SONGS UNIT 2 SINGLE-SIDED Operating License & Technical Specification/Licensee Controlled Specification Unit 2 TS Amend. 213, B08-001 and B08-002 Unit 2 LCS L08-001 and L08-002 PCN 556 Supp. 2 Revise Unit 2 Operating License by removing pages and inserting the enclosed pages.

The revised pages are identified by the captioned amendment number and/or dates and contain marginal/lines indicating the areas of change. Please direct any questions regarding filing of information to: (949) 368-6972 or email CDM Controlled Manuals Desk.

REMOVE: INSERT:

VOLUME 1 VOLUME 1 BEHIND: List of Effective Pages-"Blue Tab" BEHIND: List of Effective Pages-"Blue Tab" List of Effective Pages Pages 1-12 List of Effective Pages Pages 1-12 Rev. 0 Amd. 215 12/12/07 Rev. 1 Amd. 215 03/05/08 BEHIND: "Blue Tab" 3.7 Plant Systems BEHIND: "Blue Tab" 3.7 Plant Systems Page 3.7-30 Amd. 127 Page 3.7-30 Amd. 213 Page 3.7-32 Amd. 131 Page 3.7-32 Amd. 213 Page 3.7-33 Amd. 131 Page 3.7-33 Amd. 213 Page 3.7-34 Amd. 131 Page 3.7-34 Amd. 213 Nothing to Pull Page 3.7-34a Amd. 213 (new page)

Nothing to Pull Page 3.7-34b Amd. 213 (new page)

BEHIND: "Blue Tab" 4.0 Design Features BEHIND: "Blue Tab" 4.0 Design Features Page 4.0-4 Amd. 131 Page 4.0-4 Amd. 213 Nothing to Pull Page 4.0-4a Amd. 213 (new page)

VOLUME 3 VOLUME 3 BEHIND: "Blue Tab" B 3.4-75a B 3.4 Amd. 127 09/24/98 BEHIND: "Blue Tab" B1 3.4 (deleting page) 4 BEHIND: : "Blue Tab" B 3.7 BEHIND: "Blue Tab" B 3.7 Page B 3.7-71 Amd. 127 04/29/03 Page B 3.7-71 Amd. 127 03/05/08 Page B 3.7-72 Amd. 127 Page B 3.7-72 Amd, 127 03/05/08 Page B 3.7-73 Amd. 127 Page B 3.7-73 Amd. 127 03/05/08 Page B 3.7-74 Amd. 127 04/29/03 Page B 3.7-74 Amd. 127 03/05/08 Page B 3.7-75 Amd. 127 04/29/03 Page B 3.7-75 Amd. 127 03/05/08 Nothing to Pull Page B 3.7-75a Amd. 127 03/05/08 (new page)

Page 1 of 3 Ao&i

SONGS UNIT 2 SINGLE-SIDED Operating License & Technical Specification/Licensee Controlled Specification Unit 2 TS Amend. 213, B08-001 and B08-002 Unit 2 LCS L08-001 and L08-002 PCN 556 Supp. 2 Revise Unit 2 Operating License by removing pages and inserting the enclosed pages.

The revised pages are identified by the captioned amendment number and/or dates and contain marginal/lines indicating the areas of change. Please direct any questions regarding filing of information to: (949) 368-6972 or email CDM Controlled Manuals Desk.

REMOVE: INSERT:

VOLUME 3 VOLUME 3 BEHIND: "Blue Tab" B 3.8 BEHIND: "Blue Tab" B 3.8 Page B 3.8-83 Amd. 127 01/11/07 Page B 3.8-83 Amd. 127 03/05/08 LCS BOOK LCS BOOK BEHIND: "White Tab" List of Effective Pages BEHIND: "White Tab" List of Effective Pages Pages 1 - 5 Rev. 0 12/12/07 Pages 1 - 6 Rev. 1 03/05/08 BEHIND: "Blue Tab" 3.7 Plant Systems BEHIND: "Blue Tab" 3.7 Plant Systems Page 3.7.116-1 Rev. 3 03/26/01 Page 3.7.116-1 Rev. 4 03/05/08 Paae 3.7.116-2 Rev.2 03/26/01 I4 Paae 3.7.116-2 Rev. 3 03/05/08 BEHIND: "Blue Tab" 4.0 Design Features BEHIND: "Blue Tab" 4.0 Design Features Page 4.0-100-1 Rev. 1 12/01/97 Page 4.0-100-1 Rev. 2 09/27/07 Page 4.0-100-2 Rev. 1 12/01/97 Page 4.0-100-2 Rev. 2 09/27/07 Page 4.0-100-3 Rev. 1 12/01/97 Page 4.0-100-3 Rev. 2 09/27/07 Nothing to Pull 4.0-100-4 through 4.0-100-63 (new pages) Rev. 2 09/27/07 Page 2 of 3

SONGS UNIT 2 SINGLE-SIDED Operating License & Technical Specification/Licensee Controlled Specification Unit 2 TS Amend. 213, B08-001 and B08-002 Unit 2 LCS L08-001 and L08-002 PCN 556 Supp. 2 Revise Unit 2 Operating License by removing pages and inserting the enclosed pages.

The revised pages are identified by the captioned amendment number and/or dates and contain marginal/lines indicating the areas of change. Please direct any questions regarding filing of information to: (949) 368-6972 or email CDM Controlled Manuals Desk.

Filing Instructions Reviewed & Approved:

De / ne Signatu're/NRA Date

.3(9 C~

Signature/CDM Processor J Date

/

Page 3 of 3

APPENDIX A TO LICENSE NO. NPF-1O SAN ONOFRE UNIT 2 TECHNICAL SPECIFICATIONS (NUREG-0741)

LIST OF EFFECTIVE PAGES Page No. Volume Amendment/Date Page No. Volume Amendment/Date LOEP-i 215 03/05/08 2.0-1 207 LOEP-2 208 01/25/07 2.0-2 207 LOEP-3 214 3.0-1 127 LOEP-44 215 3.0-2ý 127 LOEP-4a 168 3.0-3 127 LOEP-5 207 12/21/06 3.0-4 186 LOEP-6 200 11/18/05 3.0-5 127 LOEP-7 197 07/19/05 3.1-1 200 LOEP-8 208 12/05/06 3.1-2 200 LOEP-9 204 09/19/06 3.1-3 200 LOEP-1O 212 12/12/07 3.1-4 127 LOEP-11 211 03/05/08 3.1-5 127 LOEP-12 193 03/05/08 3.1-6 127 ii 127 3. 1-7 200 iii 208 3.1-8 200 iv 208 3.1-9 127 v 197 3.1-10 127 vi 127 3.1-11 127 vii 208 3.1-12 200 viii 208 3 1-13 127 1 .1- 127 3.1-14 200 1.1-2 127 3.1-15 200 1.1-3 188 3.1-16 200 1.1-4 204 3.1-17 127 1.1-5 203. 3.1-18 127 1.1-6 200 3.1-19 127 1.1-7 127 3.1-20 127 1.2-1 127 3.1-21 163 1.2-2 127 3.1-22 175 1.2-3 127 3.1-23 127 1.3-1 127 3.1-24 127 1.3-2 127 3.1-25 127 1.3-3 127 3.1-26 127 1.3-4 127 3.1-27 127 1.3-5 127 3.1-28 127 1.3-6 127 3.1-29 127 1.3-7 127 3.2-1 127 1.3-8 127 3.2-2 127 1.3-9 127 3.2-3 127 1.3-10 127 3.2-4 127 1.3-11 127 3.2-5 127 1.3-12 127 3.2-6 127 1.3-13 127 3.2-7 127 1.4-1 127 3.2-8 127 1.4-2 127 3.2-9 200 1.4-3 127 3.2-10 127 1.4-4 127 3.2-11 127 3.2-12 127 NDMS Revision 1 Page 1 of 12 Amendment 215 03/05/08

APPENDIX A TO LICENSE NO. NPF-1O SAN ONOFRE UNIT 2 TECHNICAL SPECIFICATIONS (NUREG-0741)

LIST OF EFFECTIVE PAGES Page No. Volume Amendment/Date Page No. Volume Amendment/Date 3.3-1 127 3.3-50 127 3.3-2 127 3.3-51 175 3.3-3 127 3.3-52 127 3.3-4 127 3.4-1 149 3.3-5 127 3.4-2 149 3.3-6 147 3.4-3 149 3.3-7 133 3.4-4 127 3.3-8 150 3.4-5 203 3.3-9 150 3.4-6 203 3.3-10 127 3.4-7 203 3.3-11 127 3.4-8 203 3.3-12 133 3.4-9 203 3.3-13 147 3.4-10 203 3.3-14 127 3.4-11 203 3.3-15 127 3.4-12 203 3.3-16 133 3.4-13 127 3.3-17 127 3.4-14 197 3.3-18 127 3.4-15 127 3.3-19 127 3.4-16 175 3.3-20 133 3.4-17 175 3.3-21 127 3.4-18 203 3.3-22 157 3.4-19 175 3.3-23 157 3.4-20 127 3.3-24 157 3.4-21 175 3.3-25 157 3.4-22 203 3.3-26 127 3.4-23 175 3.3-27 127 3.4-24 175 3.3-28 127 3.4-25 175 3.3-29 133 3.4-26 161 3.3-30 127 3.4-27 155 3.3-31 127 3.4-28 156 3.3-32 127 3.4-29 156 3.3-33 127 3.4-30 203 3.3-34 196 3.4-31 203 3.3-35 132 3.4-32 127

,3.3-36 132 3.4-33 203 3.3-37 132 3.4-34 143 3.3-38 132 3.4-35 203 3.3-39 132 3.4-36 127 3.3-40 175 3.4-37 204 3.3-41 160 3.4-38 204 3.3-42 208 01/25/07 3.4-39 127 3.3-43 208 01/25/07 3.4-40 127 3.3-44 127 3.4-41 127 3.3-45 194 3.4-42 127 3.3-46 194 3.4-43 127 3.3-47 194 3.4-44 127 3.3-48 127 3.4-45 127 3.-3-.49 127 NDMS Revision 1 Page 2 of 12 Amendment 208 01/25/07

APPENDIX A TO LICENSE NO. NPF-1O SAN ONOFRE UNIT 2 TECHNICAL SPECIFICATIONS (NUREG-0741)

LIST OF EFFECTIVE PAGES Page No. Volume Amendment/Date Page No. Volume Amendment/Date 3.4-46 127 3.7-6 127 3.4-47 127 3.7-7 127 3.4-48 127 3.7-8 127 3..4-49 127 3.7-9 127 3.4-50 127 3.7-10 127 3.4-51 204 3.7-11 164 3.4-52 204 3.7-12 127 3.5-1 139 3.7-13 127 3.5-2 135 3.7-14 191 3.5-3 127 3.7-15 147 3.5-4 139 3.7-16 162 3.5-5 127 3.7-17 127 3 .5- 6 190 3.7-18 127 3.5-7 127 3.7-19 127 3.5-8 127 3.7-19a 129 3.5-9 127 3.7-19b 129 3.5-10 127 3.7-19c 129 3.5-11 127 3.7-20 127 3.6-1 127 3.7-21 127 3.6-2 144 3.7-22 181 3.6-3 127 3.7-23 127 3.6-4 127 3.7-24 214 3.6-5 127 3.7-25 214 3.6-6 144 3.7-26 214 3.6-7 127 3.7-27 208 01/25/07 3.6-8 127 3.7-28 208 01/25/07 3.6-9 127 3.7-29 127 3.6-10 127 3.7-30 213 3.6-11 127 3.7-31 127 3.6-12 165 3.7-32 213 3.6-13 201 3.7-33 213 3.6-14 201 3.7-34 213 3.6-15 127 3.7-34a 213 3.6-16 127 3.7-34b 213 3.6-17 127 3.7-35 127 3.6-18 171 3.8-1 141 3.6-19 127 3.8-2 141 3.6-20 127 3.8-3 127 3.6-21 127 3.8-4 127 3.6-22 127 3.8-5 179 3.6-23 159 3.8-6 211 3.6-24 159 3.8-7 158 3.6-25 127 3.8-8 179 3.6-26 127 3.8-9 158 3.7-1 212 3.8-10 158 3.7-2 127 3.8-11 158 3.7-3 212 3.8-12 158 3.7-4 212 3.8-13 169 3.7-5 127 3.8-14 179 NDMS Revision 1 Page 3 of 12 Amendment 214

APPENDIX A TO LICENSE NO. NPF-1O SAN ONOFRE UNIT 2 TECHNICAL SPECIFICATIONS (NUREG-0741)

LIST OF EFFECTIVE PAGES Page No. Volume Amendment/Date Page No. Volume Amendment/Date 3.8-15 158 5.0-5 207 3.8-16 127 5.0-6 184 3.8-17 127 5.0-7 127 3.8-18 175 5.0-8 207 3.8-19 127 5.0-9 178 3.8-20 211 5.0-10 127 3.8-21 211 5.0-11 170 3.8-22 127 5.0-12 178 3.8-23 127 5.0-13 204 3.8-24 127 5.0-14 204 3.8-25 127 5.0-15 206 3.8-26 127 5 .0-15a 215 3.8-27 175 5.0-16 215 3.8-28 127 5.0-17 208 3.8-29 127 5.0-18 204 3.8-30 127 5.0-19 204 3.8-31 127 5.0-20 204 3.8-32 127 5.0-20a 198 3.8-33 127 5.0-20b 214 3.8-34 127 5.0-20c 214 3.8-35 127 5.0-21 127 3.8-36 175 5.0-22 127 3.8-37 127 5.0-23 195 3.8-38 127 5.0-24 127 3.8-39 127 5.0-25 127 3.8-40 175 5.0-26 200 3.8-41 127 5.0-27 203 3.9-1 127 5.0-27a 203 3.9-2 175 5.0-28 204 3.9-3 127 5.0-29 204 3.9-4 193 5.0-30 197 3.9-5 127 5.0-31 207 3.9-6 175 3.9-6a 175 3.9-7 153 3.9-8 153 3.9-9 175 3.9-9a 153 3.9-10 134 4.0-1 199 4.0-2 127 4.0-3 127 4.0-4 213 4.O-4a 213 4.0-5 131 5.0-1 207 5.0-2 .207 5.0-3 207 5.0-4 207 NDMS Revision I Page 4 of 12 Amendment 215

APPENDIX A TO LICENSE NO. NPF-IO SAN ONOFRE UNIT 2 TECHNICAL SPECIFICATIONS (NUREG-0741)

LIST OF EFFECTIVE PAGES Page No. Vol ume Amendment/Date Bibliographic Data Sheet dated February 17, 1982 Appendix B dated February 17, 1982 Unit 2 Environmental Protection Plan dated February 17, 1982 I-1 dated February 17, 1982 2-1 dated February 17, 1982 2-2 dated February 17, 1982 3-I dated February 17, 1982 3-2 168 4-1 168 4-2 dated February 17, 1982 Appendix C Anti Trust Conditions Appendix C dated February 17, 1982 2 dated February 17, 1982 3 dated February 17, 1982 NDMS Revision 1 Page 4a of 12 Amendment 168

APPENDIX A TO LICENSE NO. NPF-1O SAN ONOFRE UNIT 2 TECHNICAL SPECIFICATIONS (NUREG-0741)

LIST OF EFFECTIVE PAGES Page No. Volume Amendment/Date Page No. Volume Amendment/Date 2.0-1 192 07/19/04 3.1-27 127 2.0-2 127 3.1-28 200 11/18/05 2.0-3 .207 12/21/06 3.1-29 200 11/18/05 2.0-3a 192 07/19/04 3.1-30 200 11/18/05 2.0-4 207 12/21/06 3.1-31 127 2.0-5 207 12/21/06 3.1-32 127 05/02/97 2.0-6 127 3.1-33 127 2.0-7 127 3.1-34 127 05/02/97 2.0-8 207 12/21/06 3.1-35 127 2.0-9 207 12/21/06 3.1-36 127 3.0-1 127 3.1-37 200 11/18/05 3.0-2 127 3.1-38 200 11/18/05 3.0-3 127 3.1-39 127 3.0-4 207 12/21/06 3.1-40 127 3.0-5 127 3.1-41 127 3.0-6 127 3.1-42 127 3.0-7 127 3.1-43 200 11/18/05 3.0-8 127 3.1-43a 200 11/18/05 3.0-9 127 3.1-44 200 11/18/05 3.0-10 127 3.1-45 127 3.0-11 127 3.1-46 200 11/18/05 3.0-12 127 12/01/98 3.1-47 127 3.0-13 186 10/25/02 3.1-48 127 3.0-14 186 05/08/02 3.1-49 127 3.0-15 186 05/08/02 3.1-50 127 3.1-1 200 11/18/05 3.1-51 127 3.1-2 200 11/18/05 3.1-52 127 3.1-3 200 11/18/05 3.1-53 127 3.1-4 200 11/18/05 3.1-54 127 08/03/01 3.1-5 200 11/18/05 3.1-55 127 08/03/01 3.1-6 200 11/18/05 3.1-56 127 08/03/01 3.1-7 200 11/18/05 3.1-57 127 08/03/01 3.1-8 200 11/18/05 3.1-58 127 08/03/01 3.1-9 200 11/18/05 3.1-58a 127 08/03/01 3.1-10 200 11/18/05 3.1-58b 127 08/03/01 3.1-11 200 11/18/05 3.1-59 200 11/18/05 3.1-12 200 11/18/05 3.1-60 127 11/05/96 3.1-13 127 3.1-61 127 05/03/00 3.1-14 127 3.1-62 175 12/20100 3.1-15 200 11/18/05 3.1-63 175 05/21/02 3.1-16 127 3.1-63a 175 12/20/00 3.1-17 200 11/18/05 3.1-64 127 3.1-18 127 3.1-65 127 3.1-19 127 01/03/02 3.1-66 127 3.1-20 127 3.1-67 127 3.1-21 127 01/03/02 3.1-68 127 3.1-22 127 05/30/97 3.1-69 127 3.1-23 127 3.1-70 127 3.1-24 127 3.1-71 127 3.1-25 127 05/02/97 3.1-72 127 3.1-26 127 07/29/99 NDMS Revision I Page 5 of 12 Amendment 207 12/21/06

APPENDIX A TO LICENSE NO. NPF-1O SAN ONOFRE UNIT 2 TECHNICAL SPECIFICATIONS (NUREG-0741)

LIST OF EFFECTIVE PAGES Page No. Volume Amendment/Date Page No. Volume Amendment/Date 3 .1-73 127 3.3-2 2 127 07/17/97 3.1-74 127 3.3-3 2 127 3.1-75 127 3.3-4 2 127 3.1-76 127 3.3-5 2 127 3.1-77 127 05/29/97 3.3-6 2 127 3.1-78 127 05/29/97 3.3-7 2 127 3.1-79 127 3.3-8 2 127 3.1-80 127 3.3-9 2 .127 3.2-1 127 3.3-10 2 127 3.2-2 127 3.3-11 2 127 3.2-3 127 3.3-12 2 127 03/12/99 3.2-4 192 07/19/04 3.3-13 2 127 3.2-5 127 3.3-14 2 127 3.2-6 127 3.3-15 2 127 3.2-7 127 3.3-16 2 127 07/17/97 3.2-8 127 3.3-17 2 127 09/16/03 3.2-9 127 3.3-18 2 127 03/12/99 3.2-10 127 3.3-19 2 127 3.2-11 127 3.3-20 2 127 3.2-12 192 07/19/04 3.3-21 2 127 .03/12/99 3.2-13 127 3.3-22 2 127 03/12/99 3.2-14 127 3.3-23 2 127 03/12/99 3.2-15 127 3.3-24 2 127 3.2-16 127 3.3-25 2 127 12/30/96 3.2-17 127 3.3-26 2 127 12/30/96 3.2-18 127 3.3-26a 2 127 12/30/96 3.2-19 192 07/19/04 3.3-27 2 127 3.2-20 127 3.3-28 2 127 3.2-21 127 3.3-29 2 127 3.2-22 127 3.3-30 2 127 05/29/97 3.2-23 127 3.3-31 2 127 05/02/97 3.2-24 127 3.3-32 2 127 03/12/99 3.2-25 127 3.3-33 2 127 03/12/99 3.2-26 127 3.3-34 2 127 03/12/99 3.2-27 127 3.3-35 2 127 03/12/99 3.2-28 127 3.3-36 2 127 03/12/99 3.2-29 192 07/19/04 3.3-37 2 188 3.2-30 200 11/18/05 3.3-37a 2 188 09/16/03 3.2-31 127 3.3-38 2 127 3.2-32 127 3.3-39 2 127 07/17/97 3.2-33 127 3.3-40 2 127 09/25/98 3.2-34 127 3.3-41 2 127 09/25/98 3'2-35 127 3.3-42 2 127 3.2-36 127 3.3-43 2 127 3.2-37 127 3.3-44 2 127 12/30/96 3.2-38 192 07/19/04 3.3-45 2 127 12/30/96 3.2-39 127 3.3-46 2 127 12/30/96 3.2-40 127 3.3-47 2 127 12/30/96 3.2-41 127 3.3-48 2 127 09/18/98 3.3-1 127 3.3-49 2 .127 09/18/98 NDMS Revision I Page 6 of 12 Amendment 200 11/18/05

APPENDIX A TO LICENSE NO. NPF-1O SAN ONOFRE UNIT 2 TECHNICAL SPECIFICATIONS (NUREG-0741)

LIST OF EFFECTIVE PAGES Page No. Volume Amendment/Date Page No. Volume Amendment/Date 3.3-50 127 09/18/98 3.3-100 197 07/19/05 3.3-51 127 02/11/02 3.3-101 127 10/06/99 3.3-52 127 3.3-102 127 10/06/99 3.3-53 127 07/17/97 3.3-103 127 10/06/99 3.3-54 127 3.3-103a 188 3.3-55 127 3.3-103b 157 09/16/03 3.3-56 127 3.3-103c 188 3.3-57 127 3.3-104 127 3.3-58 127 3.3-105 127 3.3-59 127 3.3-106 127 3.3-60 127 .09/18/98 3.3-107 127 3.3-61 127 09/18/98 3.3-108 127 3.3-62 127 09/18/98 3.3-109 127 3.3-63 127 3.3-110 127 3.3-64 127 07/17/97 3.3-111 127 3.3-65 127 3.3-112 127 3.3-66 127 3.3-113 127 3.3-67 127 3.3-114 127 3.3-68 127 3.3-115 127 3.3-69 127 3.3-116 127 3.3-70 127 3.3-117 127 3.3-71 127 3.3-118 127 3.3-72 127 12/30/96 3.3-119 127 12/30/996 3.3-73 127 12/30/96 3.3-120 127 12/30/96 3.3-74 127 12/30/96 3.3-121 127 12/30/96 3.3-75 127 05/28/97 3.3-122 127 12/30/96 3.3-76 127 12/30/96 3.3-123 127 05/28/97 3.3-77 127 07/17/97 3.3-124 127 05/28/97 3.3-78 127 3.3-125 127 05/28/97 3.3-79 127 3.3-126 127 3.3-80 127 3.3-127 127 3.3-81 127 3.3-128 127 3.3-82 127 3.3-129 127 09/06/00 3.3-83 127 3.3-130 127 3.3-84 127 3.3-131 127 09/06/00 3.3-85 127 3.3-132 127 05/29/97 3.3-86 127 3.3-133 127 07/13/99 3.3-87 127 02/24/99 3.3-134 174 12/14/00 3.3-88 127 07/17/97 3.3-135 127 05/28/97 3.3-89 127 3.3-136 127 06/09/00 3.3-90 127 3.3-137 127 05/28/97 3.3-91 127 3 3-138 127 05/28/97 3.3-92 127 3.3-139 127 05/28/97 3.3-93 127 3.3-140 127 05/28/97 3.3-94 127 3.3-141 127 05/28/97

