IftEntergy April 07, 2008 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Palisades Nuclear Plant Docket 50-255 License No. DPR-20 2007 Steam Generator Tube Inspection Report
Dear Sir or Madam:
Entergy Nuclear Operations, Inc.
Palisades Nuclear Plant 27780 Blue Star Memorial Highway Covert, MI 49043 Technical Specification 5.6.8 Entergy Nuclear Operations, Inc. (ENO) is providing the enclosed steam generator tube inspection report in accordance with Technical Specification 5.6.8. ENO is required to submit the report within 180 days after initial entry into mode 4 following completion of the inspection. Mode 4 was entered on October 14, 2007.
Summary of Commitments This letter contains no new commitments and no revisions to existing commitments.
Laurie A Lahti Licensing Manager Palisades Nuclear Plant Enclosure (1)
CC Administrator, Region III, USNRC Project Manager, Palisades, USNRC Resident Inspector, Palisades, USNRC
ENCLOSURE 1 2007 STEAM GENERATOR TUBE INSPECTION REPORT 72 pages follow
PALISADES NUCLEAR PLANT STEAM GENERATOR TUBE INSPECTION REPORT far the 2007 REFUELING OUTAGE
TABLE OF CONTENTS Inspection Summary 3
New Damage Mechanism for 2007 4
Secondary Inspection of the Steam Generators 6
Table 1 Scope and Extent of Tubes Inspected 7
Table 2 Active Damage Mechanisms 7
Table 3 Nondestructive Examination Techniques 8
Table 4A Location and Measured Sizes of Service Induced Indications 11 Table 4B Steam Generator E-50A Indications 12 Table 4C Steam Generator E-50B Indications 46 Table 5 Tube Plugging Summary by Damage Mechanism 70 Table 6 Identification of Tubes Plugged 71 Table 7A Steam Generator Support Structure Nomenclature 72 Table 7B Acronyms and Abbreviations 72 2
Inspection Summary This report provides the Technical Specifications (TS) section 5.6.8, Steam Generator [SG] Tube Inspection Report, required information.
a.
The scope of inspections performed on each SG (Table 1),
b.
Active degradation mechanisms found (Table 2),
c.
Nondestructive examination techniques utilized for each degradation mechanism (Table 3),
d.
Location, orientation (if linear), and measured sizes (if available) of service induced indications (Tables 4A, 4B and 4C),
e.
Number of tubes plugged during the inspection outage for each active degradation mechanism (Table 5),
f.
Total number and percentage of tubes plugged to date (Table 5),
g.
The results of condition monitoring, including the results of tube pulls and in-situ testing (Table 6), and h.
The effective tube plugging percentage for all plugging in each SG (Table 5).
The TS section 5.5.8b.1 steam generator tube integrity structural integrity performance criterion was satisfied. The TS section 5.5.8b.2 steam generator tube integrity accident induced leakage performance criterion was satisfied.
Leakage did not exceed the 0.3 gallon per minute (gpm) limit.
Primary-to-secondary leak rate measured using condenser off-gas (Xenon-1 33 or Xenon-1
- 35) was <0.001 gpm for operating cycle 19 with a slightly decreasing trend over the cycle.
No leakage was predicted for the 2006 to 2007 operating cycle due to observed SG tube degradation at the 2006 refueling outage. All plugs installed in the Palisades SGs post-operation are Westinghouse ribbed mechanical plugs, which are leak-tight for all plant conditions. The Palisades SGs also contain 308 tubes plugged pre-service in SG E-50A, and 309 tubes plugged pre-service in SG E-50B. Of the tubes plugged pre-service, one tube in SG E-50A and four tubes in SG E-50B are plugged using welded plugs, which are leak tight. The remaining tubes plugged pre-service are plugged using Combustion Engineering (C-E) roll plugs, which are also designed to be leak tight for all plant conditions.
Fourteen tubes were plugged in SG E-50A and ten tubes in SG E-50B during the 2007 refueling outage.
Refer to Tables 5 and 6 for details. No tubes were pulled in either SG. No in-situ pressure testing was done on any tubes.
3
Table A Refueling Outage (RFO) Information since Steam Generator Replacement RFO No.
Year Cycle EFPD Cycle EFPM Replacement SG Cumulative EFPM Inspection Period EFPM Sequential Inspection Period Notes 8
1990/
1991 NA NA 0.0 NA NA SG Replacement 9
1992 298.5 9.8 9.8 0.0 NA 15 ISI both SG 10 1993 356.8 11.7 21.5 11.7 First ISI both SG 11 1995 430.5 14.1 35.6 25.9 First ISI both SG 12 1996 407.4 13.4 49.0 39.3 First ISI both SG 13 1998 419.6 13.8 62.8 53.0 First ISI both SG 14 1999 449.3 14.8 77.6 7.8 Second ISI both SG 15 2001 401.3 13.2 90.8 21.0 Second ISI both SG 16 2003 444.3 14.6 105.4 35.6 Second ISI both SG 17 2004 493.1 16.2 121.6 51.8 Second ISI both SG 18 2006 487.9 16.0 137.6 7.8 Third ISI both SG 19 2007 459.3 15.1 152.7 22.9 Third ISI both SG EFPD = effective full power days EFPM = effective full power months New Damage Mechanism for 2007 A new SG tube damage mechanism of tube to tube wear was identified during the 2007 inspection in SG E50-A.
Condition Description SG E-50A tube R136 C77 was examined with a +Pt rotating pancake coil (RPC) at the cold leg diagonal bar (DBC) location to confirm the morphology of a historical wear scar at the upper edge of DBC. The +Pt coil data analysis confirmed the bobbin signal as tube wear due to structure interaction, however, an additional volumetric signal was reported. This signal was located immediately between the two diagonal bars on either side of the tube. The 4
signal was approximately three inches long, with a maximum estimated depth of 16% through wall (TW) using the +Pt coil and sizing procedure as defined by EPRI Technique Specification Sheet (ETSS) 96910.1. The signal extended below the DBC by approximately one inch.
It was suspected that the source of the signal was tube wear due to interaction with an adjacent tube in the same column.
Only tubes in the same column could interact as the diagonal bars prevent interaction in the lateral direction.
R134 C77 (the inboard tube) was inspected with +Pt RPC; no degradation was observed.
R138 C77 (the outboard tube) was found to have been plugged in 1998 due to a 39% TW indication at vertical strap (VS7) and a 16%TW indication at the DBC. As +Pt RPC testing of tube R138 C77 could not be performed, potential tube to tube contact with wear could not be ruled out as a source of the indication. Tube R138 C77 had been preventively stabilized using a 384-inch stabilizer and plugged.
Analysis of the bobbin data of R136 C77 could not identify the additional indication.
This could be attributed to the shallow taper of the indication which would have a minimal influence upon the differential channels. The absolute channels were also examined but no flaw-like signal was present. The axial location (2/3 of the flaw length inside of the diagonal bar) could also add an additional interference with regard to detection of such indications. As a precaution, the bobbin data, in particular the absolute channels, was reviewed for all tubes in rows 130 through 138. No abnormal signals or characteristics were noted. The RPC data (from all previous inspections) for tubes with bobbin reported wear scars at the DBC and hot leg diagonal bar (DBH) in rows 134 through 138 were reviewed for both SGs. No similar indications were reported.
In addition, the bobbin based signal elevation reports for all indications at the DBC or the DBH were reviewed to identify any indication which might extend beyond the edge of a diagonal bar. Three locations were reported to have bobbin signals slightly outside of the normal elevation range of +/- 2 inches about the structure. The RPC data for these locations was also reviewed; the only wear signals reported were located on the diagonal bars. As the row count decreases the distance between the diagonal bar region and uppermost eggcrate also decreases. The eggcrate controls the tube positioning, thus the potential to experience a similar situation is decreased with decreasing row count.
Corrective Action:
The R136 C77 tube was plugged following the insertion of a 384-inch stabilizer (WO 284927). An extent of condition evaluation identified no additional tubes with this condition.
This new degradation mechanism inspection using +Pt RPC and technique ETSS 96910.1 was identified in the 2007 Steam Generator Degradation Assessment as an active damage mechanism.
Additionally, this active degradation mechanism was discussed in the 2007 Steam Generator Condition Monitoring and Operational Assessments. This active damage mechanism will be included in the 2009 Steam Generator Degradation 5
Assessment. The additional tubes to be +Pt RPC eddy current tested are included in the special interest scope.
Secondary Inspection in the SGs included Annulus and Tube Lane Foreign Object Search and Retrieval (FOSAR)
The possible loose parts in both SGs were reviewed by FOSAR. No loose parts required removal in SG E-50A.
Only small sludge rocks, that broke when retrieval was attempted, were identified.
In SG E-50B "two" loose parts were identified and removed.
Several small pieces of demister wire, -16 mils diameter X <_1l2-inch lengths, from the moisture separator reheaters, are referred to as one loose part. The other loose part was a piece of carbon steel -1/4" x 3" The remaining loose parts were sludge rocks that broke during retrieval attempts.
A visual inspection of the lower batwings (diagonal bars) was completed for both SGs. No broken batwings were identified.
There were four tubes plugged as a result of interaction with a possible loose part (PLP). Three tubes were plugged in SG E-50A and one in SG E-50B SG E-50A: R129 C108, just above cold eggcrate 08C.
This location is one tube pitch in from periphery. PLP signals are reported for both 8129 C108 and R128 C109; only R129 C108 has a single volumetric indication (SVI).
Both tubes removed from service by tube plugging. Tube R129 C108 had a 368-inch stabilizer installed prior to plugging.
SG E-50A, R136 C77 at the diagonal cold bar (DBC).
This location was RPC tested because of a bobbin wear call at 08C + 1.84 inches. As discussed above, this new damage mechanism wear scar was confirmed, and is on one of the diagonal bars. Tube R136 C77 had a 368-inch stabilizer installed prior to tube plugging.
SG E-50B : R70 C13 just outside of vertical strap 4 (VS4).
This is a peripheral location. No PLP reports for surrounding tubes; RPC of surrounding tubes has been completed. Tube R70 C13 had a 368-inch stabilizer installed prior to tube plugging The three SG tubes with single volumetric indications (SVI) were stabilized and removed from service by tube plugging in both steam generators.
There was one additional tube plugged (due to a PLP) next to a single volumetric indication, 6
Table 1 Scope and Extent of Tubes Inspected Scope Probe Type SIG E-50A S/G E-50B Full LengthcD Bobbin 100%
100%
Row 1 through 3 U-bends MRPC 100%
100%
Hot Leg Tubesheets TTS+3"/- 13.5" MRPC 100%
100%
Cold Leg Periphery TTS+2"/-2" MRPC 11.3%
11.4%
Freespan Dings > 5.0 Volts MRPC 100%
100%
Vertical Strap & Diagonal Bar Dents
> 3.5 Volts MRPC 100%
100%
Eggcrate Dents > 2.0 Volts MRPC 100%
100%
Historical Wear at Eggcrates MRPC 100%
100%
Historical Wear at Diagonal Bars and Vertical Straps MRPC 100%
00f° 100%
Supplemental© MRPC 100%
100%
Plug Visual N/A 100%
100%
O Except the bend portion of rows 1 through 3 a All DNI, DSI, NQI, PLP (Bound MRPC PLPs), PVN and new wear indications.
Table 2 Active Damage Mechanisms SG Location Damage Mechanism E-50A&B Wear at Structures Wear E-50A&B Wear due to foreign objects/loose parts Wear E-50A&B Eggcrates Axial ODSCC E-50A&B Frees an Axial ODSCC E-50A&B All Frees an Dings (all voltages )
Axial ODSCC E-50A&B Hot Leg TTS Expansion Transition &
Sludge Pile Circumferential ODSCC E-50A&B Hot Leg TTS Expansion Transition &
Sludge Pile Axial ODSCC E-50A&B Hot Leg TTS Expansion Transition &
Expanded Tube Length Axial PWSCC E-50A&B Tube to Tube Wear Wear 7
Table 3 Probe and Technique Sheet Application : Detection and Confirmation : Palisades REFOUT 19 Degradation Location Detection Probe EPRI Technique Confirmation EPRI Technique Mechanism Type Sheet -
Probe Type Sheet - Confirmation Detection Probe and Technique Sheet Application: Detection and Confirmation Active Degradation Mechanisms Tube Wear Non dented Vertical Bobbin: 0.610"
- 96004.1 Plus Point
- 96004.3 (bobbin sizing)
Straps, Diagonal Bars,
- 96911.1 (+Pt)
E crates Axial ODSCC Non dented Vertical Bobbin: 0.610"
- 96008.1 Plus Point
- 21409.1 Straps, Diagonal Bars, E
crates Axial ODSCC Dented Eggcrates, Bobbin: 0.610" or
- 96008.1 Plus Point
- 22401.1 Diagonal Bars, Vertical Plus Point:
- 24013.1 Straps <3.5 volts (V) 0.610"/0.580" Axial ODSCC Frees an Bobbin: 0.610"
- 96008.1 Plus Point
- 21409.1 Axial ODSCC Frees an Din gs < 5V Bobbin: 0.610"
- 24013.1 Plus Point
- 22401.1 Axial ODSCC Freespan dings >5V, Plus Point:
- 22401.1 N/A N/A dented tube support 0.610"/0.580" structures >3.5V Circumferential Hot leg TTS expansion Plus Point: 0.610"
- 21409.1 N/A N/A expansion transition Axial PWSCC Hot Leg TTS Plus Point: 0.610"
- 20511.1 N/A N/A expansion transition and expanded tubesheet Axial PWSCC Row 1-3 U-bends Mid-range Plus
- 96511.2 N/A N/A Point: 0.610/0.580"
Table 3 Probe and Techni que Sheet Application : Detection and Confirmation: Palisades REFOUT 19 Degradation Location Detection Probe EPRI Technique Confirmation EPRI Technique Mechanism Type Sheet -
Probe Type Sheet - Confirmation Detection Row 1-3 U-bends high High Freq. Plus
- 99997.1 N/A N/A noise Point: 0.610/0.580" Tube Wear Dented Vertical Straps, Bobbin: 0.610" None Plus Point
- 21998.1 Diagonal Bars &
Reference 1
Eggcrates<5V Dented Vertical Straps, Plus Point:
None N/A
- 21998.1 Diagonal Bars and 0.610"10.580" Reference 2 Eggcrates, >5V Tube Wear All locations Bobbin: 0.610"
- 96001.1 Plus Point
- 96001.1 (loose parts)
TTS periphery and Plus Point: 0.610"
- 21998.1 N/A N/A tube lane Resolution for Classification of Indications Potential MBMs All Bobbin: 0.610"
- 96008.1 Plus Point
- 21409.1 To Be Defined Bobbin Signals at Plus Point:
- 21409.1 N/A N/A Suspected Wear Sites 0.610"/0.580" not yet characterized Potential Degradation Mechanisms Circumferential Row 1-3 U-bends in Mid-range Plus
0.610/0.580" Row 1-3 U-bends in High Freq. Plus
- 99997.1 N/A N/A both SG - high noise Point:
0.610/0.580" Circumferential Expanded tube in Plus Point: 0.610"
- 20510.1 N/A N/A PWSCC tubesheet and expansion transition
Table 3 Probe and Technique Sheet Application: Detection and Confirmation : Palisades REFOUT 19 Degradation Location Detection Probe EPRI Technique Confirmation EPRI Technique Mechanism Type Sheet -
Probe Type Sheet - Confirmation Detection Axial PWSCC Dented support Plus Point
- 96703.1 N/A N/A structures 0.610"/0.580" Circumferential Dented Vertical Strap Plus Point 0.580"
- 21410.1 N/A N/A ODSCC Locations Pittin g Sludg e Pile Bobbin: 0.610"
- 96005.2 Plus Point
- 21409.1 Axial ODSCC Wear Sites Bobbin: 0.610"
- 94001.1 Plus Point
- 21409.1
- 96008.1 Reference 1
- MRS-TRC-1708, "Bobbin Detection of Wear at Dented Vertical Straps and Diagonal Bars," Westinghouse Electric Co.
LLC, December 2005 Reference 2 - LTR-SGDA-06-21 Revision 1, "NDE Sizing Uncertainties Applied for Palisades REFOUT 19 SG Inspection,"
Westinghouse Electric Co. LLC, June 5, 2007 10
Table 4A Location and Measured Sizes of Service Induced Indications Length Length Circum-Axial frential
+Pt
+Pt (Ax)
(Circ)
Depth SG Row Column IND Location Elevation Volts inch (degrees)
Mechanism Volta a Comments Tubesheet Region A
59 28 SAl TSH 0.35
- 709--T-0.16 Ax ODSCC 39 A
71 98 SAI TSH 0.52 0.24 0.19 Ax ODSCC 51 Possible bulge A
33 102 SAI TSH
-4.41 0.49 0.13 Ax PWSCC 39 signal resent B
26 51 SAI TSH 0.53 0.28 0.43 Ax ODSCC 54 B
115 2
SCI TSH 0.06 0.22 47 Circ ODSCC 50 B
20 53 SAI TSH 0.12 0.14 0.13 Ax ODSCC 44 B
3 54 SAI TSH
-9.93 0.58 0.13 Ax PWSCC 42 B
57 108 SCI TSH 0.07 0.13 40 Circ ODSCC 43 B
20 1 11 SCI TSH
-0.43 0.15 61 Circ ODSCC 45 B
48 113 SAl TSH 0.72 0.22 0.22 Ax ODSCC 50 Note: Elevation report is from top of tubesheet to largest amplitude report Freespan Loose Part A
129 108 SVI 08C 1.79 0.22 0.37 69 Wear
<20%TW Stabilized Possible tube to A
136 77 SVI DBC
-0.5 to -3.77 0.46 3.27 37 Wear
<20%TW tube wear Traced to B
55 82 VOL TSH 4.7 0.19 0.34 74 La
<20%TW baseline Loose Part B
70 13 SVI VS4
-1.66 0.14 0.25 64 Wear
<20%TW Stabilized Note: Elevation report is from center of structure to largest flaw amp litude report 11
Length Length Circum-Axial frential
+Pt
+Pt (Ax)
(Circ)
Depth SG Row Column IND Location Elevation Volts (inch )
(degrees)
Mechanism Voltage Comments Eggcrate True eggcrate A
15 126 SAI 01H 0.8 0.17 0.33 Ax ODSCC 46 ODSCC Possible ding A
39 22 SAI 01 H 0.72 0.33 0.3 Ax ODSCC 56 influence Possible ding A
53 126 5AI 02H 0.86 0.31 0.26 Ax ODSCC 55 influence True eggcrate A
121 82 SAI 02H 0.67 0.23 0.2 Ax ODSCC 51 ODSCC Possible ding A
92 99 SAI 07H
-0.98 0.13 0.26 Ax ODSCC 43 influence True eggcrate A
107 96 SAI 02H 0.86 0.24 0.26 Ax ODSCC 51 ODSCC Possible ding B
67 100 SRI 01H 0.2 0.31 0.52 Ax ODSCC 55 influence Ding Crack: >5V B
23 102 SAI VS4 0.62 0.34 0.16 Ax ODSCC 57 din Note: Elevation report is from center of structure to largest flaw amplitude report 12
Table 4B Steam Generator E-50A Indications (all indications due to tube wear for tubes that remain in service)
No.
SG Row Column Depth in Percent Location Elevation Status 1
A 1
150 15 01C
-0.4
<TS 2
A 40 5
13 01C
-0.96
<TS 3
A 48 7
23 01C 0.79
<TS 4
A 53 10 15 01C
-0.94
<TS 5
A 55 8
16 01C
-0.19
<TS 6
A 62 11 14 01C
-0.95
<TS 7
A 63 12 14 01C
-0.93
<TS 8
A 67 154 12 01C 0
<TS 9
A 74 15 12 01C
-0.85
<TS 10 A
89 72 14 01C 0.8
<TS 11 A
97 80 13 01C 0.9
<TS 12 A
105 32 16 01C 0.16
<TS 13 A
108 35 26 01C 0.03
<TS 14 A
108 35 19 01C 0.71
<TS 15 A
117 42 33 01C
-0.97
<TS 16 A
118 43 33 01C
-0.97
<TS 17 A
121 44 18 01C
-0.98
<TS 18 A
122 45 16 01C 0.92
<TS 19 A
29 162 14 01H
-0.82
<TS 20 A
47 8
16 01H
-0.82
<TS 21 A
48 159 6
01H
-0.92
<TS 22 A
48 159 15 01H
-0.21
<TS 23 A
48 159 10 01H 0.77
<TS 24 A
53 10 15 01H
-0.89
<TS 25 A
81 18 16 01H 0.97
<TS 26 A
106 135 14 01H 0.26
<TS 27 A
109 34 14 01H 0.94
<TS 28 A
110 35 18 01H 1.01
<TS 29 A
120 123 17 01H
-0.03
<TS 30 A
124 49 15 01H 0.9
<TS 31 A
126 51 13 011-1 0.13
<TS 32 A
132 61 13 01H
-0.03
<TS 33 A
1 150 18 02C 0.83
<TS 34 A
9 2
20 02C 0.08
<TS 35 A
12 3
20 02C 0.88
<TS 36 A
14 3
27 02C 0.9
<TS 37 A
20 3
16 02C
-0.92
<TS 38 A
24 161 12 02C
-0.75
<TS 39 A
24 161 17 02C 0.82
<TS 40 A
24 163 21 02C 1.05
<TS 41 A
26 3
19 02C
-0.95
<TS 42 A
32 7
23 02C
-0.88
<TS 43 A
38 115 7
02C
-1.2
<TS 13
No.
