaks identified in 1992
8 Scope
- Independent Assessment Effort:
- Collection and analysis of groundwater samples
- Verification of licensees hydrological conclusions
- Verification of dose assessment to the public
- Verification of water inventory losses from Unit 1 and Unit 2 spent fuel pools
- Verification of no detectable environmental impact through the analysis of aquatic food samples from the Hudson River.
9 Scope
- Comprehensive assessment of groundwater transport pathways and contaminant plume behavior
- Historical conditions
10 NRC Assessment
- Independent analysis confirms offsite migration is limited to the Hudson River
- The groundwater transport model was based on well-developed data, measurements, and field observations
11 NRC Assessment During site visits and teleconferences, questions posed:
3/4 to evaluate the Conceptual Site Model assumptions, and 3/4 to pro-actively engage Licensees contractor in developing corroborating field data 3/4 to understand ground-water plume sources, extent, and behavior
12 NRC Staff from Region I and Office of Nuclear Regulatory Research provided technical oversight of IPEC ground-water contamination studies U.S. Geological Survey scientist provided technical support to the technical oversight Initial ground-water contamination identified in leak from Unit 2 Spent Fuel Pool Site visits focused on technical questions concerning the contaminant sources, pathways, potential receptors, and monitoring to detect future leaks Field data from rock cores, monitoring wells, geophysical surveys, hydraulic tests and tracer tests independently reviewed NRC Inspection Focus and Activities
13 NRC Assessment Questions
- What are the source(s) of the ground-water contamination?
- Where do they intersect the accessible environment?
- Are there fast and preferential pathways?
- Do the contaminant plumes move under the Hudson River?
- Are local drinking water sources affected?
- Are the plumes captured by the Discharge Canal?
- What are the hydraulic controls on the plume(s) behavior as reflected in the Conceptual Site Model?
- What remediation is appropriate?
- How can future leaks be detected?
- What surveillance is needed to confirm dose assessments remain below regulatory limits?
14 NRC Assessment Fundamental Understanding for the Conceptual Site Model Nature of the leaks and initial pathways through backfills and fractured rock at or above the local water table.
Role of fractures and possibility of solutioning & connectivity Interaction of ground-water flow with the Hudson River Location and relationships to local drinking water sources Ground-water flow gradients, vertical and horizontal flow directions related to the sources, Discharge Canal, and River Movement of H-3, Sr-90, Cs-137 and Ni-63 to the River Benefits of a long-term ground-water monitoring program
15 NRC Assessment Conclusions Unit 1 and 2 are the source(s) of the ground-water contamination Plumes move west, intersect the Hudson River but not under to Rockland County Backfills and connected fractures are the preferential pathways No local drinking water sources are affected Discharge Canal captures some but not all of the plume Ground-water gradient and flow direction controlled by local hydrology Monitored natural attenuation is the appropriate remediation approach Future leaks can be detected by monitoring wells near Units 1 and 2 Long-term monitoring is needed to confirm dose assessments remain below regulatory limits during plant operations
16 NRC Assessment
- Entergy implemented timely actions to investigate source, and determine dose impact
- Entergy conformed to regulatory survey requirements with 1 minor violation of quality control of sample analyses
- Groundwater contamination resulted only from leakage attributed to Unit 1 and Unit 2
- Entergys site characterization was based on state-of-the-practice monitoring wells, tests, and analysis methods
17 NRC Assessment
- Exposure pathway to man is aquatic food from Hudson River (fish, invertebrates)
- Calculated exposure to maximum exposed individual is 0.002 mrem/yr total body and 0.01 mrem/yr maximum organ
- Calculated exposures are less than 0.1%
of NRC regulatory limit
18 Radiation Dose Perspective Background (est.) 360 mrem/year (NCRP 94)
Public Dose Limits 100 mrem/year (10CFR20.1301) 25 mrem/year (40CFR190)
Liquid Effluent Limit 3 mrem/year, total body 10 mrem/year, organ (10CFR50, App. I)
Estimated Dose Rate 0.002 mrem/year, total body 0.01 mrem/year, bone EPA drinking water limits (40 CFR 141.16)
Tritium (H-3) 20,000 pCi/L Strontium (Sr-90) 8 pCi/L (EPA maximum contaminant level based on 4 mrems per year)
19 NRC Assessment-Regulatory Requirements
- Entergy is monitoring and reporting the groundwater effluent release condition in accordance with NRC regulations
- Relative to Unit 1, there was no condition in which the licensee failed to meet a regulatory requirement or standard that was reasonably within its ability to detect or correct
20 NRC Assessment
- Entergy has initiated a long-term monitoring process to:
- Report groundwater liquid releases
- Measure the effectiveness of remediation and natural attenuation
- Detect new or changing groundwater contamination conditions
21 NRC Lessons-Learned NRC Lessons Learned Task Force Identified:
- No regulatory guidance for detecting, evaluating, and monitoring releases via unmonitored pathways
- No regulatory requirement / guidance for remediation of groundwater conditions
- No requirement to assure leaks and spills will be detected before migration off-site Actions have been initiated to address these and other identified issues.
22 Planned and Continuing NRC Inspection and Assessment
- Assessment of Long-Term Groundwater Monitoring Plan
- Inspection oversight of Unit 1 fuel removal and pool draining activities
- Baseline inspection now includes aspects of groundwater protection and assessment
- Inspection initiative to confirm licensee implementation of Industry Groundwater Protection Initiative
23 Additional Information
- NRC Homepage
- www.nrc.gov
- Indian Point 2 Current Performance Summary
- www.nrc.gov/NRR/OVERSIGHT/ASSESS/IP2/ip2_chart.html
- Indian Point 3 Current Performance Summary
- www.nrc.gov/NRR/OVERSIGHT/ASSESS/IP2/ip3_chart.html
- Indian Point "Specific Plant of Interest" Page
- www.nrc.gov/reactors/plant-specific-items/indian-point-issues.html
- Indian Point License Renewal Review Status
- www.nrc.gov/reactors/operating/licensing/renewal/applications/in dian-point.html
- USGS Open-File Report on Flow-Log Analysis