.3.3-95 127 10/06/99 3.3-142 127 05/28/97 3.3-96 127 10/06/99 3.3-143 127 05/28/97 3.3-97 127 10/06/99 3.3-144 127 05/28/97 3.3-98 127 07/18/01 3.3-145 127 06/27/97 3.3-99 127 10/06/99 3.3-146 127 03/19/98 NDMS Revision 1 Page 7 of 12 Amendment 197 07/19/05

APPENDIX A TO LICENSE NO. NPF-1O SAN ONOFRE UNIT2 TECHNICAL SPECIFICATIONS (NUREG-0741)

LIST OF EFFECTIVE PAGES Page No. Volume Amendment/Date Page No. Volume Amendment/Date 3.3-147 127 06/27/97 3.4-12 127 3.3-148 175 12/20/00 3.4-13 127 3.3-149 175 12/20/00 3.4-14 127 3.3-150 127 08/20/01 3.4-15 203 3.3-151 127 06/27/97 3.4-16 203 3.3-152 208 12/05/06 3.4-17 197 07/19/05 3.3-153 208 12/05/06 3.4-18 197 07/.19/05 3.3-154 208 12/05/06 3.4-19 127 3.3-155 208 12/05/06 3.4-20 197 07/19/05 3.3-156 208 12/05/06 3.4-21 197 07/19/05 3.3-157 208 12/05/06 3.4-22 127 3.3-158 127 12/17/98 3.4-23 127 3.3-159 127 06/08/00 3.4-24 204 3.3-160 127 06/23/99 3.4-25 127 3.3-161 127 05/30/97 3.4-26 127 3.3-162 127 05/30/97 3.4-27 127 3.3-163 130 05/30/97 3.4-28 204 3.3-164 127 05/30/97 3.4-29 175 12/20/00 3.3-165 127 05/30/97 3.4-30 175 12/20/00 3.3-166 194 04/25/05 3.4-31 127 3.3-167 127 05/30/97 3.4-32 204 3.3-168 127 12/02/99 3.4-33 127 3.3-169 127 05/30/97 3.4-34 175 12/20/00 3.3-170 127 3.4-35 175 12/20/00 3.3-171 194 04/25/05 3.4-36 127 3.3-172 194 04/25/05 3.4-37 175 12/20/00 3.3-173 127 05/30/97 3.4-38 175 07/15/05 3.3-174 127 05/30/97 3.4-38a 175 04/03/06 3.3-175 127 03/06/06 3.4-39 204 3.3-176 127 10/30/98 3.4-40 175 12/20/00 3.3-177 127 10/30/98 3.4-41 127 3.3-178 127 3.4-42 127 3.3-179 127 04/24/01 3.4-43 175 12/20/00 3.3-180 127 04/24/01 3.4-44 175 04/03/06 3.3-181 127 07/29/96 3.4-45 175 12/2 0/00 3.3-182 175 12/20/00 3.4-46 127 05/30/00 3.3-183 175 12/20/00 3.4-47 155 05/30/00 3.3-184 175 12/20/00 3.4-48 161 05/15/02 3.3-185 175 12/20/00 3.4-49 127 05/30/00 3.4-1 127 02/24/99 3.4-50 127 05/30/00 3.4-2 127 02/24/99 3.4-51 156 03/22/01 3.4-3 127 3.4-52 156 03/22/01 3.4-4 127 3.4-53 3 156 03/22/01 3.4-5 127 02/24/99 3.4-54 3 156 04/27/05 3.4-6 127 3.4-55 3 203

.3.4-7 127 3.4-56 3 203 3.4-8 127 3.4-57 3 203 3.4-9 203 3*4-58 3 203 3.4-10 127 3.4-59 3 203 3.4-11 127 3.4-60 3 203 NDMS Revision 1 Page 8 of 12 Amendment 208 12/05/06

APPENDIX A TO LICENSE NO. NPF-1O SAN ONOFRE UNIT 2 TECHNICAL SPECIFICATIONS (NUREG-0741)

LIST OF EFFECTIVE PAGES Page No. Volume Amendment/Date Page No. Volume Amendment/Date 3.4-61 203 B 3.5-11 127 03/03/00 3.4-62 203 B 3.5-12 127 03/03/00 3.4-63 203 B 3.5-13 127 03/03/00 3.4-64 203 B 3.5-14 127 03/03/00 3.4-65 203 B 3.5-15 127 03/03/00 3.4-66 203 B 3.5-16 197 07/19/05 3.4-67 203 B 3.5-17 127 03/03/00 3.4-68 203 B 3.5-18 127 03/14/02 3.4-69 203 B 3.5-19 127 03/14/02 3.4-70 127 B 3.5-20 127 07/17/01 3.4-71 204 B 3.5-20a 127 03/03/00 3.4-72 204 B 3.5-21 127 3.4-73 204 B 3.5-22 127 3.4-74 204 B 3.5-23 127 3.4-75 204 B 3.5-24 127 3.4-76 127 B 3.5-25 127 3.4-77 127 B 3.5-26 127 3.4-78 127 B 3.5-27 127 3.4-79 127 B 3.5-28 127 3.4-80 127 09/06/00 B 3.5-29 127 3.4-81 127 09/06/00 B 3.5-30 127 3.4-82 127 B 3.5-31 127 3.4-83 127 B 3.5-32 127 3.4-84 127 B 3.5-33 127 3.4-85 127 B 3.5-34 127 3.4-86 127 B 3.6-1 127 12/01/98 3.4-87 127 B 3.6-2 182 04/29/03 3.4-88 127 05/13/02 B 3.6-3 127 12/01/98 3.4-89 127 05/13/02 B 3.6-4 127 04/29/03 3.4-90 127 B 3.6-5 127 12/01/98 3.4-91 127 B 3.6-6 182 02/11/02 3.4-92 127 B 3.6-7 127 3.4-93 204 B 3.6-8 127 3.4-94 204 B 3.6-9 127 3.4-95 204 B 3.6-10 127 3.4-96 204 B 3.6-11 127 12/01/98 3.4-97 204 B 3.6-12 127 04/29/03 3.4-98 204 B 3.6-13 127 07/29/99 3.4-99 204 B 3.6-14 127 3.4-100 204 B 3.6-15 127 3.5-1 127 B 3.6-16 127 04/29/03 3.5-2 127 B 3.6-17 127 3.5-3 127 B 3.6-18 127 06/09/00 3.5-4 127 05/05/03 B 3.6-19 127 3.5-5 127 05/30/97 B 3.6-20 127 3.5-6 127 B 3.6-21 127 04/29/03 3.5-7 127 07/15/98 B 3.6-22 127 10/24/01 3.5-8 197 07/19/05 B 3.6-23 201 12/12/05 3.5-9 127 07/15/98 B 3.6-24 201 12/12/05 3.5-10 127 07/15/98 B 3.6-24a 201 12/12/05 3.5-10a 197 07/19/05 B 3.6-25 127 04/29/03 NDMS Revision 1 Page 9 of 12 Amendment 204 09/19/06

APPENDIX A TO LICENSE NO. NPF-1O SAN ONOFRE UNIT 2 TECHNICAL SPECIFICATIONS (NUREG-0741)

LIST OF EFFECTIVE PAGES Page No. Volume Amendment/Date Page No. Volume Amendment/Date 3.6-26 127 04/29/03 3.7-20 1.27 06/02/04 3.6-27 182 07/11/02 3.7-21 127 06/02/04 3.6-28 182 02/11/02 3.7-22 127 06/02/04 3.6-29 127 3.7-23 127 07/29/99 3.6-30 127 04/29/03 3.7-24 127 12/14/00 3.6-31 182 05/02/02 3.7-25 127 3.6-32 127 3.7-26 127 02/28/01 3.6-33 127 3.7-27 127 02/28/01 3.6-34 127 3.7-28 127 03/03/00 3.6-35 182 02/11/02 3.7-29 127 03/03/00 3.6-36 182 02/11/02 3.7-30 127 03/03/00 3.6-37 197 07/19/05 3.7-31 191 11/25/03 3.6-38 197 07/19/05 3.7-32 191 11/25/03 3.6-39 127 10/06/00 3.7-33 191 11/25/03 3.6-40 127 10/06/00 3.7-34 127 03/03/00 3.6-41 127 10/06/00 3.7-35 127 07/31/00 3.6-42 127 04/29/03 3.7-36 127 07,/31/00 3.6-43 127 3.7-37 127 08/13/01 3.6-44 127 3.7-38 127 08/01/01 3.6-45 127 3.7-39 127 06/23/99 3.6-46 127 3.7-40 127 3.6-47 127 3.7=41 127 04/03/06 3.6-48 159 10/29/99 3.7-42 127 3.6-49 159 10/29/99 3.7-43 127 3.6-50 159 10/29/99 3.7-43a 127 05/29/97 3.6-51 159 10/29/99 3.7-43b 127 3.6-52 159 10/29/99 3.7-43c 129 3.6-53 159 10/06/00 3.7-43d 129 08/09/96 3.6-54 159 10/06/00 3.7-43e 129 3.6-55 159 10/29/99 3.7-43f 129 3.6-56 159 10/29/99 3.7-43g 129 3.6-57 159 10/29/99 3.7-43h 129 3.7-1 212 06/21/07 3.7-43i 129 3.7-2 127 08/18/98 3.7-43j 129 3.7-3 212 06/21/07 3.7-44 127 3.7-4 212 06/21/07 3.7-45 127 3.7-5 212 06/21/07 3.7-46 127 3.7-6 212 06/21/07 3.7-47 127 05/30/97 3.7-7 127 04/16/99 3.7-48 127 3.7-8 127 06/23/99 3.7-49 127 10/17/01 3.7-9 127 3.7-50 197 03/07/07 3.7-10 127 3.7-50a 197 03/07/07 3.7-11 127 3.7-51 127 04 /08/07 3.7-12 127 3.7-52 127 10/17/ 01 3.7-13 127 3.7-53 127 04/12/01 3.7-14 127 04/16/99 3.7-54 127 04/12/01 3.7-15 127 3.7-55 127 03/07/07 3.7-16 127 3.7-55a 127 03/07/07 3.7-17 127 06/02/04 3.7-56 127 12/12/07 3.7-18 127 3.7-57 127 12/12/07 3.7-19 127 3.7-58 127 12/12/07 NDMS Revision I Page 10 of 12 Amendment 212 12/12/07

APPENDIX A TO LICENSE NO. NPF-10 SAN ONOFRE UNIT 2 TECHNICAL SPECIFICATIONS (NUREG-O741)

LIST OF EFFECTIVE PAGES Pagqe No. Volume Amendment/Date Page No. Volume Amendment/Date 3.7-59 128 12/12/07 3.8-29 127 06/18/01 3.7-60 127 12/12/07 3.8-29a 169 06/18/01 3.7-61 128 12/12/07 3.8-29b 169 06/18/01 3.7-62 128 12/12/07 3.8-29c 169 06/.18/01 3.7-63 208 12/12/07 3.8-29d 169 06/18/01 3.7-64 208 12/12/07 3.8-29e 169 06/18/01 3.7-65 208 12/12/07 3.8-29f 169 06/18/01 3.7-66 208 12/12/07 3.8-30 127 3.7-67 208 12/12/07 3.8-31 127 3.7-68 127 06/23/99 3.8-32 127 3.7-69 127 10/13/98 3.8-33 127 3.7-70 127 10/13/98 3.8-34 175 12/20/00 3.7-71 127 03/05/08 3.8-35 175 12/20/00 3.7-72 127 03/05/08 3.8-36 211 04/05/07 3.7-73 127 03/05/08 3.8-37 127 01/21/98 3.7-74 127 03/05/08 3.8-38 211 04/05/07 3.7-75 127 03/05/08 3.8-39 211 04/05/07 3.7-75a 127 03/05/08 3.8-40 127 01/21/98 3.7-76 127 05/13/02. 3.8-41 211 04/05/07 3.7-77 127 3.8-42 127 03/25/02 3.7-78 127 3.8-43 127 3.7-79 127 3.8-44 127 03/25/02 3.8-1 127 10/06/99 3.8-45 127 3.8-2 127 10/06 /99 3.8-46 127 05/03/00 3.8-3 127 10/06/99 3.8-47 127 01/22/99 3.8-4 127 10/06/99 3.8-47a 127 01/22/99 3.8-5 127 10/06/99 3.8-48 127 3.8-6 127 10/06/99 3.8-49 127 01/22/99 3.8-7 197 07/19/05 3.8-50 127 3.8-7a 127 12/10/ 99 3.8-51 127 3.8-8 127 10/06/99 3.8-52 127 3.8-9 127 11/29/07 3.8-53 127 01/22/99 3.8-10 197 07/19/05 3.8-54 127 08/05/98 3.8-11 127 10/06 /99 3.8-55 127 08/30/04 3.8-12 127 10/06 /99 3.8.55a 127 08/05/98 3.8-13 127 10/06/99 3.8-56 127 3.8-14 127 10/06/99 3.8-57 127 3.8-15 127 10/06/99 3.8-58 175 12/20/00 3.8-16 127 06/18/0 1 3.8-59 175 12/20/00 3.8-17 127 06/18/01 3.8-60 127 3.8-18 211 04/05/07 3.8-61 127 3.8-19 127 06/18/01 3.8-20 127 11/29/07 3.8-62 127 3.8-21 127 06/18/01 3.8-63 127 3.8-22 127 06/18/01 3.8-64 127 3.8-23 127 06/18/01 3.8-65 127 3.8-24 127 06/18/01 3.8-66 127 07/31/00 3.8-25 127 06/ 18/01 3.8-67 127 3.8-26 127 06/ 18/01 3.8-68 127 3.8-27 127 06/ 18/01 3.8-69 127 3.8-28 127 06/ 18/01 3.8-70 127 NDMS Revision 1 Page 11 of 12 Amendment 211 03/05/08

APPENDIX A TO LICENSE NO. NPF-1O SAN ONOFRE UNIT 2 TECHNICAL SPECIFICATIONS (NUREG-0741)

LIST OF EFFECTIVE PAGES Page No. Volume Amendment/Date Page No. Volume Amendment/Date 3 .8-71 127 3.8-72 127 3.8-73 175 12/20/00 3.8-74 175 12/20/00 3.8-75 127 3.8-76 127 3.8-77 127 3.8-78 127 3.8-79 127 3.8-80 127 3.8-81 127 3.8-82 127 3.8-83 127 03/05/08 3.8-84 127 3.8-85 127 12/20/00 3.8-86 175 3.8-87 175 12/20/00 3.9-1 127 3.9-2 127 3.9-3 1.75 12/20/00 3.9-4 127 3.9-5 127 3.9-6 175 12/20/00 3.9-7 127 3.9-8 127 3.9-9 127 12/01/98 3.9-10 193 02/ 18/05 3.9-11 127 10/10/97 3.9-12 127 10/10/97 3.9-13 193 02/18/05 3.9-13a 193 02/18/05 3.9-14 127 10/10/97 3.9-15 127 10/10/97 3.9-16 127 3.9-17 127 07/15/05 3 .9-17a 127 04/03/06 3.9-18 175 07/15/05 3.9-19 175 12/20/00 3.9-20 127 3.9-21 127 05/30/97 3.9-22 127 07/15/05 3.9-23 127 04/03/06 3.9-24 175 12/20/00 3.9-24a 175 12/20/00 3.9-25 127 05/30/97 3.9-26 127 10/13/98 3.9-27 127 10/13/98 NDMS Revision I Page 12 of 12 Amendment 193 03/05/08

Fuel Storage Pool Boron Concentration 3.7.17 3.7 PLANT SYSTEMS 3.7.17 Fuel Storage Pool Boron Concentration LCO 3.7.17 The fuel storage pool boron concentration shall be 2000 ppm.

APPLICABILITY: Whenever any fuel assembly is stored in the fuel storage pool.

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. Fuel storage pool ------------ NOTE----------

boron concentration LCO 3.0.3 is not applicable.

not within limit.

A.1 Suspend movement of Immediately fuel assemblies in the fuel storage pool.

AND A.2 Initiate action to Immediately restore fuel storage pool boron concentration to within limit.

SAN ONOFRE--UNIT 2 3.7-30 Amendment No. 213

Spent Fuel Assembly Storage 3.7.18 3.7 PLANT SYSTEMS 3.7.18 Spent Fuel Assembly Storage LCO 3.7.18 The combination of initial enrichment and burnup of each SONGS)2 and 3 spent fuel assembly stored in Region I shall be within the acceptable burnup domain of Figure 3.7.18-1 or Figure 3.7.18-2, or the fuel assembly shall be stored in accordance with Technical Specification 4.3.1.1.

The combination of initial enrichment and burnup of each SONGS 2 and 3 spent fuel assembly stored in Region II shall be within the acceptable burnup domain of Figure 3.7.18-3 or Figure 3.7.18-4, or the fuel assembly shall be stored in accordance with Technical Specification 4.3.1.1.

Each SONGS 1 uranium dioxide spent fuel assembly stored in Region II shall be stored in accordance with Technical Specification 4.3.1.1.

APPLICABILITY: Whenever any fuel assembly is stored in the fuel storage pool.

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. Requirements of the A.1 -------NOTE-------

LCO not met. LCO 3.0.3 is not applicable.

Initiate action to bring Immediately the noncomplying fuel assembly into compliance.

SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.7.18.1 Verify by administrative means the initial Prior to moving a enrichment, burnup, and cooling time of the fuel assembly to fuel assembly are in accordance with LCO any spent fuel 3.7.18, or Design Features 4.3.1.1, or LCS pool storage 4.0.100. Rev 2, dated 09/27/07. location.

SAN ONOFRE--UNIT 2 3.7-32 Amendment No. 213

Spent Fuel Assembly Storage 3.7.18 FIGURE 3.7.18-1 MINIMUM BURNUP AND COOLING TIME VS. INITIAL ENRICHMENT FOR UNRESTRICTED PLACEMENT OF SONGS 2 AND 3 FUEL IN REGION I RACKS 25 SlO-E LL 5 0

2.0 2.5 3.0 3.5 4.0 4.5 5.0 Initial U-235 Enrichment (w/o)

-8 OYears - 5Years -z 10Years-z- 15Years E 20 Years SAN ONOFRE--UNIT 2 3.7-33 Amendment No. 213

Spent Fuel Assembly Storage 3.7.18 FIGURE 3.7.18-2 MINIMUM BURNUP AND COOLING TIME VS. INITIAL ENRICHMENT FOR PLACEMENT OF SONGS 2 AND 3 FUEL IN PERIPHERAL POOL LOCATIONS IN REGION I RACKS 15 10 0.

E U) 5 (U

LL I!

0 3.0 3.5 4.0 4.5 5.0 Initial U-235 Enrichment (w/o)

OYears - 5 Years Zv- 10 Years 15 Years E 20 Years SAN ONOFRE--UNIT 2 3.7-34 Amendment No. 213

Spent Fuel Assembly Storage 3.7.18 FIGURE 3.7.18-3 MINIMUM BURNUP AND COOLING TIME VS. INITIAL ENRICHMENT FOR UNRESTRICTED PLACEMENT OF SONGS 2 AND 3 FUEL IN REGION II RACKS 1 2 3 4 5 Initial U-235 Enrichment (w/o)

Eý 0 Years -e-- 5 Years E 10 Years - 15 Years -E--- 20 Years SAN ONOFRE--UNIT 2 3.7-34a Amendment No. 213 1

Spent Fuel Assembly Storage 3.7.18 FIGURE 3.7.18-4 MINIMUM BURNUP AND COOLING TIME VS. INITIAL ENRICHMENT FOR PLACEMENT OF SONGS 2 AND 3 FUEL IN PERIPHERAL POOL LOCATIONS IN REGION II RACKS 0 30-E O20-E (I,

cn "10 II.

1.5 2 2.5 3 3.5 4 4.5 5 Initial U-235 Enrichment (w/o)

E OYears e 5 Years --- lOYears IF 15Years E 20Years SAN ONOFRE-UNIT 2 3.7-34b Amendment No. 213 1

Design Features 4.0 4.0 DESIGN FEATURES (continued) 4.3 Fuel Storage 4.3.1 Criticality 4.3.1.1 The spent fuel storage racks are designed and shall be maintained with:

a. Fuel assemblies having a maximum U-235 enrichment of 4.8 weight percent;
b. Keff * < 1.0 if fully flooded with unborated water, which includes an allowance for uncertainties as described in Section 9.1 of the UFSAR;
c. Keff
  • 0.95 if fully flooded with water borated to 1700 ppm, which includes an allowance for uncertainties as described in Section 9.1 of the UFSAR;
d. Three or five Borated stainless steel guide tube inserts (GT-Insert) may be used. When three Borated stainless steel guide tube inserts are used, they will be installed in an assembly's center guide tube, the guide tube associated with the serial number, and the diagonally opposite guide tube. Fuel containing GT-Inserts may be placed in either Region I or Region II. However, credit for GT-Inserts is only taken for Region II storage.

A five-finger CEA may be installed in an assembly.

Fuel containing a five-finger CEA may be placed in either Region I or Region II. Credit for inserted 5-finger CEAs is taken for both Region I and

  • Region II.
e. A nominal 8.85 inch center to center distance between fuel assemblies placed in Region II;
f. A nominal 10.40 inch center to center distance between fuel assemblies placed in Region I; (continued)

SAN ONOFRE--UNIT 2 4.0-4 Amendment No. 213

Design Features 4.0 4.0 DESIGN FEATURES (continued) 4.3.1 Criticality (continued)

g. Prior to using the storage criteria of LCO 3.7.18 and LCS 4.0.100, the following uncertainties will be applied:

(1) The calculated discharge burnup of San Onofre Units 2 and 3 assemblies will be reduced by 6.6%.

(2) The calculated discharge burnup of San Onofre Unit I fuel assemblies will be reduced by 10.0%.

h. Units 2 and 3 fuel assemblies with a burnup in the "acceptable range" of Figure 3.7.18-1 are allowed unrestricted storage in Region I;
i. Units 2 and 3 fuel assemblies with a burnup in the "acceptable range" of Figure 3.7.18-2 are allowed unrestricted storage in the peripheral pool locations with 1 or 2 faces toward the spent fuel pool walls of Region I;
j. Units 2 and 3 fuel assemblies with a burnup in the "acceptable range" of Figure 3.7.18-3 are allowed unrestricted storage in Region II;
k. Units 2 and 3 fuel assemblies with a burnup in the "acceptable range" of Figure 3.7.18-4 are allowed unrestricted storage in the peripheral pool locations with 1 or 2 faces toward the spent fuel pool walls of Region II;
1. Units 2 and 3 fuel assemblies with a burnup in the "unacceptable range" of Figure 3,.7.18-1, Figure 3.7.18-2, Figure 3.7.18-3, and Figure 3.7.18-4 will be stored in compliance with Licensee Controlled Specification 4.0.100 Rev. 2, dated 09/27/07; and
m. Each SONGS 1 uranium dioxide spent fuel assembly stored in Region II shall be stored in accordance with Licensee Controlled Specification 4.0.100 Rev. 2, dated 09/27/07.

(continued)

SAN ONOFRE--UNIT 2 4.0-4a Amendment No. 213

Fuel Storage Pool Boron Concentration B 3.7.17 B 3.7 PLANT SYSTEMS B 3.7.17 Fuel Storage Pool Boron Concentration BASES BACKGROUND As described in LCO 3.7.18, "Spent Fuel Assembly Storage,"

fuel assemblies are stored in the spent fuel racks in accordance with criteria based on initial enrichment, discharge burnup, and cooling time (plutonium decay).

Although the water in the spent fuel pool is normally borated to Ž 2000 ppm, the criteria that limit the storage of a fuel assembly to specific rack locations is conservatively developed without taking credit for boron while maintaining Keff < 1.0. Credit for boron is taken to maintain Keff

  • 0.95.