SG Row Column Depth in Percent Location Elevation Status 44 A
38 115 12 02C 0.82
<TS 45 A
40 35 13 02C 0.22
<TS 46 A
40 125 14 02C 0.81
<TS 47 A
41 6
14 02C
-0.08
<TS 48 A
41 126 15 02C
-0.81
<TS 49 A
42 7
11 02C 0.11
<TS 50 A
42 7
21 02C 0.88
<TS 51 A
42 117 18 02C 0.86
<TS 52 A
46 111 9
02C
-1.15
<15 53 A
46 111 12 02C 0.8
<TS 54 A
48 111 14 02C 0.82
<TS 55 A
48 125 17 02C 0.25
<TS 56 A
48 125 18 02C 0.95
<TS 57 A
49 132 17 02C 0.8
<TS 58 A
51 92 4
02C
-0.38
<TS 59 A
51 92 15 02C 0.95
<TS 60 A
51 118 17 02C
-0.8
<TS 61 A
51 122 15 02C
-0.14
<TS 62 A
51 126 17 02C 0.22
<TS 63 A
51 126 12 02C 0.83
<TS 64 A
52 97 15 02C
-0.87
<TS 65 A
52 111 19 02C 0.79
<TS 66 A
52 117 23 02C 0.83
<TS 67 A
53 118 15 02C 0.91
<TS 68 A
53 122 21 02C
-0.16
<TS 69 A
54 29 19 02C 0.9
<TS 70 A
54 93 15 02C 0.92
<TS 71 A
54 105 16 02C 0.96
<TS 72 A
54 119 15 02C 0.77
<TS 73 A
55 84 10 02C 0
<TS 74 A
55 88 13 02C
-0.92
<TS 75 A
55 96 12 02C
-0.14
<TS 76 A
55 114 15 02C 0.85
<TS 77 A
55 120 13 02C
-0.22
<TS 78 A
55 122 15 02C
-0.16
<TS 79 A
56 115 16 02C 0.71
<TS 80 A
57 110 11 02C
-0.22
<TS 81 A
57 110 17 02C 0.85
<TS 82 A
57 138 14 02C 0.77
<TS 83 A
59 90 12 02C
-0.88
<TS 84 A
59 106 13 02C 0.83
<TS 85 A
59 118 8
02C
-0.14
<TS 86 A
59 118 11 02C 0.91
<TS 87 A
60 119 21 02C 0.79
<TS 88 A
60 121 20 02C 0.77
<TS 89 A
62 121 14 02C 0.77
<TS 90 A
63 86 11 02C
-0.98
<TS 14
No.
SG Row Column Depth in Percent Location Elevation Status 91 A
65 90 15 02C 0.97
<TS 92 A
65 106 14 02C 0.8
<TS 93 A
66 107 15 02C
-1.09
<TS 94 A
66 109 21 02C 0.91
<TS 95 A
66 113 14 02C 0.86
<15 96 A
67 114 25 02C 0.83
<TS 97 A
67 154 15 02C 0.89
<TS 98 A
71 108 15 02C
-0.14
<TS 99 A
72 53 14 02C 0.79
<TS 100 A
72 89 10 02C 0.82
<TS 101 A
75 68 19 02C 1.16
<TS 102 A
75 150 17 02C 0.97
<TS 103 A
76 91 17 02C 0.75
<TS 104 A
77 92 16 02C
-1.02
<TS 105 A
77 150 17 02C 0.91
<TS 106 A
78 113 19 02C 0.86
<TS 107 A
78 119 15 02C 0.94
<TS 108 A
78 147 15 02C
-0.14
<TS 109 A
79 148 12 02C 0.83
<TS 110 A
79 150 16 02C
-0.03
<TS 111 A
79 150 14 02C 0.74
<TS 112 A
83 112 17 02C
-0.27
<TS 113 A
85 92 20 02C 0.75
<TS 114 A
88 61 23 02C 0.86
<TS 115 A
88 145 31 02C 0.11
<TS 116 A
90 101 16 02C 0.08
<TS 117 A
90 143 22 02C
-1.03
<TS 118 A
90 143 19 02C 0.06
<TS 119 A
92 141 15 02C
-0.16
<TS 120 A
94 85 18 02C 0.83
<TS 121 A
95 110 14 02C
-0.87
<TS 122 A
95 142 16 02C 0
<TS 123 A
95 142 12 02C 0.61
<TS 124 A
97 138 17 02C 0.77
<TS 125 A
98 139 15 02C
-0.14
<TS 126 A
99 104 17 02C
-0.87
<TS 127 A
99 104 13 02C 0.11
<TS 128 A
99 138 17 02C
-1
<TS 129 A
99 138 14 02C 0.08
<TS 130 A
100 103 21 02C 0.9
<TS 131 A
101 136 16 02C 0.11
<TS 132 A
107 134 25 02C
-1.01
<TS 133 A
112 37 20 02C
-0.92
<TS 134 A
115 38 20 02C
-0.91
<TS 135 A
115 38 14 02C 0.08
<15 136 A
116 39 28 02C
-0.82
<TS 137 A
117 40 13 02C
-0.11
<TS 15
No.
SG Row Column Depth in Percent Location Elevation Status 138 A
117 40 27 02C 0.89
<TS 139 A
117 120 15 02C 0.74
<TS 140 A
118 41 29 02C 0.14
<TS 141 A
124 119 7
02C
-0.9
<TS 142 A
126 111 12 02C
-1.04
<TS 143 A
126 115 18 02C
-0.85
<TS 144 A
126 115 11 02C 0.05
<TS 145 A
127 52 14 02C
-0.85
<TS 146 A
128 107 14 02C 0.98
<TS 147 A
129 54 27 02C
-0.91
<TS 148 A
129 110 22 02C 0.89
<TS 149 A
130 107 17 02C 0.82
<TS 150 A
134 103 16 02C
-0.9
<TS 151 A
135 100 19 02C 0.93
<TS 152 A
137 92 15 02C 0.81
<TS 153 A
12 137 10 02H
-0.77
<TS 154 A
13 2
12 02H
-1.08
<TS 155 A
13 2
23 02H 0.8
<TS 156 A
22 159 19 02H 0.81
<TS 157 A
26 5
19 02H
-0.95
<TS 158 A
26 5
17 02H
-0.16
<TS 159 A
28 53 18 02H 0.93
<TS 160 A
33 46 15 02H 0.85
<TS 161 A
38 47 13 02H 0.88
<TS 162 A
42 5
13 02H 0.78
<TS 163 A
55 80 13 02H 1.04
<TS 164 A
56 41 11 02H
-0.24
<TS 165 A
65 76 12 02H
-0.21
<TS 166 A
68 53 6
02H
-0.1
<TS 167 A
76 101 17 02H
-0.91
<TS 168 A
78 75 12 02H 0.19
<TS 169 A
83 76 16 02H 0.95
<TS 170 A
84 73 11 02H 0.21
<TS 171 A
88 73 19 02H
-0.08
<TS 172 A
96 25 18 02H 0.91
<TS 173 A
107 52 14 02H 0.99
<TS 174 A
116 45 16 02H 0.82
<TS 175 A
118 47 16 02H 0.97
<TS 176 A
128 53 22 02H
-0.87
<TS 177 A
129 56 17 02H 0.84
<TS 178 A
129 58 29 02H 0.92
<TS 179 A
130 55 16 02H 0.96
<TS 180 A
133 60 11 02H
-0.74
<TS 181 A
133 60 11 02H 1.01
<TS 182 A
11 146 13 03C 0.9
<TS 183 A
12 133 11 03C
-0.05
<TS 184 A
13 34 19 03C
-0.9
<TS 16
No.
SG Row Column Depth in Percent Location Elevation Status 185 A
33 124 16 03C 0.83
<TS 186 A
36 117 14 03C 0.03
<TS 187 A
37 38 19 03C 0.74
<TS 188 A
37 106 19 03C
-0.96
<TS 189 A
37 116 20 03C 0.9
<TS 190 A
39 42 16 03C
-0.65
<TS 191 A
39 104 16 03C
-0.63
<TS 192 A
39 126 18 03C 0.84
<TS 193 A
41 44 13 03C
-1
<TS 194 A
41 108 16 03C 0.88
<TS 195 A
41 120 12 03C 0.9
<TS 196 A
43 106 15 03C 0.73
<TS 197 A
44 109 17 03C 0.03
<TS 198 A
44 127 16 03C
-0.11
<TS 199 A
44 129 14 03C 0.92
<TS 200 A
45 108 20 03C 0.79
<TS 201 A
45 122 18 03C
-0.93
<TS 202 A
45 134 18 03C 0.74
<TS 203 A
47 34 14 03C 0.76
<TS 204 A
48 29 19 03C 0.93
<TS 205 A
49 28 16 03C 0.91
<TS 206 A
49 94 14 03C 0.16
<TS 207 A
49 96 15 03C 0.97
<TS 208 A
49 134 13 03C
-0.16
<TS 209 A
50 127 13 03C
-0.8
<TS 210 A
50 127 7
03C 0.19
<TS 211 A
51 102 7
03C
-1.05
<TS 212 A
51 102 5
03C
-0.25
<TS 213 A
51 102 16 03C 0.77
<TS 214 A
51 126 15 03C
-0.86
<TS 215 A
51 126 6
03C 1
<TS 216 A
52 31 17 03C 0.83
<TS 217 A
52 89 10 03C 0.76
<TS 218 A
53 88 10 03C
-0.92
<TS 219 A
53 92 17 03C 0.92
<TS 220 A
53 94 13 03C 0
<TS 221 A
53 104 15 03C 0.86
<TS 222 A
56 137 18 03C 0.19
<TS 223 A
58 143 13 03C 0.82
<TS 224 A
59 30 17 03C 0.85
<TS 225 A
59 114 16 03C 0.83
<TS 226 A
63 86 15 03C
-0.81
<TS 227 A
63 104 19 03C 0.82
<TS 228 A
63 118 17 03C 0.89
<TS 229 A
63 122 19 03C 0.87
<TS 230 A
63 134 12 03C 0.74
<TS 231 A
65 106 11 03C 0.83
<TS 17
No.
SG Row Column Depth in Percent Location Elevation Status 232 A
67 50 11 03C 0.11
<TS 233 A
67 50 11 03C 0.9
<TS 234 A
67 58 17 03C 0
<TS 235 A
67 118 14 03C 0.75
<TS 236 A
69 54 16 03C
-0.94
<TS 237 A
69 56 12 03C 0.74
<TS 238 A
69 132 15 03C 0.85
<TS 239 A
70 53 22 03C 0.11
<TS 240 A
70 55 20 03C
-0.69
<TS 241 A
71 54 14 03C 0.77
<TS 242 A
72 55 17 03C
-0.88
<TS 243 A
75 120 17 03C 0.85
<TS 244 A
76 53 14 03C 0.93
<TS 245 A
76 55 23 03C 0.72
<TS 246 A
77 124 15 03C
-0.87
<TS 247 A
77 124 19 03C 0.96
<TS 248 A
77 148 23 03C 0.82
<TS 249 A
79 94 11 03C
-0.94
<TS 250 A
79 116 15 03C
-1.05
<TS 251 A
80 119 14 03C 0.83
<TS 252 A
83 148 19 03C
-1.02
<TS 253 A
84 61 14 03C 0.11
<TS 254 A
84 61 29 03C 0.82
<TS 255 A
85 146 23 03C
-0.72
<TS 256 A
86 143 15 03C
-0.96
<TS 257 A
87 116 6
03C
-0.91
<TS 258 A
87 116 15 03C
-0.06
<TS 259 A
87 144 20 030
-0.86
<TS 260 A
88 61 21 030 0.55
<TS 261 A
90 93 22 030 0.64
<TS 262 A
90 143 15 030
-0.99
<TS 263 A
90 143 11 030
-0.08
<TS 264 A
91 90 20 030 0.7
<TS 265 A
93 136 19 030
-1.04
<TS 266 A
93 136 15 030 0.74
<TS 267 A
94 141 14 03C 0.93
<TS 268 A
95 134 14 03C
-1.2
<TS 269 A
97 140 13 03C
-0.91
<TS 270 A
98 135 15 03C
-0.03
<TS 271 A
99 140 12 03C
-0.94
<TS 272 A
99 140 18 03C
-0.14
<TS 273 A
100 89 15 03C 0.84
<TS 274 A
100 137 20 03C
-0.88
<TS 275 A
100 137 26 03C
-0.16
<TS 276 A
100 139 17 03C
-0.16
<15 277 A
101 120 12 03C 0.74
<TS 278 A
101 136 10 03C
-0.91
<TS 18
No.
SG Row Column Depth in Percent Location Elevation Status 279 A
102 133 14 03C
-0.94
<TS 280 A
102 135 17 03C 0
<TS 281 A
103 102 16 03C
-0.19
<TS 282 A
104 135 27 03C 0.82
<TS 283 A
105 132 22 03C 0.88
<TS 284 A
106 31 16 03C 1.01
<TS 285 A
106 35 21 03C 1
<TS 286 A
106 131 18 03C
-0.58
<TS 287 A
107 114 11 03C 0
<TS 288 A
108 119 14 03C 0.44
<TS 289 A
109 120 21 03C
-0.22
<TS 290 A
110 131 14 03C 0.98
<TS 291 A
111 116 12 03C 0.85
<TS 292 A
111 128 18 03C
-0.9
<TS 293 A
111 128 10 03C 0.54
<TS 294 A
114 119 10 03C 0.71
<TS 295 A
114 123 20 03C
-0.97
<TS 296 A
116 119 21 03C 0.73
<TS 297 A
117 110 16 03C 1.02
<TS 298 A
120 119 22 03C 0.71
<TS 299 A
121 116 18 03C 0.59
<TS 300 A
121 118 27 03C 0.96
<TS 301 A
123 112 12 03C 0.74
<TS 302 A
124 117 16 030 0.11
<TS 303 A
125 110 24 03C 1.08
<TS 304 A
125 112 18 03C
-0.03
<TS 305 A
126 109 15 03C 0.2
<TS 306 A
126 111 16 03C
-0.93
<TS 307 A
127 52 12 03C
-0.11
<TS 308 A
127 112 25 03C
-1.07
<TS 309 A
128 107 15 03C 0.74
<TS 310 A
130 99 9
03C
-0.93
<TS 311 A
130 99 28 03C
-0.16
<TS 312 A
130 107 15 03C
-0.27
<TS 313 A
132 107 17 03C
-0.9
<TS 314 A
132 107 15 03C 0.92
<TS 315 A
32 37 7
03H 0.16
<TS 316 A
32 37 13 03H 0.95
<TS 317 A
38 35 22 03H 0.9
<TS 318 A
38 127 16 03H 0.96
<TS 319 A
41 34 15 03H
-0.79
<TS 320 A
45 52 16 03H 0.88
<TS 321 A
45 128 12 03H 0
<TS 322 A
46 37 12 03H 0.83
<TS 323 A
46 51 15 03H 0.85
<TS 324 A
50 45 12 03H 0.92
<TS 325 A
50 51 13 03H 0.9
<TS 19
No.
SG Row Column Depth in Percent Location Elevation Status 326 A
53 56 16 03H 0.96
<TS 327 A
53 80 11 03H
-0.93
<TS 328 A
53 80 13 03H 0.93
<TS 329 A
54 39 12 03H 0.8
<TS 330 A
54 83 19 03H 1
<TS 331 A
56 27 13 03H
-0.93
<TS 332 A
58 85 17 03H 1.07
<TS 333 A
59 38 15 03H 0.96
<TS 334 A
59 82 14 03H 1.02
<TS 335 A
62 33 17 03H 0.88
<TS 336 A
62 35 14 03H 0.82
<TS 337 A
63 82 20 03H 0.78
<TS 338 A
64 83 10 03H 0.91
<TS 339 A
65 108 16 03H
-0.79
<TS 340 A
66 35 15 03H 0.87
<TS 341 A
66 107 15 03H 0.24
<TS 342 A
66 109 13 03H
-0.82
<TS 343 A
66 113 16 03H 0.82
<TS 344 A
67 12 11 03H 0.82
<TS 345 A
67 106 14 03H 0.9
<TS 346 A
68 81 3
03H
-1.02
<TS 347 A
68 81 16 03H 0.88
<TS 348 A
68 107 11 03H
-0.16
<TS 349 A
70 85 13 03H 0.95
<TS 350 A
74 77 14 03H 0.79
<TS 351 A
74 121 9
03H
-0.83
<TS 352 A
75 82 14 03H 0.77
<TS 353 A
75 100 7
03H
-0.99
<TS 354 A
75 100 17 03H 0.95
<TS 355 A
76 103 12 03H
-0.08
<TS 356 A
77 102 13 03H 0.94
<TS 357 A
79 82 18 03H 1.01
<TS 358 A
79 100 14 03H 0.93
<TS 359 A
85 26 18 03H 0.89
<TS 360 A
86 97 18 03H 0.99
<TS 361 A
89 136 14 03H 0.93
<TS 362 A
92 125 10 03H 0.87
<TS 363 A
93 130 16 03H
-0.74
<TS 364 A
102 117 19 03H 0.97
<TS 365 A
107 134 14 03H 0.84
<TS 366 A
117 120 14 03H 1.01
<TS 367 A
124 51 16 03H 0.91
<TS 368 A
126 51 23 03H 0.86
<TS 369 A
133 62 16 03H 0.78
<TS 370 A
34 63 13 04C 0.87
<TS 371 A
38 51 27 04C 0.99
<TS 372 A
41 54 12 04C
-0.72
<TS 20
No.
SG Row Column Depth in Percent Location Elevation Status 373 A
43 44 13 040 1.01
<TS 374 A
46 141 15 04C 0.83
<TS 375 A
47 126 13 04C 0.11
<TS 376 A
49 122 11 04C
-0.85
<TS 377 A
49 122 10 04C 0.79
<TS 378 A
50 29 14 04C 0.86
<TS 379 A
50 123 17 04C
-0.05
<TS 380 A
51 90 16 04C
-0.13
<TS 381 A
51 124 13 04C
-0.91
<TS 382 A
53 122 6
04C
-0.85
<TS 383 A
53 122 12 04C 0.88
<TS 384 A
54 143 11 04C 0.8
<TS 385 A
56 141 14 04C 0.9
<TS 386 A
58 127 8
04C 0
<TS 387 A
58 127 21 04C 0.82
<TS 388 A
59 144 13 04C 0.8
<TS 389 A
61 138 15 04C 0.87
<TS 390 A
63 104 13 04C
-0.16
<TS 391 A
63 124 10 04C
-0.14
<TS 392 A
63 124 14 04C 0.91
<TS 393 A
63 126 16 04C 0.75
<TS 394 A
63 142 13 04C 0.88
<TS 395 A
64 123 14 04C 0.77
<TS 396 A
65 106 16 04C 0.8
<TS 397 A
65 138 27 04C
-0.14
<TS 398 A
66 89 14 04C
-0.94
<TS 399 A
66 109 15 04C 0.14
<TS 400 A
66 109 16 04C 0.88
<TS 401 A
67 154 11 04C 0.82
<TS 402 A
70 107 16 04C
-1.01
<TS 403 A
70 119 14 04C 0.8
<TS 404 A
71 108 12 04C 0.08
<TS 405 A
72 55 15 04C
-0.19
<TS 406 A
72 127 15 04C 0.96
<TS 407 A
74 123 17 04C 0.93
<TS 408 A
75 150 12 04C 0.97
<TS 409 A
76 51 13 04C 0
<TS 410 A
76 97 8
04C
-0.83
<TS 411 A
76 97 11 04C 0.83
<TS 412 A
76 111 16 04C 0.83
<TS 413 A
79 48 15 04C
-0.16
<TS 414 A
79 90 11 04C
-1.02
<TS 415 A
79 90 19 04C
-0.22
<TS 416 A
79 128 22 04C 0.88
<TS 417 A
81 118 8
04C
-0.88
<TS 418 A
81 118 6
04C 0.99
<TS 419 A
83 88 8
04C
-0.34
<TS 21
No.
SG Row Column Depth in Percent Location Elevation Status 420 A
83 88 18 04C 0.79
<TS 421 A
84 141 20 04C 0.75
<TS 422 A
86 145 20 04C 0.72
<TS 423 A
87 56 14 04C 0.8
<TS 424 A
87 92 20 04C 0.81
<TS 425 A
87 116 20 04C 0.8
<15 426 A
87 124 15 04C
-0.85
<TS 427 A
88 59 15 04C 0.8
<TS 428 A
88 125 13 04C
-1.02
<TS 429 A
88 145 23 04C
-0.95
<TS 430 A
90 95 18 04C 0.85
<TS 431 A
90 135 17 04C 0.88
<TS 432 A
91 136 10 04C 0.88
<TS 433 A
91 138 6
04C
-1.06
<TS 434 A
91 138 11 04C 0.85
<TS 435 A
92 89 21 04C 0.77
<TS 436 A
92 133 17 04C 0.95
<15 437 A
92 135 16 04C 0.85
<TS 438 A
92 137 11 04C 0.74
<TS 439 A
94 51 17 04C 0.86
<TS 440 A
94 101 21 04C
-1.01
<TS 441 A
94 135 13 04C 0.74
<TS 442 A
95 134 25 04C
-0.93
<TS 443 A
95 140 19 04C 0.71
<TS 444 A
96 59 19 04C
-0.87
<TS 445 A
96 63 22 04C 0.88
<TS 446 A
96 111 14 04C 0.17
<TS 447 A
96 111 13 04C 1.07
<TS 448 A
96 131 17 04C
-0.82
<TS 449 A
98 103 19 04C
-0.99
<TS 450 A
98 103 17 04C 0.91
<TS 451 A
98 105 21 04C 0.93
<TS 452 A
98 133 14 04C 0.9
<TS 453 A
99 112 19 04C 0.72
<TS 454 A
100 107 7
04C
-0.17
<TS 455 A
100 107 13 04C 0.95
<TS 456 A
100 137 12 04C 0.87
<TS 457 A
101 106 15 04C 0.85
<TS 458 A
102 89 22 04C 0.83
<TS 459 A
102 135 17 04C 0.76
<TS 460 A
103 134 17 04C 0.05
<TS 461 A
103 134 15 04C 0.82
<TS 462 A
104 87 23 04C
-0.75
<TS 463 A
104 87 14 04C
-0.14
<TS 464 A
104 97 20 04C
-1.05
<TS 465 A
104 123 18 04C 0.87
<TS 466 A
106 31 20 04C 0.92
<TS 22
No.
SG Row Column Depth in Percent Location Elevation Status 467 A
106 47 14 04C
-0.05
<TS 468 A
106 47 15 04C 0.74
<TS 469 A
106 121 10 04C 0.06
<TS 470 A
106 121 16 04C 0.94
<TS 471 A
107 98 12 04C
-0.16
<TS 472 A
107 128 13 04C
-1.08
<TS 473 A
108 133 17 04C
-0.93
<TS 474 A
108 133 14 04C 0.82
<TS 475 A
109 118 15 04C
-1.03
<TS 476 A
109 132 20 04C 0.85
<TS 477 A
111 104 12 04C
-0.17
<TS 478 A
111 126 5
04C 0.08
<TS 479 A
111 126 17 04C 0.81
<TS 480 A
111 130 22 04C
-0.31
<TS 481 A
113 118 15 04C 0.08
<TS 482 A
114 121 11 04C 0.86
<TS 483 A
116 121 7
04C 0
<TS 484 A
116 121 25 04C 0.99
<TS 485 A
119 110 18 04C
-0.99
<TS 486 A
120 115 14 04C 0.77
<TS 487 A
120 117 15 04C 0.67
<TS 488 A
121 116 11 04C
-0.91
<TS 489 A
122 105 13 04C 0
<TS 490 A
125 112 12 04C
-1.1
<TS 491 A
126 115 16 04C 0.69
<TS 492 A
129 110 18 04C 0
<TS 493 A
134 99 15 04C
-1.01
<TS 494 A
135 100 16 04C
-0.98
<TS 495 A
137 92 15 04C 0.78
<TS 496 A
1 160 11 04H
-0.21
<TS 497 A
4 163 19 04H
-1.17
<TS 498 A
17 2
13 04H 0.87
<TS 499 A
37 36 10 04H
-0.95
<TS 500 A
37 36 13 04H
-0.32
<TS 501 A
37 50 11 04H
-0.8
<TS 502 A
37 50 15 04H 0.93
<TS 503 A
37 56 23 04H 1
<TS 504 A
37 62 19 04H 1.08
<TS 505 A
38 35 26 04H 0.9
<TS 506 A
39 104 15 04H 0.88
<TS 507 A
39 120 19 04H 0.98
<TS 508 A
42 43 20 04H 0.87
<TS 509 A
42 59 16 04H 0.99
<TS 510 A
44 49 19 04H 0.8
<TS 511 A
45 30 17 04H
-0.87
<TS 512 A
45 30 11 04H
-0.16
<TS 513 A
46 41 12 04H 0.82
<TS 23
No.
SG Row Column Depth in Percent Location Elevation Status 514 A
47 24 11 04H
-0.78 -
TS 515 A
47 70 17 04H 0.98
<TS 516 A
50 39 11 04H 0.88 -
TS 517 A
51 66 11 04H
-0.74
<TS 518 A
54 83 15 04H
-0.1
<TS 519 A
55 46 14 04H
-1
<TS 520 A
56 39 12 04H
-0.19
<TS 521 A
60 29 21 04H 0.81
<TS 522 A
62 59 13 04H 0.95
<TS 523 A
62 73 13 04H
-0.11
<TS 524 A
63 66 14 04H
-0.82
<TS 525 A
63 102 15 04H 0.91
<TS 526 A
64 13 18 04H 0.87
<TS 527 A
66 31 20 04H 0.9
<TS 528 A
66 35 17 04H 0.92
<TS 529 A
66 61 12 04H 0.79
<TS 530 A
68 41 13 04H 0.93
<15 531 A
68 53 13 04H
-0.1
<TS 532 A
69 40 14 04H 0.93
<TS 533 A
69 76 14 04H
-0.83
<TS 534 A
69 102 13 04H 1.01
<TS 535 A
69 108 15 04H 1.08
<TS 536 A
71 54 14 04H 0.95
<TS 537 A
71 110 6
04H
-0.95
<TS 538 A
71 110 16 04H 0.87
<TS 539 A
73 44 15 04H 0.8
<15 540 A
77 114 16 04H 0.96
<TS 541 A
79 72 15 04H 0.86
<TS 542 A
79 120 10 04H 0.87
<TS 543 A
80 57 13 04H 0
<TS 544 A
80 57 15 04H 0.87
<TS 545 A
80 77 23 04H 0.8
<TS 546 A
83 100 20 04H 0.91
<TS 547 A
84 85 13 04H
-0.93
<TS 548 A
84 85 18 04H 0.89
<TS 549 A
86 101 15 04H
-0.8
<TS 550 A
87 100 17 04H 0.99
<TS 551 A
88 83 15 04H
-0.7
<TS 552 A
89 84 12 04H
-0.86
<TS 553 A
90 59 10 04H
-0.11
<TS 554 A
90 59 13 04H 0.92
<TS 555 A
90 135 12 04H 0.99
<TS 556 A
92 93 16 04H 0.92
<TS 557 A
92 131 15 04H 0.97
<TS 558 A
93 116 11 04H 0.98
<TS 559 A
95 130 13 04H 1.01
<TS 560 A
96 69 13 04H 0.85
<TS 24
No.
SG Row Column Depth in Percent Location Elevation Status 561 A
100 29 15 04H 0.85
<TS 562 A
101 30 21 04H
-0.13
<TS 563 A
102 119 28 04H 0.86
<TS 564 A
106 101 17 04H 0.99
<TS 565 A
109 116 14 04H
-0.68
<TS 566 A
112 103 8
04H 0.13
<TS 567 A
112 103 16 04H 0.96
<TS 568 A
118 101 11 04H 0.03
<TS 569 A
2 127 19 05C 0.75
<TS 570 A
34 131 11 05C
-0.25
<TS 571 A
37 24 16 05C 0.81
<TS 572 A
41 44 12 05C
-0.87
<TS 573 A
42 35 9
05C
-0.03
<TS 574 A
42 35 15 05C 0.94
<TS 575 A
44 49 19 05C
-0.88
<TS 576 A
44 131 13 05C 0.82
<TS 577 A
63 104 14 05C
-0.87
<TS 578 A
64 59 15 05C 0.86
<TS 579 A
67 106 11 05C 0.77
<TS 580 A
69 106 12 05C 0.91
<TS 581 A
71 108 12 05C 0.85
<TS 582 A
71 126 8
05C 0.17
<TS 583 A
71 126 19 05C 0.75
<TS 584 A
72 85 12 05C 0
<TS 585 A
73 56 13 05C
-0.86
<TS 586 A
76 111 9
05C 0.83
<TS 587 A
77 82 13 05C 0.83
<TS 588 A
81 54 16 05C
-1.05
<TS 589 A
81 148 21 05C 0.03
<TS 590 A
83 102 12 05C
-0.98
<TS 591 A
83 102 15 05C
-0.27
<TS 592 A
84 73 10 05C 0.11
<TS 593 A
84 73 16 05C 0.85
<TS 594 A
86 111 15 05C 0.84
<TS 595 A
87 82 13 05C 0.88
<TS 596 A
88 59 17 05C 0.22
<TS 597 A
88 59 20 05C 0.94
<TS 598 A
89 70 14 05C
-0.83
<TS 599 A
89 70 9
05C 0.22
<TS 600 A
90 105 20 05C 0.93
<TS 601 A
90 107 13 05C 0.14
<TS 602 A
90 107 16 05C 0.99
<TS 603 A
91 48 14 05C
-0.88
<TS 604 A
91 66 18 05C 0.94
<TS 605 A
91 80 13 05C 0.86
<TS 606 A
91 94 14 05C 0
<TS 607 A
92 69 15 05C 0.2
<TS 25
No.
SG Row Column Depth in Percent Location Elevation Status 608 A
92 69 13 05C 1.01
<TS 609 A
92 77 14 05C
-0.85
<TS 610 A
92 83 13 05C 0.87
<TS 611 A
92 87 17 05C 0.89
<TS 612 A
92 89 16 05C 0.91
<TS 613 A
92 109 11 05C
-0.91
<TS 614 A
93 138 15 05C 0.68
<TS 615 A
94 71 10 05C
-1
<TS 616 A
95 84 18 05C 0.82
<TS 617 A
96 87 18 05C 0.89
<TS 618 A
96 97 14 05C 0.85
<TS 619 A
96 103 14 05C 0.94
<TS 620 A
96 111 18 05C 0.83
<TS 621 A
97 54 17 05C
-0.11
<TS 622 A
97 54 15 05C 0.76
<TS 623 A
97 62 18 05C
-0.75
<TS 624 A
97 82 18 05C 0.83
<TS 625 A
97 116 16 05C 0.11
<TS 626 A
97 116 21 05C 0.72
<TS 627 A
98 51 16 05C 0.81
<TS 628 A
98 105 19 05C
-0.99
<TS 629 A
98 109 19 05C 1.01
<TS 630 A
100 131 13 05C 0.88
<TS 631 A
100 137 15 05C
-0.98
<TS 632 A
101 104 13 05C
-0.05
<TS 633 A
102 95 17 05C
-0.19
<TS 634 A
102 105 16 05C 0.82
<TS 635 A
103 92 16 05C 0.92
<TS 636 A
103 96 17 05C 0.82
<TS 637 A
103 100 11 05C
-0.99
<TS 638 A
104 133 15 05C
-0.22
<TS 639 A
105 90 18 05C 0.95
<TS 640 A
106 121 16 05C 0.06
<TS 641 A
108 87 17 05C 0.89
<TS 642 A
108 117 16 05C 0.99
<TS 643 A
110 109 14 05C 0.82
<TS 644 A
112 127 17 05C
-0.85
<TS 645 A
116 53 14 05C 0.88
<TS 646 A
116 111 17 05C
-0.08
<TS 647 A
120 121 22 05C 0.93
<TS 648 A
122 111 16 05C
-0.93
<TS 649 A
123 48 14 05C 0.82
<TS 650 A
126 109 13 05C 0.06
<TS 651 A
126 109 15 05C 1.05
<TS 652 A
127 108 17 05C
-0.88
<TS 653 A
128 111 17 05C 0.71
<TS 654 A
133 104 11 05C 0.03
<TS 26
No.
SG Row Column Depth in Percent Location Elevation Status 655 A
133 104 14 05C 0.87
<TS 656 A
137 92 29 05C 0.06
<TS 657 A
4 163 20 05H 0.47
<TS 658 A
8 149 18 05H 0.76
<TS 659 A
37 30 6
05H
-0.95
<TS 660 A
37 30 11 05H 1.12
<TS 661 A
37 56 14 05H 1.03
<TS 662 A
37 134 10 05H 0.92
<TS 663 A
38 17 18 05H
-0.18
<TS 664 A
38 35 13 05H 0.05
<TS 665 A
38 35 16 05H 0.81
<TS 666 A
39 62 11 05H 0.13
<TS 667 A
39 62 15 05H 1.04
<TS 668 A
40 59 16 05H 0.92
<15 669 A
41 20 15 05H 0.81
<TS 670 A
41 60 24 05H 0.86
<TS 671 A
51 66 10 05H 0.92
<TS 672 A
51 70 13 05H 0.95
<TS 673 A
51 116 12 05H 1.04
<TS 674 A
62 49 18 05H 0.89
<TS 675 A
66 45 13 05H 0.98
<TS 676 A
66 75 12 05H 0.93
<TS 677 A
67 14 26 05H 0.8
<TS 678 A
70 69 15 05H
-0.11
<TS 679 A
73 14 14 05H
-0.9
<TS 680 A
77 100 15 05H
-0.08
<TS 681 A
79 100 10 05H 0.96
<TS 682 A
79 104 5
05H
-0.27
<TS 683 A
79 104 15 05H 0.81
<TS 684 A
81 100 14 05H 0.94
<TS 685 A
82 121 11 05H 0.86
<TS 686 A
83 74 13 05H 0.74
<TS 687 A
87 82 18 05H 0.9
<TS 688 A
87 102 21 05H 0.98
<TS 689 A
88 83 15 05H
-0.73
<TS 690 A
89 112 13 05H
-1.13
<TS 691 A
89 112 15 05H 0.2
<TS 692 A
89 112 15 05H 0.98
<TS 693 A
89 128 15 05H 0.9
<TS 694 A
91 86 14 05H 0.19
<TS 695 A
91 92 13 05H 1.02
<TS 696 A
91 94 12 05H 0
<TS 697 A
92 83 11 05H
-0.03
<TS 698 A
96 65 13 05H
-1.02
<TS 699 A
96 87 16 05H 0.84
<TS 700 A
98 55 18 05H 0.97
<TS 701 A
100 29 16 05H 0.87
<TS 27
No.
SG Row Column Depth in Percent Location Elevation Status 702 A
100 115 16 05H
-0.85
<TS 703 A
101 70 13 05H 0.86
<TS 704 A
103 82 13 05H
-0.8
<TS 705 A
103 82 19 05H
-0.13
<TS 706 A
105 112 19 05H 1
<TS 707 A
106 45 13 05H
-0.08
<TS 708 A
107 44 13 05H
-0.82
<TS 709 A
107 44 16 05H
-0.08
<TS 710 A
108 115 17 05H 0.86
<TS 711 A
116 81 14 05H 0.84
<TS 712 A
117 82 16 05H
-0.9
<TS 713 A
126 115 11 05H 0.99
<TS 714 A
133 64 17 05H
-0.19
<TS 715 A
52 89 14 06C 0.66
<TS 716 A
55 140 22 06C
-0.25
<TS 717 A
63 52 16 06C 0.77
<TS 718 A
64 57 12 06C 0.79
<TS 719 A
65 56 15 06C 0.8
<TS 720 A
65 126 15 06C
-0.75
<TS 721 A
66 27 14 06C 0.84
<TS 722 A
66 59 17 06C 0.83
<TS 723 A
66 83 13 06C 0.87
<TS 724 A
67 30 14 06C
-0.96
<TS 725 A
69 86 18 06C 0.83
<TS 726 A
69 134 17 06C
-1.06
<TS 727 A
71 78 14 06C
-0.9
<TS 728 A
73 44 18 06C
-0.85
<TS 729 A
73 134 16 06C
-0.87
<TS 730 A
75 16 17 06C 0.06
<TS 731 A
77 122 18 06C 0.85
<TS 732 A
86 63 15 06C 0.7
<TS 733 A
89 70 16 06C 0.98
<TS 734 A
90 95 19 06C 0.88
<TS 735 A
90 137 14 06C 0.81
<TS 736 A
91 134 13 06C
-0.03
<TS 737 A
92 77 13 06C
-0.91
<TS 738 A
95 48 21 06C 0.98
<TS 739 A
96 61 19 06C 0.08
<TS 740 A
97 62 20 06C 0.85
<TS 741 A
97 64 18 06C
-1.01
<TS 742 A
98 75 20 06C 0.8
<TS 743 A
98 85 16 06C 0.74
<TS 744 A
98 87 12 06C
-0.89
<TS 745 A
98 87 23 06C 0.87
<TS 746 A
98 103 18 06C
-0.94
<TS 747 A
100 41 10 06C 0.72
<TS 748 A
100 75 11 06C 0.88
<TS 28
No.
SG Row Column Depth in Percent Location Elevation Status 749 A
104 99 15 06C 0.74
<TS 750 A
106 117 15 06C
-1.16
<TS 751 A
108 89 14 06C
-0.96
<15 752 A
110 79 14 06C
-0.19
<TS 753 A
111 44 19 06C
-0.19
<TS 754 A
116 123 18 06C
-0.08
<TS 755 A
117 58 16 06C 0.77
<TS 756 A
118 51 17 06C 0.91
<TS 757 A
119 52 24 06C 0.82
<TS 758 A
120 81 14 06C 0.85
<TS 759 A
120 93 16 06C 0.75
<TS 760 A
121 50 14 06C 0.82
<TS 761 A
127 80 18 06C 0.82
<TS 762 A
131 96 22 06C 0.77
<TS 763 A
132 99 12 06C 0.94
<TS 764 A
133 104 12 06C
-0.22
<TS 765 A
136 75 12 06C 0.75
<TS 766 A
136 91 21 06C
-1.04
<TS 767 A
136 91 16 06C
-0.22
<TS 768 A
137 92 14 06C
-1.16
<TS 769 A
44 123 19 06H 0
<TS 770 A
51 30 12 06H
-0.97
<TS 771 A
52 19 12 06H
-0.05
<TS 772 A
52 33 11 06H 0.98
<TS 773 A
55 106 11 06H 0.89
<TS 774 A
59 50 15 06H 0.77
<TS 775 A
59 126 11 06H 0.88
<TS 776 A
61 48 16 06H 0.84
<TS 777 A
63 82 8
06H 0.93
<TS 778 A
64 19 11 06H 0.03
<TS 779 A
65 12 21 06H 0.75
<TS 780 A
67 24 9
06H 0.05
<TS 781 A
67 24 24 06H 0.73
<TS 782 A
67 38 7
06H 0.03
<TS 783 A
67 38 14 06H 0.89
<TS 784 A
67 120 12 06H 0
<TS 785 A
67 120 13 06H 0.99
<TS 786 A
68 45 16 06H 0.78
<TS 787 A
69 60 13 06H 0.85
<TS 788 A
87 104 12 06H 0.91
<TS 789 A
89 108 26 06H 0.94
<TS 790 A
92 81 15 06H
-0.75
<TS 791 A
92 89 15 06H 0.88
<TS 792 A
96 61 13 06H 0.96
<TS 793 A
99 70 13 06H
-0.3
<TS 794 A
100 29 18 06H 0.81
<TS 795 A
101 112 13 06H 0.96
<TS 29
No.
SG Row Column Depth in Percent Location Elevation Status 796 A
103 82 8
06H 0.08
<TS 797 A
103 82 15 06H 0.95
<TS 798 A
114 75 13 06H 0.85
<TS 799 A
115 78 19 06H
-0.82
<TS 800 A
121 120 14 06H 0.8
<TS 801 A
122 53 14 06H 0.81
<TS 802 A
80 99 12 07C 1.01
<TS 803 A
81 84 20 07C
-0.27
<TS 804 A
81 102 16 07C
-0.88
<TS 805 A
81 102 11 07C
-0.19
<TS 806 A
82 79 14 07C 0.72
<TS 807 A
87 40 16 07C 0.79
<TS 808 A
88 53 22 07C 0.78
<TS 809 A
88 57 19 07C 0.81
<TS 810 A
91 48 19 07C 0.05
<TS 811 A
94 95 18 07C
-0.83
<TS 812 A
95 72 16 07C 0
<TS 813 A
95 72 14 07C 0.76
<TS 814 A
95 132 14 07C
-1.01
<TS 815 A
97 58 19 07C 0.98
<TS 816 A
101 124 18 07C 0.79
<TS 817 A
102 67 11 07C 0.15
<TS 818 A
102 73 16 07C
-0.91
<TS 819 A
103 108 14 07C
-0.19
<TS 820 A
103 108 7
07C 0.8
<TS 821 A
103 122 11 07C 0.92
<TS 822 A
104 63 15 07C
-0.82
<TS 823 A
109 90 9
07C
-0.85
<TS 824 A
109 90 15 07C
-0.08
<TS 825 A
114 119 13 07C 0.71
<TS 826 A
116 95 14 07C
-0.91
<TS 827 A
120 77 10 07C 0.11
<TS 828 A
120 81 20 07C 0.03
<TS 829 A
120 81 19 07C 0.8
<TS 830 A
126 111 11 07C 0.78
<TS 831 A
128 77 17 07C 0.98
<TS 832 A
133 104 13 07C 0.82
<TS 833 A
136 79 14 07C
-0.84
<TS 834 A
136 79 29 07C
-0.11
<TS 835 A
136 91 18 07C
-0.83
<TS 836 A
137 92 19 07C
-0.89
<TS 837 A
138 75 13 07C 0.88
<TS 838 A
77 148 16 07H
-0.75
<TS 839 A
79 68 18 07H 1.08
<TS 840 A
80 147 17 07H 0.82
<TS 841 A
87 40 17 07H
-0.8
<TS 842 A
87 40 10 07H
-0.11
<TS 30
No.