APPLICABLE Soluble boron in the spent fuel pool is credited in SAFETY ANALYSES criticality analyses for normal and accident conditions.

The relevant accidents are 1) Fuel Assembly Dropped Horizontally On Top of the Racks, 2) Fuel Assembly Dropped Vertically Into a Storage Location Already Containing a Fuel.

Assembly, 3) Fuel Assembly Dropped to the SFP Floor, and 4)

Fuel Misloading in either Region I or Region II. The limiting accident is Fuel Misloading in either Region I or Region II.

A fuel assembly could be inadvertently loaded into a spent fuel rack location not allowed by LCO 3.7.18 (e.g., an un-irradiated fuel assembly or an insufficiently depleted fuel assembly). This accident is analyzed assuming the misloading of one fresh assembly with the maximum permissible enrichment. However, the negative reactivity effect of the soluble boron compensates for the increased reactivity caused by the postulated accident scenario.

Under normal, non-accident conditions, the soluble boron needed to maintain Keff less than or equal to 0.95, including uncertainties, is 970 ppm. Under accident conditions, the soluble boron needed to maintain Keff less than or equal to 0.95, including uncertainties, is 1700 ppm. A SFP boron dilution analysis shows that dilution from 2000 ppm to below 1700 is not credible. Therefore, the minimum required soluble boron concentration is 2000 ppm.

The concentration of dissolved boron in the fuel pool satisfies Criterion 2 of the NRC Policy Statement.

(continued)

SAN ONOFRE--UNIT 2 B 3.7-71 Amendment No. 127 03/05/08

Fuel Storage Pool Boron Concentration B 3.7.17 BASIS (continued)

LCO The specified concentration of 2000 ppm dissolved boron in the fuel pool preserves the assumptions used in the analyses described above. This concentration of dissolved boron is the minimum required concentration for fuel assembly storage and movement within the spent fuel pool.

APPLICABILITY This LCO applies whenever fuel assemblies are stored in the spent fuel pool.

ACTIONS A.1 and A.2 The Required Actions are modified by a Note indicating that LCO 3.0.3 does not apply.

When the concentration of boron in the spent fuel pool is less than required 2000 ppm, immediate action must be taken to preclude an accident from happening or to mitigate the consequences of an accident in progress. This is most efficiently achieved by immediately suspending the movement of fuel assemblies. This does not preclude the movement of fuel assemblies to a safe position. In addition, action must be immediately initiated to restore boron concentration to the required 2000 ppm.

If moving irradiated fuel assemblies while in MODE 5 or 6, LCO 3.0.3 would not specify any action. If moving irradiated fuel assemblies while in MODE 1, 2, 3, or 4, the fuel movement is independent of reactor operation.

Therefore, inability to suspend movement of fuel assemblies is not sufficient reason to require a reactor shutdown.

(conti nued)

SAN ONOFRE--UNIT 2 B 3.7-72 Amendment No. 127 03/05/08

Fuel Storage Pool Boron Concentration B 3.7.17 BASES (continued)

SURVEILLANCE SR 3.7.17.1 REQUIREMENTS This SR verifies that the concentration of boron in the spent fuel pool is within the required limit. As long as this SR is met, the analyzed incidents are fully addressed.

The 7 day Frequency is appropriate because no major replenishment of pool water is expected to take place over a short period of time.

REFERENCES 1. UFSAR, Section 9.1.

SAN ONOFRE--UNIT 2 B 3.7-73 Amendment No. 127 03/05/08 1

Spent Fuel Assembly Storage B 3.7.18 B 3.7 PLANT SYSTEMS B 3.7.18 Spent Fuel Assembly Storage BASES BACKGROUND The spent fuel storage facility is designed to store either new (nonirradiated) nuclear fuel assemblies, or burned (irradiated) fuel assemblies in a vertical configuration underwater. The storage pool is sized to store. 1542 fuel assemblies. Two types/sizes of spent fuel storage racks are used (Region I and Region II). The two Region I racks each contain 156 storage locations each spaced 10.40 inches on center in a 12x13 array. Four Region II storage racks each contain 210 storage locations in a 14x15 array. The remaining two Region II racks each contain 195 locations in a 13x15 array. All Region II locations are spaced 8.85 inches on center.

To maintain Keff < 0.95 for spent fuel of maximum enrichment, up to 4.8 w/o, (1) soluble boron is credited, and (2) the following storage patterns and borated stainless steel guide tube inserts are used as needed:

(1) unrestricted storage, minimum discharge burnup and cooling time requirements vs. initial enrichment, (2) SFP Peripheral storage, minimum discharge burnup and cooling time requirements vs. initial enrichment, (3) 2x2 storage patterns, minimum discharge burnup and cooling time requirements vs. initial enrichment, (4) 3x3 storage patterns, minimum discharge burnup and cooling time requirements vs. initial enrichment, (5) credit for inserted Control Element Assemblies (CEAs),

(6) credit for erbia in fresh assemblies, (7) credit for cooling time (Pu-241 decay), and, (8) credit for borated stainless steel guide tube inserts.

(continued)

SAN ONOFRE--UNIT 2 B 3.7-74 Amendment No. 127 03/05/08

Spent Fuel Assembly Storage B 3.7.18 BASES (continued)

BACKGROUND When soluble boron is credited, the following acceptance (continued) criteria apply:

(1) Under normal conditions, the 95/95 neutron multiplication factor (Keff), including all uncertainties, shall be less than 1.0 when flooded with unborated water, and, (2) Under normal and accident conditions, the 95/95 neutron multiplication factor (Keff), including all uncertainties, shall be less than or equal to 0.95 when flooded with borated water.

APPLICABLE The spent fuel storage facility is designed for SAFETY ANALYSES noncriticality by use of adequate spacing, neutron absorbing stainless steel cans, borated water with a minimum soluble boron concentration of 970 ppm, and storage of fuel assemblies in accordance with the administrative controls in LCO 3.7.18 and LCS 4.0.100, "Fuel Storage Patterns".

The spent fuel assembly storage satisfies Criterion 2 of the NRC Policy Statement.

LCO The restrictions on the placement of fuel assemblies within the spent fuel pool, in the accompanying LCO, ensure that the Keff of the spent fuel pool will always remain

< 1.00 under normal, non-accident conditions assuming the pool to be flooded with unborated water. The Keff of the spent fuel pool will always remain

  • 0.95 under normal, non-accident conditions assuming the pool to be flooded with borated water with a minimum soluble boron concentration of 970 ppm. The Keff of the spent fuel pool will always remain

< 0.95 under accident conditions assuming the pool to be flooded with borated water with a minimum soluble boron concentration of 1700 ppm. The restrictions are consistent with the criticality safety analysis performed for the-spent fuel pool.

(continued)

SAN ONOFRE--UNIT 2 B 3.7-75 Amendment No. 127 03/05/08

Spent Fuel Assembly Storage B 3.7.18 BASES (continued)

APPLICABILITY This LCO applies whenever any fuel assembly is stored in Regions I and II of the spent fuel pool.

ACTIONS A.1 Required Action A.1 is modified by a Note indicating that LCO 3.0.3 does not apply.

When the configuration of fuel assemblies stored in Regions I and II of the spent fuel pool is not in accordance with LCO 3.7.18, immediate action must be taken to make the necessary fuel assembly movement(s) to bring the configuration into compliance.

If moving irradiated fuel assemblies while in MODE 5 or 6, LCO 3.0.3 would not specify any action. If moving irradiated fuel assemblies while in MODE 1, 2, 3, or 4, the fuel movement is independent of reactor operation.

Therefore, in either case, inability to move fuel assemblies is not sufficient reason to require a reactor shutdown.

SURVEILLANCE SR 3.7.18.1 REQUIREMENTS This SR verifies by administrative means that the fuel assembly is stored in accordance with LCO 3.7.18, or Design Features 4.3.1.1, or LCS 4.0.100. For fuel assemblies not stored in accordance with LCO 3.7.18, performance of this SR will ensure compliance with Specification 4.3.1.1.

This surveillance is performed prior to the initial storage of a fuel assembly in a spent fuel pool location and prior to each subsequent movement to a new location.

REFERENCES UFSAR, Section 9.1.2.2.

SAN ONOFRE--UNIT 2 B 3.7-75a Amendment No. 127 03/05/08

Distribution Systems-Operating B 3.8.9 BASES (continued)

Table B 3.8.9-1 (page I of 1)

AC and DC Electrical Power Distribution Systems TYPE VOLTAGE TRAIN A TRAIN B AC safety 4160 V ESF Bus A04 ESF Bus A06 buses 480 V Load Center B04 Load Center B06 TRAIN A TRAIN. C TRAIN B TRAIN D Bus D1 Bus D3 Bus D2 Bus D4 DC buses(3) 125 V from from from from battery battery battery battery B007 and B009 and B008 and BO0O and charger charger charger charger BOO1 (4) B003 (4) B002 ) B004 (5)

TRAIN A TRAIN C TRAIN B TRAIN D AC vital Bus Y01 Bus Y03 Bus Y02 Bus Y04 buses 120 V from from from from inverter inverter inverter inverter YO01 Y003 Y002 Y004 connected connected connected connected to bus D1 to bus D3 to bus D2 to bus D4 NOTES: (1) Each train of the AC, DC, and AC vital bus electrical power distribution systems is a subsystem.

(2) If a support system (e.g., charger or inverter) is declared inoperable and it has its own LCO, entry into LCO 3.8.9 is not required. Only entry into its LCO is required.

(3) An OPERABLE Class IE battery bank BOOX may replace any battery BOO7 through B010 to allow battery maintenance (including replacement) activities.

(4) Swing Charger B021 may be aligned as the OPERABLE charger in place of BOO1 or B003.

(5) Swing Charger B022 may be aligned as the OPERABLE charger in place of B002 or B004.

SAN ONOFRE--UNIT 2 B 3.8-83 Amendment No. 127 03/05/08 1

SAN ONOFRE UNIT 2 LICENSEE CONTROLLED SPEC IFICATIONS LIST OF EFFECTIVE PAGES Page No. Rev. Date Page No. Rev. Date LOEP-I 03/05/08 3.1-103-2 04/24/96 LOEP-2 08/29/07 3.1-103-3 04/24/96 LOEP-3 12/12/07 3.1-104-1 12/02/02 LOEP-4 03/05/08 3.1-104-2 02/12/99 LOEP-5 09/27/07 3.17104-3 02/12/99 LOEP-6 11/30/07 3.1-104-4 11/18/99 ii 09 /07/06 3.1-105-1 .11/12/98 iii 09/07/06 3.1-105-2 07 /29/96 09/07/06 3.1-105-3 02/19/97 iv 06/27/00 3.1-105-4 02/19/97 v 09/07/06 3.1-105-5 02/19/97 2.0-100-1 05/25/00 3.1-105-6 02/19/97 2.0-100-2 04/24/96 3.1-105-7 07 /29/96 2.0-100-3 05/25/00 3.1-105-8 07 /29/96 2.0-100-4 04/24/96 3.1-105-9 12/02/96 2.0-100-5 03/29/99 3.1-106-1 05/2 5/00 2.0-100-6 03/29/99 3.1-106-2 05/2 5/00 2.0-100-7 03/29/99 3.1-106-3 05/31/97 2.0-100-8 03/29/99 3.1-106-4 05/17/99 2.0-100-9 03/29/99 3.1-106-5 05/17/99 2.0-100-10 03/29/99 3.1-106-6 05/2 /00 2.0-100-11 05/12/00 3.1-107-1 11/18/05 2.0-100-12 05/12/00 3.1-107-2 11/ 18/05 2.0-100-13 05/12/00 3.1-107-3 11/ 18/05 2.0-100-14 03/29/99 3.1-107-4 11/ 18/05 2.0-100-15 03/29/99 3.1-107-5 11/ 18/05 2.0-100-16 03/29/99 3.1-108-1 07 /20/06 2.0-100-17 03/29/99 3.1-108-2 11/18/05 2.0-100-18 05/25/00 3.1-108-3 11/18/05 3.0-1 05/25/00 3.1-108-4 11/18/05 3.0-la 05/25/00 3.1-108-5 11/18/05 3.0-2 03/14/02 3.2-100-1 02/15 /06 3.0-3 03/14/02 3 2-100-2 04/24/96 3.0-4 03/14/02 3.2-100-3 04/24/96 3.0-5 03/14/02 3.2-101-1 02/19/99 3.0-6 03/14/02 3.2-101-2 02/19/99 3.1-100-1 11/12/98 3.2-101-3 06 /22. 98 3.1-100-2 05/13/97 3.2-101-4 02/19/99 3.1-100-3 01/15/97 3.2-101-5 02/19/97 3.1-101-1 05/25/00 3.2-101-6 02/1/9 7 3.1-101-2 04/24/96 3.2-102-1 04/16/99 3.1-101-3 04/16/99 3.2-102-2 04/16/99 3.1-101-4 04/16/99 3.3-100-1 08/29/07 3.1-101-5 05/25/00 3.3-100-2 08/01/96 3.1-102-1 02/12/99 3.3-100-3 04/24/96 3.1-102-2 02/12/99 3.3-100-4 08/29/07 3.1-102-3 02/12/99 3.3-100-5 08/29/07 3.1-103-1 11/12/98 3.3-100-6 08/29/07 NDMS Revision I Page R of 6 03/05/08

SAN ONOFRE UNIT 2 LICENSEE CONTROLLED SPECIFICATIONS SAN ONOFRE UNIT 2 LICENSEE CONTROLLED SPECIFICATIONS LIST OF EFFECTIVE PAGES Page No. Rev. Date Page No. Rev. Date 3.3-100-7 01/28/05 3.3-108-6 10/05/00 3.3-101-1 08/29/07 3.3-109-1 02/20/07 3.3-101-2 08/29/07 3.3-109-la 02/20/07 3.3-101-3 08/29/07 3.3-109-2 02/20/07 3.3-102-1 04/19/04 3.3-109-3 02/20/07 3.3-102-2 04/ 1.9/04 3.3-109-4 02/20/07 3 .3-102-2a 04/19/04 3.3-109-5 02 /2007 3 .3-102-2b 04/19/04 3.3-109-6 02 /2007 3.3-102-3 04/24/96 3.3-110-1 07 2 /01 3.3-102-4 01/05/01 3.3-110-2 07 02/01 3.3-102-5 01/05/01 3.3-110-3 07 02/01 3.3-102-6 01/05/01 3.3-110-4 07 /0201 3.3-102-7 01/05/01 3.3-110-5 07 23/01 3.3-102-8 04/19/04 3.3-111-1 02 05/01 3.3-102-8a 04/19/04 3.3-111-2 03 /0698 3.3-102-8b 04/19/04 3.3-111-3 03 /0698 3.3-102-9 01/05/01 3.3-111-4 02 05/01 3.3-102-10 01/05/01 3.3-111-5 02 05/01 3.3-102-11 01/05/01 3.3-112-1 12 05S06 3.3-103-1 05/25/00 3.3-112-2 12 05 06 3.3-103-2 04/24/96 3.3-112-3 12 05S06 3.3-103-3 05/25/00 3.3-112-4 12 05/06 3.3-104-1 05/2 5/00 3.3-112-5 12 05S06 3.3-104-2 05/25/00 3.3-112-6 12 05/06 3.3-104-3 12/14/00 3.3-112-7 12 05S06 3.3-104-4 01/29/99 3.3-112-8 12 05S06 3.3-104-5 05/2 5/00 3.3-112-9 12 05/06 3.3-105-1 05/25/00 3.3-113-1 10 /2703 3.3-105-2 04/24/ 96 3.3-113-2 03 19/03 3.3-105-3 05/2 5/00 3.3-113-3 03 /1903 3.3-106-1 06/07/0 1 3.3-113-4 10 27/03 3.3-106-2 04/23/01 3.3-113-5 10 27/03 3.3-106-3 03/29/99 3.3-113-6 03 19/03 3.3-106-4 03/29/99 3.3-113-7 10 27/03 3.3-106-5 05/30/97 3.3-114-1 10 27/03 3.3-106-6 05/30/97 3.3-114-2 03 19/03 3.3-106-7 05/30/97 3.3-114-3 03 19/03 3.3-106-8 06/07/01 3.3-114-4 03 19/03 3.3-106-9 06/07/01 3.3-114-5 10 27/03 3.3-106-10 04/23/01 3.3-114-6 03 19/03 3.3-107-1 08/22/00 3.3-114-7 10 27/03 3.3-107-2 04/24/96 3.3-115-i 04 S/05 3.3-107-3 05/25/00 3.3-115-2 04 5/05 3.3-108-1 10/05/00 3.3-115-3 04 S/05 3.3-108-2 04/24/96 3.3-115-4 04 25/05 3.3-108-3 10/05/00 3.4-101-1 05 25/00 3.3-108-4 10/05/00 3.4-101-2 05 25/00 3.3-108-5 10/05/00 3.4-101-2a 05 25/00 NDMS Revision I Page 2 of 6 08/29/07

SAN ONOFRE UNIT 2 LICENSEE CONTROLLED SPECIFICATIONS LIST OF EFFECTIVE PAGES Page No. Rev. Date Page No. Rev. Date 3.4-101-3 04/2 4/96 3.6-101-2 2 02/23/04 3.4-101-4 04/28/97 3.6-101-3 0 04/24/96 3.4-101-5 07/12/99 3.6-101-4 1 12/27/96 3.4-101-6 07/12/99 3.6-101-5 2 02/23/04 3.4-101-7 07/12/99 3.6-101-6 0 04/24/96 3.4-101-8 05/25/00 3.6-101-7 0 04/24/96 3.4-101-9 07/12/99 3.6-101-8 3 02/23/04 3.4-102-1 02/11/03 3.7-101-1 1 12/18/02 3.4-102-2 05/2 5/00 3.7-101-2 0 09/21/02 3.4-102-3 01/21/98 3.7-101-3 0 09/21/02 3.4-102-4 02/11/03 3.7-101-4 1 12/18 02 3.4-103-1 12/12/07 3.7-101-5 0 09/21 02 3.4-103-2 12/12107 3.7-101-6 1 12/18 02 3.4-103-3 12/12/07 3.7-101-7 0 09/21 02 3.4-103-4 12/12/07 3.7-101-8 1 12/18 02 3.4-103-5 12/12/07 3.7-101-9 0 09 /2 02 3.4-103-6 12/12/07 3.7-101-10 0 09/21/02 3.4-103-7 12/12/07 3.7-101-11 0 09 /21/02 3.4-103-8 12/12/07 3.7-101-12 0 09/21 02 3.4-106-1 12/12/07 3.7-102-1 8 04/2 301 3.4-106-2 12/12/07 3.7-102-2 4 04/2 /01 12/12/07 3.7-102-3 1 11/21/97 3.4-106-3 3.4-107-1 12/1.2/07 3.7-102-4 11/21/97 3.4-107-2 12/12/07 3.7-102-5 3 05/24/00 3.4-107-3 12/12/07 3.7-102-6 2 11/21 97 3.4-112.1-1 12/12/07 3.7-102-7 6 04/2 3/01 3.4-112.1-2 12/12/07 3.7-103-1 7 04/12 07 3.4-112.1-3 12/12/07 3.7-103-2 3 04/12 /07 3.4-112.2-1 12/12/07 3.7-103-3 2 07/29 99 3.4-112.2-2 12/12/07 3.7-103-4 0 04/24 96 3.4-112.2-3 12/12/07 3.7-103-5 0 04/24 96 3.5-100-1 04/24/96 3.7-103-6 1 05/09 97 3.5-100-2 04/24/96 3.7-103-7 2 08/20 98 3.5-101-1 12/23/99 3.7-103-8 5 04/12/07 3.5-101-2 04/24/96 3.7-104-1 5 07/16/04 3.5-101-3 04/24/96 3.7-104-2 3 05/25 00 3.5-101-4 12/2 3/99 3.7-104-3 2 07/16 04 3.6-100-1 0211/102 3.7-104-4 4 07/16 04 3.6-100-2 02/02/0 1 3.7-104-5 2 07/16/04 3.6-100-3 0211/102 3.7-105-2 13 05/29/07 3.6-100-4 02/02/01 3.7-105-2 5 05/09/01 3.6-100-5 02/02/01 3.7-105-3 3 05/09/01 3.6-100-6 02/02/01 3.7-105-4 5 06/3 /03 3.6-100-7 02/02/01 3.7-105-5 4 11/14/06 3.6-100-8 02/02/0 1 3.7-105-6 3 05/09/01 3.6-100-9 02/02/ 01 3.7-105-7 3 05/09/0 1 3.6-100-10 02/02/0 1 3.7-105-8 4 10/29/04 3.6-101-1 02/23/04 3.7-105-9 5 07/2 1/05 NDMS Revision I Page 3 of 6 12/12/07

SAN ONOFRE UNIT 2 LICENSEE CONTROLLED SPECIFICATIONS LIST OF EFFECTIVE PAGES Paqe No. Rev. Date Page No. Rev. Date 3.7-105-10 05/2 9/07 3.7-112-2 0 04/24/96 3.7-105-11 05/09/01 3.7-112-3 1 05/2 5/00 3.7-105-12 05/2 9/07 3.7-113-1 20 12 /21/06 3.7-105-13 06/3 0/03 3.7-113-2 4 06/27/00 3.7-105-14 06/30 /03 3.7-113-3 5 05/16/01 3.7-105-15 05/2 9/07 3.7-113-4 10 09 /20/05 3.7-105-16 05/2 9/07 3.7-113-5 3 05/16/01 3.7-105-17 05/09/ 01 3.7-113-6 2 06/27/00 3.7-105-18 05/2 9/07 3.7-113-7 3 11/13/03 3.7-105-19, 06/30/03 3.7-113-8 2 03 /28/05 3.7-105-20 06/30 /03 3.7-113-9 3 06/27/00 3.7-105-21 05/09/01 3.7-113-10 5 05/16/01 3.7-105-22 05/09/01 3.7-113-11 2 03 /28/05 3.7-105-23 07/21/05 3.7-113-12 3 07/13/05 3.7-106-1 10/28/02 3.7-113-13 2 06/27/00 3.7-106-2 12/18/98 3.7-113-14 3 12/21/06 3.7-106-3 05/25/00 3.7-113-15 2 06/27/00 3.7-106-4 12/18/98 3.7-113-16 1 06/27/00 3.7-106-5 10/28/02 3.7-113-17 2 06/27/00 3.7-106-6 10/28/02 3.7-113-18 2 06/27/00 3.7-106-7 10/28/02 3.7-113-19 1 06/27 00 3.7-106-8 10/28/02 3.7-113-20 3 07/13//05 3.7-106-9 10/28/02 3.7-113-21 4 .12/21/06 3.7-106-10 10/28/02 3.7-113-22 3 07/13/05 3.7-107-1 05/25/00 3.7-113-23 2 12/21/06 3.7-107-2 04/24/96 3.7-113-24 7 06/27/00 3.7-107-3 04/24/96 3.7-113-25 1 06/27/00 3.7-107-4 .05/25/00 3.7-113-26 2 06 /2700 3.7-108-1 06/28/02 3.7-114-1 1 O5 /2 00 3.7-108-2 10/04/00 3.7-114-2 0 08 14/96 3.7-108-3 10/19/98 3.7-114-3 1 05 /2 00 3.7-108-4 10/19/98 3.7-115-1 1 05 /2 00 3.7-108-5 11/27/96 3.7-115-2 0 08 /796 3.7-108-6 04/2 4/96 3.7-115-3 1 05 /2 00 3.7-108-7 06/28/02 3.7-116-1 4 03 / 08 3.7-108-8 05/09/ 97 3.7-116-2 3 03 /0508 3.7-108-9 06/28/02 3.7-117-1 2 06 12/02 3.7-108-10 10/04/00 3.7-117-2 2 0612' 02 3.7-109-1 05/2 5/00 3.7-118-1 2 12/ 0/06 3.7-109-2 07/29/99 3.7-118-2 2 12 05/06 3.7-109-3 05/2 5/00 3.7-118-3 0 12 0//06 3.7-110-1 05/23 /01 3.7-118-4 0 125 '/06 3.7-110-2 04/24/96 3.7-118-5 0 12 0//06 3.7-110-3 02 /28/01 3.7-118-6 0 12 0//06 3.7-111-1 05/25/00 3.8-100-1 9 04/ 25/05 3.7-111-2 04/24/96 3.8-100-2 3 03/28/05 3.7-111-3 05/25/00 3.8-100-3 1 03 06/01 3.7-112-1 05/25/00 3.8-100-4 1 05/28/97 NDMS Revision I Page 4 of 6 03/05/08

SAN ONOFRE UNIT 2 LICENSEE CONTROLLED SPECIFICATIONS LIST OF EFFECTIVE PAGES Page No. Rev. Date Page No. Rev. Date 3.8-100-5 11/22/99 3.9-107-2 05/2 5/00 3.8-100-6 05/28/97 3.9-107-3 12/21/00 3.8-100-7 11/22/99 3.9-107-4 12/2 1/00 3.8-100-8 11/22/99 4.0-100-1 09/27/07 3.8-100-9 11/22/99 4.0-100-2 09/27/07 3.8-100-10 11/22/99 4.0-100-3 09/27/07 3.8-100-11 05/28/97 4.0-100-4 09/27 /07 3.8-100-12 05/28/97 4.0-100-5 09/27 /07 3.8-100-13 04/25/05 4.0-100-6 09/27/07 3.8-100-14 03/06/01 4.0-100-7 09/27/07 3.8-100-15 03/12/02 4.0-100-8 09/27 /07 3.8-100-16 03/12/02 4.0-100-9 09/27/07 3.8-100-17 03/12/02 4.0-100-10 09/27/07 3.8-100-18 03/12/02 4.0-100-11 09/27/07 3.8-101-1 05/27/05 4.0-100-12 09/27/07 3.8-101-2 05/27/05 4.0-100-13 09/27/07 3.8-101-3 04 /24/96 4.0-100-14 09/27/07 3.8-101-4 04/24/96 4.0-100-15 09/27/07 3.8-101-5 04/24/96 4.0-100-16 09/27/07 3.8-101-6 05/28/97 4.0-100-17 09/27/07 3.8-101-7 05/28/97 4.0-100-18 09/27/07 3.8-101-8 05/2 5/00 4.0-100-19 09/27/07 3.8-102-1 01/03/00 .4.0-100-20 09/27/07 3.8-102-2 01/03/00 4.0-100-21 09/27/07 3.8-102-3 01/03/00 4.0-100-22 09/ /207 3.8-102-4 01/03/00 4.0-100-23 09/27/07 3.8-102-5 01/03/00 4.0-100-24 09/27/07 3.8-102-6 01/03/00 4.0-100-25 09/27/07 3.8-102-7 01/03/00 4.0-100-26 09/27/07 3.8-102-8 01/03/00 4.0-100-27 09/27/07 3.8-102-9 01/03/00 4.0-100-28 09/27/07 3.9-100-1 11/18/05 4.0-100-29 09/27/07 3.9-100-2 11/18/05 4.0-100-30 09/27/07 3.9-100-3 11/18/05 4.0-100-31 09/27/07 3.9-101-1 05/25/00 4.0-100-32 09/27/07 3.9-101-2 05/25/00 4.0-100-33 09/27/07 3.9-102-1 05/25/00 4.0-100-34 09/27/07 3.9-102-2 05/25/00 4.0-100-35 09/27/07 3.9-103-1 05/25/00 4.0-100-36 09/27/07 3.9-103-2 05/09/97 4.0-100-37 09/27/07 3.9-103-3 o5/25/00 4.0-100-38 09/27/07 3.9-104-1 o5/25/00 4.0-100-39 09/27/07 3.9-104-2 o5/25/00 4.0-100-40 09/27/07 3.9-104-3 05/25/00 4.0-100-41 09/27/07 3.9-106-1 05/25/00 4.0-100-42 09/27/07 3.9-106-2 04/24/96 .4.0-100-43 09/27/07 3.9-106-3 o5/2 5/00 4.0-100-44 09/27/07 3.9-107-1 12 /21/00 NDMS Revision I Page 5 of 6 09/27/07

SAN ONOFRE UNIT 2 LICENSEE CONTROLLED SPECIFICATIONS LIST OF EFFECTIVE PAGES Page No. Rev. Date Page No; Rev. Date 4.0-100-45 2 09/27/07 4.0-100-46 2 09/27/07 4.0-100-47 2 09/27/07 4.0-100-48 2 09/27/07 4.0-100-49 2 09/27/07 4.0-100-50 2 09/27/07 4.0-100-51 2 09/27/07 4.0-100-52 2 09/27/07 4.0-100-53 2 09/27/07 4.0-100-54 2 09/27/07 4.0-100-55 2 09/27/07 4.0-100-56 2 09/27/07 4.0-100-57 2 09/27/07 4.0-100-58 2 09/27/07 4.0-100-59 2 09/27/07 4.0-100-60 2 09/27/07 4.0-100-61 2 09/27/07 4.0-100-62 2 09/27/07 4.0-100-63 2 09/27/07 5.0-100-1 3 08/29/06 5.0-100-2 3 08/29/06 5.0-100-3 1 08/29/06 5.0-100-4 1 09/24/03 5.0-101-1 0 04/24/96 5.0-103-1 5 11/30/07 5.0-103-2 2 11/30/07 5.0-103-3 0 04/24/96 5.0-103-4 5 02/28/01 5.0-103-5 0 04/24/96 5.0-103-6 1 11/06/06 5.0-104-1 1 02 14/97 5.0-104-2 1 02/14/97 5.0-105-1 2 03/21/06 5.0-105-2 2 03/21/06 NDMS Revision 1 Page 6 of 6 11/30/07

(LCS 3.7.116 deleted upon implementation of Amendment 213)

SAN ONOFRE--UNIT 2 3.7-116-1 Rev. 4 03/05/08 I

(LCS 3.7.116 deleted upon implementation of Amendment 213)

SAN ONOFRE--UNIT 2 3.7-116-2 Rev. 3 03/05/08

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES LCS 4.0.100 Fuel Storage Patterns NOTE 1:

This Licensee Controlled Specification is listed by revision number and data in Technical Specification 4.3.1. All changes to pages I through 61 Rev. 2 dated 09/27/2007 of this LCS (i.e.., excluding the Bases pages) must be approved by the NRC via the amendment application process in conjunction with an associated change to Technical Specification 4.3.1.

NOTE 2:

Prior to using the storage criteria in 4.0.100.1, 4.0.100.2, and 4.0.100.4 below, the following uncertainties shall be applied:

(1) The calculated discharge burnup of San Onofre Units 2 and 3 fuel assemblies will be reduced by 6.6%.

(2) The calculated discharge burnup of San Onofre Unit 1 fuel assemblies will be reduced by 10.0%.

VALIDITY STATEMENT: Rev. 2 effective upon NRC approval, to be implemented within 180 days.

4.0.100 New or burned fuel (which does not meet the criteria of LCO 3.7.18 for unrestricted storage or storage at the pool periphery) may be stored in Region I or Region II in accordance with the allowable Storage Patterns described in this LCS.

4.0.100.1 Region I = Region I Storage Patterns are given in Tables I-I through 1-8 and Figures I-i through I-9.

4.0.100.2 Region II = Region II Storage Patterns are given in Tables 11-1 through 11-15 and Figures II-1 through 11-22.

4.0.100.3 SONGS Unit 1 Fuel shall not be stored in Region I Racks.

4.0.100.4 The burnup of each SONGS Unit 1 uranium dioxide spent fuel assembly stored in Region II shall meet the following criteria:

(continued)

SAN ONOFRE--UNIT 2 4.0-100-1 Rev. 2 09/27/07

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued) 4;0.100.4.1 SONGS Unit I nominal 3.40 w/o assemblies can be stored in the Region II Racks (unrestricted) if:

the burnup is greater than 25,000 MWD/T, and the cooling time is.greater than 5 years.

4.0.100.4.2 SONGS Unit 1 nominal 4.00 w/O assemblies can be stored in the Region II Racks (unrestricted) if:

the burnup is greater than 26,300 MWD/T, and the cooling time is greater than 20 years.

the burnup is greater than 27,100 MWD/T, and the cooling time is greater than 15 years.

the burnup is greater than 28,200 MWD/T, and the cooling time is greater than 10 years.

4.0.100.4.3 SONGS Unit 1 nominal 4.00 w/o assemblies can be stored in the Region II Racks (SFP periphery) if:

the burnup is greater than 20,000 MWD/T, and the cooling time is greater than 0 years.

4.0.100.5 Design Requirements For Guide Tube Inserts (i) GT-Inserts shall be 0.75 inches O.D. minimum, completely cover the active fuel region (150 inches),

and have a minimum boron content of 0.02434 grams of B-10 per cm3 .

(ii) Three (3) or 5 GT-Inserts are allowed. The orientation of every fuel assembly with 3 guide tube inserts shall be the same (Figure 11-23).

(iii) A 5-finger, full length Control Element Assembly (CEA) may be used in place of borated stainless steel or aluminum guide tube inserts.

4.0.100.6 Design requirements For Erbia Assemblies containing 40 or 80 erbia rods shall have the erbia rods distributed per Figures 11-24 and 11-25. The minimum initial nominal erbia loading shall be 2.0 w/o Er2O3.

4.0.100.7 The Failed Fuel Rod Storage Basket (FFRSB)

The Failed Fuel Rod Storage Basket (FFRSB) shall be. treated as if it were an assembly with enrichment and burnup of the rod in the basket with the most limiting combination of enrichment and burnup.

(continued)

SAN ONOFRE--UNIT 2 4.0-100-2 Rev. 2 09/27/07 1

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued) 4.0.100.8 Non-Fuel Components Neutron sources and non-fuel bearing assembly components (thimble plugs, CEAs, etc) may be stored in fuel assemblies without affecting the storage requirements of these assemblies. A storage basket containing no fissile material can be stored in any storage location, and can, be used as a storage cell blocker for reactivity control.

4.0.100.9 Fuel Assembly Reconstitution Station A fuel assembly reconstitution station is a special case of a checkerboard pattern. A reconstitution station is permitted anywhere in the Region I racks. The empty cells in the checkerboard pattern do not need to be blocked. A reconstitution station is permitted anywhere in the Region II racks provided that empty cells in the checkerboard pattern are blocked to make it impossible to misload a fuel assembly during reconstitution activities.

(continued)

SAN ONOFRE--UNIT 2 4.0-100-3 Rev. 2 09/27/07 1

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Table I-I REGION I Category I-I Fuel (Unrestricted Storage)

Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o 0 Years 5 Years 10 Years 15 Years 20 Years Cooling Cool ing Cooling Cooling Cooling 5.00 22.84 21.47 20.59 20.04 19.67 4.50 18.61 17.57 16.89 16.45 16.17 4:00 14.30 13.58 13.09 12.78 12.57 3.50 9.84 9.40 9.11 8.92 8.79 3.00 5.24 5.02 4.91 4.84 4.79 2.47 0.00 0.00 0.00 0.00 0.00 Category Category I-1 1-1 Category Category 1-1 I-i Note: Category I-i and fresh fuel with full-length 5-finger CEAs (Table 1-5) may be stored together with no restrictions.

(continued)

SAN ONOFRE--UNIT 2 4.0-100-4 Rev. 2 09/27/07

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Table J-2 REGION I Category 1-2 Fuel (SFP Peripheral Storage)

Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cool i ng Cooling Cooling Cooling Cooling 5.00 12.55 12.15 11.82 11.61 11.47 4.50 9.09 8.85 8.63 8.49 8.40 4.00 5.58 5.43 5.33 5.25 5.21 3.50 2.22 2.13 2.09 2.05 2.03 3.20 0.00 0.00 0.00 0.00 0.00 P P 0 0 0 0 L

Category Category Category 0 00 1-2 I-I I-1 W

A o A L o L L 0___ L Category Category Category 0 00 Category Category Category 1 -2 1-2 1-2 1-2 1-2 1-2 POOL WALL (continued)

SAN ONOFRE--UNIT 2 4.0-100-5 Rev. 2 09/27/07

Fuel Storage Patterns for Region II Racks LCS 4.0. 100 4.0 DESIGN FEATURES (continued)

Table 1-3 REGION I Category 1-3 Fuel (Filler Assembly For I-out-of-4 Pattern)

Ini ti al Minimum Burnup (GWD/T)

Enrichment (w/O) 0 Years 5 Years 10 Years 15 Years 20 Years Cooling Cool ing Cool ing Cooling Cooling 5,00 39.99 36.28 34.27 33.04 32.22 4.50 34.95 31.71 29.94 28.84 28.12 4,00 29.71 26.99 25.46 24.51 23.89 3,50 24.22 22.03 20.79 20.02 19.52 3,00 18.37 16.84 15.91 15.34 14.97 2.50 12.21 11.30 10.72 10.37 10.13 2.00 5.28 5.05 4.85 4.72 4.62 1.71 0.00 0.00 0.00 0.00 0.00 4.80 Category Fresh 1-3 Category Category 1-3 1-3 (continued)

SAN ONOFRE--UNIT 2 4.0-100-6 Rev. 2 09/27/07 1

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Table 1-4 REGION I 4.80 w/o Fresh Fuel Checkerboard Pattern Initial Minimum Burnup (GWD/T)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cooling Cooling Cooling Cool ing Cooling 4.80 0.00 0.00 0.00 0.00 0.00 4.80 Empty Fresh Empty 4.80 Fresh (continued)

SAN ONOFRE--UNIT 2 4.0-100-7 Rev . 2 09127107 1

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Table 1-5 REGION I 4.8 w/o Fresh Fuel With Full-Length, 5-Finger CEA (Unrestricted Storage)

Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cool ing Cooling Cool ing Cooling Cooling 4.80 0.00 0.00 0.00 0.00 0.00 4.80 4.80 Fresh Fresh With CEA With CEA 4.80 4.80 Fresh Fresh With CEA With CEA Note: Category I-I and fresh fuel with full-length 5-finger CEAs (Table 1-5) may be stored together with no restrictions.

(continued)

SAN ONOFRE--UNIT 2 4.0-100-8 Rev. 2 09/27/07 1

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Table 1-6 REGION I Category 1-4 Fuel (Filler Assembly For 1-out-of-4 Pattern)

Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cool ing Cooling Cooling Cooling Cooling 5.00 26.57 24.71 23.59 22.90 22.44 4.50 22.12 20.62 19.73 19.17 18.80 4.00 17.54 16.46 15.78 15.35 15.07 3.50 12.84 12.12 11.66 11.37 11.18 3.00 7.95 7.56 7.31 7.15 7.05 2.50 2.76 2.64 2.56 2.50 2.46 2.27 0.00 0.00 0.00 0.00 0.00 4.80 Category Fresh 1-4 80 Erbia Category Category 1-4 1-4 (continued)

SAN ONOFRE--UNIT 2 4.0- 100-9 Rev. 2 09/27/07

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Table 1-7 REGION I Category 1-5 Fuel (Filler Assembly For 1-out-of-4 Pattern)

Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cool ing Cool i ng Cooling Cool ing Cooling 5.00 30.81 28.40 27.00 26.14 25.57 4.50 26.17 24. 17 22.99 22.26 21.78 4.00 21.32 19.77 18.84 18.27 17.88 3.50 16.32 15.22 14.55 14.13 13.85 3.00 11. 11 10.45 10.05 9.79 9.61 2.50 5.55 5.30 5.14 5.04 4.98 2.07 0.00 0.00 0.00 0.00 0.00 4.80 Category Fresh 1-5 40 Erbia Category Category I-5 I-5 (continued)

SAN ONOFRE--UNIT 2 4.0-100-10 Rev. 2 09/27/07

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Table J-8 REGION I Checkerboard Pattern Category 1-6 Fuel (4.80 w/o Assembly Depleted to 18.0 GWD/MTU)

Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cool ing Cooling Cooling Cooling Cooling 5.00 19.82 18.84 18.12 17.67 17.37 4.50 15.83 15.11 14.58 14.24 14.01 4.00 11.75 11.28 10.92 10.69 10.54 3.50 7.56 7.23 7.04 6.91 6.83 3.00 3.28 3.15 3.07 3.03 2.99 2.65 0.00 0.00 0.00 0.00 0.00 Category 1-4 Fuel (Checkerboard Partner For Category 1-6 Fuel)

Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cooling Cool ing Cooling Cooling Cooling 5.00 26.57 24.71 23.59 22.90 22.44 4.50 22. 12 20.62 19.73 19. 17 18.80 4.00 17.54 16.46 15.78 15.35 15.07 3.50 12.84 12.12 11.66 11.37 11.18 3.00 7.95 7.56 7.31 7.15 7.05 2.50 2.76 2.64 2.56 2.50 2.46 2.27 0.00 0.00 0.00 0.00 0.00 Category Category 1-4 1-6 Category Category 1-6 1-4 Table 11-1 (continued)

SAN ONOFRE--UNIT 2 4.0-100-11 Rev . 2 09/27/07

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

REGIOON II Category I1-I Fuel (Unrestricted Storage)

Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cooling Cooling Cool ing Cooling Cooling 5.00 53.76 47.77 44.75 43.00 41.86 4.50 48.43 42.93 40.15 38.52 37.47 4.00 42.91 37.94 35.40 33.92 32.96 3.00 30.99 27.26 25.30 24.16 23.43 2.00 17.05 14.97 13.90 13.25 12.83 1.87 14.93 13.23 12.26 11.68 11.31 1.23 0.00 0.00 0.00 0.00 0.00 Category Category 11-1 II-1 Category Category 11-1 II-1 Note: Category II-1, 11-8, 11-9, and 11-15 may be stored together with no restrictions.

(continued)

SAN ONOFRE--UNIT 2 4.0-100-12 Rev . 2 09/27/07

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Table 11-2 REGION II Category 11-2 Fuel (SFP Peripheral Storage)

Initial Minimum Burnup GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cooling Cooling Cooling Cooling Cooling 5.00 36.95 33.68 31.89 30.81 30.10 4.50 32.29 29.44 27.87 26.91 26.28 4.00 27.44 25.04 23.70 22.88 22.35 3.00 16.95 15.62 14.83 14.34 14.03 2.00 4.93 4.67 4.52 4.42 4.35 1.87 3*04 2.87 2.76 2.69 2.64 1.70 0.00 0.00 0.00 0.00 0.00 P P 0 0 0 0 L L Category Category Category 0 0 Category Category Category 11-2 11-I ll-I 11-1 11-I 11-2 W W A o A L o L Lo L Category Category Category 0 0 Category Category Category 11-2 11-2 11-2 11-2 11-2 11-2 POOL WALL (continued)

SAN ONOFRE--UNIT 2 4.0-100-13 Rev. 2 09/27/07

Fuel Storage Patterns for Region II Racks LCS 4.0. 100 4.0 DESIGN FEATURES (continued)

Table 11-3 REGION II Checkerboard Storage Category 11-3 Fuel (Checkerboard Partner For Category 11-4 Fuel)

Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cooling Cool ing Cool ing Cooling Cooling 5.00 41.18 37.27 35.18 33.93 33.12 4.50 36..34 32.87 31.01 29.88 29.15 4.00 31.29 28.31 26.69 25.70 25.06 3.00 20.32 18.50 17.47 16.84 16.42 2.00 7.81 7.25 6.91 6.71 6.58 1.87 5.90 5.53 5.30 5.17 5.09 1.56 0.00 0.00 0.00 0.00 0.00 Category 11-4 Fuel (Checkerboard Partner For Category 11-3 Fuel)

Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cooling Cooling Cooling Cooling Cooling 5.00 75.42 61.90 56.85 54. 18 52.60 4.50 68.08 56.12 51.65 49.25 47.76 4.00 60.74 50.35 46.44 44.19 42.78 3.00 46.06 38.80 35.41 33.52 32.31 2.00 31.38 25.71 23.12 21.65 20.71 1.87 29.19 23.83 21.34 19.91 19.08 0.94 0.00 0.00 0.00 0.00 0.00 Category Category 11-4 11-3 Category Category 11-3 11-4 Table 11-4 (continued)

SAN ONOFRE--UNIT 2 4.0-100-14 Rev. 2 09/27/07

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

REGION II Checkerboard Storage Category 11-5 Fuel (Checkerboard Partner For Category 11-6 Fuel)

Initial Minimum Burnup (GWD/MTU)

Enri chment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cool ing Cool ing Cooling Cooling Cooling 5.00 47.50 42.58 40.03 38.53 37.55 4.50 42.40 37.95 35.64 34.26 33.37 4.00 37.10 33.16 31.10 29.86 29.06 3.00 25.64 22.89 21.40 20.52 19.95 2.00 12.29 11.10 10.42 10.01 9.75 1.87 10.24 9.35 8.80 8.46 8.25 1.38 0.00 0.00 0.00 0.00 0.00 Category 11-6 Fuel (Checkerboard Partner For Category 11-5 Fuel)

Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cool ing Cool ing Cooling Cool ing Cooling 5.00 62.37 53.95 50.33 48.25 46.91 4.50 56.21 48.90 45.51 43.56 42.31 4.00 50.04 43.67 40.54 38.73 37. 57 3.00 37.71 32.56 29.97 28.52 27.58 2.00 23.30 19.80 18.13 17.14 16.50 1.87 21.11 18.02 16.42 15.48 14.88 1.08 0.00 0.00 0.00 0.00 0.00 Category Category 11-6 I-5 Category Category 11-5 11-6 (continued)

SAN ONOFRE--UNIT 2 4.0-100-15 Rev. 2 09/27/07 1

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Table 11-5 REGION II Checkerboard Storage Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cool ing Cool ing Cool ing Cooling Cooling 4.80 0.00 0.00 0.00 0.00 0.00 4.80 Empty Fresh (Blocked)

Empty 4.80 (Blocked) Fresh (continued)

SAN ONOFRE--UNIT 2 4.0-100-16 Rev. 2 09/27/07

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Table 11-6 REGION II Category 11-7 Fuel (3 Out Of 4 Pattern)

Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years I 5 Years 20 Years Cool ing Cool ing Cooling Cool ing Cooling 5.00 34.20 31.3 5 29.74 2 8.76 28.12 4.50 29.67 27.2 '1 25.82 2 4.97 24.41 4.00 24.94 22.9 '2 21.75 2 1.05 20.59 3.00 14.79 13.7 '6 13.13 12.73 12.47 2.00 3.16 3.0 0 2.90 2.83 2.79 1.87 1.21 1.1 4 1.09 1.06 1.04 1.80 0.00 0.0 0 0.00 0.00 0.00 Category Empty 11-7 (Blocked)

Category Category 11-7 11-7 (continued)

SAN ONOFRE--UNIT 2 4.0-100-17 Rev. 2 09/27/07

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Table 11-7 REGION II Category 11-8 Fuel (Fuel With 5 GT-Inserts)

(Unrestricted Storage)

Initial Minimum Burnup (GWD/MTU)

Enrichment (W/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cool i ng Cool ing Cooling Cooling Cooling 5.00 37.68 34.53 32.72 31.61 30.88 4.50 32.61 29.90 28.33 27.36 26.72 4.00 27.33 25.10 23.78 22.97 22A43 3.00 15.86 14.76 14.06 13.61 13.32 2.00 2.04 1.97 1.89 1.84 1.81 1.90 0.00 0.00 0.00 0.00 0.00 Category Category 11-8 11-8 Category Category 11-8 11-8 Note: Category II-1, 11-8, 11-9, and 11-15 may be stored together with no restrictions.