SG Row Column Depth in Percent Location Elevation Status 843 A
89 78 10 07H
-0.79
<TS 844 A
89 78 18 07H 0.82
<TS 845 A
92 133 15 07H 0.9
<TS 846 A
97 70 12 07H 0.64
<TS 847 A
98 111 14 07H 0.16
<TS 848 A
98 127 19 07H 0.75
<TS 849 A
116 51 19 07H 0.99
<TS 850 A
125 112 20 07H
-0.11
<TS 851 A
126 83 14 07H 0.08
<TS 852 A
129 58 14 07H
-1.02
<TS 853 A
133 62 20 07H
-0.94
<TS 854 A
133 62 11 07H 0.88
<TS 855 A
134 65 21 07H
-0.25
<TS 856 A
138 75 12 07H
-1
<TS 857 A
138 75 15 07H 0.9
<TS 858 A
114 37 16 08C 0.78
<TS 859 A
126 61 7
08C
-0.83
<TS 860 A
129 108 12 08C 0.83
<TS 861 A
132 97 11 08C 0.14
<TS 862 A
133 104 12 08C
-0.57
<TS 863 A
133 104 12 08C 0.75
<TS 864 A
135 78 24 08C
-1.03
<TS 865 A
135 78 12 08C 0.86
<TS 866 A
135 90 21 08C 0.82
<TS 867 A
136 79 17 08C
-0.78
<TS 868 A
136 91 21 08C
-0.88
<TS 869 A
136 91 30 08C 0.92
<TS 870 A
137 92 19 08C
-0.86
<TS 871 A
137 92 25 08C 0.94
<TS 872 A
138 75 14 08C
-1
<TS 873 A
138 75 17 08C 0.11
<TS 874 A
138 81 19 08C
-0.99
<TS 875 A
138 85 15 08C
-0.14
<TS 876 A
138 85 12 08C 0.76
<TS 877 A
138 87 15 08C 0.8
<TS 878 A
110 123 18 08H
-0.97
<TS 879 A
114 129 13 08H
-0.77
<TS 880 A
126 69 12 08H
-0.99
<TS 881 A
128 69 18 08H 0.88
<TS 882 A
130 57 21 08H 0.84
<TS 883 A
131 94 14 08H
-0.8
<TS 884 A
131 94 18 08H 1
<TS 885 A
133 84 18 08H
-0.05
<TS 886 A
134 65 15 08H 0.88
<TS 887 A
135 82 18 08H 0.68
<TS 888 A
136 85 17 08H
-1.05
<TS 889 A
138 83 15 08H
-1.12
<TS 31
No.
SG Row Column Depth in Percent Location Elevation Status 890 A
138 83 11 08H
-0.05
<TS 891 A
138 85 18 08H
-1.04
<TS 892 A
7 124 6
DBC
-1.09
<TS 893 A
9 32 16 DBC 1.11
<TS 894 A
19 64 20 DBC
-1.54
<TS 895 A
32 161 17 DBC
-0.38
<TS 896 A
34 63 15 DBC 1.67
<TS 897 A
37 34 20 DBC 1.65
<TS 898 A
39 130 10 DBC
-1.46
<TS 899 A
42 33 14 DBC
-1.62
<TS 900 A
43 126 12 DBC 1.19
<TS 901 A
51 18 8
DBC 1.49
<TS 902 A
53 136 9
DBC 1.94
<TS 903 A
55 40 9
DBC 1.56
<TS 904 A
60 33 14 DBC 1.98
<TS 905 A
70 81 17 DBC 1.73
<TS 906 A
70 145 10 DBC
-1.84
<TS 907 A
72 143 20 DBC 1.83
<TS 908 A
76 15 31 DBC
-1.51
<TS 909 A
76 15 12 DBC 1.77
<TS 910 A
76 19 12 DBC 1.86
<TS 911 A
77 50 12 DBC
-0.99
<TS 912 A
81 22 11 DBC
-1.58
<TS 913 A
97 48 12 DBC 1.74
<TS 914 A
98 55 13 DBC
-1.99
<TS 915 A
103 122 18 DBC 1.42
<TS 916 A
104 103 10 DBC
-1.46
<TS 917 A
106 133 20 DBC 1.69
<TS 918 A
130 89 11 DBC
-1.71
<TS 919 A
131 70 13 DBC 1.6
<TS 920 A
132 81 14 DBC 1.38
<TS 921 A
132 91 19 DBC
-1.65
<TS 922 A
132 99 16 DBC 1.7
<TS 923 A
134 77 15 DBC
-2.11
<TS 924 A
134 77 15 DBC 1.77
<TS 925 A
134 89 14 DBC
-1.97
<TS 926 A
134 91 32 DBC 1.96
<TS 927 A
134 103 14 DBC
-1.66
<TS 928 A
135 76 17 DBC 1.92
<TS 929 A
135 86 17 DBC
-1.17
<TS 930 A
135 94 27 DBC
-0.78
<TS 931 A
135 100 12 DBC
-1.75
<TS 932 A
135 100 19 DBC 1.63
<TS 933 A
136 69 13 DBC
-1.52
<TS 934 A
136 77 23 DBC 1.84
<TS 935 A
138 85 18 DBC
-1.61
<TS 936 A
2 127 12 DBH 0.57
<TS 32
No.
SG Row Column Depth in Percent Location Elevation Status 937 A
4 19 16 DBH 0.25 -
TS 938 A
10 165 14 DBH 1.32
<TS 939 A
19 64 18 DBH
-1.38
<TS 940 A
21 64 12 DBH
-1.38
<TS 941 A
42 33 9
DBH
-1.91
<TS 942 A
42 123 18 DBH
-0.13
<TS 943 A
44 109 17 DBH
-2.19
<TS 944 A
61 144 12 DBH 1.72
<TS 945 A
63 84 11 DBH
-1.67
<TS 946 A
68 141 20 DBH 2.13
<TS 947 A
70 57 12 DBH
-1.69
<TS 948 A
72 149 18 DBH 1.94
<TS 949 A
79 16 13 DBH
-1.23
<TS 950 A
80 107 20 DBH 1.76
<TS 951 A
104 71 12 DBH 1.58
<TS 952 A
107 120 15 DBH 1.74
<TS 953 A
108 65 16 DBH 1.69
<TS 954 A
110 131 24 DBH
-1.75
<TS 955 A
112 37 18 DBH
-1.73
<TS 956 A
114 37 31 DBH 1.28
<TS 957 A
128 85 17 DBH 1.89
<TS 958 A
134 65 15 DBH
-1.97
<TS 959 A
138 75 27 DBH 1.64
<TS 960 A
138 81 28 DBH 1.88
<TS 961 A
138 83 24 DBH 2.06
<TS 962 A
115 92 25 VS1 0.77
<TS 963 A
116 89 22 VS1 0.86
<TS 964 A
122 117 13 VS1 1.03
<TS 965 A
126 77 14 VS1
-0.77
<TS 966 A
126 77 13 VS1 1.05
<TS 967 A
127 56 14 VS1
-0.92
<TS 968 A
127 76 15 VS1
-0.87
<TS 969 A
128 71 21 VS1
-0.79
<TS 970 A
128 71 31 VS1 0.98
<TS 971 A
129 74 17 VS1
-0.87
<TS 972 A
131 94 16 VS1 0.84
<TS 973 A
133 64 13 VS1 0.87
<TS 974 A
134 71 20 VS1
-0.23
<TS 975 A
134 71 17 VS1 0.31
<TS 976 A
134 71 21 VS1 0.85
<TS 977 A
135 72 26 VS1
-1.06
<TS 978 A
135 72 18 VS1 0.89
<TS 979 A
135 78 17 VS1 0.94
<TS 980 A
137 74 15 VS1
-0.39
<TS 981 A
137 74 19 VS1 0.28
<TS 982 A
137 74 17 VS1 0.81
<TS 983 A
138 81 16 VS1
-0.86
<TS 33
No.
SG Row Column Depth in Percent Location Elevation Status 984 A
138 81 7
VS1 1
<TS 985 A
138 83 13 VS1
-0.67
<TS 986 A
83 114 13 VS2
-0.93
<TS 987 A
83 114 5
VS2 0.89
<TS 988 A
83 130 13 VS2 0.98
<TS 989 A
84 19 15 VS2 0.65
<TS 990 A
84 29 18 VS2 0.89
<TS 991 A
84 33 19 VS2
-0.72
<TS 992 A
84 37 17 VS2
-0.77
<TS 993 A
84 39 10 VS2
-0.79
<TS 994 A
84 53 25 VS2
-0.76
<TS 995 A
84 99 18 VS2
-0.9
<TS 996 A
87 58 15 VS2
-0.6
<TS 997 A
87 60 17 VS2
-0.84
<TS 998 A
87 120 14 VS2 0.11
<TS 999 A
87 120 16 VS2 0.95
<TS 1000 A
90 115 19 VS2
-0.65
<TS 1001 A
90 115 11 VS2 0.81
<TS 1002 A
91 114 17 VS2
-0.91
<TS 1003 A
91 116 24 VS2
-0.7
<TS 1004 A
92 23 18 VS2 0.66
<TS 1005 A
92 23 19 VS2 1.07
<TS 1006 A
92 101 17 VS2
-0.72
<TS 1007 A
92 101 16 VS2 0.9
<TS 1008 A
93 58 31 VS2
-0.74
<TS 1009 A
93 58 26 VS2 0.89
<TS 1010 A
93 60 14 VS2
-0.91
<TS 1011 A
93 60 19 VS2 0.83
<TS 1012 A
93 82 13 VS2 1.06
<TS 1013 A
93 100 14 VS2
-0.81
<TS 1014 A
93 106 18 VS2
-0.75
<TS 1015 A
93 130 20 VS2
-0.68
<TS 1016 A
93 130 15 VS2 0.64
<TS 1017 A
94 77 14 VS2
-0.66
<TS 1018 A
94 77 27 VS2 0.81
<TS 1019 A
95 124 21 VS2
-0.64
<TS 1020 A
95 124 22 VS2 1.04
<TS 1021 A
95 126 7
VS2
-0.79
<TS 1022 A
95 126 16 VS2 0.83
<TS 1023 A
95 130 8
VS2 0.16
<TS 1024 A
95 130 20 VS2 0.82
<TS 1025 A
95 132 18 VS2 0.89
<TS 1026 A
95 136 17 VS2
-0.85
<TS 1027 A
95 136 21 VS2 1.09
<TS 1028 A
97 50 29 VS2
-0.82
<TS 1029 A
97 50 17 VS2 1.04
<TS 1030 A
97 52 12 VS2
-0.84
<TS 34
No.
SG Row Column Depth in Percent Location Elevation Status 1031 A
97 52 22 VS2 0.84
<TS 1032 A
97 120 16 VS2
-0.84
<TS 1033 A
97 120 29 VS2 0.91
<TS 1034 A
98 27 18 VS2 0.56
<TS 1035 A
98 65 21 VS2
-0.65
<TS 1036 A
98 111 9
VS2
-0.03
<TS 1037 A
98 111 15 VS2 0.71
<TS 1038 A
98 113 13 VS2 0.47
<TS 1039 A
100 29 13 VS2
-0.65
<TS 1040 A
100 29 23 VS2 0.95
<TS 1041 A
100 89 16 VS2
-0.81
<TS 1042 A
100 119 22 VS2
-0.86
<TS 1043 A
100 119 24 VS2 0.05
<TS 1044 A
100 119 12 VS2 0.78
<TS 1045 A
101 108 13 VS2 0.52
<TS 1046 A
101 110 13 VS2 0.29
<TS 1047 A
101 110 14 VS2 0.67
<TS 1048 A
102 75 13 VS2
-0.72
<TS 1049 A
102 115 21 VS2
-0.76
<TS 1050 A
102 115 20 VS2
-0.29
<TS 1051 A
103 86 18 VS2 0.18
<TS 1052 A
103 86 20 VS2 0.6
<TS 1053 A
104 95 18 VS2
-0.66
<TS 1054 A
106 59 17 VS2
-0.73
<TS 1055 A
106 117 15 VS2 0.16
<TS 1056 A
107 44 13 VS2 0.89
<TS 1057 A
107 124 17 VS2
-0.08
<TS 1058 A
107 130 15 VS2
-0.46
<TS 1059 A
107 132 13 VS2
-0.81
<TS 1060 A
107 132 18 VS2 0
<TS 1061 A
108 63 14 VS2
-0.03
<TS 1062 A
108 63 18 VS2 0.77
<TS 1063 A
108 123 18 VS2
-0.82
<TS 1064 A
109 98 29 VS2
-0.85
<TS 1065 A
110 39 18 VS2 0.77
<TS 1066 A
111 62 22 VS2
-0.94
<TS 1067 A
112 103 14 VS2
-0.6
<TS 1068 A
114 37 37 VS2
-0.94
<TS 1069 A
114 37 10 VS2 0.97
<TS 1070 A
115 90 15 VS2
-0.99
<TS 1071 A
118 97 16 VS2
-0.84
<TS 1072 A
118 99 13 VS2 0.81
<TS 1073 A
122 117 17 VS2
-0.93
<TS 1074 A
122 117 6
VS2 0.38
<TS 1075 A
123 110 14 VS2 0.91
<TS 1076 A
124 107 13 VS2
-0.44
<TS 1077 A
126 103 12 VS2 0.87
<TS 35
No.
SG Row Column Depth in Percent Location Elevation Status 1078 A
127 110 29 VS2
-0.6
<TS 1079 A
127 110 16 VS2 0.96
<TS 1080 A
128 71 17 VS2 0.06
<TS 1081 A
128 101 15 VS2
-0.51
<TS 1082 A
128 103 11 VS2 1.01
<TS 1083 A
132 67 20 VS2
-0.98
<TS 1084 A
132 67 16 VS2 0.95
<TS 1085 A
132 93 27 VS2 0.74
<TS 1086 A
133 94 9
VS2
-0.8
<TS 1087 A
133 94 16 VS2 0.93
<TS 1088 A
134 95 22 VS2 0.06
<TS 1089 A
137 76 16 VS2 0
<TS 1090 A
50 157 34 VS3
-0.84
<15 1091 A
50 157 20 VS3 0.98
<TS 1092 A
51 20 28 VS3
-0.68
<TS 1093 A
52 149 17 VS3 1.05
<TS 1094 A
64 37 15 VS3 0.19
<TS 1095 A
65 116 11 VS3 0.83 -
TS 1096 A
65 152 21 VS3 1.14
<TS 1097 A
67 136 21 VS3 0.92
<TS 1098 A
68 17 13 VS3
-0.6
<TS 1099 A
68 139 26 VS3
-0.67
<TS 1100 A
69 136 14 VS3
-0.52
<TS 1101 A
69 152 24 VS3
-0.81
<TS 1102 A
69 152 23 VS3 1.09
<TS 1103 A
70 153 22 VS3
-1.05
<TS 1104 A
71 134 16 VS3
-0.67
<TS 1105 A
75 44 33 VS3
-0.69
<TS 1106 A
75 44 19 VS3 1.01
<TS 1107 A
75 50 24 VS3
-0.91
<TS 1108 A
75 50 18 VS3 0.88
<TS 1109 A
77 44 14 VS3 0.97
<TS 1110 A
79 72 17 VS3 0.08
<TS 1111 A
80 27 14 VS3 0.94
<TS 1112 A
81 118 10 VS3
-0.97
<TS 1113 A
81 130 19 VS3
-0.61
<TS 1114 A
82 61 16 VS3
-0.86
<TS 1115 A
82 71 12 VS3 1.04
<TS 1116 A
82 135 16 VS3
-0.88
<TS 1117 A
82 141 19 VS3
-0.82
<TS 1118 A
84 39 16 VS3
-0.7
<TS 1119 A
84 147 13 VS3 0.03
<TS 1120 A
84 147 20 VS3 0.84
<TS 1121 A
18 25 16 VS4
-0.71
<TS 1122 A
18 49 12 VS4
-1.06
<TS 1123 A
20 37 9
VS4
-0.95
<TS 1124 A
23 40 15 VS4 0.74
<TS 36
No.
SG Row Column Depth in Percent Location Elevation Status 1125 A
23 40 15 VS4 1.02
<TS 1126 A
23 40 12 VS4
-0.92 -
TS 1127 A
23 50 10 VS4
-1.03
<TS 1128 A
24 41 14 VS4
-0.86
<TS 1129 A
24 41 9
VS4
-0.98
<TS 1130 A
26 121 17 VS4
-0.8
<TS 1131 A
26 121 17 VS4
-0.23
<TS 1132 A
26 125 11 VS4 0.11
<TS 1133 A
28 19 23 VS4
-0.82
<TS 1134 A
28 31 21 VS4
-0.62
<TS 1135 A
28 43 13 VS4
-0.79
<TS 1136 A
28 53 20 VS4
-0.92
<TS 1137 A
28 63 16 VS4
-0.96
<TS 1138 A
28 63 8
VS4 0.87
<TS 1139 A
28 103 9
VS4 0.8
<TS 1140 A
31 16 26 VS4 0.86
<TS 1141 A
31 126 19 VS4
-0.52
<TS 1142 A
31 128 18 VS4
-0.83
<TS 1143 A
31 128 22 VS4 0.92
<TS 1144 A
31 132 17 VS4 0.88
<TS 1145 A
32 145 21 VS4
-1.04
<TS 1146 A
34 15 17 VS4
-0.87
<TS 1147 A
34 109 9
VS4
-0.74
<TS 1148 A
36 109 11 VS4 0
<TS 1149 A
37 128 12 VS4
-0.89
<TS 1150 A
37 128 19 VS4 0.95
<TS 1151 A
40 147 24 VS4
-0.99
<TS 1152 A
40 147 22 VS4
-0.32
<TS 1153 A
41 52 27 VS4
-0.9
<TS 1154 A
41 52 11 VS4 0.81
<TS 1155 A
42 5
12 VS4
-0.68
<TS 1156 A
42 41 31 VS4
-0.91
<TS 1157 A
42 41 25 VS4 0.94
<TS 1158 A
43 46 14 VS4
-1.15
<TS 1159 A
43 46 27 VS4
-0.84
<TS 1160 A
43 46 13 VS4 0
<TS 1161 A
43 46 11 VS4 1.09
<TS 1162 A
43 126 28 VS4 0.91
<TS 1163 A
44 19 14 VS4 0.59
<TS 1164 A
44 21 26 VS4
-0.77
<TS 1165 A
44 21 20 VS4
-0.15
<TS 1166 A
44 21 26 VS4 0.65
<TS 1167 A
44 41 21 VS4
-0.18
<TS 1168 A
44 49 25 VS4
-0.59
<TS 1169 A
44 49 25 VS4 0.09
<TS 1170 A
44 65 22 VS4
-0.62
<TS 1171 A
44 65 19 VS4
-0.27
<TS 37
No.
SG Row Column Depth in Percent Location Elevation Status 1172 A
44 123 18 VS4
-0.68
<TS 1173 A
44 123 18 VS4
-0.1
<TS 1174 A
44 123 11 VS4 0.71
<TS 1175 A
45 124 20 VS4 0.83
<TS 1176 A
46 53 29 VS4
-0.87
<TS 1177 A
46 53 23 VS4 0.96
<TS 1178 A
46 55 17 VS4 0.84
<TS 1179 A
46 65 19 VS4 0.98
<TS 1180 A
46 69 15 VS4
-0.41
<TS 1181 A
46 69 20 VS4
-0.9
<TS 1182 A
46 125 14 VS4
-0.12
<TS 1183 A
46 125 13 VS4 0.23
<TS 1184 A
46 125 14 VS4 0.92
<TS 1185 A
47 50 16 VS4 0.87
<TS 1186 A
47 110 17 VS4
-0.73
<TS 1187 A
47 122 24 VS4 0
<TS 1188 A
47 122 29 VS4 0.9
<TS 1189 A
47 124 14 VS4
-0.61
<TS 1190 A
47 124 19 VS4 0.26
<TS 1191 A
47 124 20 VS4 0.91
<TS 1192 A
47 126 24 VS4
-0.74
<TS 1193 A
47 126 23 VS4 0
<TS 1194 A
48 19 37 VS4
-0.84
<TS 1195 A
48 19 29 VS4 0.9
<TS 1196 A
48 21 27 VS4
-0.61
<TS 1197 A
48 41 37 VS4
-0.86
<TS 1198 A
48 41 18 VS4 0.86
<TS 1199 A
48 43 35 VS4
-0.74
<TS 1200 A
48 43 10 VS4 0.24
<TS 1201 A
48 43 21 VS4 0.74
<TS 1202 A
48 47 30 VS4
-0.96
<TS 1203 A
48 47 37 VS4 0.87
<TS 1204 A
48 69 13 VS4
-0.81
<TS 1205 A
48 69 34 VS4 0.81
<TS 1206 A
48 97 29 VS4 0.75
<TS 1207 A
49 10 19 VS4 0.93
<TS 1208 A
49 20 28 VS4
-0.75
<TS 1209 A
49 20 25 VS4 1.07
<TS 1210 A
49 24 16 VS4
-0.75
<TS 1211 A
49 66 17 VS4 0
<TS 1212 A
49 66 16 VS4 0.87
<TS 1213 A
49 70 16 VS4 0.66
<TS 1214 A
49 74 19 VS4
-0.96
<TS 1215 A
49 112 13 VS4
-0.57
<TS 1216 A
49 112 19 VS4
-0.22
<TS 1217 A
50 17 14 VS4
-0.83
<TS 1218 A
50 19 14 VS4 0.75
<TS 38
No.
SG Row Column Depth in Percent Location Elevation Status 1219 A
50 91 14 VS4 0.88
<TS 1220 A
51 16 19 VS4
-0.64
<TS 1221 A
51 18 9
VS4 0.93
<TS 1222 A
52 149 12 VS4
-0.93
<TS 1223 A
61 120 17 VS4
-0.98
<TS 1224 A
64 11 28 VS4
-0.87
<TS 1225 A
64 11 8
VS4 0.55
<TS 1226 A
64 13 19 VS4
-0.91
<TS 1227 A
68 21 23 VS4
-0.87
<TS 1228 A
68 21 18 VS4 0.96
<TS 1229 A
69 22 26 VS4
-1.05
<TS 1230 A
69 22 18 VS4
-0.03
<TS 1231 A
69 22 27 VS4 0.88
<TS 1232 A
71 78 7
VS4
-1.08
<TS 1233 A
71 78 6
VS4 0.89
<TS 1234 A
74 15 20 VS4 0.95
<TS 1235 A
76 51 16 VS4 0.93
<TS 1236 A
76 131 13 VS4 0.98
<TS 1237 A
77 16 31 VS4
-0.81
<TS 1238 A
77 44 12 VS4
-0.12
<TS 1239 A
79 18 14 VS4
-0.79
<TS 1240 A
79 150 16 VS4 0.96
<TS 1241 A
80 149 16 VS4
-0.74
<TS 1242 A
81 84 30 VS4 1
<TS 1243 A
82 19 8
VS4
-0.88
<TS 1244 A
82 19 15 VS4 0.8
<TS 1245 A
83 148 16 VS4
-1.09
<TS 1246 A
83 148 13 VS4
-0.88
<TS 1247 A
83 148 9
VS4
-0.25
<TS 1248 A
83 148 7
VS4 0.24
<TS 1249 A
84 19 25 VS4
-0.95
<TS 1250 A
84 19 20 VS4 0.96
<TS 1251 A
85 20 26 VS4
-0.8
<TS 1252 A
85 20 21 VS4 0.8
<TS 1253 A
87 20 16 VS4
-0.14
<TS 1254 A
87 20 22 VS4 0.69
<TS 1255 A
87 22 18 VS4
-0.82
<TS 1256 A
87 146 17 VS4
-0.99
<TS 1257 A
87 146 21 VS4 0.39
<TS 1258 A
88 21 23 VS4
-0.84
<TS 1259 A
88 25 10 VS4
-0.61
<TS 1260 A
88 53 19 VS4 0.92
<TS 1261 A
88 145 16 VS4 0.78
<TS 1262 A
90 23 13 VS4
-0.84
<TS 1263 A
90 25 6
VS4
-0.88
<TS 1264 A
90 25 14 VS4 1.02
<TS 1265 A
91 22 29 VS4 0.66
<TS 39
No.
SG Row Column Depth in Percent Location Elevation Status 1266 A
91 144 15 VS4 0.63
<TS 1267 A
92 59 14 VS4
-0.84
<TS 1268 A
92 59 8
VS4 0.06
<TS 1269 A
92 59 16 VS4 0.77
<TS 1270 A
92 117 13 VS4
-0.6
<TS 1271 A
92 117 9
VS4 0.82
<TS 1272 A
93 26 10 VS4
-0.8
<TS 1273 A
93 26 14 VS4 1.02
<TS 1274 A
93 58 22 VS4 0.77
<TS 1275 A
93 76 17 VS4 0.03
<TS 1276 A
93 76 18 VS4 0.88
<TS 1277 A
93 104 32 VS4
-0.56
<TS 1278 A
93 130 21 VS4
-0.9
<TS 1279 A
93 130 36 VS4 0.91
<TS 1280 A
94 25 17 VS4
-0.83
<TS 1281 A
94 25 9
VS4
-0.08
<TS 1282 A
94 31 22 VS4
-0.78
<TS 1283 A
95 24 27 VS4
-0.81
<TS 1284 A
95 24 18 VS4 0.33
<TS 1285 A
95 30 36 VS4
-0.75
<TS 1286 A
95 30 30 VS4 0.88
<TS 1287 A
95 132 12 VS4 0.95
<TS 1288 A
96 25 36 VS4 0.91
<TS 1289 A
97 26 17 VS4
-0.75
<TS 1290 A
97 26 21 VS4 0.71
<TS 1291 A
97 48 17 VS4
-0.82
<TS 1292 A
97 48 18 VS4 1.05
<TS 1293 A
97 50 21 VS4
-0.71
<TS 1294 A
97 50 21 VS4 0.93
<TS 1295 A
97 52 28 VS4
-0.72
<TS 1296 A
97 106 26 VS4
-0.83
<TS 1297 A
97 106 19 VS4 0.9
<TS 1298 A
97 114 16 VS4
-0.81
<TS 1299 A
97 116 19 VS4
-0.88
<TS 1300 A
97 118 23 VS4 0.64
<TS 1301 A
97 120 9
VS4
-1.01
<TS 1302 A
97 120 14 VS4 0.56
<TS 1303 A
97 126 10 VS4 0.19
<TS 1304 A
97 132 18 VS4 0.83
<TS 1305 A
97 134 10 VS4
-0.79
<TS 1306 A
97 134 18 VS4 1
<TS 1307 A
99 26 26 VS4
-0.58
<TS 1308 A
99 136 14 VS4
-0.9
<TS 1309 A
99 136 9
VS4 0.38
<TS 1310 A
99 138 16 VS4 0.22
<TS 1311 A
99 138 15 VS4 0.9
<TS 1312 A
99 140 23 VS4
-0.66
<TS 40
No.
SG Row Column Depth in Percent Location Elevation Status 1313 A
100 27 23 VS4
-0.8
<TS 1314 A
100 27 14 VS4
-0.22
<TS 1315 A
100 27 18 VS4 0.93
<TS 1316 A
100 29 18 VS4 0.88
<TS 1317 A
100 107 16 VS4
-0.89
<TS 1318 A
100 107 11 VS4 1.08
<TS 1319 A
100 119 13 VS4
-0.91
<TS 1320 A
100 137 12 VS4
-0.77
<TS 1321 A
100 139 18 VS4
-0.79
<TS 1322 A
101 30 17 VS4
-0.83
<TS 1323 A
101 138 19 VS4 0.76
<TS 1324 A
102 29 23 VS4
-0.77
<TS 1325 A
102 29 10 VS4
-0.05
<TS 1326 A
102 121 24 VS4
-0.73
<TS 1327 A
103 30 9
VS4
-0.08
<TS 1328 A
103 30 17 VS4 0.77
<TS 1329 A
103 32 20 VS4
-0.93
<TS 1330 A
103 32 8
VS4 0.61
<TS 1331 A
104 31 17 VS4
-0.82
<TS 1332 A
104 31 20 VS4 1.01
<TS 1333 A
105 30 26 VS4
-0.52
<TS 1334 A
105 136 15 VS4
-0.8
<TS 1335 A
105 136 14 VS4 1.04
<TS 1336 A
106 33 20 VS4
-0.83
<TS 1337 A
106 59 25 VS4
-1.14
<TS 1338 A
106 59 34 VS4 0.88
<TS 1339 A
106 63 14 VS4
-1.15
<TS 1340 A
106 63 17 VS4 0.21
<TS 1341 A
106 69 13 VS4
-1.15
<TS 1342 A
106 119 12 VS4 0.89
<TS 1343 A
106 135 25 VS4
-0.9
<TS 1344 A
107 32 34 VS4
-0.87
<TS 1345 A
107 32 16 VS4
-0.47
<TS 1346 A
107 44 8
VS4 0.94
<TS 1347 A
107 134 23 VS4
-0.85
<TS 1348 A
107 134 14 VS4 0.93
<TS 1349 A
108 33 30 VS4
-0.77
<TS 1350 A
108 33 27 VS4 0.92
<TS 1351 A
108 41 16 VS4 1.12
<TS 1352 A
109 34 12 VS4
-0.67
<TS 1353 A
109 34 31 VS4 0.65
<TS 1354 A
111 110 18 VS4
-1.04
<TS 1355 A
111 128 10 VS4 1.03
<TS 1356 A
112 41 19 VS4
-1
<TS 1357 A
112 59 25 VS4
-0.41
<TS 1358 A
112 59 5
VS4
-0.11
<TS 1359 A
112 59 14 VS4 0.52
<TS 41
No.
SG Row Column Depth in Percent Location Elevation Status 1360 A
112 89 15 VS4
-0.82
<TS 1361 A
113 36 19 VS4
-0.7
<TS 1362 A
113 42 13 VS4
-0.67
<TS 1363 A
113 42 13 VS4 1.09
<TS 1364 A
113 130 22 VS4
-0.7
<TS 1365 A
113 130 23 VS4
-0.36
<TS 1366 A
114 129 19 VS4
-0.85
<TS 1367 A
115 38 13 VS4 0.53
<TS 1368 A
115 46 17 VS4
-0.68
<TS 1369 A
115 50 15 VS4
-0.79
<TS 1370 A
115 90 38 VS4
-0.75
<TS 1371 A
116 71 11 VS4 1.15
<TS 1372 A
116 89 36 VS4
-1.2
<TS 1373 A
116 89 40 VS4
-0.97
>TS 1374 A
116 105 23 VS4
-1.03
<TS 1375 A
117 40 24 VS4
-0.94
<TS 1376 A
117 50 11 VS4
-0.97
<TS 1377 A
118 41 19 VS4
-0.71
<TS 1378 A
118 63 20 VS4
-0.86
<TS 1379 A
118 63 14 VS4 0.89
<TS 1380 A
118 101 15 VS4 0.95
<TS 1381 A
119 60 15 VS4
-0.9
<TS 1382 A
119 124 9
VS4
-0.68
<TS 1383 A
119 124 7
VS4 0.62
<TS 1384 A
120 81 11 VS4 1.14
<TS 1385 A
121 44 19 VS4 0.16
<TS 1386 A
121 82 15 VS4
-0.78
<TS 1387 A
121 104 12 VS4 0.79
<TS 1388 A
121 118 29 VS4
-0.79
<TS 1389 A
121 118 12 VS4
-0.19
<TS 1390 A
121 118 16 VS4 0.8
<TS 1391 A
122 81 22 VS4 1.11
<TS 1392 A
124 119 13 VS4
-0.86
<TS 1393 A
125 48 24 VS4
-0.71
<TS 1394 A
126 69 17 VS4
-0.86
<TS 1395 A
126 69 33 VS4 0.82
<TS 1396 A
126 103 31 VS4
-1.01
<TS 1397 A
127 106 18 VS4
-0.55
<TS 1398 A
127 110 14 VS4
-0.84
<TS 1399 A
127 110 13 VS4
-0.16
<TS 1400 A
129 62 17 VS4
-0.94
<TS 1401 A
129 92 13 VS4
-0.84
<TS 1402 A
129 92 7
VS4 0.9
<TS 1403 A
129 94 16 VS4 0.4
<TS 1404 A
130 71 21 VS4
-1.03
<TS 1405 A
130 95 23 VS4
-1.09
<TS 1406 A
133 60 12 VS4 0.61
<TS 42
No.
SG Row Column Depth in Percent Location Elevation Status 1407 A
133 66 16 VS4
-0.95
<TS 1408 A
133 74 21 VS4 0.05
<TS 1409 A
133 74 24 VS4 0.76
<TS 1410 A
133 94 13 VS4
-0.74
<TS 1411 A
134 95 29 VS4
-0.89
<TS 1412 A
134 95 9
VS4 1.15
<TS 1413 A
135 74 19 VS4
-0.55
<TS 1414 A
135 86 19 VS4 0.93
<TS 1415 A
137 76 30 VS4
-0.84
<TS 1416 A
137 76 27 VS4
-0.11
<TS 1417 A
137 78 20 VS4
-0.71
<TS 1418 A
137 78 22 VS4 0.95
<TS 1419 A
137 88 15 VS4
-0.81
<TS 1420 A
138 81 19 VS4
-0.98
<TS 1421 A
138 81 19 VS4 0.94
<TS 1422 A
52 97 13 VS5
-0.72
<TS 1423 A
52 127 12 VS5
-0.94
<TS 1424 A
64 11 16 VS5 0.93
<TS 1425 A
64 37 17 VS5 0.92
<TS 1426 A
67 120 14 VS5 1.03
<TS 1427 A
68 21 13 VS5
-0.09
<TS 1428 A
68 21 16 VS5 0.96
<TS 1429 A
68 139 13 VS5
-0.8
<TS 1430 A
68 139 32 VS5 0.88
<TS 1431 A
69 22 23 VS5 0.88
<TS 1432 A
69 106 11 VS5 1.06
<TS 1433 A
69 136 15 VS5 0.86
<TS 1434 A
75 16 26 VS5
-0.75
<TS 1435 A
75 128 5
VS5
-0.98
<TS 1436 A
77 44 21 VS5 0.87
<TS 1437 A
79 144 14 VS5
-0.69
<TS 1438 A
79 144 23 VS5 0.92
<TS 1439 A
81 46 22 VS5 0.96
<TS 1440 A
84 19 17 VS5 0.85
<TS 1441 A
90 115 17 VS6
-0.89
<TS 1442 A
90 115 13 VS6
-0.28
<TS 1443 A
90 115 5
VS6 0.55
<TS 1444 A
91 70 13 VS6 0.83
<TS 1445 A
92 23 26 VS6 1
<TS 1446 A
92 59 14 VS6 0.89
<TS 1447 A
92 85 15 VS6 0.87
<TS 1448 A
93 58 29 VS6 1.04
<TS 1449 A
93 60 16 VS6
-0.99
<TS 1450 A
93 60 12 VS6 0.93
<TS 1451 A
93 104 13 VS6
-0.65
<TS 1452 A
93 104 26 VS6 0.99
<TS 1453 A
94 67 20 V56
-0.93
<TS 43
No.
SG Row Column Depth in Percent Location Elevation Status 1454 A
94 67 13 VS6 0.56
<TS 1455 A
96 37 15 VS6
-0.73
<TS 1456 A
96 41 13 VS6
-0.34
<TS 1457 A
96 41 18 VS6 0.88
<TS 1458 A
96 105 17 VS6
-0.71
<TS 1459 A
96 117 8
VS6 0.51
<TS 1460 A
96 121 18 VS6 0.89
<TS 1461 A
97 46 15 VS6
-0.67
<TS 1462 A
97 46 15 VS6
-0.22
<TS 1463 A
97 48 15 VS6
-0.68
<TS 1464 A
97 48 18 VS6 0.89
<TS 1465 A
97 50 21 VS6 0.84
<TS 1466 A
97 52 25 VS6 0.71
<TS 1467 A
97 90 23 VS6
-0.45
<TS 1468 A
98 27 12 VS6
-0.9
<TS 1469 A
98 27 17 VS6 0.96
<TS 1470 A
98 119 15 VS6 0.66
<TS 1471 A
99 84 18 VS6
-0.67
<TS 1472 A
100 67 31 VS6
-0.92
<TS 1473 A
100 119 15 VS6 0.85
<TS 1474 A
104 109 15 VS6
-0.64
<TS 1475 A
106 31 34 VS6
-0.75
<TS 1476 A
106 31 30 VS6 0.97
<TS 1477 A
106 59 23 VS6
-0.91
<TS 1478 A
106 67 19 VS6 0.47
<TS 1479 A
106 69 12 VS6 0.95
<TS 1480 A
112 59 31 VS6 0.97
<TS 1481 A
113 68 16 VS6 1.07
<TS 1482 A
113 76 14 VS6 0.94
<TS 1483 A
114 37 12 VS6 0.85
<TS 1484 A
116 39 18 VS6
-0.45
<TS 1485 A
116 63 14 VS6
-0.87
<TS 1486 A
116 81 14 VS6
-0.6
<TS 1487 A
116 89 18 VS6
-0.81
<TS 1488 A
116 89 41 VS6 0.92
>TS 1489 A
118 53 13 VS6
-0.94
<TS 1490 A
121 104 12 VS6
-0.74
<TS 1491 A
121 104 11 VS6 0.2
<TS 1492 A
126 111 13 VS6
-0.79
<TS 1493 A
126 115 16 VS6
-0.76
<TS 1494 A
127 72 20 VS6
-0.36
<TS 1495 A
130 73 13 VS6 0.92
<TS 1496 A
133 92 21 VS6 0.89
<TS 1497 A
133 94 15 VS6
-1.03
<TS 1498 A
134 73 17 VS6 1.02
<TS 1499 A
134 91 19 VS6
-0.45
<TS 1500 A
134 95 29 VS6 1.01
<TS 44
No.
SG Row Column Depth in Percent Location Elevation Status 1501 A
135 78 35 VS6 0.82
<TS 1502 A
135 94 16 VS6
-0.66
<TS 1503 A
135 94 22 VS6 0.93
<TS 1504 A
135 96 38 VS6 1.02
<TS 1505 A
135 100 20 VS6
-0.69
<TS 1506 A
137 80 18 VS6
-1.03
<TS 1507 A
137 88 17 VS6
-0.88
<TS 1508 A
137 88 20 VS6
-0.28
<TS 1509 A
137 92 32 VS6
-0.85
<TS 1510 A
137 92 24 VS6
-0.11
<15 1511 A
137 92 16 VS6 0.96
<TS 1512 A
138 81 34 VS6
-0.99
<TS 1513 A
138 81 27 VS6 0.93
<TS 1514 A
118 125 17 VS7
-1.05
<TS 1515 A
126 111 15 VS7 0.88
<TS 1516 A
127 80 16 VS7 0.63
<TS 1517 A
130 73 18 VS7 0.69
<TS 1518 A
132 95 31 VS7 0.92
<TS 1519 A
134 69 20 VS7 0.14
<TS 1520 A
134 69 27 VS7 0.62
<TS 1521 A
134 91 28 VS7
-0.9
<TS 1522 A
134 95 30 VS7 0.87
<TS 1523 A
135 72 17 VS7 0.69
<TS 1524 A
135 94 25 VS7
-0.56
<TS 1525 A
135 96 14 VS7
-0.86
<TS 1526 A
135 96 18 VS7 0.95
<TS 1527 A
135 100 32 VS7
-0.5
<TS 1528 A
136 69 16 VS7
-1
<TS 1529 A
136 69 7
VS7 0.92
<TS 1530 A
137 78 15 VS7 0.77
<TS 1531 A
137 80 16 VS7 0.11
<TS 1532 A
137 80 24 VS7 0.86
<TS 1533 A
138 81 18 VS7 0
<TS 1534 A
138 81 18 VS7 0.74
<TS 1535 A
138 85 23 VS7 0.88
<TS 45
Table 4C Steam Generator E-50B Indications (all indications due to tube wear for tubes that remain in service)
No.
SG Row Column Depth in Percent Location Elevation Status 1
B 1
150 9
01 C
-0.99
<TS 2
B 1
150 9
01 C
-0.25
<TS 3
B 2
165 14 01 C 0.75
<TS 4
B 35 4
16 01C
-0.94
<TS 5
B 46 7
10 01 C 0.81
<TS 6
B 46 7
22 01 C
-0.13
<TS 7
B 46 159 17 01 C 0.21
<TS 8
B 49 10 18 01 C 0.93
<TS 9
B 49 158 18 01 C 0.21
<TS 10 B
53 8
18 01 C 0.76
<TS 11 B
103 30 15 01 C 0.08
<TS 12 B
111 36 16 01 C 0.96
<TS 13 B
115 38 36 01 C 0.08
<TS 14 B
120 43 10 01 C 0.8
<TS 15 B
120 43 19 01 C
-0.8
<TS 16 B
128 55 19 01 C 0
<TS 17 B
131 58 30 01 C 0.99
<TS 18 B
44 159 15 01H
-1.01
<TS 19 B
50 157 20 01H
-0.99
<TS 20 B
51 58 14 01H 0.97
<TS 21 B
80 149 18 01H
-0.9
<TS 22 B
121 44 21 01H 0.86
<TS 23 B
127 54 17 01H
-0.88
<TS 24 B
129 56 21 01H 0.82
<10 25 B
1 28 12 02C 0.83
<TS 26 B
1 124 8
02C 0.77
<TS 27 B
1 158 16 02C 0.74
<TS 28 B
1 164 17 02C
-0.92
<TS 29 B
2 143 12 02C 0.83
<TS 30 B
6 165 18 02C
-1.04
<TS 31 B
8 165 16 02C
-0.99
<TS 32 B
11 164 23 02C
-0.92
<TS 33 B
18 141 8
02C
-0.93
<TS 34 B
18 141 11 02C 0.8
<TS 35 B
19 164 24 02C 0.84
<TS 36 B
22 163 21 02C 1
<TS 37 B
30 53 11 02C 0.79
<TS 38 B
32 5
18 02C 0.84
<TS 39 B
33 158 19 02C 0.84
<TS 40 B
36 157 17 02C
-0.88
<TS 41 B
38 45 14 02C 0.11
<TS 42 B
38 107 19 02C 0.81
<TS 43 B
40 5
16 02C
-0.89
<TS 46
No.