(continued)

SAN ONOFRE--UNIT 2 4.0-100-18 Rev. 2 09/27/07

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Table 11-8 REGION II Category 11-9 Fuel (Fuel With 3 GT-Inserts)

(Unrestricted Storage)

Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cooling Cooling Cooling Cooling Cooling 5.00 44.16 39.95 37.68 36.31 35.42 4.50 38.99 35.25 33.22 31.99 31.18 4.00 33.61 30.38 28.60 27.52 26.81 3.00 21.92 19.86 18.72 18.01 17.56 2.00 8.28 7.72 7.34 7.11 6.96 1.87 6.18 5.83 5.58 5.43 5.34 1.59 0.00 0.00 0.00 0.00 0.00 Category Category 11-9 11-9 Category Category 11-9 11-9 Note: Category 11-1, 11-8, 11-9, and 11-15 may be stored together 'with no restrictions.

(continued)

SAN ONOFRE--UNIT 2 4.0-100-19 Rev. 2 09127107

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Table 11-9 REGION II Category 11-I0 Fuel (Filler Assembly With 5 Guide Tube Inserts)

Initial Minimum Burnup (GWD/MTU)

(w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cool ing Cool ing Cooling Cooling Cooling 5.00 80.09 65.66 60.12 57.45 55.68 4.50 72.13 59.43 54.55 52.02 50.33 4.00 64.18 53.19 48.98 46..58 44.98 3.00 48.27 40.72 37.16 35.03 33.75 2.00 32.35 26.59 23,79 22.25 21.25 1.03 0.00 0.00 0.00 0.00 0.00 Category Category Category 11-10 11-10 11-10 (GT-Inserts) (GT-Inserts) (GT-Inserts)

Category 4 . 80 Category 11-10 Fresh 11-10 (GT-Inserts) (GT-Inserts)

Category Category Category 11-10 11-10 11-10 (GT-Inserts) (GT-Inserts) (GT-Inserts)

(continued)

SAN ONOFRE--UNIT 2 4.0-100-20 Rev. 2 09/27/07 1

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Table 11-10 REGION II Category Il-11 Fuel (Filler Assembly With 5 Guide Tube Inserts)

Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cooling Cooling Cooling Cooling Cool i ng 5.00 47.04 42.52 40.05 38.57 37.60 4.50 41.62 37.58 35.36 34.02 33.14 4.00 35.97 32.46 30.50 29.32 28.54 3.00 23.70 21.42 20.09 19.31 18.79 2.00 9.17 8.54 8.09 7.81 7.62 1.59 0.00 0.00 0.00 0.00 0.00 Category Category Category (GT-Inserts) (GT-lnserts) (GT-Inserts)

Category 4.80 Category I-11 Fresh ii-11 (GT-inserts) 5 Inserts (GT-Inserts)

Category Category Category II-I1 II-11 11-1I.

(GT-lnserts) (GT-Inserts) (GT-Inserts)

(conti nued)

SAN ONOFRE--UNIT 2 4.0-100-21 Rev. 2 09/27/07

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Table II-11 REGION II Category 11-12 Fuel (Filler Assembly With 3 GT-Inserts)

Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cooling Cool ing Cool ing Cool ing Cooling 5.00 54.33 48.48 45.46 43.67 42.51 4.50 48.81 43.45 40.67 39.02 37.95 4.00 43.07 38.24 35.72 34.22 33.26 3.00 30.65 27.11 25.18 24.05 23.33 2.00 16.01 14.23 13.22 12.62 12.22 1.87 13.82 12.35 11.47 10.94 10.60 1.32 0.00 0.00 0.00 0.00 0.00 Category Category Category 11i12 11-12 11-12 (GT-Inserts) (GT-Inserts) (GT-Inserts)

Category 4.80 Category 11-12 Fresh 11-12 (GT-Inserts) 5 Inserts (GT-Inserts)

Category Category Category 11-12 11-12 11-12 (GT-Inserts) (GT-Inserts) (GT-Inserts)

(conti nued)

SAN ONOFRE--UNIT 2 4.0-100-22 Rev. 2 09/27/07

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Table 11-12 REGION II Category 11-13 Fuel (Filler Assembly With No GT-Inserts)

Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cooling Cooling Cooling Cooling Cooling 5.00 64.24 55.51 51.59 49.41 48.03 4.50 57.99 50.23 46.73 44.67 43.38 4.00 51.75 44. 94 41.71 39.79 38.59 3.00 39.25 33.75 31.05 29.48 28.50 2.00 24.76 20.95 19.07 18.01 17.33 1.87 22.64 19.10 17.38 16.37 15.72 1.05 0.00 0.00 0.00 0.00 0.00 Category Category Category 11-13 11-13 11-13 4.80 Category Category 11-13 Fresh 11-13 5 Inserts Category Category Category 11-13 11-13 11-13 (conti nued)

SAN ONOFRE--UNIT 2 4.0-100-23 Rev. 2 09/27/07 1

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Table 11-13 REGION II Category 11-14 Fuel (4.80 w/o Assembly Depleted to 18.0 GWD/MTU)

Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cool ing Cool ing Cooling Cooling Cooling 5.00 19.59 18.61 17.96 17.54 17.27 4.50 15.93 15.17 14.68 14.36 14.15 4.00 12.18 11.64 11.29 11.07 10.93 3.00 4.28 4.12 4.05 4.00 3.98 2.51 0.00 0.00 0.00 0.00 0.00 Category 11-13 Fuel (Filler Assembly For Category 11-14 Fuel)

Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o) 8 Years 5 Years 10 Years 15 Years 20 Years Cooling Cool ing Cooling Cooling Cooling 5.00 64.24 55.51 51.59 49.41 48.03 4.50 57.99 50.23 46.73 44.67 43.38 4.00 51.75 44.94 41.71 39.79 38.59 3.00 39.25 33.75 31.05 29.48 28.50 2.00 24.76 20.95 19.07 18.01 17.33 1.87 22.64 19.10 17.38 16.37 15.72 1.05 0.00 0.00 0.00 0.00 0.00 Category Category Category 11-13 11-13 11-13 Category Category Category 11-13 11-14 11-13 Category Category Category 11-13 11-13 11-13 (continued)

SAN ONOFRE--UNIT 2 4.0-100-24 Rev. 2 09/27/07 1

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Table 11-14 REGION II Category 11-14 Fuel (4.80 w/o Assembly Depleted to 18.0 GWD/MTU)

Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cool i ng Cooling Cooling Cooling Cooling 5.00 19.59 18.61 17.96 17.54 17.27 4.50 15.93 15.17 14.68 14.36 14.15 4.00 12.18 11.64 11.29 11.07 10.93 3.00 4.28 4.12 4.05 4.00 3.98 2.51 0.00 0.00 0.00 0.00 0.00 Category 1I-11 Fuel (Filler Assembly With 5 Guide Tube Inserts)

Initial Minimum Burnup (GWD/MTU)

  • Enri chment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cooling Cooling Cool ing Cooling Cooling 5.00 47.04 42.52 40.05 38.57 37.60 4.50 41.62 37.58 35.36 34.02 33.14 4.00 35.97 32.46 30.50 29.32 28.54 3.00 23.70 21.42 20.09 19.31 18.79 2.00 9.17 8.54 8.09 7.81 7.62 1.59 0.00 0.00 0.00 0.00 0.00 Category Category Category 11-11 11-11 11-11 (5 Inserts) (5 Inserts) (5 Inserts)

Category Category Category Il-11 II-1I (5 Inserts) 11-14 (5 Inserts)

Category Category Category II-]1 11-11 II-11 (5 Inserts) (5 Inserts) (5 Inserts)

(continued)

SAN ONOFRE--UNIT 2 4.0-100-25 Rev . 2 09/27/07

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURE.S (continued)

Table 11-15 REGION II Category 11-15 Fuel (Fuel With 5 Finger Full Length CEA)

(Unrestricted Storage)

Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cooling Cooling Cool ing Cooling Cooling 5.00 29.24 27.24 26.00 25.22 24.70 4.50 24.44 22.84 21.81 21.17 20.75 4.00 19.41 18.26 17.49 17.00 16.68 3.00 8.83 8.47 8.19 8.02 7.90 2.30 0.00 0.00 0.00 0.00 0.00 Category Category 11-15 11-15 Category Category 11-15 11-15 Note: Category 1I-1, 11-8, II-9, and 11-15 may be stored together with no restrictions.

(continued)

SAN ONOFRE--UNIT 2 4.0-100-26 Rev. 2 09/27/07 1

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure I-1 REGION I MINIMUM BURNUP FOR CATEGORY 1-1 FUEL 25 c320 CD rn-

ý1 5 0

2.0 2.5 3.0 3.5 4.0. 4.5 5.0 Initial U-235 Enrichment (w/o)

+ 0 Year.e- 5 Yearc-r 10 Yeafa- 15 Yea.-- 20 Years (continued)

SAN ONOFRE--UNIT 2 4.0-100-27 Rev. 2 09/27/07

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 1-2 REGION I MINIMUM BURNUP FOR CATEGORY 1-2 FUEL 15 10 ... leR gin ... _cepa E

Q)

W) 5-Unacceptable Region 3.0 3.5" 4.0 4.5 5.0 Initial U-235 Enrichment (w/o)

G 0 Years e 5 Years 1;z 10 Years 6 15 Years H 20 Years (continued)

SAN ONOFRE--UNIT 2 4.0-100-28 Rev. 2 09/27/07 1

Fuel Storage Patterns for Region I Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 1-3 REGION I MINIMUM BURNUP FOR CATEGORY 1-3 FUEL (conti nued)

SAN ONOFRE--UNIT 2 4.0-100-29 Rev. 2 09/27/07 1

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 1-4 REGION I MINIMUM BURNUP FOR CATEGORY 1-4 FUEL 20 ..-- ........... ...-I A cceptable R egio n ---------......

15 .0 2.5 3 3._._ .

E t 10)

Unacceptable Region I

2.0 2.5 3.0 3.5 4.0 4.55. 5.0 Initial U-235 Enrichment (w/Q)

E 0 Years -e-- 5 Years svz 10 Years &-, 15 Years -- 20 Years (continued)

SAN ONOFRE--UNIT 2 4.0-100-30 Rev . 2 09/27/07 1

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 1-5 REGION I MINIMUM BURNUP FOR CATEGORY I-5 FUEL 35 30 ------- 1-.-------

25 -

AcceptbeRgo S20 T: 15__

E (D)

Di Unacceptable 5Region 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Initial U-235 Enrichment (w/o)

-9.- 0 Years -e 5 Years - 10 Years - 15 Years x 20 Years (continued)

SAN ONOFRE--UNIT 2 4.0-100-31 Rev. 2 09/27/07 1

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 1-6 REGION I MINIMUM BURNUP FOR CATEGORY 1-6 FUEL 20 O 15 . Acceptable Region 5 ..... Unacceptable Region 0- ____--____

2.5 3.0 3.5 4.0 4.5 5.0 Initial U-235 Enrichment (w/o)

Eq 0 Years - 5 Years 1;z 10 Years 6 15 Years ER 20 Years (continued)

SAN ONOFRE--UNIT 2 4.0-100-32 Rev. 2 09127107

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 1-7 REGION I Boundary Between Unrestricted Storage And Checkerboard Storage Interface I-I I-4 I-I 1-i I-1 I-1 1-1 I-I I-I I-I I-I I-I I-I I-I I-I I- I-1 I-1 I-4 I-6 I-4 1-1 I-1 I-i II II Interface Note: (1) A row of empty cells can be used at the interface to separate the configurations.

(2) It is acceptable to replace an assembly with an empty cell.

(continued)

SAN ONOFRE--UNIT 2 4.0-100-33 Rev. 2 09/27/07 1

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 1-8 REGION I Boundary Between Unrestricted Storage And I Out Of 4 Storage I-I I-I 1-1 I-I I-I I-I I-i I-i 1-1 1-1 I-i I-i I-i I-i I-I I-i I-I I-I 1-3 1-3 1-3 I-I I-I I-I 1-3 4.80 1-3 I-i I-I I-1 1-3 1-3 1-3 I-i I-i I-I II II Interface Note: (1) A row of empty cells can be used at the interface to separate the configurations.

(2) It is acceptable to replace an assembly with an empty cell.

(continued)

SAN ONOFRE--UNIT 2 4.0-100-34 Rev. 2 09/27/07 -

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 1-9 REGION I Boundary Between Checkerboard Storage And I Out Of 4 Storage 4.80 Empty 4.80 Empty 4.80 Empty Empty 4.80 Empty 4.80 Empty 4.80 4.80 Empty 4.80 Empty 4.80 Empty, Empty 1-3 Empty 4.80 Empty 4.80 1-3 4.80 1-3 Empty 4.80 Empty 1-3 1-3 Empty 4.80 Empty 4.80 II II Interface Interface Note: (1) A row of empty cells can be used at the interface to separate the configurations.

(2) It is acceptable to replace an assembly with an empty cell.

(continued)

SAN ONOFRE--UNIT 2 4.0-100-35 Rev. 2 09/27/07 [

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure I-I REGION II MINIMUM BURNUP FOR CATEGORY 1I-i FUEL 60

-50 (40 m30 E

a)

W20 u-I0 0

2 3 4 5 Initial U-235 Enrichment (w/o) 0 Years 5 Years - 10 Years -ý 15 Years - 20 Years (continued)

SAN ONOFRE--UNIT 2 4.0-100-36 Rev. 2 09/27/07 1

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure II-2 REGION II MINIMUM BURNUP FOR CATEGORY 11-2 FUEL 40 0*30-(D 00 2 E

E (0

0) 1.5 2 2.5 3 3.5 4 4.5 5 Initial U-235 Enrichment (w/o)

E 0 Years 5 Years 10 Years -F 15 Years iz 20 Years (continued)

SAN ONOFRE--UNIT 2 4.0-100-37 Rev. 2 09/27/07 1

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 11-3 REGION II MINIMUM BURNUP FOR CATEGORY. II-3 FUEL 50 E40-S30 10-0--

1.5 2 2.5 3 3.5 4 4.5 5 Initial U-235 Enrichment (w/o) 0 Years e 5 Years -e*- 10 Years - 15 Years ii 20 Years (continued)

SAN ONOFRE--UNIT 2 4.0-100-38 Rev. 2 09/27/07 1

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 11-4 REGION 11 MINIMUM BURNUP FOR CATEGORY 11-4 FUEL 80 O 60 CL m40 E

0) 2 3 4 5 Initial U-235 Enrichment (w/o)

EE 0 Years 5 Years - -&- 10 Years - 15 Years iý 20 Years (conti nued)

SAN ONOFRE--UNIT 2 4.0-100-39 Rev. 2 09/27/07

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 11-5 REGION II MINIMUM BURNUP FOR CATEGORY 11-5 FUEL 50 E40-0-

-330

(.9 E 20 Q) 0 0

1 2 3 4 5 Initial .U-235 Enrichment (w/o)

-~--OYears 5 Years 10Years 10-. 15 Years - 20 Years (continued)

SAN ONOFRE--UNIT 2 4.0-100-40 Rev. 2 09/27/07

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 11-6 REGION II MINIMUM BURNUP FOR CATEGORY 11-6 FUEL 70 60 50-CD 40 E 30 Z

< 20 10 0-1 2 3 4 5 Initial U-235 Enrichment (w/o)

Eý 0 Years e- 5 Years ---. 10 Years

  • 15 Years - 20 Years (continued)

SAN ONOFRE--UNIT 2 4.0-100-41 Rev. 2 09/27/07 1

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 11-7 REGION I1 MINIMUM BURNUP FOR CATEGORY 11-7 FUEL 35 30 Zý25-c 20o Z 15-E a)

<10 LL 5--

0--

1.5 2 2.5 3 3.5 4 4.5 5 Initial U-235 Enrichment (w/o)

-=- 0 Years E- 5 Years -e- 10 Years -ý; 15 Years iE 20 Years (continued)

SAN ONOFRE--UNIT 2 4.0-100-42 Rev. 2 09/27/07,

Fuel Storage Patterns for Region II Racks LCS 4.0.I00 4.0 DESIGN FEATURES (continued)

Figure 11-8 REGION 11 MINIMUM BURNUP FOR CATEGORY 11-8 FUEL 40 o30

(_

-n E

m 20 E

ai)

"*10.

LL O0 1.5 2 2.5 3 3.5 4 4.5 5 Initial U-235 Enrichment (w/o)

Eý 0 Years -e- 5 Years --- 10 Years 15 Years Eý 20 Years (continued)

SAN ONOFRE--UNIT 2 4.0-100-43 Rev . 2 09/27/07

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 11-9 REGION II MINIMUM BURNUP FOR CATEGORY 11-9 FUEL 50 iF40 3o E 20 (n

0 LL 10 0

1.5 2 2.5 3 3.5 4 4.5 5 Initial U-235 Enrichment (w/o)

-ý- 0 Years -e-- 5 Years lOYears 0 -- 'v 155Years Z- 20 Years (continued)

SAN ONOFRE--UNIT 2 4.0-100-44 Rev. 2 09127107 1

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 1.1-10 REGION II MINIMUM BURNUP FOR CATEGORY 11-10 FUEL 100 80 E 60 r)

- I co) 40 E,

Q) 20:

0 2 3 4 5 Initial U-235 Enrichment (w/o)

SOYears 55Years -4 10 Years 7 15 Years -- 20 Years (continued)

SAN ONOFRE--UNIT 2 4.0-100-45 Rev. 2 09/27/07 1

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 11-11 REGION II MINIMUM BURNUP FOR CATEGORY 11-11 FUEL 50

-40

(_9

.3:

E 20 LL 10-1.5 2 2.5 3 3.5 4 4.5 5 Initial U-235 Enrichment (w/o)

-E- 0 Years -ý- 5 Years --- 10 Years  ;ý- 15 Years - 20 Years (continued)

SAN ONOFRE--UNIT 2 4.0-100-46 Rev. 2 09/27/07

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 11-12 REGION II MINIMUM BURNUP FOR CATEGORY 11-12 FUEL 60 50 (D 40 CL_

E m30 E

0)

  • 20 tL 10.

0 S2 3 4 5 Initial U-235 Enrichment (w/o) 0 Years 5 Years - 10Years -P-10- 15 Years Eý 20 Years (conti nued)

SAN ONOFRE--UNIT. 2 4.0-100-47 Rev. 2 09/27/07 1

Fuel Storage Patterns for Region II Racks

  • LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 11-13 REGION II MINIMUM BURNUP FOR CATEGORY 11-13 FUEL 70 60 E

3:50 40 co 30.

E Uf)

< 20-U-

10-0--

1 2 3 4 5 Initial U-235 Enrichment (w/o) 0 Years 5 Years - 10 Years 15 Years - 20 Years (continued)

SAN ONOFRE--UNIT 2 4.0-100-48 Rev. 2 09/27/07

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 11-14 REGION II MINIMUM BURNUP FOR CATEGORY 11-14 FUEL 20 015 CD 10-*

2!,

C')

LL 2.5 3 3.5 4 4.5 5 Initial U-235 Enrichment (w/o)

Eý 0 Years e 5 Years - 10 Years -;- 15 Years iE 20 Years (continued)

SAN ONOFRE--UNIT 2 4.0-100--49 Rev. 2 09/27/07 1

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 11-15 REGION. II MINIMUM BURNUP FOR CATEGORY 11-15 FUEL 30

-25 CD20 Co 15 E

S10-0) 2.2 2.7 3.2 3.7 4.2 4.7 Initial U-235 Enrichment (w/o) 0 Years O- 5 Years --e1- 10Years -r- 15 Years Ei 20 Years (continued)

SAN ONOFRE--UNIT 2 4.0-100-50 Rev. 2 09/27/07

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 11-16 REGION II Boundary Between Unrestricted Storage And Checkerboard Storage II-I II-I II-I II-i II-i II-i Il-I Il-I II-i 1I-I II-I II-I Il-1 lI-i II-1 II-1 II-1 lI-i 1I-i Blocked 1I-i 11-1 11-i Il-I Blocked 4.80 Blocked II-I II-1 II-I 4.80 Blocked I1-I I-1 II-1 1I-I Ii I!

Interface 11-1 1I-I 11-1 1I-1 II-i II-i Il-i II-1 II-1 Il-1 II-i TI-1 Il-1 II-I II-1 II-1 II-1 1I-1 II-I 1I-4 11-I II-I Il-I TI-I 11-4 11-3 11-4 11-1 1I-I TI-1 11-3 11-4 1I-1 II-i 11-1 11-1 II II Interface Note: (1) A row of empty cells can be used at the interface to separate the configurations.

(2) It is acceptable to replace an assembly with an empty cell.

(continued)

SAN ONOFRE--UNIT 2 4.0-100-51 Rev. 2 09/27/07

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 11-17 REGION I1 Boundary Between Unrestricted Storage And 3 Out Of 4 Storage II-1 II- I-i 11 -1 I-I IIi II-1 Il-1 I- II-1* 11-1 II- II-i 11-1 Il-I 11-I 11-I II1-I IL-I 11-I Blocked II-1 Blocked II-1 II-i II-I 11-7 11-7 11-I IT-I 1I-I 11-1 Blocked 11-7 Blocked 11-1 IT-I 11-I Interface Note: (1) A row of empty cells can be used at the interface to separate the configurations.

(2) It is acceptable to replace an assembly with an empty cell.

(continued)

SAN ONOFRE--UNIT 2 4.0-100-52 Rev. 2 09127107

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 11-18 REGION I1 Boundary Between Checkerboard Storage And 3 Out Of 4 Storage 11-7 Blocked 11-7 Blocked 11-7 Blocked 11-7 .11-7 11-7 11-7 11-7 11-7 11-7 Blocked 11-7 Blocked 11-7 Blocked Blocked 11-7 Blocked 11-7 11-7 11-7 4.80 Blocked 11-7 Blocked 11-7 Blocked Blocked 4.80 Blocked 11-7 II-7 11-7 II II Interface Note: (1) A row of empty cells can be used at the interface to separate the configurations.

(2) It is acceptable to replace an assembly with an empty cell.