SG Row Column Depth in Percent Location Elevation Status 44 B
43 6
24 02C
-0.18
<TS 45 B
43 6
14 02C
-0.97
<TS 46 B
44 41 17 02C 0
<TS 47 B
44 127 22 02C 0.94
<TS 48 B
45 6
20 02C
-0.96
<TS 49 B
45 6
19 02C
-0.26
<TS 50 B
45 126 18 02C 0.86
<TS 51 B
48 107 16 02C 0.81
<TS 52 B
53 132 15 02C 0.85
<TS 53 B
56 85 12 02C
-0.8
<TS 54 B
63 86 15 02C
-0.81
<TS 55 B
65 122 13 02C 0.89
<TS 56 B
66 125 16 02C 0.79
<TS 57 B
84 55 18 02C 0.78
<TS 58 B
84 81 15 02C 0.8
<TS 59 B
84 93 16 02C
-0.99
<TS 60 B
91 32 16 02C
-1.04
<TS 61 B
91 54 13 02C 0.94
<TS 62 B
94 57 15 02C 0.94
<TS 63 B
99 32 14 02C 0.84
<TS 64 B
101 30 8
02C 0.71
<TS 65 B
102 31 16 02C
-0.83
<TS 66 B
104 31 18 02C
-0.1
<TS 67 B
105 30 21 02C 0.77
<TS 68 B
105 34 19 02C 0.03
<TS 69 B
105 134 17 02C 0.91
<TS 70 B
106 31 16 02C 0.79
<TS 71 B
106 35 16 02C
-0.1
<TS 72 B
106 85 13 02C 0.91
<TS 73 B
108 131 17 02C 0.83
<TS 74 B
108 133 21 02C 0.1
<TS 75 B
109 36 17 02C
-0.96
<TS 76 B
109 130 28 02C 0.5
<TS 77 B
110 41 20 02C
-0.05
<TS 78 B
110 131 14 02C 0.81
<TS 79 B
110 131 15 02C
-0.92
<TS 80 B
111 36 19 02C 0.06
<TS 81 B
111 36 14 02C 0.94
<TS 82 B
113 36 15 02C 0.91
<TS 83 B
117 40 18 02C 0.83
<TS 84 B
117 40 24 02C
-1.09
<TS 85 B
119 46 21 02C 0.86
<TS 86 B
120 45 15 02C 0.84
<TS 87 B
123 52 20 02C 0.79
<TS 88 B
124 49 18 02C
-0.84
<TS 89 B
125 112 23 02C 0.96
<TS 90 B
126 115 20 02C 0.75
<TS 47
No.
SG Row Column Depth in Percent Location Elevation Status 91 B
126 115 13 02C 0.1
<TS 92 B
127 112 21 02C 0.91
<TS 93 B
127 114 14 02C 0.94
<TS 94 B
128 113 26 02C
-0.81
<TS 95 B
129 108 16 02C 0.98
<TS 96 B
129 110 21 02C 0.84
<TS 97 B
130 55 17 02C 0.81
<TS 98 B
132 107 27 02C
-0.86
<TS 99 B
5 138 15 02H
-0.84
<TS 100 B
10 165 19 02H 0.92
<15 101 B
11 2
18 02H 0.83
<TS 102 B
13 4
18 02H
-0.78
<15 103 B
13 140 15 02H 0.77
<TS 104 B
38 161 21 02H 0.96
<TS 105 B
39 160 16 02H 0.93
<TS 106 B
59 66 14 02H
-0.92
<TS 107 B
60 41 24 02H
-0.1
<TS 108 B
61 68 17 02H
-0.9
<15 109 B
68 109 16 02H 0.85
<15 110 B
72 113 13 02H
-0.83
<TS 111 B
72 113 11 02H 0.8
<TS 112 B
78 109 15 02H
-0.9
<15 113 B
81 112 16 02H 0.98
<TS 114 B
113 84 14 02H
-0.77
<15 115 B
119 44 22 02H 0.9
<TS 116 B
125 116 22 02H 1
<TS 117 B
132 61 21 02H
-0.92
<15 118 B
134 65 20 02H 0.96
<TS 119 B
138 77 21 02H 0.8
<15 120 B
1 160 13 03C
-0.17
<TS 121 B
3 42 20 03C 0.78
<TS 122 B
8 3
13 03C
-0.26
<TS 123 B
18 5
16 03C
-0.21
<TS 124 B
18 141 13 03C
-0.83
<TS 125 B
21 4
15 03C 0.89
<TS 126 B
30 111 12 03C
-0.73
<15 127 B
34 109 13 03C 0.82
<TS 128 B
34 133 16 03C 0.77
<15 129 B
36 5
13 03C 0.08
<TS 130 B
36 5
20 03C 0.66
<TS 131 B
36 113 17 03C 0.8
<TS 132 B
37 10 24 03C
-1
<TS 133 B
37 10 15 03C
-0.21
<TS 134 B
39 132 13 03C 0.97
<15 135 B
40 117 18 03C 0.74
<TS 136 B
41 134 11 03C 0.94
<TS 137 B
43 8
13 03C 0.58
<TS 48
No.
SG Row Column Depth in Percent Location Elevation Status 138 B
44 45 13 03C 0.76
<TS 139 B
44 131 18 03C 1.1
<TS 140 B
46 59 16 03C 0.89
<TS 141 B
48 129 12 03C
-0.16
<TS 142 B
51 134 12 03C
-0.73
<TS 143 B
53 80 17 03C 0.96
<TS 144 B
53 128 18 03C 0.73
<TS 145 B
53 134 14 03C 0.97
<TS 146 B
55 114 17 03C 0.97
<TS 147 B
55 114 12 03C 0.21
<TS 148 B
56 85 19 03C 0.98
<TS 149 B
56 129 21 03C 0.8
<TS 150 B
56 129 13 03C
-0.92
<TS 151 B
57 80 14 03C 0.95
<TS 152 B
57 90 16 03C
-0.99
<TS 153 B
57 90 19 03C 0.71
<TS 154 B
59 48 18 03C 0.79
<TS 155 B
59 122 17 03C
-0.08
<TS 156 B
60 133 16 03C
-0.85
<TS 157 B
63 138 17 03C 0.88
<TS 158 B
67 58 13 03C 0.91
<TS 159 B
67 58 6
03C 0.16
<TS 160 B
67 62 16 03C 0.84
<TS 161 B
67 134 19 03C 0.89
<TS 162 B
67 138 22 03C 0.21
<TS 163 B
67 138 26 03C 0.95
<TS 164 B
69 110 14 03C 0.53
<TS 165 B
69 120 13 03C 0.05
<TS 166 B
69 120 22 03C 0.8
<TS 167 B
69 124 17 03C
-0.98
<TS 168 B
69 128 19 03C 0.85
<TS 169 B
70 153 20 03C 0.1
<TS 170 B
71 52 17 03C 0.88
<TS 171 B
72 49 31 03C 1.04
<TS 172 B
78 57 16 03C 0.78
<TS 173 B
79 128 13 03C 0.82
<TS 174 B
87 146 30 03C 0.85
<TS 175 B
88 95 19 03C 0.76
<TS 176 B
91 64 20 03C
-0.97
<TS 177 B
94 93 13 03C
-1.07
<TS 178 B
95 140 15 03C
-0.99
<TS 179 B
96 139 10 03C 0.75
<TS 180 B
96 139 18 03C
-0.8
<TS 181 B
97 28 18 03C 0.76
<TS 182 B
100 29 20 03C 0.79
<TS 183 B
101 30 16 03C
-1
<TS 184 B
101 30 10 030 0.71
<TS 49
No.
SG Row Column Depth in Percent Location Elevation Status 185 B
102 33 23 03C
-0.97
<TS 186 B
102 35 22 03C 0.86
<TS 187 B
103 62 16 03C 0.94
<TS 188 B
105 34 14 03C
-0.85
<TS 189 B
105 38 21 03C 0.87
<TS 190 B
105 130 24 03C 0.47
<TS 191 B
106 31 21 03C 0.79
<TS 192 B
106 33 13 03C 0
<TS 193 B
106 39 27 03C 0.91
<TS 194 B
107 132 27 03C 0.84
<TS 195 B
108 131 15 03C 0.1
<TS 196 B
110 131 24 03C 0.88
<TS 197 B
110 131 13 03C
-0.92
<TS 198 B
112 127 24 03C 0.11
<TS 199 B
114 127 20 03C 0.88
<TS 200 B
116 117 19 03C
-0.23
<TS 201 B
116 117 16 03C
-1.03
<TS 202 B
116 125 34 03C 0.98
<TS 203 B
117 40 23 03C
-0.97
<TS 204 B
119 42 17 03C 1.04
<TS 205 B
119 112 13 03C
-0.94
<TS 206 B
119 112 19 03C 0.98
<TS 207 B
120 47 12 03C
-0.84
<TS 208 B
120 47 24 03C 0.91
<TS 209 B
120 115 22 03C 0.95
<TS 210 B
125 114 11 03C 0.91
<TS 211 B
136 95 21 03C 0.87
<TS 212 B
136 97 20 03C 0.95
<TS 213 B
45 56 14 03H 0.82
<TS 214 B
51 58 15 03H 0.9
<TS 215 B
59 72 15 03H 1.03
<TS 216 B
63 110 18 03H
-0.23
<TS 217 B
65 110 19 03H 0.67
<TS 218 B
68 113 15 03H 0.86
<TS 219 B
78 81 15 03H 1.01
<TS 220 B
78 109 13 03H 0.88
<TS 221 B
78 109 10 03H 0.08
<TS 222 B
79 86 18 03H 0.65
<TS 223 B
79 122 15 03H 0.94
<TS 224 B
80 73 15 03H
-0.74
<TS 225 B
87 82 20 03H 1.01
<TS 226 B
89 84 19 03H 0.9
<TS 227 B
101 136 15 03H 0.92
<TS 228 B
105 120 15 03H
-0.95
<TS 229 B
107 130 22 03H 0.97
<TS 230 B
115 84 12 03H
-0.75
<TS 231 B
121 104 15 03H 0.77
<TS 50
No.
SG Row Column Depth in Percent Location Elevation Status 232 B
136 77 13 03H 0.88
<TS 233 B
6 137 10 04C
-0.92
<TS 234 B
11 164 25 04C 0.86
<TS 235 B
22 115 12 04C
-0.73
<TS 236 B
41 8
18 04C 0.87
<TS 237 B
44 45 16 04C 0.6
<TS 238 B
46 103 17 04C 0.83
<TS 239 B
47 148 16 04C 0.78
<TS 240 B
48 107 17 04C 0.88
<TS 241 B
49 122 13 04C 0.97
<TS 242 B
56 97 18 04C 0.79
<TS 243 B
56 145 15 04C
-0.78
<TS 244 B
61 114 16 04C 0.94
<TS 245 B
72 113 15 04C 0.82
<TS 246 B
75 42 24 04C 1.02
<TS 247 B
76 121 17 04C 0.76
<TS 248 B
81 148 16 04C 0.81
<TS 249 B
85 110 17 04C 0.59
<TS 250 B
89 60 14 04C
-0.95
<TS 251 B
91 124 20 04C 0.93
<TS 252 B
92 69 15 04C 0.95
<TS 253 B
92 97 18 04C 1.04
<TS 254 B
92 97 11 04C
-0.08
<TS 255 B
94 93 15 04C
-0.16
<TS 256 B
94 93 12 04C
-1.04
<TS 257 B
95 106 22 04C
-0.79
<TS 258 B
96 103 18 04C 0.97
<TS 259 B
96 137 13 04C
-0.31
<TS 260 B
98 27 20 04C
-1.06
<TS 261 B
99 136 19 04C 0.89
<TS 262 B
101 30 16 04C 0.73
<TS 263 B
102 29 14 04C 0.81
<TS 264 B
102 109 12 04C
-0.7
<TS 265 B
105 96 17 04C
-0.93
<TS 266 B
108 35 16 04C 0.68
<TS 267 B
108 35 18 04C
-0.99
<TS 268 B
109 34 23 04C
-0.05
<TS 269 B
109 78 17 04C
-1.02
<TS 270 B
109 132 21 04C
-0.03
<TS 271 B
112 37 29 04C
-0.84
<TS 272 B
113 110 19 04C 0.85
<TS 273 B
116 97 16 04C 0
<TS 274 B
116 111 22 04C
-0.96
<TS 275 B
116 125 18 04C 0.23
<TS 276 B
116 125 19 04C 1.06
<TS 277 B
117 40 20 04C
-0.14
<TS 278 B
118 117 17 04C
-0.05
<TS 51
No.
SG Row Column Depth in Percent Location Elevation Status 279 B
118 123 20 04C
-0.98
<TS 280 B
119 42 20 04C
-0.06
<TS 281 B
119 112 21 04C 0.86
<TS 282 B
124 117 26 04C 0.72
<TS 283 B
131 96 21 04C 0.92
<TS 284 B
131 102 17 04C 0.78
<TS 285 B
1 160 16 04H
-0.24
<TS 286 B
1 160 21 04H 0.77
<TS 287 B
15 154 18 04H 0.99
<TS 288 B
63 70 16 04H 0.84
<TS 289 B
65 62 13 04H
-0.98
<TS 290 B
68 41 20 04H 1.02
<TS 291 B
68 113 14 04H
-0.78
<TS 292 B
68 113 20 04H 0.82
<TS 293 B
71 110 14 04H
-0.97
<TS 294 B
80 95 18 04H 0.85
<TS 295 B
88 23 9
04H 0.83
<TS 296 B
88 23 4
04H
-0.75
<TS 297 B
91 88 17 04H
-0.81
<TS 298 B
96 71 16 04H
-0.84
<TS 299 B
96 71 7
04H
-0.08
<TS 300 B
103 126 17 04H 0.97
<TS 301 B
106 35 16 04H 0.88
<TS 302 B
108 35 26 04H 0.85
<TS 303 B
109 84 12 04H
-0.18
<TS 304 B
109 126 19 04H 0.86
<TS 305 B
113 84 14 04H
-0.8
<TS 306 B
115 104 17 04H
-0.94
<TS 307 B
117 112 22 04H 0.86
<TS 308 B
126 109 20 04H 0.74
<TS 309 B
130 109 18 04H 0.78
<TS 310 B
134 69 17 04H 0.88
<TS 311 B
134 69 14 04H 0.08
<TS 312 B
13 62 15 05C
-1.07
<TS 313 B
15 130 19 05C
-0.72
<TS 314 B
41 12 20 05C 0
<TS 315 B
41 120 4
05C 0.93
<TS 316 B
43 48 18 05C 0.9
<TS 317 B
57 120 13 05C 0.58
<TS 318 B
61 102 15 05C 0
<TS 319 B
77 104 19 05C 0.89
<TS 320 B
84 77 13 05C
-0.97
<TS 321 B
109 132 18 05C 0.89
<TS 322 B
115 124 19 05C
-0.74
<TS 323 B
116 103 21 05C 0.87
<TS 324 B
128 101 26 05C 0.98
<TS 325 B
131 102 21 05C 0.92
<TS 52
No.
SG Row Column Depth in Percent Location Elevation Status 326 B
27 26 16 05H 0.78
<TS 327 B
35 42 15 05H 0.86
<TS 328 B
40 25 16 05H
-0.92
<TS 329 B
77 104 15 05H 0.9
<TS 330 B
85 78 18 05H 0.86
<TS 331 B
92 35 14 05H 0.92
<TS 332 B
92 49 20 05H 0.79
<TS 333 B
92 83 20 05H 0.86
<TS 334 B
116 111 18 05H
-0.94
<TS 335 B
117 68 15 05H 0.97
<TS 336 B
121 104 19 05H 0.68
<TS 337 B
132 81 17 05H 0.93
<TS 338 B
45 148 16 06C
-0.6
<TS 339 B
47 48 13 06C 0.71
<TS 340 B
63 18 17 06C
-0.57
<TS 341 B
67 104 20 06C
-0.13
<TS 342 B
67 134 28 06C
-0.79
<TS 343 B
69 72 17 06C
-0.78
<TS 344 B
70 129 20 06C
-0.9
<TS 345 B
71 136 19 06C
-1.02
<TS 346 B
71 136 11 06C
-0.24
<TS 347 B
72 41 26 06C 0.79
<TS 348 B
72 125 23 06C 0.83
<TS 349 B
100 121 16 06C 0.99
<TS 350 B
124 105 15 06C 0.97
<TS 351 B
127 104 17 06C 0.94
<TS 352 B
127 108 17 06C 0.9
<TS 353 B
129 106 16 06C 0.91
<TS 354 B
129 108 17 06C 0.99
<TS 355 B
131 100 15 06C 0.9
<TS 356 B
131 102 23 06C
-0.87
<TS 357 B
132 101 23 06C 0.84
<TS 358 B
132 101 19 06C
-0.2
<TS 359 B
134 95 18 06C 0.87
<TS 360 B
45 118 16 06H 0.13
<TS 361 B
47 108 24 06H 0.73
<TS 362 B
57 16 14 06H
-0.18
<TS 363 B
59 48 13 06H 0.65
<TS 364 B
61 12 13 06H
-0.25
<TS 365 B
61 144 14 06H 0.92
<TS 366 B
66 17 18 06H 0.74
<TS 367 B
66 21 18 06H 0.75
<TS 368 B
66 149 15 06H 0.89
<TS 369 B
68 143 17 06H 0.84
<TS 370 B
76 27 3
06H
-0.72
<TS 371 B
86 31 10 06H 1.09
<TS 372 B
88 29 10 06H 0.86
<TS 53
No.
SG Row Column Depth in Percent Location Elevation Status 373 B
102 41 13 06H
-0.84
<TS 374 B
102 41 18 06H 0.75
<TS 375 B
129 84 20 06H 0.87
<TS 376 B
81 126 13 07C 0.57
<TS 377 B
97 84 17 07C
-0.95
<TS 378 B
97 84 13 07C
-0.16
<TS 379 B
102 51 16 07C 0.9
<TS 380 B
102 99 12 07C 0.21
<TS 381 B
102 99 18 07C 0.89
<TS 382 B
105 34 14 07C
-0.86
<TS 383 B
105 90 17 07C 0.78
<TS 384 B
106 51 17 07C 0.82
<TS 385 B
107 44 23 07C
-0.23
<TS 386 B
108 115 17 07C 0.83
<TS 387 B
109 62 21 07C 0.77
<TS 388 B
113 70 19 07C 0.87
<TS 389 B
113 70 19 07C 0
<TS 390 B
116 81 9
07C
-0.18
<TS 391 B
116 81 16 07C
-0.97
<TS 392 B
125 104 26 07C
-0.03
<TS 393 B
126 99 18 07C 0.85
<TS 394 B
127 102 19 07C
-0.13
<TS 395 B
127 106 24 07C
-0.13
<TS 396 B
129 104 19 07C 0
<TS 397 B
131 88 18 07C 0.85
<TS 398 B
131 96 12 07C 0.96
<TS 399 B
133 102 21 07C
-0.85
<TS 400 B
135 92 22 07C 0.82
<TS 401 B
136 97 19 070 0.73
<TS 402 B
138 89 20 07C 0.69
<TS 403 B
138 89 11 07C 0
<TS 404 B
84 19 25 07H
-1.03
<TS 405 B
90 69 13 07H
-0.98
<TS 406 B
109 112 20 07H 0.86
<TS 407 B
111 66 15 07H 0.94
<TS 408 B
114 43 18 07H 0.75
<TS 409 B
120 103 22 07H 0.64
<TS 410 B
125 104 22 07H 0.73
<TS 411 B
118 101 15 08C 0
<TS 412 B
119 88 14 08C
-0.1
<TS 413 B
119 88 23 08C 0.78
<TS 414 B
120 61 16 08C 0.77
<TS 415 B
125 100 15 08C 1.05
<TS 416 B
126 99 20 08C 0.95
<TS 417 B
127 92 22 08C
-0.1
<TS 418 B
129 102 23 08C
-0.87
<TS 419 B
129 102 12 08C 0
<TS 54
No.