(continued)

SAN ONOFRE--UNIT 2 4.0-100-53 Rev. 2 09/27/07 1

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 11-19 REGION 11 Boundary Between I-Out-Of-9 Storage And Unrestricted Storage II-I T1-i fI-I 11-I . 1-I II-I 11-I 11-i lI-I I1-I Il-1 11-I II-i Il-I 11-I 11-I II-I Il-I Filler Filler Filler 11-i 11-1 Il-i Filler A Filler 11-I 1I-I 11-I Filler Filler Filler fa-I Ic-i Il-i Interface Where: (1) If A = 4.80 w/o + 0 Inserts, Filler = Category 11-10 (2) If A = 4.80 w/o + 5 Inserts, Filler = Category TI-11 (3) If A = 4.80 w/o + 5 Inserts, Filler = Category 11-12 (4) If A = 4.80 w/o + 5 Inserts, Filler = Category 11-13 (5) If A = Category 11-14, Filler = Category 11-13 (6) If A = Category 11-14, Filler = Category I1-11 (conti nued)

SAN ONOFRE--UNIT 2 4.0-100-54 Rev. 2 09/27/07 1

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 11-20 REGION I1 Boundary Between 1-Out-Of-9 Storage And Checkerboard Storage 11-4 11-3 11-4 11-3 11-4 11-3 11-3 11-4 11-3 11-4 11-3 11-4 11-4 11-3 11-4 11-3 11-4 11-3 Filler Filler Filler 11-4 11-3 11-4 Filler A Filler 11-3 11-4 11-3 Filler Filler Filler 11-4 H1-3 11-4 Interface Where: (1) If A = 4.80 w/o + 0 Inserts, Filler = Category 11-10 (2) If A = 4.80 w/o + 5 Inserts, Filler = Category II-11 (3) If A = 4.80 w/o + 5 Inserts, Filler = Category 11-12 (4) If A = 4.80 w/o + 5 Inserts, Filler = Category 11-13 (5) If A = Category 11-14, Filler = Category 11-13 (6) If A = Category 11-14, Filler = Category 11-11 (continued)

SAN ONOFRE--UNIT 2 4.0-100-55 Rev. 2 09/27/07 1

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 11-21 REGION II Boundary Between 1-Out-Of-9 Storage And Checkerboard Storage Blocked 4.80 Blocked 4.80 Blocked 4.80 4.80 Blocked 4.80 Blocked 4.80 Blocked Blocked 4.80 Blocked 4.80 Blocked 4.80 Filler Blocked Filler Blocked 4.80 Blocked Filler A Blocked 4.80 Blocked 4.80 Filler Filler Filler Blocked 4.80 Blocked Interface Where: (1) If A = 4.80 w/o + 0 Inserts, Filler = Category 11-10' (2) If A = 4.80 w/o + 5 Inserts, Filler = Category 11-11 (3) If A = 4.80 w/o + 5 Inserts, Filler = Category 11-12 (4) If A = 4.80 w/o + 5 Inserts, Filler = Category 11-13 (5) If A = Category 11-14, Filler = Category 11-13 (6) If A = Category 11-14, Filler = Category 11-11 (continued)

SAN ONOFRE--UNIT 2 4.0-100-56 Rev. 2 09/27/07 1

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 11-22 REGION 11 Boundary Between 1-Out-Of-9 Storage And 3-Out-Of-4 Storage 11-7 Blocked 11-7 Blocked 11-7 Blocked 11-7 11-7 11-7 11-7 11-7 11-7 11-7 Blocked 11-7 Blocked 11-7 Blocked Filler Filler Filler 11-7 11-7 11-7 Filler A Filler Blocked 11-7 Blocked Filler Filler Filler 11-7 11-7 11-7 Interface Where: (1) If A 4.80 w/o + 0 Inserts, Filler Category 11-10 (2) If A 4.80 w/o + 5 Inserts, Filler Category 1I-11 (3) If A 4.80 w/o + 5 Inserts, Filler Category 11-12 (4) If A 4.80 w/o + 5 Inserts, Filler Category 11-13 (5) If A Category 11-14, Filler Category 11-13 (6) If A Category 11-14, Filler Category I11-I (continued)

SAN ONOFRE--UNIT 2 4.0-100-57 Rev . 2 09/27/07

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 11-23 Orientation Of 3 Guide Tube Inserts Fuel Assembly yyy <--- Serial yI Number Y

00 xx 00 xx xx xx xx 00 xx 00 XX = Guide Tube With Insert xx 00 = Empty Guide Tube 00 (continued)

SAN ONOFRE--UNIT 2 4.0-100-58 Rev. 2 09/27/07 1

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 11-24 SONGS UNITS 2 AND 3 FUEL ASSEMBLY WITH 40 ERBIA RODS 40 Erbia Rods D- High Enriched Fuel Rod F Low Enriched Fuel Rod II Erbia Fuel Rod (continued)

SAN ONOFRE--UNIT 2 4.0-100-59 Rev. 2 09/27/07

Fuel Storage Patterns for Region II Racks LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 11-25 SONGS UNITS 2 AND 3 FUEL ASSEMBLY WITH 80 ERBIA RODS 80 Erbia Rods D High Enriched Fuel Rod Z Low Enriched Fuel Rod E] Erbia Fuel Rod (continued)

SAN ONOFRE--UNIT 2 4.0-100-60 Rev. 2 09/27/07 1

Fuel Storage Patterns LCS 4.0.100 B LCS 4.0.100 Fuel Storage Patterns BASES BACKGROUND The spent fuel storage facility is designed to store either new (nonirradiated) nuclear fuel assemblies, or burned (irradiated) fuel assemblies in a vertical configuration underwater. The storage pool is sized to store 1542 fuel assemblies. Two types/sizes of spent fuel storage racks are

  • used (Region I and Region II). The two Region I racks each contain 156 storage locations each spaced 10.40 inches on center in a 12x13 array. Four Region II storage racks each contain 210 storage locations in a 14x15 array. The remaining two Region II racks each contain 195 locations in a 13x15 array. All Region II locations are spaced 8.85 inches on center.

As described in LCS 4.0.100, "Fuel Storage Patterns" fuel assemblies are stored in the spent fuel racks in accordance with criteria based on initial enrichment, discharge burnup, and cooling time (plutonium decay).

Additionally, LCS 4.0.100 allows the following storage options:

2x2 storage patterns, 3x3 storage patterns, credit for erbia in fresh assemblies, inserted CEAs, and borated stainless steel guide tube inserts (GT-Inserts).

The effect of these storage options is to reduce the required discharge burnup of irradiated assemblies and add flexibility in storing fresh assemblies containing erbia.

Finally, credit for boron is taken to maintain Keff

  • 0.95.

The storage options allowed by LCS 4.0.100 and credit for soluble boron are needed because the boraflex is assumed to be completely absent. Boraflex erosion/dissolution is an industry problem, and SONGS Units 2 and 3 are affected.

Taking no credit for boraflex for SONGS Units 2 and 3 (conti nued)

SAN ONOFRE--UNIT 2 4.0-100-61 Rev. 2 09/27/071

Fuel Storage Patterns LCS 4.0.100 BASES (continued)

BACKGROUND eliminates any boraflex concerns and monitoring programs to (continued) ensure that an adequate amount of boraflex is present will.

not be needed.

APPLICABLE When soluble boron is credited, the following acceptance SAFETY ANALYSIS criteria apply:

(1) Under normal conditions, the 95/95 neutron multiplication factor (Kerf), including all uncertainties, shall be less than 1.0 when flooded with unborated water, and, (2) Under normal and accident conditions, the 95/95 neutron multiplication factor (Keff), including all uncertainties, shall be less than or equal to 0.95 when flooded with borated water.

The storage options allowed by LCS 4.0.100 meet acceptance criterion 1 above. Under normal, non-accident conditions, Keff is less than 1.00 with 0 ppm.

The storage options allowed by LCS4.0.100 meet acceptance criterion 2 above. Under normal, non-accident conditions, the TS 3.7.17 limit for soluble boron concentration of 2000 ppm will ensure that Keff remains less than or equal to 0.95.

The analytical methods used to demonstrate that the storage options allowed by LCS 4.0.100 meet acceptance criteria 1 and 2 are described in the SONGS Spent Fuel Pool Criticality Analysis (Reference 1).

A fuel assembly could be inadvertently loaded into a spent fuel rack location not allowed by LCS 4.0.100 (e.g., an unirradiated fuel assembly or an insufficiently depleted fuel assembly). However, the negative reactivity effect of the soluble boron compensates for the increased reactivity caused by the postulated accident scenario. For this accident condition, the TS 3.7.17 limit for soluble boron concentration of 2000 ppm will ensure that Keff remains less than or equal to 0.95.

(continued)

SAN ONOFRE--UNIT 2 4.0-100-62 Rev. 2 09/27/07 1

Fuel Storage Patterns LCS 4.0.100 BASES (continued)

LCS The placement of fuel assemblies within the spent fuel pool according to LCS 4.0.100 ensures that the Keff of the spent fuel pool will always remain < 1.00 Under normal, non-accident conditions assuming the pool to be flooded with unborated water. The Keff of the spent fuel pool will always remain

  • 0.95 under normal and accident conditions assuming the pool to be flooded with borated water at 2000 ppm.

APPLICABILITY This LCS applies whenever any fuel assembly is stored in the spent fuel pool.

ACTIONS See the Bases for LCO 3.7.18 A SURVEILLANCE See the Bases for SR 3.7.18.1 REQUIREMENTS REFERENCES 1. Spent Fuel Pool Criticality Analysis, (with no Boraflex and Credit for Soluble Boron), Southern California Edison, San Onofre Nuclear Generating Station Units 2 and 3, Revision 2, April 2007.

(continued)

SAN ONOFRE--UNIT 2 4.0-100-63 Rev. 2 09/27/07

SONGS UNIT 3 SINGLE-SIDED Operating License &Technical Specification/Licensee Controlled Specification AMD 205, B08-001, B08-002, L08-001, L08-002 PCN 556 Supp. 2 Revise Unit 3 Operating License by removing pages and inserting the enclosed pages.

The revised pages are identified by the captioned amendment number and/or dates and contain marginal/lines indicating the areas of change. Please direct any questions regarding filing of information to: (949) 368-6972or email CDM Controlled Manuals Desk.

REMOVE: INSERT:

VOLUME 1 VOLUME 1 BEHIND: "Blue Tab" List of Effective Pages BEHIND: "Blue Tab" List of Effective Pages List of Effective Pages 1-12 REV 0 List of Effective Pages 1-12 Rev 1 AMD 207 12/12/07 AMD 207 03/05/08 BEHIND: "Blue Tab" 3.7 Plant Systems BEHIND: "Blue Tab" 3.7 Plant Systems 3.7-30 AMD 116 3.7-30 AMD 205 3.7-32 AMD 120 3.7-32 AMD 205 3.7-33 AMD 120 3.7-33 AMD 205 3.7-34 AMD 120 3.7-34 AMD 205 nothing to pull 3.7-34a AMD 205 (new page) nothing to pull 3.7-34b AMD 205 (new page)

EHIND: "Blue Tab" 4.0 Design Features BEHIND: "Blue Tab" 4.0 Design Features 0-4 AMD 120 4.0-4 AMD 205 nothing to pull 4.0-4 a AMD 205 (new page)

VOLUME 3 VOLUME 3 BEHIND: "Blue Tab" B 3.4 BEHIND: "Blue Tab" B 3.4 B 3.4-75a AMD 116 09/24/98 (deleting page)

BEHIND: "Blue Tab" B 3.7 BEHIND: "Blue Tab" B 3.7 B 3.7-71 AMD 116 04/29/03 B 3.7-71 AMD 116 03/05/08 B 3.7-72 AMD 116 B 3.7-72 AMD 116 03/05/08 B 3.7-73 AMD 116 B 3.7-73 AMD 116 03/05/08 B 3.7-74 AMD 116 04/29/03 B 3.7-74 AMD 116 03/05/08 B 3.7-75 AMD 116 04/29/03 B 3.7-75 AMD 116 03/05/08 nothing to pull B 3.7-75a AMD 116 03/05/08 (new page)

BEHIND: "Blue Tab" B 3.8 BEHIND: "Blue Tab" B 3.8 B 3.8-83 AMD 116 01/11/07 B 3.8-83 AMD 116 03/05/08 LCS BOOK LCS BOOK BEHIND: White Tab List of Effective Pages BEHIND: White Tab List of Effective Pages List of Effective Pages 1-5 REV 0 List of Effective Pages 1-6 REV 1 ilk 12/12/07 03/05/08 N>

Page 1 of 3

SONGS UNIT 3 SINGLE-SIDED Operating License & Technical Specification/Licensee Controlled Specification AMD 205, B08-001, B08-002, L08-001, L08-002 PCN 556 Supp. 2 Revise Unit 3 Operating License by removing pages and inserting the enclosed pages.

The revised pages are identified by the captioned amendment number and/or dates and contain marginal/lines indicating the areas of change. Please direct any questions regarding filing of information to: (949) 368-6972or email CDM Controlled Manuals Desk.

REMOVE: INSERT:

LCS BOOK LCS BOOK BEHIND: "Blue Tab" 3.7 Plant Systems BEHIND: "Blue Tab" . 3.7 Plant Systems 3.7-116-1 REV 3 03/26/01 3.7-116-1 REV 4 03/05/08 3.7-116-2 REV2 03/26/01 3.7-116-2 REV3 03/05/08 BEHIND: "Blue Tab" 4.0 Design Features BEHIND: "Blue Tab" 4.0 Design Features 4.0-100-1 REV 1 12/0,1/97 4.0-100-1 REV 2 09/27/07 4.0-100-2 REV 1 12/01/97 4.0-100-2 REV 2 09/27/07 4.0-100-3 REV 1 12/01/97 4.0-100-3 REV 2 09/27/07 Nothing to pull 4.0-100-4 thru 4.0-100-63 REV 2 09/27/07 (new pages)

Page 2 of 3

SONGS UNIT 3 SINGLE-SIDED Operating License &Technical Specification/Licensee Controlled Specification AMD 205, B08-001, B08-002, L08-001, L08-002 PCN 556 Supp. 2 Revise Unit 3 Operating License by removing pages and inserting the enclosed pages.

The revised pages are identified by the captioned amendment number and/or dates and contain marginal/lines indicating the areas of change. Please direct any questions regarding filing of information to: (949) 368-6972or email CDM Controlled Manuals Desk.

Filing Instructions Reviewed & Approved:

Sigriature/l4lA Date Signature/CDM Processor" Date Page 3 of 3

APPENDIX A TO LICENSE NO. NPF-15 SAN ONOFRE UNIT 3 TECHNICAL SPECIFICATIONS (NUREG-0952)

LIST OF EFFECTIVE PAGES Page No. Volume Amendment/Date ý:Page No. Volume Amendment/Date LOEP-1 207 03/05/08 2.0-1 1 199 LOEP-2 200 01/25/07 2.0-2 1 199 LOEP-3 206 '3.0-1 1 116 LOEP-4 207 3.0-2 1 116 LOEP-4a 159 3.0-3 1 116 LOEP-5 199 12/21/06 :3.0-4 1 177 LOEP-6 191 11/18/05 :13.0-5 1 116 LOEP-7 188 07/19/05 3.1-1 1 191 LOEP-8 200 12/05/06 3.1-2 1 191 LOEP-9 196 09/19/06 3.1-3 1 191 LOEP-1O 204 12/12/07 3.1-4 1 116 LOEP-II 203 03/05/08 3.1-5 1 116 LOEP-12 184 03/05/08 3.1-6 1 116 ii 116 3.1-7 1 191 iii 200 3.1-8 1 191 iv 200 3.1-9 1 116 v 188 3.1-10 1 116 vi 116 3.1-11 126 vii 200 3.1-12 1 191 viii 200 3.1-13 1 116 1.1-1 116 ,3.1-14 1 191 1.1-2 116 3 1-15 1 191 1.1-3 179 3.1-16 1 191 1.1-4 196 3.1-17 1 116 1.1-5 195 3,1-18 1 116 1.1-6 191 '3.1-19 1 116 1.1-7 116 3.1-20 1 116 1.2-1 116 3.1-21 1 154 1.2-2 116 3.1-22 1 166 1.2-3 116 3.1-23 1 116 1.3-1 116 3.1-24 1 116 3.1-25 1 116 1 .3-2 116 1.3-3 116 3.1-26 1 116 3.1-27 1 116 1.3-4 116 3.1-28 1 116 1.3-5 116 3.1-29 1 116 1.3-6 116 3.2-1 1 116 1.3-7 116 3.2-2 1 116 1.3-8 116 3.2-3 1 116 1.3-9 116 3.2-4 1 116 1.3-10 116 3 .2-5 1 116 1.3-11 116 3.2-6 1 116 1.3-12 116 3 .2-7 1 116 1.3-13 116 3.2-8 1 116 1.4-1 116 13.2- 9 1 191 1.4-2 116 3.2-10 ,1 116 1.4-3 116 3.2-11 1 116 1.4-4 116 3.2-12 1 116 3.3-1 1 116 NDMS Revision 1 Page 1 of 12 Amendment 207 03/05/08

APPENDIX A TO LICENSE NO. NPF-15 SAN ONOFRE UNIT 3 TECHNICAL SPECIFICATIONS (NUREG-0952)

LIST OF EFFECTIVE PAGES Page No. Volume Amendment/Date Page No. Volume Amendment/Date 3.3-2 116 3.3-51 1 166 3.3-3 116 3.3-52 1 116 3.3-4 116 3.4-1 1 141 3.3-5 116 3.4-2 1 141 3.3-6 139 3.4-3 1 141 3.3-7 122 3.4-4 1 116 3.3-8 142 3.4-5 1 195 3.3-9 142 3.4-6 I 195 3.3-10 116 3.4-7 1 195 3.3-11 116 3.4-8 1 195 3.3-12 122 3.4-9 .1 195 3.3-13 139 3.4-10 1 195 3.3-14 116 3.4-11 1 195 3.3-15 116 3.4-12 1 195 3.3-16 122 3.4-13 1 116 3.3-17 116 3.4-14 1 188 3.3-18 116 3.4-15 1 116 3.3-19 116 3.4-16 1 166 3.3-20 122 3.4-17 1 166 3.3-21 116 3.4-18 1 195 3.3-22 148 3.4-19 1 166 3.3-23 148 3.4-20 1 116 3 .3-24 148 3.4-21 1 166 3.3-25 148 3.4-22 1 195 3.3-26 116 3.4-23 1 166 3.3-27 116 3.4-24 1 166 3.3-28 116 3.4-25 1 166 3.3-29 122 3.4-26 1 152 3 3-30 116 3.4-27 1 146 3.3-31 116 3.4-28 1 147 3.3-32 116 3.4-29 1 147 3.3-33 116 3.4-30 1 195 3.3-34 187 3.4-31 1 195 3.3-35 121 3.4-32 1 116 3.3-36 121 3.4-33 1 195 3.3-37 121 3.4-34 1 134 3.3-38 121 3.4-35 1 195 3.3-39 121 3.4-36 I 116 3.3-40 166 3.4-37 1 196 3.3-41 151 3.4-38 1 196 3.3-42 200 01/25/07 3.4-39 1 116 3.3-43 200 01/25/07 3.4-40 1 116 3.3-44 116 3.4-41 1 116 3.3-45 185 3.4-42 .1 116 3.3-46 185 3.4-43 I 116 3.3-47 185 3.4-44 1 116 3.3-48 116 3.4-45 1 116 3.3-49 116 3.3-50 116 NDMS Revision 1 Page 2 of 12 Amendment 200 01/25/07

APPENDIX A TO LICENSE NO. NPF-15 SAN ONOFRE UNIT 3 TECHNICAL SPECIFICATIONS (NUREG-0952)

LIST OF EFFECTIVE PAGES Page No. Volume Amendment/Date Page No. Volume Amendment/Date 3.4-46 1 116 3.7-6 116 3.4-47 1 116 3.7-7 116 3.4-48 1 116 3.7-8 116 3.4-49 1 116 3..7-9 116 3.4-50 1 116 3.7-10 116 3.4-51 1 196 3.7-11 155 3.4-52

  • 1 196 3.7-12 116 3.5-1 1 131 3.7-13 116 3.5-2 1 124 3.7-14 182 3.5-3 1 116 3.7-15 139 3.5-4 1 131 3.7-16 153 3.5-5
  • 1 116 3.7-17 116 3.5-6 1 181 3.7-18 116 3.5-7 1 116 3.7-19 116 3.5-8 1 116 3.7-19a 118 3.5-9 1 116 3.7-19b 118 3.5-10 1 116 3 .7-19c 118 3.5-11 1 116 3.7-20 116 3.6-1 1 116 3.7-21 116 3.6-2 1 135 3.7-22 172 3.6-3 1 116 3.7-23 116 3.6-4 1 116 3.7-24 206 3.6-5 1 116 3.7-25 206 3.6-6 1 135 3.7-26 206 3.6-7 1 116 3.7-27 200 01/25/07 3.6-8 1 116 3.7-28 200 01/25/07 3.6-9 1 116 3.7-29 116 3.6-10 1 116 3.7-30 205 3.6-11 1 116 3.7-31 116 3.6-12 1 156 3.7-32 205 3.6-13 1 192 3.7-33 205 3.6-14 1 192 3.7-34 205 3.6-15 1 116 3 .7-34a 205 3.6-16 1 116 3.7-34b 205 3.6-17 1 116 3.7-35 116 3.6-18 1 162 3..8-1 133 3.6-19 1 116 3.8-2 133 3.6-20 1 116 3.8-3 116 3.6-21 1 116 3.8-4 149 3.6-22 1 116 3.8-5 170 3.6-23 1 150 3.8-6 203 3.6-24 1 150 3.8-7 149 3.6-25 1 116 3.8-8 170 3.6-26 1 116 3.8-9 149 3.7-1 1 204 3.8-10 149 3.7-2 1 116 3.8-11 149 3.7-3 1 204 3.8-12 149 3.7-4 1 204 3.8-13 160 3.7-5 1 116 3.8-14 170 NDMS Revision I Page 3 of 12 Amendment 206

APPENDIX A TO LICENSE NO. NPF-15 SAN ONOFRE UNIT 3 TECHNICAL SPECIFICATIONS (NUREG-0952)

LIST OF EFFECTIVE PAGES Page No. Volume Amendment/Date Page No. Volume Amendment/Date 3.8-15 149 5.0-5 199 3.8-16 116 5.0-6 175 3.8-17 116 5.0-7 116 3.8-18 166 5.0-8 199 3.8-19 116 5.0-9 169 3.8-20 203 5.0-10 116 3.8-21 203 5.0-11 161 3.8-22 116 5.0-12 169 3.8-23 116 5.0-13 196 3.8-24 116 5.0-14 196 3.8-25 116 5.0-15 198

.3.8-26 116 5.0-15a 207 3.8-27 166 5.0-16 207 3.8-28 116 5.0-17 200 3.8-29 116 5.0-18 196 3.8-30 116 5.0-19 196 3.8-31 116 5.0-20 196 3.8-32 116 5.0-20a 189 3.8-33 116 5.0-20b 206 3.8-34 116 5.0-20c 206 3.8-35 116 5.0-21 116 3.8-36 166 5.0-22 116 3.8-37 116 5.0-23 186 3.8-38 116 5.0-24 116 3.8-39 116 5.0-25 116 3.8-40 166 5.0-26 191 3.8-41 116 5.0-27 195 3.9-1 116 5.0-27a 195 3.9-2 166 5.0-28 196 3.9-3 116 5.0-29 196 3.9-4 184 5.0-30 188 3.9-5 116 5.0-31 199 3.9-6 166 3.9-6a 166 3.9-7 144 3.9-8 144 3.9-9 166 3.9-9a 144 3.9-10 123 4.0-1 190 4.0-2 116 4.0-3 116 4.0-4 205 4.0-4a 205 4.0-5 120 5.0-1 199 5.0-2 199 5-.0-3 199 5.0-4 199 NDMS Revision I Page 4 of 12 Amendment 207

APPENDIX A TO LICENSE NO. NPF-15 SAN ONOFRE UNIT 3 TECHNICAL SPECIFICATIONS (NUREG-0952)

LIST OF EFFECTIVE PAGES Page No. Vol ume Amendment/Date Bibliographic Data Sheet Appendix B dated Nov. 15, 1982 Environmental Protection Plan dated Nov. 15, 1982 1-1 1 dated Nov. 15, 1982 2-1 1. dated Nov. 15, 1982 2-2 1 dated Nov. 15, 1982 3-1 1 dated Nov. 15, 1982 3-2 1 159 4-1 1 159 4-2 1 dated Nov. 15, 1982 Appendix C 1 dated Nov. 15, 1982 Page 2 1 dated Nov. 15, 1982 Page 3 1 dated Nov. 15, 1982 NDMS Revision 1 Page 4a of 12 Amendment 159

APPENDIX A TO LICENSE NO. NPF-15 SAN ONOFRE UNIT 3 TECHNICAL SPECIFICATIONS (NUREG-0952)

LIST OF EFFECTIVE PAGES Page No. Volume Amendment/Date Page No. Volume Amendment/Date 2.0-1 183 07/19/04 3.1-27 116 2.0-2 116 3.1-28 191 11/18/05 2.0-3 199 12/21/06 3.1-29 191 11/18/05 2.0-3a 183 07/19/04 3.1-30 191 11/18/05 2.0-4 199 12/21/06 3.1-31 116 2.0-5 199 12/21/06 3.1-32 116 05/02/97 2.0-6 116 3.1-33 116 2.0-7 116 3.1-34 116 05/02/97 2.0-8 199 12/21/06 3.1-35 116 2.0-9 199 12/21/06 3.1-36 116 3.0-1 116 3.1-37 191 11/18/05 3.0-2 116 3.1-38 191 11/18/05 3.0-3 116 3.1-39 116 3.0-4 199 12/21/06 3.1-40 116 3.0-5 116 3.1-41 116 3.0-6 116 3.1-42 116 3.0-7 116 3.1-43 191 11/ 18/05 3.0-8 116 3.1-43a 191 11/ 18/05 3.0-9 116 3.1-44 191 11/ 18/05 3.0-10 116 3.1-45 116 3.0-11 116 3.1-46 191 11/ 18/05 3.0-12 116 12/01/98 3.1-47 116 3.0-13 177 10/25/02 3.1-48 116 3.0-14 177 05/08/02 3.1-49 116 3.0-15 177 05/08/02 3.1-50 116 3.1-1 191 11/18/05 3.1-51 116 3.1-2 191 11/18/05 3.1-52 116 3.1-3 191 11/18/05 3.1-53 116 3.1-4 191 11/18/05 3.1-54 116 08/03/01 3.1-5 191 11/18/05 3.1-55 116 08/03/01 3.1-6 191 11/18/05 3.1-56 116 08/03/01 3.1-7 191 11/18/05 3.1-57 116 08/03/01 3.1-8 191 11/18/05 3.1-58 116 08/0 3/01 3.1-9. 191 11/18/05 3.1-58a 116 08/03/ 01 3.1-10 191 11/18/05 3.1-58b 116 08/03 /01 3.1-11 191 11/18/05 3.1-59 191 11/18/05 3.1-12 191 11/18/05 3.1-60 116 11/05/96 3.1-13 116 3.1-61 116 05/03/00 3.1-14 116 3.1-62 166 12 /20/00 3.1-15 191 11/18/05 3.1-63 166 05/2 1/02 3.1-16 116 3.1-63a 166 12/20/00 3.1-17 191 11/18/05 3.1-64 116

,3.1-18 116 3.1-65 116 3.1-19 116 01/03/02 3.1-66 116 3.1-20 116 3.1-67 116 3.1-21 116 01/03/02 3.1-68 116 3.1-22 116 05/30/97 3.1-69 116 3.1-23 116 3.1-70 116 3.1-24 116 3.1-71 116 3.1-25 116 05/02/97 3.1-72 116 3.1-26 116 07/29/99 NDMS Revision I Page 5 of 12 Amendment 199 12/21/06

APPENDIX A TO LICENSE NO. NPF-15 SAN ONOFRE UNIT 3 TECHNICAL SPECIFICATIONS (NUREG-0952)

LIST OF EFFECTIVE PAGES Page No. Volume Amendment/Date Page No. Volume Amendment/Date 3.1-73 116 3.3-2 116 07/17/97 3.1-74 116 3.3-3 116 3.1-75 116 3.3-4 116 3.1-76 116 3.3-5 116 3.1-77 116 05/29/97 3.3-6 116 3.1-78 116 05/29/97 3.3-7 116 3.1-79 116 3.3-8 116 3.1-80 116 3.3-9 116 3.2-1 116 3.3-10 116 3.2-2 116 3.3-11 116 3.2-3 116 3.3-12 116 03/12/99 3.2-4 183 07/19/04 3.3-13 116 3.2-5 116 3.3-14 116 3.2-6 116 3.3-15 116 3.2-7 116 3.3-16 116 07/17/97 3.2-8 116 3.3-17 116 09/16/03 3.2-9 116 3.3-18 116 03/12/99 3.2-10 116 3.3-19 116 3.2-11 116 3.3-20 116 3.2-12 183 07/19/04 3.3-21 116 03/12/99 3.2-13 116 3.3-22 116 03/12/99 3.2-14 116 3.3-23 116 03/12/99 3.2-15 116 3.3-24 116 3.2-16 116 3..3-25 116 12/30/96 3.2-17 116 3.3-26 116 12/30/96 3.2-18 116 3.3-26a 116 12/30/96 3.2-19 183 07/19/04 3.3-27 116 3.2-20 116 3.3-28 116 3.2-21 116 3.3-29 116 3.2-22 116 3.3-30 116 05/29/97 3.2-23 116 3.3-31 116 05/02/97 3.2-24 116 3.3-32 116 03/12/99 3.2-25 116 3.3-33 116 03/12/99 3.2-26 116 3.3-34 116 03/12/99 3.2-27 116 3.3-35 116 03/12/99 3.2-28 116 3.3-36 116 03/12/99 3.2-29 183 07/19/04 3.3-37 179 3.2-30 191 11/18/05 3 .3-37a 179 09/16/03 3.2-31 116 3.3-38 116 3.2-32 116 3.3-39 116 07/17/97 3.2-33 116 3.3-40 116 12/09/98 3.2-34 116 3.3-41 116 12/09/98 3.2-35 116 3.3-42 116 3.2-36 116 3.3-43 116 3.2-37 116 .3.3-44 116 12/30/96 3.2-38 183 07/19/04 3.3-45 116 12/30/96 3.2-39 116 3.3-46 116 12/30/96 3.2-40 116 3.3-47 116 12/30/96 3.2-41 116 3.3-48 116 09/18/98 3.3-1 3.3-49 116 09/18/98 116 NDMS Revision I Page 6 of! 12 Amendment 191 11/18/05

APPENDIX A TO LICENSE NO. NPF-15 SAN ONOFRE UNIT 3 TECHNICAL SPECIFICATIONS (NUREG-0952)

LIST OF EFFECTIVE PAGES Page No. Volume Amendment/Date Page No. Volume Amendment/Date 3.3-50 116 09/18/98 3.3-100 188 07/19/05 3.3-51 116 02/11/02 3.3-101 116 10/06/99 3.3-51a 116 09/18/98 3.3-102 116 10/06/99 3.3-52 116 3.3-103 116 10/06/99 3.3-53 116 07/17/97 3.3-103a 179 3.3-54 116 3.3-103b 148 09/16/03 3.3-55 116 3.3-103c 179 3.3-56 116 3.3-104 116 3.3-57 116 3.3-105 116 3.3-58 116 3.3-106 116 3.3-59 116 3.3-107 116 3.3-60 116 09/18/98 3.3-108 116 3.3-61 116 09/18/98 3.3-109 116 3.3-62 116 09/18/98 3.3-110 116 3.3-63 116 3.3-111 116 3.3-64 116 07/17/97 3.3-112 *116 3.3-65 116 3.3-113 116 3.3-66 116 3.3-114 116 3.3-67 116 3.3-115 116 3.3-68 116 3.3-116 116 3.3-69 116 3.3-117 116 3.3-70 116 3.3-118 116 3.3-71 116 3.3-119 116 12/30/96 3.3-72 116 12/30/96 3.3-120 116 12/30/96 3.3-73 116 12/30/96 3.3-121 116 12/30/96 3.3-74 116 12/30/96 3.3-122 116 12/30/96 3.3-75 116 05/28/97 3.3-123 116 05/28/97 3.3-76 116 12/30/96 3.3-124 116 05/28/97 3 .3-77 116 07/17/97 3.3-125 116 05/28/97 3.3-78 116 3.3-126 116 3.3-79 116 3.3-127 116 3.3-80 116 3.3-128 116 3.3-81 116 3.3-129 116 09/06/00 3.3-82 116 3.3-130 116 3.3-83 116 3.3-131 116 09/06/00 3 .3-84 116 3.3-132 116 05/29/97 3.3-85 116 3.3-133 116 07/13/99 3.3-86 116 3.3-134 165 12/14/00 3.3-87 116 02/24/99 3.3-135 116 05/28/97 3.3-88 116 07/17/97 3.3-136 116 06/09/00 3.3-89 116 3.3-137 116 o5/28/97 3.3-90 116 3.3-138 116 05/28/97 3.3-91 116 3.3-139 116 05/28/97 3.3-92 116 3.3-140 116 05/28/97 3.3-93 116 3.3-141 116 05/28/97 3.3-94 116 3.3-142 116 05/28/97 3.3-95 116 10/06/99 3.3-143 116 05/28/97 3.3-96 116 10/06/99 3.3-144 116 05/28/97 3.3-97 116 10/06/99 3.3-145 116 06/27/97 3.3-98 116 07/18/01 3.3-146 116 03/19/98 3.3-99 116 10/06/99 NDMS Revision 1 Page 7 of 12 Amendment 188 07/19/05

APPENDIX A TO LICENSE NO. NPF-15 SAN ONOFRE UNIT 3 TECHNICAL SPECIFICATIONS (NUREG-0952)

LIST OF EFFECTIVE PAGES Page No. Volume Amendment/Date Page No. Volume Amendment/Date 3.3-147 116 06/27/97 3.4-12 116 3.3-148 166 12/20/00 3.4-13 116 3.3-149 166 12/20/00 3.4-14 116 3.3-150 116 08/20/01 3.4-15 195 3.3-151 116 06/27/97 3.4-16 195 3.3-152 200 12/05/06 3.4-17 188 07/19/05 3.3-153 200 12/05/06 3.4-18 ,188 07/19/05 3.3-154 200 12/05/06 3.4-19 116 3.3-155 200 12/05/06 3.4-20 188 07/19/05 3.3-156 200 12/05/06 3.4-21 188 07/19/05 3.3-157 200 12/05/06 3.4-22 116 3.3-158 116 12/17/98 3.4-23 116 3.3-159 116 06/08/00 3.4-24 196 3.3-160 116 06/23/99 3.4-25 116 3.3-161 116 05/30/97 3.4-26 116 3.3-162 116 05/30/97 3.4-27 116 3 .3-163 119 05/30/97 3.4-28 196 3.3-164 116 05/30/97 3.4-29 166 12/20/00 3.3-165 116 05/30/97 3.4-30 166 12/20/00 3.3-166 185 04/25/05 3.4-31 116 3.3-167 116 05/30/97 3.4-32 196 3.3-168 116 12/02/99 3.4-33 116 3.3-169 116 05/30/97 3.4-34 166 3.3-170 116 3.4-35 166 12/20/00 3.3-171 185 04/25/05 3.4-36 116 3.3-172 185 04/25/05 3.4-37 166 12/20/00 3.3-173 116 05/30/97 3.4-38 166 07/15/05 3.3-174 116 05/30/97 3.4-38a 166 04/03/06 3.3-175 116 03/06/06 3.4-39 196 3.3-176 116 10/30/98 3.4740 166 12/20/00 3.3-177 116 10/3,0/98 3.4-41 116 3.3-178 116 3.4-42 116 3.3-179 116 04/24/01 3.4-43 166 12 /20/00 3.3-180 116 04/24/01 3.4-44 166 04/03/06 3.3-181 116 07/29/96 3.4-45 166 12 /20/00 3.3-182 166 12/20/00 3.4-46 116 05/30/00 3.3-183 166 12/20/00 3.4-47 146 05/30/00 3.3-184 166 12/20/00 3.4-48 152 05/15/02 3.3-185 166 12/20/00 3.4-49 116 05/30/00 3.4-1 116 02/24/99 3.4-50 116 05/30/00 3.4-2 116 02/24/99 3.4-51 147 03/22/01 3.4-3 116 3.4-52 147 03/22/01 3.4-4 116 3.4-53 147 03/22/01 3.4-5 116 02/24/99 3.4-54 147 04/27/05 3.4-6 116 3.4-55 195 3.4-7 116 3.4-56 195 3.4-8 116 3.4-57 195 3.4-9 195 3.4-58 195 3.4-10 116 3.4-59 195 3.4-11 116 3.4-60 195 NDMS Revision 1, Page 8 of 12 Amendment 200 12/05/06

APPENDIX A TO LICENSE NO. NPF-15 SAN ONOFRE UNIT 3 TECHNICAL SPECIFICATIONS (NUREG-0952)

LIST OF EFFECTIVE PAGES Page No. Volume Amendment/Date Page No. Volume Amendment/Date 3.4-61 195 3.5-11 116 03/03/00 3.4-62 195 3.5-12 116 03/03/00 3.4-63 195 3.5-13 116 03/03/00 3.4-64 195 3.5-14 116 03/03/00 3.4-65 195 3.5-15 116 03/03/00 3.4-66 195 3.5-16 188 07/19/05 3.4-67 195 3.5-17 116 03/03/00 3.4-68 195 3.5-18 116 03/ 14/02 3.4-69 195 3.5-19 116 03/14/02 3.4-70 116 3.5-20 116 07/17/01 3.4-71 196 3.5-20a 116 03/03/00 3.4-72 196 3.5-21 116 3.4-73 196 3.5-22 116 3.4-74 196 3.5-23 116 3.4-75 196 3.5-24 116 3.4-76 116 3.5-25 116 3.4-77 116 3.5-26 116 3.4-78 116 3.5-27 116 3.4-79 116 3.5-28 116 3..4-80 116 09/06/00 3.5-29 116 3.4-81 116 09/06/00 3.5-30 116 3.4-82 116 3.5-31 116 3.4-83 116 3.5-32 116 3.4-84 116 3.5-33 116 3.4-85 116 3.5-34 116 3.4-86 116 3.6-1 116 12/01/98 3.4-87 116 3.6-2 173 08/06/03 3.4-88 116 05/13/02 3.6-3 116 08/06/03 3.4-89 116 05/13/02 3.6-4 116 04/29/03 3.4-90 116 3.6-5 116 12/01/98 3.4-91 116 3.6-6 173 02/11/02 3.4-92 116 3.6-7 116 3.4-93 196 3.6-8 116 3.4-94 196 3.6-9 116 3.4-95 196 3.6-10 116 3.4-96 196 3.6-11 116 12/01/98 3.4-97 196 3.6-12 116 04/29/03 3.4-98 -196 3.6-13 116 07/29/99 3.4-99 196 3.6-14 116 3.4-100 196 3 6-15 116 3.5-1 116 3.6-16 116 04/29/03 3.5-2 116 3.6-17 116 3.5-3 116 3.6-18 116 06/09/00 3.5-4 116 05/05/03 3.6-19 116 3.5-5 116 05/30/97 3.6-20 116 3.5-6 116 3.6-21 116 04/29/03 3.5-7 116 07/15/98 3.6-22 116 10/24/01 3.5-8 188 -07/19/05 3.6-23 192 12/12/05 3.5-9 116 07/15/98 3.6-24 192 12/12/05 3.5-10 116 07/15/98 3.6-24a 192 12/12/05 3.5-I0a 188 07/19/05 3.6-25 116 04/29/03 NDMS Revision 1 Page 9 of 12 Amendment 196 09/19/06

APPENDIX A TO LICENSE NO. NPF-15 SAN ONOFRE UNIT 3 TECHNICAL SPECIFICATIONS (NUREG-0952)

LIST OF EFFECTIVE PAGES Page No. Volume Amendment/Date "Page No. Volume Amendment/Date B 3.6-26 3 116 04/29/03 B 3.7-20 3 116 06/02/04 B 3.6-27 3 173 07/11/02 B 3.7-21 3 116 06/02/04 B 3.6-28 3 173 02/11/02 B 3.7-22 3 116 06/02/04 B 3.6-29 3 116 B 3.7-23 3 116 01/05/01 B 3.6-30 3 116 04/29/03 ýB3.7-24 3 116 12/14/00 B 3.6-31 3 173 05/02/02 B 3.7-25 3 116 B 3.6-32 3 116 :B 3.7-26 3 116 02/28/01 B 3.6-33 3 116 B 3.7-27 3 116 02/28/01 B 3.6-34 3 116 ýB3.7-28 3 116 03/03/00 B 3.6-35 3 173 02/11/02 B 3.7-29 3 116 03/03/00 B 3.6-36 3 173 02/11/02 B 3.7-30 3 116 03/03/00 B 3.6-37 3 188 07/19/05 B 3.7-31 3 182 11/25/03 B 3.6-38 3 188 07/19/05 B 3.7-32 3 182 11/25/03 B 3.6-39 3 116 10/06/00 IB 3.7-33 3 182 11/25/03.

B 3.6-40 3 116 .10/06/00 B 3.7-34 3 116 03/03/00 B 3.6-41 3 116 10/06/00 B 3.7-35 3 116 03/02/01 B 3.6-42 3 116 04/29/03 B 3.7-36 3 116 07/31/00 B 3.6-43 3 116 B 3.7-37 3 116 08/13/01 B 3.6-44 3 116 B 3.7-38 3 116 08/01/01 B 3.6-45 3 116 B 3.7-39 3 116 06/23/99 B 3.6-46 3 116 ;B 3.7-40 3 116 B 3.6-47 3 116 B 3.7-41 3 116 04/03/06 B 3.6-48 3 150 10/29/99 B 3.7-42 3 116 B 3.6-49 3 150 10/29/99 B 3.7-43 3 116 B 3.6-50 3 150 10/29/99 !B 3.7-43a 3 116 05/29/97 B 3.6-51 3 150 10/29/99 B 3.7-43b 3 116 B 3.6-52 3 150 10/29/99 B 3.7-43c 3 118 B 3.6-53 3 150 10/06/00 B 3.7-43d 3 118 07/29/96 B 3.6-54 3 150 10/06/00 B 3.7-43e 3 118 B 3.6-55 3 150 10/29/99 B 3.7-43f 3 118 B 3.6-56 3 150 10/29/99 B 3.7-43g 3 118 B 3.6-57 3 150 10/29/99 ;B 3.7-43h 3 118 B 3.7-1 3 204 06/21/07 B 3.7-43i 3 118 B 3.7-2 3 116 08/18/98 ýB3.7-43j 3 118 B 3.7-3 3 204 06/21/07 - B 3.7-44 3 116 B 3.7-4 3 204 06/21/07 B 3.7-45 3 116 B 3.7-5 3 204 06/21/07 B 3.7-46 3 116 B 3.7-6 3 204 06/21/07 1B3.7-47 3 116 05/30/97 B 3.7-7 3 116 04/16/99 B 3.7-48 3 116 B 3.7-8 3 116 06/23/99 B 3.7-49 3 116 10/17/01 B 3.7-9 3 116 B 3.7-50 3 188 03/07/07 B 3.7-10 3 116 B 3.7-50a 3 188 03/07/07 B 3.7-11 3 116 B 3.7-51 3 116 04/08/07 B 3.7-12 3 116 B 3.7-52 3 116 10/17/01 B 3.7-13 3 116 B 3.7-53 3 116 04/12/01 B 3.7-14 3 116 04/16/99 :B 3.7-54 3 116 04/12/01 B.3.7-15 3 116 B 3.7-55 3 116 03/07/07 B 3.7-16 3 116 B 3 .7-55a 3 116 03/07/07 B 3.7-17 3 116 06/02/04 B 3.7-56 3 116 12/12/07 B 3.7-18 3 116 B 3.7-57 3 116 12/12/07 B 3.7-19 3 116 B 3.7-58 3 116 12/12/07 NDMS Revision 1 Page 10 of 12 Amendment 204 12/12/07

APPENDIX A TO LICENSE NO. NPF-15 SAN ONOFRE UNIT 3 TECHNICAL SPECIFICATIONS (NUREG-0952)

LIST OF EFFECTIVE PAGES Page No. Volume Amendment/Date Page No. Volume Amendment/Date 3.7-59 117 12/12/07 3.8-29 116 06/18/01 3.7-60 116 12/12/07 3.8-29a 160 06/18/01 3.7-61 117 12/12/07 3.8-29b 160 06/18/01 3.7-62 117 12/12/07 3.8-29c 160 06/18/001 3.7-63 200 12/12/07 3.8-29d 160 06/18/01 3.7-64 200 12/12/07 3.8-29e 160 06/18/001 3.7-65 200 12/12/07 3.8-29f 160 06/18/01 3.7-66 200 12/12/07 3.8-30 116 3.7-67 200 12/12/07 3.8-31 116 3.7-68 116 10/13/98 3.8-32 116 3.7-69 116 10/13/98 3.8-33 116 3.7-70 116 10/13/98 3.8-34 166 12/20/00 3.7-71 116 03/05/08 3.8-35 166 12/20/00 3.7-72 116 03/05/08 3.8-36 203 04/05/07 3.7-73 116 03/05/08 3.8-37 116 01/21/98 3.7-74 116 03/05/08 3.8-38 203 04/05/07 3.7-75 116 03/05/08 3.8-39 203 04/05/07 3.7-75a 116 03/05/08 3.8-40 116 01/21/98 3.7-76 116 05/13/02 3.8-41 203 04/05/07 3.7-77 116 3.8-42 116 03/25/02 3.7-78 116 3.8-43 116 3.7-79 116 3.8-44 116 03/25/02 3.8-1i 116 10/06/99 3.8-45 116 3.8-2 116 10/06/99 3.8-46 116 05/03/00 3.8-3 116 10/06/99 3.8-47 116 01/22/99 3.8-4 116 10/06/99 3.8-47a 116 01/22/99 3.8-5 116 10/06/99 3.8-48 116 3.8-6 116 10/06/99 3.8-49 116 01/22/99 3.8-7 188 07/19/05 3.8-50 116 3.8-7a 116 12/10/99 3.8-51 116 3.8-8 116 10/06/99 3.8-52 116 3.8-9 116 11/29/07 3.8-53 116 01/22/99 3.8-10 188 07/19/05 3.8-54 116 08/05/98 3.8-11 116 10/06/99 3.8-55 116 08/30/04 3.8-12 116 10/06/99 3 .8-55a 116 08/05/98 3.8-13 116 10/06/99 3.8-56 116 3.8-14 116 10/06/99 3.8-57 116 3.8-15 116 10/06/99 3.8-58 166 12/20/00 3.8-16 116 06/ 18/01 3.8-59 166 12/20/00 3.8-17 116 06/ 18/01 3.8-60 116 3.8-18 203 04/05/07 3.8-61 116 3.8-19 116 06/ 18/01 3.8-62 116 3.8-20 116 11/29/07 3.8-63 116 3.8-21 116 06/ 18/01 3.8-64 116 3.8-22 116 06/ 18/01 3.8-65 116 3.8-23 116 06/ 18/01 3.8-66 116 07/31/00 3.8-24 116 06/18/01 3.8-67 116 3.8-25 116 06/18/01 3.8-68 116 3.8-26 116 06/18/01 3.8-69 116 3.8-27 116 06/ 18/01 3.8-70 116 3.8-28 116 06/18/01 3.8-71 116 NDMS Revision 1 Pa'ge 11 of 12 Amendment 203 03/05/08

APPENDIX A TO LICENSE NO. NPF-15 SAN ONOFRE UNIT 3 TECHNICAL SPECIFICATIONS (NUREG-0952)

LIST OF EFFECTIVE PAGES Page No. Volume Amendment/Date Page No. Volume Amendment/Date 3;8-72 I16 3.8-73 166 12/20/00 3.8-74 166 12/20/00 3.8-75 116 3.8-76 116 3.8-77 116 3.8-78 116 3.8-79 116 3.8-80 116 3.8-81 116 3.8-82 116 3.8-83 116 03/05/08 3.8-84 116 3.8-85 116 3.8-86 166 12/20/00 3.8-87 166 12/20/00 3.9-1 116 3.9-2 116 3.9-3 166 12/20/00 3.9-4 116 3.9-5 116 3.9-6 166 12/20/00 3.9-7 116 3.9-8 116 3.9-9 116 12/01/98 3.9-10 184 02/18/05 3.9-11 116 10/10/97 3.9-12 116 10/10/97 3.9-13 184 02/18/05 3.9-13a 184 02/18/05 3.9-14 116 10/10/97 3.9-15 116 10/10/97 3.9-16 116 3.9-17 116 07/15/05 3.9-17a 116 04/03/06 3.9-18 166 07/15/05 3.9-19 166 12/20/00 3.9-20 116 3.9-21 116 05/30/97 3.9-22 116 07/15/05 3.9-23 116 04/03/06 3.9-24 166 12/20/00 3.9-24a 166 12/20/00 3.9-25 116 05/30/97 3.9-26 116 10/13/98 3.9-27 116 10/13/98 NDMS Revision 1 Page 12 of 12 Amendment 184 03/05/08

Fuel Storage Pool Boron Concentration 3.7.17 3.7 PLANT SYSTEMS 3.7.17 Fuel Storage Pool Boron Concentration LCO 3.7.17 The fuel storage pool boron concentration shall be 2000 ppm.