SG Row Column Depth in Percent Location Elevation Status 420 B
129 106 24 08C 1.01
<TS 421 B
129 106 13 08C
-0.08
<TS 422 B
135 76 16 08C 0.75
<TS 423 B
135 76 18 08C
-1.07
<TS 424 B
135 92 33 08C 0.98
<TS 425 B
136 87 15 08C
-1
<TS 426 B
136 97 21 08C
-1.11
<TS 427 B
136 97 17 08C 0
<TS 428 B
137 92 21 08C
-0.85
<TS 429 B
108 33 26 08H 0.5
<TS 430 B
110 97 16 08H 1.07
<TS 431 B
131 96 15 08H
-0.27
<TS 432 B
137 80 17 08H 1.16
<TS 433 B
13 62 11 DBC
-1.77
<TS 434 B
15 162 13 DBC 1.51
<TS 435 B
21 64 20 DBC
-1.64
<TS 436 B
35 4
30 DBC 1.78
<TS 437 B
39 22 17 DBC 1.29
<TS 438 B
46 29 10 DBC 1.87
<TS 439 B
46 143 12 DBC 1.68
<TS 440 B
57 62 2
DBC 0.87
<TS 441 B
67 46 15 DBC 1.78
<TS 442 B
69 34 22 DBC 1.92
<TS 443 B
71 20 19 DBC 1.19
<TS 444 B
74 23 17 DBC 1.85
<TS 445 B
75 24 13 DBC
-1.82
<TS 446 B
76 29 11 DBC 1.82
<TS 447 B
79 30 15 DBC 1.48
<TS 448 B
83 104 26 DBC 1.35
<TS 449 B
104 31 9
DBC
-1.6
<TS 450 B
107 120 18 DBC 1.82
<TS 451 B
130 91 24 DBC 1.51
<TS 452 B
132 91 19 DBC 1.74
<TS 453 B
134 95 22 DBC 1.46
<TS 454 B
135 94 27 DBC 1.67
<TS 455 B
136 91 23 DBC 1.77
<TS 456 B
137 90 18 DBC 1.72
<TS 457 B
9 46 21 DBH 0.44
<TS 458 B
25 64 13 DBH
-1.73
<TS 459 B
39 108 16 DBH
-1.75
<TS 460 B
44 23 21 DBH
-1.54
<TS 461 B
46 69 13 DBH
-1.89
<TS 462 B
49 74 16 DBH
-1.42
<TS 463 B
50 7
12 DBH 1.57
<TS 464 B
71 20 20 DBH
-1.64
<TS 465 B
72 17 19 DBH 1.92
<TS 466 B
72 149 27 DBH 1.63
<TS 55
No.
SG Row Column Depth in Percent Location Elevation Status 467 B
74 127 18 DBH
-1.51
<TS 468 B
76 15 20 DBH 1.85
<TS 469 B
76 35 16 DBH 1.58
<TS 470 B
76 127 16 DBH
-1.72
<TS 471 B
76 141 22 DBH 1.78
<TS 472 B
77 150 28 DBH 2.18
<TS 473 B
78 23 14 DBH
-1.57
<TS 474 B
80 17 25 DBH 1.99
<TS 475 B
99 138 7
DBH 1.95
<TS 476 B
101 104 17 DBH 1.62
<TS 477 B
105 110 15 DBH 0.57
<TS 478 B
108 33 18 DBH
-1.6
<TS 479 B
114 37 23 DBH 1.08
<TS 480 B
134 63 17 DBH
-1.79
<TS 481 B
137 90 24 DBH 1.78
<TS 482 B
138 85 27 DBH 1.86
<TS 483 B
119 104 20 VS1
-0.72
<TS 484 B
124 93 15 VS1 0.7
<TS 485 B
128 73 25 VS1 all
<15 486 B
138 79 26 VS1
-0.5
<TS 487 B
138 87 21 VS1
-0.71
<TS 488 B
138 87 14 VS1 0.99
<TS 489 B
88 67 16 VS2 0.8
<TS 490 B
88 67 14 VS2
-0.8
<TS 491 B
89 38 17 VS2
-0.78
<TS 492 B
92 73 8
VS2 0.74
<TS 493 B
94 37 14 VS2
-0.7
<TS 494 B
95 116 17 VS2
-0.91
<TS 495 B
96 95 15 VS2 0.12
<TS 496 B
96 95 23 VS2
-0.75
<TS 497 B
96 95 21 VS2 0.75
<TS 498 B
97 42 18 VS2
-0.91
<TS 499 B
97 60 16 VS2 0.89
<TS 500 B
98 41 16 VS2
-0.85
<TS 501 B
98 41 19 VS2 1
<TS 502 B
98 49 22 VS2
-0.43
<TS 503 B
98 55 30 VS2
-0.89
<TS 504 B
98 59 17 VS2
-0.86
<TS 505 B
98 59 14 VS2 0.89
<TS 506 B
98 71 10 VS2
-0.87
<TS 507 B
98 71 15 VS2 0.99
<TS 508 B
98 81 12 VS2 0.75
<TS 509 B
98 135 21 VS2 0
<TS 510 B
99 132 26 VS2 0.85
<TS 511 B
99 132 24 VS2
-0.79
<TS 512 B
100 109 24 VS2
-0.48
<TS 513 B
100 1
55 33 VS2
-0.58
<TS 56
No.
SG Row Column Depth in Percent Location Elevation Status 514 B
100 125 28 VS2
-0.11
<TS 515 B
101 32 18 VS2 0.72
<TS 516 B
102 49 17 VS2 1.16
<TS 517 B
103 64 26 VS2 1.01
<TS 518 B
103 94 14 VS2 0.96
<TS 519 B
103 94 21 VS2
-0.65
<TS 520 B
103 126 22 VS2 0.25
<TS 521 B
103 130 19 VS2
-0.27
<TS 522 B
103 132 12 VS2 0
<TS 523 B
104 95 20 VS2
-0.63
<TS 524 B
104 95 17 VS2 0.9
<TS 525 B
104 95 16 VS2 0.13
<TS 526 B
105 58 23 VS2
-0.74
<TS 527 B
105 76 16 VS2 1.01
<TS 528 B
105 78 13 VS2 0.9
<TS 529 B
105 80 22 VS2
-0.21
<TS 530 B
105 90 20 VS2 0.95
<TS 531 B
105 130 18 VS2
-0.59
<TS 532 B
105 130 13 VS2
-0.18
<TS 533 B
105 130 14 VS2 0.83
<TS 534 B
106 37 19 VS2
-0.5
<TS 535 B
106 39 25 VS2
-0.61
<TS 536 B
106 63 22 VS2 0
<TS 537 B
106 71 16 VS2
-0.29
<TS 538 B
106 75 17 VS2 0.7
<TS 539 B
106 77 22 VS2 1.03
<TS 540 B
106 101 16 VS2
-0.77
<TS 541 B
106 113 16 VS2
-0.2
<TS 542 B
107 36 19 VS2 1.06
<TS 543 B
107 40 22 VS2 0.92
<TS 544 B
107 40 16 VS2
-0.84
<TS 545 B
107 42 36 VS2 0.98
<TS 546 B
107 42 33 VS2
-0.88
<TS 547 B
107 78 12 VS2
-0.91
<TS 548 B
107 78 19 VS2 0.91
<TS 549 B
107 82 31 VS2
-0.82
<TS 550 B
107 82 27 VS2 0.98
<TS 551 B
107 96 27 VS2 0.98
<TS 552 B
107 116 27 VS2 0.91
<TS 553 B
107 116 18 VS2 0.28
<TS 554 B
107 116 24 VS2
-0.66
<TS 555 B
108 47 22 VS2
-0.88
<TS 556 B
108 51 25 VS2
-0.84
<TS 557 B
108 51 16 VS2 0.83
<TS 558 B
108 59 20 VS2 0.98
<TS 559 B
108 59 20 VS2
-0.84
<TS 560 B
109 40 21 VS2
-0.79
<TS 57
No.
SG Row Column Depth in Percent Location Elevation Status 561 B
109 40 19 VS2 0.83
<TS 562 B
109 52 34 VS2 0.84
<TS 563 B
109 52 17 VS2
-0.91
<TS 564 B
109 104 27 VS2 0.92
<TS 565 B
109 114 17 VS2 0.3
<TS 566 B
109 114 26 VS2
-0.03
<TS 567 B
110 55 27 VS2
-0.88
<TS 568 B
110 79 21 VS2
-0.06
<TS 569 B
111 50 18 VS2 0.99
<TS 570 B
112 43 17 VS2 0.82
<TS 571 B
112 43 24 VS2
-0.92
<TS 572 B
112 47 28 VS2
-0.94
<TS 573 B
112 47 14 VS2 0.96
<TS 574 B
112 53 13 VS2 0.78
<TS 575 B
112 53 16 VS2
-0.97
<TS 576 B
112 59 13 VS2 0
<TS 577 B
112 59 14 VS2 0.68
<TS 578 B
112 59 15 VS2
-0.63
<TS 579 B
112 71 15 VS2
-0.77
<TS 580 B
112 79 20 VS2 0.66
<TS 581 B
113 48 35 VS2
-0.94
<TS 582 B
114 37 22 VS2
-0.73
<TS 583 B
114 37 25 VS2 0.21
<TS 584 B
114 39 23 VS2
-0.71
<TS 585 B
116 55 12 VS2
-0.86
<TS 586 B
116 77 16 VS2 0.64
<TS 587 B
118 87 13 VS2 0.93
<TS 588 B
118 89 27 VS2 0.92
<TS 589 B
118 97 16 VS2
-0.97
<TS 590 B
120 105 23 VS2
-0.86
<TS 591 B
120 113 24 VS2
-0.99
<TS 592 B
120 113 21 VS2 0.9
<TS 593 B
124 93 18 VS2 0.73
<TS 594 B
124 93 29 VS2 0.08
<TS 595 B
124 93 22 VS2
-0.71
<TS 596 B
125 94 23 VS2
-0.72
<TS 597 B
126 87 28 VS2 0.97
<TS 598 B
130 77 24 VS2 0.98
<TS 599 B
132 97 14 VS2
-0.89
<TS 600 B
132 97 17 VS2
-0.48
<TS 601 B
138 79 23 VS2 0.68
<TS 602 B
63 126 13 VS3 0.94
<TS 603 B
66 41 19 VS3
-0.76
<TS 604 B
66 147 14 VS3
-0.72
<TS 605 B
66 147 10 VS3 0.85
<TS 606 B
67 138 26 VS3 0.05
<TS 607 B
67 150 22 VS3 0.85
<TS 58
No.
SG Row Column Depth in Percent Location Elevation Status 608 B
67 150 18 VS3
-0.73
<TS 609 B
68 151 22 VS3
-0.56
<TS 610 B
69 52 23 VS3 0.08
<TS 611 B
69 134 17 VS3
-0.75
<TS 612 B
69 144 16 VS3
-0.93
<TS 613 B
69 150 25 VS3
-0.73
<TS 614 B
69 150 19 VS3 0.9
<TS 615 B
70 141 19 VS3
-0.81
<TS 616 B
70 147 16 VS3
-0.57
<TS 617 B
71 36 18 VS3 0.83
<TS 618 B
71 36 13 VS3
-0.28
<TS 619 B
71 144 24 VS3
-0.63
<TS 620 B
71 144 14 VS3 1.01
<TS 621 B
72 25 10 VS3 0
<TS 622 B
72 25 20 VS3
-0.64
<TS 623 B
72 55 19 VS3
-0.74
<TS 624 B
74 17 22 VS3
-0.65
<TS 625 B
74 17 17 VS3 0.85
<TS 626 B
74 23 19 VS3
-0.78
<TS 627 B
74 43 18 VS3
-0.81
<TS 628 B
74 117 18 VS3
-0.82
<TS 629 B
76 21 15 VS3 0.96
<TS 630 B
76 29 12 VS3
-0.74
<TS 631 B
76 29 19 VS3
-0.16
<TS 632 B
76 29 17 VS3 0.47
<TS 633 B
76 59 18 VS3
-0.83
<TS 634 B
77 34 12 VS3 0.23
<TS 635 B
77 34 16 VS3 0.82
<TS 636 B
77 150 13 VS3
-0.9
<TS 637 B
78 61 18 VS3
-0.84
<TS 638 B
80 47 16 VS3
-0.51
<TS 639 B
80 115 14 VS3 0.92
<TS 640 B
81 22 26 VS3 0.89
<TS 641 B
81 24 16 VS3
-0.87
<TS 642 B
81 24 10 VS3 0.83
<TS 643 B
81 52 30 VS3 0.83
<TS 644 B
82 41 24 VS3 0.88
<TS 645 B
82 43 23 VS3 0.75
<TS 646 B
82 43 19 VS3
-0.16
<TS 647 B
82 43 25 VS3 0.21
<TS 648 B
82 143 24 VS3
-0.67
<TS 649 B
82 145 22 VS3
-0.79
<TS 650 B
82 145 17 VS3 0.99
<TS 651 B
22 133 19 VS4 0.99
<TS 652 B
22 133 10 VS4
-0.97
<TS 653 B
27 64 14 VS4
-0.03
<TS 654 B
28 39 20 VS4 0.86
<TS 59
No.
SG Row Column Depth in Percent Location Elevation Status 655 B
28 63 18 VS4 0.02
-TS 656 B
30 45 10 VS4 0.54
<TS 657 B
33 12 19 VS4 1.2
<TS 658 B
33 12 10 VS4
-0.66
<TS 659 B
34 11 11 VS4 1
<TS 660 B
34 11 13 VS4 0
<TS 661 B
34 31 19 VS4 0.69
<TS 662 B
34 31 19 VS4 0.69
<TS 663 B
35 36 18 VS4 0.76
<TS 664 B
36 45 18 VS4
-0.84
<TS 665 B
36 51 10 VS4
-0.88
<TS 666 B
36 51 14 VS4 1.11
<TS 667 B
37 12 16 VS4
-0.93
<TS 668 B
37 122 22 VS4
-0.88
<TS 669 B
37 124 22 VS4
-0.97
<TS 670 B
37 124 25 VS4 1.19
<TS 671 B
37 128 19 VS4 1.02
<TS 672 B
37 128 19 VS4
-0.88
<TS 673 B
37 148 26 VS4
-1.01
<TS 674 B
37 156 24 VS4 1.02
<TS 675 B
37 156 20 VS4
-1.02
<TS 676 B
37 160 22 VS4 0.95
<TS 677 B
37 160 18 VS4
-0.5
<TS 678 B
38 13 21 VS4 0.93
<TS 679 B
38 49 21 VS4 0.78
<TS 680 B
38 51 18 VS4
-0.93
<TS 681 B
38 53 12 VS4 0.62
<TS 682 B
38 109 12 VS4
-0.59
<TS 683 B
38 125 34 VS4 0.97
<TS 684 B
38 125 13 VS4
-1
<TS 685 B
38 127 28 VS4 0.96
<TS 686 B
38 131 22 VS4 0.96
<TS 687 B
38 131 11 VS4
-1.07
<TS 688 B
38 135 15 VS4 0.16
<TS 689 B
38 145 21 VS4 0.99
<TS 690 B
38 145 15 VS4
-1.05
<TS 691 B
38 147 30 VS4
-1.11
<TS 692 B
38 147 15 VS4 1.01
<TS 693 B
39 102 20 VS4
-0.92
<TS 694 B
39 116 37 VS4 1.06
<TS 695 B
39 116 20 VS4
-0.92
<TS 696 B
39 120 25 VS4 0.98
<TS 697 B
39 132 36 VS4 0.99
<TS 698 B
39 134 22 VS4
-1
<TS 699 B
39 134 12 VS4 0.95
<TS 700 B
39 150 22 VS4 0.87
<TS 701 B
40 31 14 VS4 0.71
<TS 60
No.
SG Row Column Depth in Percent Location Elevation Status 702 B
40 121 16 VS4
-0.97
<TS 703 B
40 121 25 VS4 0.91
<TS 704 B
40 123 23 VS4 0.97
<TS 705 B
41 12 19 VS4 0
<TS 706 B
41 12 11 VS4
-0.34
<TS 707 B
41 12 24 VS4 0.88
<TS 708 B
41 14 23 VS4 0.12
<TS 709 B
41 14 16 VS4 0.65
<TS 710 B
41 54 31 VS4 0.8
<TS 711 B
41 54 17 VS4
-0.74
<TS 712 B
41 122 12 VS4 0.91
<TS 713 B
41 122 15 VS4
-0.97
<TS 714 B
41 132 19 VS4 1.05
<TS 715 B
42 27 17 VS4
-0.49
<TS 716 B
42 41 22 VS4
-0.84
<TS 717 B
42 41 33 VS4 0.95
<TS 718 B
42 41 28 VS4 0.25
<TS 719 B
42 51 21 VS4 0.94
<TS 720 B
42 51 35 VS4
-0.91 -
TS 721 B
42 57 16 VS4 0.27
<TS 722 B
42 57 30 VS4 0.79
<TS 723 B
42 123 32 VS4 0.99
<TS 724 B
43 132 14 VS4 0.92
<TS 725 B
44 21 26 VS4
-0.91
<TS 726 B
44 21 31 VS4 0.91
<TS 727 B
44 23 13 VS4 0.99
<TS 728 B
44 27 22 VS4
-0.82
<TS 729 B
44 27 22 VS4 1.02
<TS 730 B
44 29 20 VS4
-0.2
<TS 731 B
44 29 21 VS4 0.64
<TS 732 B
44 31 19 VS4 0.37
<TS 733 B
44 31 33 VS4
-0.8
<TS 734 B
44 37 24 VS4 0.28
<TS 735 B
44 37 21 VS4
-0.28
<TS 736 B
44 37 19 VS4 0.84
<TS 737 B
44 45 20 VS4 0.97
<TS 738 B
44 47 24 VS4
-0.51
<TS 739 B
44 57 17 VS4
-0.76
<TS 740 B
44 57 11 VS4 0.14
<TS 741 B
44 59 21 VS4
-0.95
<TS 742 B
44 59 17 VS4 0.91
<TS 743 B
44 63 24 VS4 0.99
<TS 744 B
44 63 16 VS4
-0.88
<TS 745 B
44 65 18 VS4
-0.2
<TS 746 B
44 65 21 VS4 0.96
<TS 747 B
44 65 14 VS4 0.28
<TS 748 B
44 103 32 VS4 0.72
<TS 61
No.
SG Row Column Depth in Percent Location Elevation Status 749 B
44 107 25 VS4 0.76
<TS 750 B
44 107 20 VS4
-1.07
<TS 751 B
45 32 18 VS4 0.94
<TS 752 B
45 32 19 VS4 0.15
<TS 753 B
45 32 22 VS4
-0.85
<TS 754 B
45 34 17 VS4
-0.59
<TS 755 B
45 34 21 VS4
-0.14
<TS 756 B
45 34 21 VS4 0.48
<TS 757 B
45 36 21 VS4
-0.03
<TS 758 B
45 36 16 VS4 0.86
<TS 759 B
45 42 24 VS4
-0.68
<TS 760 B
45 42 19 VS4 1.13
<TS 761 B
45 48 13 VS4
-0.97
<TS 762 B
45 48 17 VS4 0.66
<TS 763 B
45 48 17 VS4 0.22
<TS 764 B
45 120 16 VS4
-0.76
<TS 765 B
45 122 24 VS4
-0.96
<TS 766 B
45 122 32 VS4 1.1
<TS 767 B
45 130 14 VS4 1.09
<TS 768 B
45 132 11 VS4 0.93
<TS 769 B
45 140 26 VS4 1.03
<TS 770 B
45 140 8
VS4
-0.91
<TS 771 B
45 148 17 VS4 0.82
<TS 772 B
46 23 16 VS4
-0.85
<TS 773 B
46 23 20 VS4 0.69
<TS 774 B
46 25 13 VS4
-0.74
<TS 775 B
46 33 23 VS4
-0.6
<TS 776 B
46 33 8
VS4 0.26
<TS 777 B
46 35 17 VS4
-0.69
<TS 778 B
46 37 13 VS4
-0.59
<TS 779 B
46 37 18 VS4 0.94
<TS 780 B
46 39 12 VS4
-0.45
<TS 781 B
46 39 11 VS4 0.17
<TS 782 B
46 39 18 VS4 0.45
<TS 783 B
46 129 18 VS4 0.81
<TS 784 B
46 135 10 VS4
-0.86
<TS 785 B
46 151 32 VS4 0.84
<TS 786 B
47 12 22 VS4 0.91
<TS 787 B
47 12 15 VS4
-0.7
<TS 788 B
47 14 15 VS4
-0.17
<TS 789 B
47 14 24 VS4 0.82
<TS 790 B
47 20 24 VS4
-0.68
<TS 791 B
47 20 25 VS4 0.68
<TS 792 B
47 22 19 VS4
-0.61
<TS 793 B
47 22 16 VS4 0.96
<TS 794 B
47 46 11 VS4 1.1
<TS 795 B
47 46 17 VS4
-0.33
<TS 62
No.
SG Row Column Depth in Percent Location Elevation Status 796 B
47 46 21 VS4 0.11
<TS 797 B
47 56 14 VS4
-0.79
<TS 798 B
47 56 25 VS4 0.73
<TS 799 B
47 58 16 VS4 0.81
<TS 800 B
47 58 7
VS4
-0.84
<TS 801 B
47 70 11 VS4
-0.56
<TS 802 B
47 96 23 VS4 0.93
<TS 803 B
47 96 17 VS4
-0.83
<TS 804 B
47 98 25 VS4 0.9
<TS 805 B
47 108 24 VS4 0.91
<TS 806 B
47 108 10 VS4 0.16
<TS 807 B
47 108 20 VS4
-0.87
<TS 808 B
47 126 30 VS4
-0.89
<TS 809 B
47 126 32 VS4 0.98
<TS 810 B
47 128 26 VS4
-0.85
<TS 811 B
47 132 18 VS4 1.06
<TS 812 B
47 132 12 VS4
-0.67
<TS 813 B
47 140 16 VS4 0.87
<TS 814 B
48 9
26 VS4 0.24
<TS 815 B
48 9
27 VS4
-0.81
<TS 816 B
48 9
17 VS4 0.82
<TS 817 B
48 13 21 VS4
-0.71
<TS 818 B
48 13 26 VS4 0
<TS 819 B
48 13 18 VS4 0.87
<TS 820 B
48 65 20 VS4
-0.59
<TS 821 B
48 67 21 VS4 0
<TS 822 B
49 8
24 VS4 0.89
<TS 823 B
49 34 13 VS4
-0.77
<TS 824 B
49 34 26 VS4 0.77
<TS 825 B
49 46 15 VS4
-0.64
<TS 826 B
49 106 18 VS4 0.3
<TS 827 B
63 82 27 VS4 1.18
<TS 828 B
69 52 23 VS4
-0.7
<TS 829 B
69 52 18 VS4 0.76
<TS 830 B
69 52 20 VS4 0.03
<TS 831 B
69 134 26 VS4 0.91
<TS 832 B
69 134 31 VS4
-0.8
<TS 833 B
69 150 13 VS4 1
<TS 834 B
70 13 13 VS4
-0.79
<TS 835 B
70 153 17 VS4 0.95
<TS 836 B
70 153 17 VS4
-0.84
<TS 837 B
71 14 16 VS4 1.02
<TS 838 B
71 36 18 VS4 0.93
<TS 839 B
71 146 16 VS4 0.93
<TS 840 B
71 152 12 VS4 0.93
<TS 841 B
73 14 12 VS4
-0.82
<TS 842 B
73 14 15 VS4 0.16
<TS 63
No.
SG Row Column Depth in Percent Location Elevation Status 843 B
74 17 24 VS4
-0.9
<TS 844 B
74 23 15 VS4
-0.76
<TS 845 B
74 43 17 VS4
-0.55
<TS 846 B
76 21 28 VS4 0.98
<TS 847 B
76 21 16 VS4
-0.78
<TS 848 B
76 29 20 VS4 0
<TS 849 B
77 48 23 VS4 0.91
<TS 850 B
77 150 20 VS4
-0.92
<TS 851 B
77 150 23 VS4 0.9
<TS 852 B
79 24 25 VS4 0.9
<TS 853 B
79 24 23 VS4
-0.06
<TS 854 B
79 84 17 VS4
-0.91
<TS 855 B
80 115 20 VS4
-0.96
<TS 856 B
80 145 31 VS4
-0.79
<TS 857 B
81 22 22 VS4 0.84
<TS 858 B
81 148 16 VS4
-0.88
<TS 859 B
81 148 16 VS4 0.91
<TS 860 B
82 143 16 VS4
-0.67
<TS 861 B
82 145 17 VS4
-0.94
<TS 862 B
82 145 27 VS4 1.05
<TS 863 B
83 148 27 VS4
-0.74
<TS 864 B
87 20 18 VS4
-0.74
<TS 865 B
87 20 8
VS4 0.81
<TS 866 B
87 146 20 VS4
-0.8
<TS 867 B
91 144 18 VS4
-0.87
<TS 868 B
91 144 12 VS4 0.87
<TS 869 B
92 23 13 VS4
-0.9
<TS 870 B
92 23 11 VS4 0.66
<TS 871 B
93 30 17 VS4
-0.91
<TS 872 B
95 24 13 VS4 0.62
<TS 873 B
95 24 15 VS4
-0.75
<TS 874 B
95 36 16 VS4 0.94
<TS 875 B
95 36 16 VS4
-1.06
<TS 876 B
95 138 23 VS4
-0.71
<TS 877 B
95 138 37 VS4 0.96
<TS 878 B
95 142 20 VS4 1.03
<TS 879 B
96 29 13 VS4 1
<TS 880 B
96 137 24 VS4 1.04
<TS 881 B
96 137 16 VS4
-0.19
<TS 882 B
96 141 19 VS4 0.95
<TS 883 B
97 140 7
VS4
-0.92
<TS 884 B
98 41 26 VS4 0.71
<TS 885 B
98 81 21 VS4
-0.78
<TS 886 B
98 135 24 VS4 0.92
<TS 887 B
98 135 20 VS4
-0.89
<TS 888 B
98 139 21 VS4 0.93
<TS 889 B
98 139 22 VS4 0.19
<TS 64
No.
SG Row Column Depth in Percent Location Elevation Status 890 B
98 139 13 VS4
-0.61
<TS 891 B
99 132 18 VS4 0.9
<TS 892 B
99 132 20 VS4
-0.9
<TS 893 B
100 27 26 VS4
-0.86
<TS 894 B
100 27 9
VS4 0.75
<TS 895 B
100 125 18 VS4
-0.86
<TS 896 B
100 125 26 VS4 1.03
<TS 897 B
100 133 9
VS4
-0.66
<TS 898 B
102 31 16 VS4 0.71
<TS 899 B
102 137 19 VS4 1.02
<TS 900 B
102 137 15 VS4
-0.71
<TS 901 B
103 48 24 VS4
-0.76
<TS 902 B
103 136 21 VS4
-0.84
<TS 903 B
103 136 17 VS4 0.88
<TS 904 B
104 31 19 VS4 0.97
<TS 905 B
104 135 13 VS4 1.07
<TS 906 B
105 30 28 VS4 0.94
<TS 907 B
105 30 15 VS4 0.27
<TS 908 B
105 90 21 VS4 0.8
<TS 909 B
106 31 24 VS4 1.02
<TS 910 B
106 31 15 VS4 0.4
<TS 911 B
107 32 14 VS4
-0.91
<TS 912 B
107 42 25 VS4 0.2
<TS 913 B
107 42 33 VS4 0.85
<TS 914 B
107 96 17 VS4 0.55
<TS 915 B
108 43 22 VS4
-0.9
<TS 916 B
108 113 26 VS4
-0.88
<TS 917 B
108 113 25 VS4 0.98
<TS 918 B
109 34 23 VS4
-0.65
<TS 919 B
109 114 35 VS4
-0.8
<TS 920 B
110 35 24 VS4 0.98
<TS 921 B
111 36 22 VS4
-0.91
<TS 922 B
111 56 14 VS4
-0.71
<TS 923 B
111 130 25 VS4 0.87
<TS 924 B
112 43 20 VS4
-0.85
<TS 925 B
112 47 23 VS4 0.94
<TS 926 B
113 40 19 VS4
-0.78
<TS 927 B
113 42 21 VS4 0.89
<TS 928 B
113 48 11 VS4 0.75
<TS 929 B
113 48 37 VS4
-0.77
<TS 930 B
113 130 17 VS4
-0.9
<TS 931 B
114 37 16 VS4
-0.77
<TS 932 B
114 37 26 VS4 0.97
<TS 933 B
114 39 36 VS4 0.81
<TS 934 B
115 128 15 VS4
-0.81
<TS 935 B
116 43 23 VS4 1
<TS 936 B
116 47 15 VS4 0.99
<TS 65
No.
SG Row Column Depth in Percent Location Elevation Status 937 B
116 55 17 VS4 0.93
<TS 938 B
116 115 23 VS4 1.06
<TS 939 B
118 43 21 VS4 1.03
<TS 940 B
118 89 20 VS4 0.68
<TS 941 B
118 105 19 VS4
-0.6
<TS 942 B
121 114 16 VS4
-0.89
<TS 943 B
123 72 17 VS4
-0.98
<TS 944 B
124 51 16 VS4 0.56
<TS 945 B
124 85 17 VS4
-0.56
<TS 946 B
124 93 14 VS4 0.92
<TS 947 B
124 93 17 VS4
-0.84
<TS 948 B
124 95 23 VS4 0.92
<TS 949 B
124 95 19 VS4
-0.95
<TS 950 B
125 48 16 VS4 0.78
<TS 951 B
125 48 13 VS4
-0.84
<TS 952 B
125 116 20 VS4
-0.83
<TS 953 B
126 81 17 VS4
-0.83
<TS 954 B
126 87 33 VS4
-0.78
<TS 955 B
126 87 15 VS4 0.86
<TS 956 B
126 95 25 VS4
-0.96
<TS 957 B
126 103 20 VS4 0.76
<TS 958 B
128 73 17 VS4 0.79
<TS 959 B
130 65 15 VS4 0.66
<TS 960 B
130 77 14 VS4
-0.73
<TS 961 B
132 97 19 VS4
-0.91
<TS 962 B
132 97 11 VS4 0.62
<TS 963 B
137 90 16 VS4 0.87
<TS 964 B
138 77 20 VS4 0.84
<TS 965 B
138 79 21 VS4 0.88
<TS 966 B
138 81 22 VS4
-0.91
<TS 967 B
138 87 19 VS4
-0.61
<TS 968 B
138 89 20 VS4
-0.68
<TS 969 B
51 156 24 VS5
-0.98
<TS 970 B
58 47 9
VS5
-0.68
<TS 971 B
62 23 16 VS5 0.91
<TS 972 B
63 82 24 VS5 1.04
<TS 973 B
63 82 12 VS5
-0.2
<TS 974 B
63 136 14 VS5 0.91
<TS 975 B
64 51 14 VS5 0.21
<TS 976 B
64 51 15 VS5 0.99
<TS 977 B
66 39 18 VS5
-0.79
<TS 978 B
66 105 14 VS5 0.93
<TS 979 B
68 21 9
VS5
-1.01
<TS 980 B
68 151 12 VS5 1.12
<TS 981 B
69 52 18 VS5 1.15
<TS 982 B
69 52 19 VS5
-0.91
<TS 983 B
69 134 14 VS5
-0.77
<TS 66
No.
SG Row Column Depth in Percent Location Elevation Status 984 B
69 134 13 VS5 0.94
<TS 985 B
69 136 16 VS5 0.97
<TS 986 B
69 136 18 VS5
-0.97
<TS 987 B
69 140 18 VS5
-0.94
<TS 988 B
69 140 11 VS5 0.94
<TS 989 B
69 144 25 VS5
-0.92
<TS 990 B
69 150 18 VS5 0.81
<TS 991 B
71 20 18 VS5 1
<TS 992 B
71 36 21 VS5 0.25
<TS 993 B
71 36 19 VS5
-0.68
<TS 994 B
71 132 11 VS5 1.13
<TS 995 B
71 146 30 VS5
-0.79
<TS 996 B
71 152 15 VS5 0.98
<TS 997 B
74 45 20 VS5
-0.8
<TS 998 B
80 47 16 VS5 0.97
<TS 999 B
80 145 18 VS5 0.73
<TS 1000 B
80 145 12 VS5
-0.9
<TS 1001 B
82 21 16 VS5
-0.61
<TS 1002 B
82 43 24 VS5
-0.03
<TS 1003 B
82 43 26 VS5 0.3
<TS 1004 B
82 43 29 VS5
-0.79
<TS 1005 B
83 28 13 VS6 0.46
<TS 1006 B
83 28 23 VS6
-0.93
<TS 1007 B
85 82 10 VS6
-0.77
<TS 1008 B
91 22 25 VS6 0.94
<TS 1009 B
95 70 18 VS6
-0.79
<TS 1010 B
97 34 10 VS6
-0.77
<TS 1011 B
100 29 17 VS6
-0.96
<TS 1012 B
100 125 22 VS6 0.79
<TS 1013 B
100 125 19 VS6 0
<TS 1014 B
102 85 27 VS6
-0.95
<TS 1015 B
103 108 20 VS6
-0.62
<TS 1016 B
103 126 28 VS6 0.99
<TS 1017 B
105 54 21 VS6
-0.98
<TS 1018 B
105 58 17 VS6 0.71
<TS 1019 B
105 78 26 VS6 0.95
<TS 1020 B
105 78 24 VS6
-1.13
<TS 1021 B
107 34 13 VS6
-0.77
<TS 1022 B
107 42 20 VS6
-0.79
<TS 1023 B
107 46 19 VS6
-1.01
<TS 1024 B
107 46 8
VS6 0.88
<TS 1025 B
107 52 15 VS6
-0.67
<TS 1026 B
109 52 15 VS6 0.98
<TS 1027 B
109 114 30 VS6
-0.95
<TS 1028 B
109 114 10 VS6 0.71
<TS 1029 B
111 56 10 VS6
-0.72
<TS 1030 B
113 36 17 VS6
-0.75
<TS 67
No.
SG Row Column Depth in Percent Location Elevation Status 1031 B
113 36 13 VS6 0.69
<TS 1032 B
114 39 20 VS6
-0.61
<TS 1033 B
118 43 21 VS6
-0.14
<TS 1034 B
118 73 14 VS6
-0.96
<TS 1035 B
123 116 36 VS6
-0.8
<TS 1036 B
123 118 30 VS6
-1.01
<TS 1037 B
125 48 19 VS6 0.95
<TS 1038 B
126 87 17 VS6 1.05
<TS 1039 B
126 95 22 VS6 1.04
<TS 1040 B
127 92 14 VS6
-0.98
<TS 1041 B
131 98 27 VS6 0.92
<TS 1042 B
133 106 28 VS6 0.75
<TS 1043 B
133 106 38 VS6
-0.03
<TS 1044 B
134 97 19 VS6 0.85
<TS 1045 B
134 97 16 VS6
-0.93
<TS 1046 B
134 99 26 VS6 0.83
<TS 1047 B
134 99 17 VS6
-0.89
<TS 1048 B
137 90 19 VS6
-0.71
<TS 1049 B
137 92 22 VS6 1.12
<TS 1050 B
137 92 21 VS6
-0.72
<TS 1051 B
138 79 18 VS6 0.88
<TS 1052 B
138 79 19 VS6
-0.85
<TS 1053 B
138 89 16 VS6
-0.88
<TS 1054 B
138 89 17 VS6 0.88
<TS 1055 B
138 89 8
VS6
-1.07
<TS 1056 B
116 81 20 VS7
-1.03
<TS 1057 B
118 73 15 VS7
-0.98
<TS 1058 B
119 42 21 VS7
-0.84
<TS 1059 B
123 118 18 VS7
-0.71
<TS 1060 B
124 57 15 VS7
-0.88
<TS 1061 B
124 117 21 VS7
-0.14
<TS 1062 B
130 65 26 VS7 0.9
<TS 1063 B
131 64 24 VS7 0.93
<TS 1064 B
131 98 29 VS7 0.78
<TS 1065 B
131 104 29 VS7 0.88
<TS 1066 B
132 97 17 VS7 0.85
<TS 1067 B
132 101 18 VS7 0.76
<TS 1068 B
133 100 22 VS7 0.2
<TS 1069 B
133 104 23 VS7 0.91
<TS 1070 B
133 106 22 VS7
-0.89
<TS 1071 B
134 69 9
VS7
-1.01
<TS 1072 B
134 69 26 VS7 1.04
<TS 1073 B
134 101 24 VS7 0.97
<TS 1074 B
135 68 21 VS7 0.87
<TS 1075 B
135 72 12 VS7 0.64
<TS 1076 B
135 72 16 VS7
-0.83
<TS 1077 B
135 76 17 VS7
-0.84
<TS 68
No.
SG Row Column Depth in Percent Location Elevation Status 1078 B
135 82 25 VS7 1
<TS 1079 B
135 82 20 VS7
-0.92
<TS 1080 B
135 90 29 VS7 0.65
<TS 1081 B
135 92 35 VS7
-0.7
<TS 1082 B
136 97 29 VS7
-0.91
<TS 1083 B
136 97 17 VS7 0.91
<TS 1084 B
137 90 21 VS7 0.89
<TS 1085 B
137 90 22 VS7
-0.87
<TS 1086 B
137 92 23 VS7
-0.74
<TS 1087 B
138 89 9
VS7
-0.96
<TS 1088 B
138 89 16 VS7
-0.82
<TS 1089 B
138 89 31 VS7 0.95
<TS 69
Table 5 Tube Plugging Summary by Damage Mechanism TUBE PLUGGING
SUMMARY
SG E-50A SG E-50B Wear - Vertical Straps 1
0 Wear - Diagonal Bar 0
0 Wear - Loose Part 1
1 Wear - Dent (could not be sized TBP) 1 0
Wear - Tube to Tube (TBP) 1 0
Wear - Volumetric 0
0 Possible Loose Part (TBP) 1 0
Circumferential ODSCC TTS 0
3 Axial ODSCC TTS 2
3 Axial ODSCC Freespan 0
0 Axial ODSCC Eggcrate 6
1 Axial ODSCC in Greater Than 5Volt Dents 0
1 Axial PWSCC Tubesheet 1
1 Restricted Tube 0
0 Administrative (TBP) 0 0
2007 Outage Total 14 10 Pre-service Tubes Plugged 308 309 Effective Tubes Plugged 416 383 Effective Tubes Plugged Percentage 5.1%
4.7%
70
Table 6 Condition Monitoring Results Identification of Tubes Plugged (all conditions for tubes that were plugged in the 2007 refueling outage)
SG Row Column Location Reason For Plugging E-50A 39 22 01 H + 0.67" Single Axial Indication (SAI) Dent ODSCC E-50A 89 22 VS2 + 0.84" Wear coincident with a dent (SVI)
E-50A 59 28 TSH + 0.34" Single Axial Indication (SAI) Sludge pile ODSCC E-50A 136 77 DBC + 1.84" Wear from possible tube to tube contact (SVI)
E-50A 121 82 02H + 0.67" Single Axial Indication (SAI) ODSCC E-50A 116 89 VS6 +0.92" 41 % Vertical Strap Wear E-50A 107 96 02H + 0.96 Single Axial Indication (SRI) ODSCC E-50A 71 98 TSH + 0.52" Single Axial Indication (SAI) Sludge pile ODSCC E-50A 92 99 07H - 0.94" Single Axial Indication (SAI) ODSCC E-50A 33 102 TSH - 4.41" Single Axial Indication (SAI) PWSCC E-50A 129 108 08C + 1.78" Possible Loose Part (PLP)with Wear (SVI)
E-50A 128 109 08C +2.26" Possible Loose Part (PLP)
E-50A 15 126 01 H + 0.80" Single Axial Indication (SAI) ODSCC E-50A 53 126 02H + 0.82" Single Axial Indication (SAI) ODSCC E-50B 70 13 VS4 - 1.66" Possible Loose Part (PLP)with Wear (SVI)
E-50B 26 51 TSH + 0.53" Single Axial Indication (SAI) Sludge pile ODSCC E-50B 20 53 TSH + 0.12" Single Axial Indication (SAI) Sludge pile ODSCC E-50B 3
54 TSH - 9.93" Single Axial Indication (SAI) PWSCC E-50B 115 62 TSH + 0.06" Single Circumferential Indication (SCI) ODSCC E-50B 67 100 01 H + 0.08" Single Axial Indication (SAI) Dent ODSCC E-50B 23 102 VS4 + 0.62" Single Axial Indication (SAI) Dent ODSCC E-50B 57 108 TSH + 0.07" Single Circumferential Indication (SCI) ODSCC E-50B 20 111 TSH - 0.43" Single Circumferential Indication (SCI) ODSCC E-50B 48 113 TSH + 0.72" Single Axial Indication (SAI) Sludge pile ODSCC Tube Pulls and In-Situ Pressure Testing No tubes were pulled in either SG. No tubes with identified indications in either SG required in-situ pressure testing.
71
Table 7A Steam Generator Support Structure Nomenclature Name Description Name Description TEH Tube End - Hot Side VS4 Fourth Vertical Strap TSH Top of Tubesheet - Hot Side VS5 Fifth Vertical Strap 01 H First Eggcrate - Hot Side VS6 Sixth Vertical Strap 02H Second Eggcrate - Hot Side VS7 Seventh Vertical Strap 03H Third Eggcrate - Hot Side DBC Diagonal Strap - Cold Side 04H Fourth Eggcrate - Hot Side 08C Eighth Eggcrate - Cold Side 05H Fifth Eggcrate - Hot Side 07C 1 Seventh Eggcrate - Cold Side 06H Sixth Eggcrate - Hot Side 06C
'Sixth Eggcrate - Cold Side 07H Seventh Eggcrate - Hot Side 05C Fifth Eggcrate - Cold Side 08H Eighth Eggcrate - Hot Side 04C Fourth Eggcrate -Cold Side DBH Diagonal Strap - Hot Side 03C Third Eggcrate - Cold Side VS1 1 First Vertical Strap 02C Second Eggcrate - Cold Side VS2
! Second Vertical Strap 01C First Eggcrate - Cold Side VS3 Third Vertical Strap TSC Top of Tubesheet - Cold Side TEC Tube End - Cold Side Table 7B Acronyms and Abbreviations Acronym Definition DNI Dent or Ding with Indication DSI Distorted Support Indication MRPC Motorized Rotating Pancake Coil (+Pt.TM)
MBM Manufacturing Burnish Mark NDE Non Destructive Examination NQI Non-Quantifiable Indication NTE No Tube Expansion ODSCC Outside Diameter Stress Corrosion Cracking PAP Possible Loose Part PVN Permeability Variation PWSCC Primary Water Stress Corrosion Cracking SAI Single Axial Indication SCI Single Circumferential Indication SVI Single Volumetric Indication TBP To Be Plugged TTS Top of Tubesheet
<TS Less Than Technical Specification WAR Wear Indication 72