APPLICABILITY: Whenever any fuel assembly stored in the fuel storage pool.

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. Fuel storage pool ------------- NOTE-----------

boron concentration LCO 3.0.3 is not applicable.

not within limit.

A.1 Suspend movement of Immediately fuel assemblies in the fuel storage pool.

AND A.2 Initiate action to Immediately restore fuel storage pool boron concentration to within limit.

SAN ONOFRE--UNIT 3 3.7-30 Amendment No. 205

Spent Fuel Assembly Storage 3.7.18 3.7 PLANT SYSTEMS 3.7.1.8 Spent Fuel Assembly Storage LCO 3.7.18 The combination of initial enrichment and burnup of each SONGS 2 and 3 spent fuel assembly stored in Region I shall be within the acceptable burnup domain of Figure 3.7.18-1 or Figure 3.7.18-2, or the fuel assembly shall be stored in accordance with Technical Specification 4.3.1.1.

The combination of initial enrichment and burnup of each SONGS 2 and 3 spent fuel assembly stored in Region II shall be within the acceptable burnup domain of Figure 3.7.18-3 or Figure 3.7.18-4, or the fuel assembly shall be stored in accordance with Technical Specification 4.3.1.1.

Each SONGS 1 uranium dioxide spent fuel assembly stored in Region II shall be stored in accordance with Technical Specification 4.3.1.1.

APPLICABILITY: Whenever any fuel assembly is stored in the fuel storage pool.

ACTIONS

- CONDITION REQUIRED ACTION COMPLETION TIME A. Requirements of the A.1 ------- NOTE-------

LCO not met. LCO 3.0.3 is not applicable.

Initiate action to bring Immediately the noncomplying fuel assembly into compliance.

SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR -3.7.18.1 Verify by administrative means the initial Prior to moving a enrichment, burnup, and cooling time of the fuel assembly to fuel assembly are in accordance with LCO any spent fuel 3.7.18, or Design Features 4.3.1.1, or LCS pool storage 4.3.100. Rev 2, dated 09/27/07. location.

SAN ONOFRE--UNIT 3 3.7-32 Amendment No. 205

Spent Fuel Assembly Storage 3.7.18 FIGURE 3.7.18-1 MINIMUM BURNUP AND COOLING TIME VS. INITIAL ENRICHMENT FOR UNRESTRICTED PLACEMENT OF SONGS 2 AND 3 FUEL.

IN REGION I 'RACKS 25

= 15 E 1-LL 5 0

2.0 2.5 3.0 3.5 4.0 4.5 5.0 Initial U-235 Enrichment (w/o) 0 Years - 5 Years I-oz 10 Years -!- 15 Years E 20 Years SAN ONOFRE--UNIT 3 3.7-33 Amendment No. 205

Spent Fuel Assembly Storage 3.7.18 FIGURE 3.7.18-2 MINIMUM BURNUP AND COOLING TIME VS. INITIAL ENRICHMENT FOR PLACEMENT OF SONGS 2 AND 3 FUEL IN PERIPHERAL POOL LOCATIONS IN REGION I RACKS 15

~10

-o E

c5 0) z-0 3.0 3.5 4.0 4.5 5.0 Initial U-235 Enrichment (w/o)

E OYears - 5 Years IF 10Years 15Years Ei 20 Years SAN ONOFRE--UNIT 3 3.7-34 Amendment No. 205

Spent Fuel Assembly Storage 3.7.18 FIGURE 3.7.18-3 MINIMUM BURNUP AND COOLING TIME VS. INITIAL ENRICHMENT FOR UNRESTRICTED PLACEMENT OF SONGS 2 AND 3 FUEL IN REGION II RACKS 60-

.50,

ý0 -

CA.

E c 30-E a) 20-

)4 LL 2 3 4 5 Initial U-235 Enrichment (w/o)

-- E 0 Years 8 5 Years - 10 Years - 15 Years R 20 Years SAN ONOFRE--UNIT 3 3.7-34a Amendment No. 205 1

Spent Fuel Assembly Storage 3.7.18 FIGURE 3.7.18-4 MINIMUM BURNUP AND COOLING TIME VS. INITIAL ENRICHMENT FOR PLACEMENT OF SONGS 2 AND 3 FUEL IN PERIPHERAL POOL LOCATIONS IN REGION II RACKS 40 030 E

' 20

.0 E

U) j310

L3 I

1.5 2 2.5 3 3.5 4 4.5 5 Initial U-235 Enrichment (w/o)

E 0 Years ae 5 Years --- 10Years vz 15Years -- 20Years SAN ONOFRE--UNIT 3 3.7-34b Amendment No. 205 1

Design Features 4.0 4.0 DESIGN FEATURES (continued) 4.3 Fuel Storage 4.3.1 Criticality 4.3.1.1 The spent fuel storage racks are designed and shall be maintained with:

a. Fuel assemblies having a maximum U-235 enrichment of 4.8 weight percent;
b. Keff < 1.0 if fully flooded with unborated water, which includes an allowance for uncertainties as described in Section 9.1 of the UFSAR;
c. Keff
  • 0.95 if fully flooded with water borated to 1700 ppm, which includes an allowance for uncertainties as described in Section 9.1 of the UFSAR;
d. Three or five Borated stainless steel guide tube inserts (GT-Inserts) may be used. When three Borated stainless steel guide tube inserts are used, they will be installed in an assembly's center guide tube, the guide tube associated with the serial number, and the diagonally opposite guide tube. Fuel containing GT-Inserts may be placed in either Region I or Region II. However, credit for GT-Inserts is only taken for Region II storage.

A five-finger CEA may be installed in an assembly.

Fuel containing a five-finger CEA may be placed in either Region I or Region II. Credit for inserted 5-finger CEAs is taken for both Region I and Region II.

e. A nominal 8.85 inch center to center distance between fuel assemblies placed in Region II;
f. A nominal 10.40 inch center to center distance between fuel assemblies placed in Region I; (continued)

SAN ONOFRE--UNIT 3 4.0-4 Amendment No. 205 I

Design Features 4.0 4.0 DESIGN FEATURES (continued) 4.3.1 Criticality (continued)

g. Prior to using the storage criteria of LCO 3.7.18 and LCS 4.0.100, the following uncertainties will be applied:

(1) The calculated discharge burnup of San Onofre Units 2 and 3 assemblies will be reduced by 6.6%.

(2) The calculated discharge burnup of San Onofre Unit I fuel assemblies will be reduced by 10.0%.

h. Units 2 and 3 fuel assemblies with a burnup in the "acceptable range" of Figure 3.7.18-1 are allowed unrestricted storage in Region I;
i. Units 2 and 3 fuel assemblies with a burnup in the "acceptable range" of Figure 3.7.18-2 are allowed unrestricted storage in the peripheral pool locations with I or 2 faces toward the spent fuel pool walls of Region I;
j. Units 2 and 3 fuel assemblies with a burnup in the "acceptable range" of Figure 3.7.18-3 are allowed unrestricted storage in Region II;
k. Units 2 and 3 fuel assemblies with a burnup in the "acceptable range" of Figure 3.7.18-4 are allowed unrestricted storage in the peripheral pool locations with 1 or 2 faces toward-the spent fuel pool walls of Region I1;
1. Units 2 and 3 fuel assemblies with a burnup in the "unacceptable range" of Figure 3.7.18-1, Figure 3.7.18-2, Figure 3.7.18-3, and Figure 3.7.18-4 will be stored in compliance with,.Licensee Controlled Specification 4.0.100 Rev. 2, dated 09/27/07; and
m. Each SONGS 1 uranium dioxide spent fuel assembly stored in Region II shall be stored in accordance with Licensee Controlled Specification 4.0.100 Rev. 2, dated 09/27/07.

(continued)

SAN ONOFRE-UNIT 3 4. 0-4a Amendment No. 205

Fuel Storage Pool Boron Concentration B 3.7.17 B 3.7 PLANT SYSTEMS B 3.7.17 Fuel Storage Pool Boron Concentriation BASES BACKGROUND As described in LCO 3.7.18, "Spent Fuel Assembly Storage,"

fuel assemblies are stored in the spent fuel racks fn accordance with criteria based on initial enrichment, discharge burnup, and cooling time (plutonium decay).

Although the water in the spent fuel pool is normally borated to 2 2000 ppm, the criteria that limit the storage of a fuel assembly to specific rack locations is conservatively developed without taking credit for boron while maintaining Keff < 1.0. Credit for boron is taken to maintain Keff

  • 0.95.

APPLICABLE Soluble boron in the spent fuel pool is credited in SAFETY ANALYSES criticality analyses for normal and accident conditions.

The relevant accidents are 1) Fuel Assembly Dropped Horizontally On Top of the Racks, 2) Fuel Assembly Dropped Vertically Into a Storage Location Already Containing a Fuel Assembly,:3) Fuel Assembly Dropped to the SFP Floor, and 4)

Fuel Misloading in either Region I or Region II. The.

limiting accident is Fuel Misloading in either Region I or Region II.

A fuel assembly could be inadvertently loaded into a spent fuel rack location not allowed by LCO 3.7.18 (e.g., an un-irradiated fuel assembly or an insufficiently depleted fuel assembly). This accident is analyzed assuming the misloading of one fresh assembly with the maximum permissible enrichment. !!However, the negative reactivity effect of the soluble boron compensates for the increased

-reactivity caused by the postulated accident scenario.

Under normal, non-accident conditions, the soluble boron needed to maintain Keff less than or equal to 0.95, including uncertainties, is 970 ppm. Under accident conditions, the soluble boron needed to maintain Keff less than or equal\ to 0.95, including uncertainties, is 1700 ppm. A SFP boron dilution analysis shows that dilution from 2000.ppm to below 1700 is not credible. Therefore, the minimum required soluble boron concentration is 2000 ppm.

The concentration of dissolved boron in the fuel pool satisfies Criteriqn 2 of the NRC Policy Statement.

(continued)

SAN ONOFRE--UNIT 3 B. 3. 7-71 Amendment No. 116 03/05/08 1

Fuel Storage Pool Boron Concentration B 3.7.17 BASES (continued)

LCO The specified concentration of 2000 ppm dissolved boron in the fuel pool preserves ;the assumptions used in the analyses described above. This concentration of dissolved boron is the minimum required concentration for fuel assembly storage and movement within the spent fuel pool.

APPLICABILITY This LCO applies whenever fuel assemblies are stored in the spent fuel pool.

ACTIONS A.1 and A.2 The Required Actions are modified by a Note indicating that LCO 3.0.3 does not apply.

When the concentration of boron in the spent fuel pool is less than required 2000 ppm, immediate action must be taken to preclude an accident from happening or to mitigate the consequences of an accident in progress. This is most efficiently achieved by immediately suspending the movement of fuel assemblies. This does not preclude the movement of fuel assemblies to a safe position. In addition, action must be immediately initiated to restore boron concentration to the required 2000 ppm.

If moving irradiated fuel assemblies while in MODE 5 or 6, LCO 3.0.3 would not specify any action. If moving irradiated fuel assemblies while in MODE 1, 2, 3, or 4, the fuel movement is independent of reactor operation.

Therefore, inability to suspend movement of fuel assemblies is not sufficient reason to require a reactor shutdown.

(continued)

SAN ONOFRE7-UNIT 3 B 3.7-72 Amendment No. 116 03/05/08

Fuel Storage Pool Boron Concentration B 3.7.17 BASES (continued)

SURVEILLANCE SR 3.7.17.1 REQUTIREMENTS This SR verifies that the concentration of boron in the spent fuel pool is within the required limit. As long as this SR is met, the analyzed incidents are fully addressed.

The 7 day Frequency is appropriate because no major replenishment of pool water is expected to take place over a short period of time.

REFERENCES 1. UFSAR, Section 9.1.

SAN ONOFRE--UNIT 3 B 3.7-73 Amendment No. 116 03/05/08 1

Spent Fuel Assembly Storage B 3.7.18 B 3.7 PLANT SYSTEMS B 3.7.18 Spent Fuel Assembly Storage BASES BACKGROUND The spent fuel storage facility is designed to store either new (nonirradiated) nuclear fuel assemblies, or burned (irradiated) fuel assemblies in a vertical configuration underwater. The storage pool-is sized to store 1542 fuel assemblies. Two types/sizes of spent fuel storage racks are used (Region I and Region II). The two Region I racks each contain 156 storage locations each spaced 10.40 inches on center in a 12x13 array. Four Region II storage racks each contain 210 storage locations in a 14x15 array. The remaining two Region II racks each contain 195 locations in a 13x15 array. All Region II locations are spaced 8.85 inches on center.

To maintain Keff

  • 0.95 for spent fuel of maximum enrichment up to 4.8 w/o, (1) soluble boron is credited, and (2) the following storage patterns and borated stainless steel guide tube inserts are used as needed:

(1) unrestricted storage, minimum discharge burnup and cooling time requirements vs. initial enrichment, (2) SFP Peripheral storage, minimum discharge burnup and cooling time requirements vs. initial enrichment, (3) 2x2 storage patterns, minimum discharge burnup and cooling time requirements.vs. initial enrichment, (4) 3x3 storage patterns, minimum discharge burnup and cooling time requirements vs. initial enrichment, (5) credit for inserted Control Element Assemblies (CEAs),

(6) credit for erbia in fresh assemblies, (7) credit for cooling time (Pu-241 decay), and, (8) credit for borated stainless steel guide tube inserts.

(continued)

SAN ONOFRE--UNIT 3 B 3.7-74 Amendment No. 116 03/05/08

Spent Fuel Assembly Storage B 3.7.18 BASES (continued)

BACKGROUND When soluble boron is credited, the following acceptance (continued) criteria apply:

(1) Under normal conditions, the 95/95 neutron multiplication factor (Keff), including all uncertainties, shall be less than 1.0 when flooded with unborated water, and, (2) Under normal and accident conditions, the 95/95 neutron multiplication factor (Keff), including all uncertainties, shall be less than or equal to 0.95 when flooded with borated water.

APPLICABLE The spent fuel storage facility is designed for SAFETY ANALYSES noncriticality by use of adequate spacing, neutron absorbing stainless steel cans, borated water with a minimum soluble boron concentration of 970 ppm; and storage of fuel assemblies in accordance with the administrative controls in LCO 3.7.18 and LCS 4.0.100, "Fuel Storage Patterns".

The spent fuel assembly storage satisfies Criterion 2 of the NRC Policy Statement.

LCO The restrictions on the placement of fuel assemblies within the spent fuel pool, in the accompanying LCO, ensure that the Keff of the spent fuel pool will always remain < 1.00 under normal, non-accident conditions assuming the pool to be flooded with unborated water. The Keff of the spent fuel pool will always remain 'ý 0.95 under normal, non-accident conditions assuming the pool to be flooded with borated water with a minimum soluble boron concentration of 970 ppm.

The Keff of the spent fuel pool will always remain < 0.95 under accident conditions assuming the pool to be flooded with borated water with a minimum soluble boron concentration of 1700 ppm. The restrictions are consistent with the criticality safety analysis performed for the spent fuel pool.

(continued)

SAN ONOFRE--UNIT 3 B 3.7-75 Amendment No. 116 03/05/08

Spent Fuel Assembly Storage B 3.7.18 BASES (continued)

APPLICABILITY This LCO applies whenever any fuel assembly is stored in Regions I and II of the spent fuel pool.

ACTIONS A.1 Required Action A.1 is modified by a Note indicating that LCO 3.0.3 does not apply.

When the configuration of fuel assemblies stored in Regions I and II of the spent fuel pool is not in accordance with LCO 3.7.18, immediate action must be taken to make the necessary fuel assembly movement(s) to bring the configuration into compliance.

If moving irradiated fuel assemblies while in MODE 5 or 6, LCO 3.0.3 would not specify any action. If moving irradiated fuel assemblies while in MODE 1, 2, 3, or 4' the fuel moVement is independent of reactor operation.

Therefore, in either case, inability to move fuel assemblies is not sufficient reason to require a reactor shutdown.

SURVEILLANCE SR .3.7.18.1 REQUIREMENTS This SR verifies by administrative means that the fuel assembly is stored in accordance with LCO 3.7.18, or Design Features 4.3.1.1, or LCS 4.0.100. For fuel assemblies not stored in accordance with LCO 3.7.18, performance of this SR will ensure compliance with Specification 4.3.1.1.

This surveillance is performed prior to the initial storage of a fuel assembly in a spent fuel pool location and prior to each subsequent movement to a new location.

REFERENCES UFSAR, Section 9.1.2.2.

SAN ONOFRE--UNIT 3 B 3.7-75a Amendment No. 116 03/05/08 1

Distribution Systems -Operating B 3.8.9 Table B 3.8.9-1 (page I of 1)

AC and DC Electrical Power Distribution Systems TYPE VOLTAGE TRAIN A TRAIN B AC safety 4160 V ESF Bus A04 ESF Bus A06 buses 480 V Load Center B04. Load Center B06 TRAIN A TRAIN C TRAIN B TRAIN D Bus DI Bus D3 Bus D2 Bus D4 DC buses(3) 125 V from from from from battery battery battery battery B007 and B009 and B008 and B010 and charger charger charger charger BOO1 (4) B003 (4) BOO2 (5) B004 )

TRAIN A TRAIN C TRAIN B TRAIN D AC vital Bus YO1 Bus Y03 Bus Y02 Bus Y04 buses 120 V from from from from inverter inverter inverter inverter YO01 Y003 Y002 Y004 connected connected connected connected to bus DI to bus D3 to bus D2 to bus D4 NOTES: (1) Each train of the AC,,DC, and AC vital bus electrical power distribution systems is a subsystem.

  • (2) If a support system (e.g., charger or inverter) is declared inoperable and it has its own LCO, entry into LCO 3.8.9 is not required. Only entry into its LCO is required.

(3) An OPERABLE Class 1E battery bank BOOX may replace any battery BOO7 through BOO to allow battery maintenance (including replacement) activities.

(4) Swing Charger B021 may be aligned as the OPERABLE charger in place of BOO1 or B003.

(5) Swing Charger B022 may be aligned as the OPERABLE charger in place of BOO2 or B004.

SAN ONOFRE--UNIT 3 B 3.8-83 Amendment No. 116 03/05/08

SAN ONOFRE UNIT 3 LICENSEE CONTROLLED SPECIFICATIONS LIST OF EFFECTIVE PAGES Page No. Rev. Date Page No. Rev. Date LOEP-1 03 /05/08 3.1-103-2 0 04/24/96 LOEP-2 08/29/07 3.1-103-3 0 04/2 4/96 LOEP-3 12/12/07 3.1-104-1 4 12/02/02 LOEP-4 03/05/08 3.1-104-2 2 05/04/99 LOEP-5 09/27/07 3.1-104-3 2 05/04/99 LQEP-6 11/30/07 3.1-104-4 2 11/ 18/99 09/07/06 3.1-105-I 2 04/16/99 iv iii 09/07/06 3.1-105-2 0 07/29/96 09/07/06 3.1-105-3 2 04/16 /99 iv 06/27/00 3.1-105-4 2 04/16 /99 V 09/07/06 3.1-105-5 2 06/12 /97 2.0-100-1 05/2 5/00 3.1-105-6 1 06/12 /97 2.0-100-2 04/24/96 3.1-105-7 0 07/29/96 2.0-100-3 05/2 5/00 3.1-105-8 0 07 /2 96 2.0-100-4 04/2 4/96 3.1-105-9 1. 1202 /96 2.0-100-5 03/29/99 3.1-106-1 3 05/2 00 2.0-100-6 03/2 9/99 3.1-106-2 3 05/2 00 2.0-100-7 03/29/99 3.1-106-3 1 05/31/97 2.0-100-8 03/2 /99 3.1-106-4 2 05/17/99 2.0i-00-9 03/2 /99 3.1-106-5 0 05/17 99 2.0-100-10 03/29/99 3.1-106-6 1 05/2 00 2.0-100-11 05/12/00 3.1-107-1 0 11/18 05 2.0-100-12 05/12/00 3.1-107-2 0 11/ 1805 2.0-100-13 05/12/00 3.1-107-3 0 11/18/05 2.0-100-14 03/29/99 3.1-107-4 0 11/18 /05 2.0-100-15 03/29/99 3.1-107-5 0 11/18/05 2.0-100-16 03 /29/99 3.1-108-1 1 07/20/06 2.0-100-17 03 /29/99 3.1-108-2 0 11/18/05 2.0-100-18 05/2 5/00 3.1-108-3 0 11/18/05 3.0-1 05/2 5/00 3.1-108-4 0 11/18/05 3.0-la 05/2 5/00 3.1-108-5 0 11/18/05 3.0-2 03/14/02 3.2-100-1 1 05/1100 3.0-3 03/14/02 3.2-100-2 0 04/24/96 3.0-4 03/14/02 3.2-100-3 0 04/24/96 3.0-5 03/14/02 3.2-101-1 2 04/16 /99 3.0-6 03/14/02 3.2-101-2 2 06/01 /00 3.1-100-1 11/12/98 3.2-101-3 2 06/22/98 3.1-100-2 05/13/97 3.2-101-4 2 04/16 /99 3.1-100-3 05/13/97 3.2-101-5 1 06/12 /97 3.1-101-1 OS/2 5/00 3.2-101-6 0 06/12/97 3.1-101-2 04/24/96 3.2-102-1 3 04/16 /99 3.1-101-3 04/16 /99 3.2-102-2 2 04/16/99 3.1-101-4 04/16/99 3.3-100-1 8 08/29/07 3.1-101-5 05/2 5/00 3.3;-100-2 0 08/01/96 3.1-102-1 02/12/99 3.3-100-3 0 08/01/96 3.1-102-2 02/12/99 3.3-100-4 4 08/29/07 3.1-102-3 02/12/99 3.3-100-5 5 08/29/07 3.1-103-1 11/12/98 3.3-100-6 8 08/29/07 NDMS Revision 1 Page I of 6 03/05/08

SAN ONOFRE UNIT 3 LICENSEE CONTROLLED SPECIFICATIONS LIST OF EFFECTIVE PAGES Page No. Rev. Date Page No. Rev. Date 3.3-100-7 01/28/05 3.3-108-6 10/05/00 3.3-101-1 08/29/07 3.3-109-1 02/20 /07 3.3-101-2 08/29/07 3 3-109-la 02/20 /07 3.3-101-3 08/29/07 3 3-109-2 02/20/07 3.3-102-1 04/19/04 3.3-109-3 02 /2 /07 3.3-102-2 04/19/04 3.3-109-4 02/20/07

3. 3-102-2a 04/19/04 3.3-109-5 02 /2 /07
3. 3-102-2b 04/19/04 3.3-109-6 02/20/07 3.3-102-3 04/2 4/96 3.3-110-1 07/23/01 3.3-102-4 01/05/01 3.3-110-2 07/021/01 3.3-102-5 0 1/05/01 3.3-110-3 07/0*2/01 3.3-102-6 01/05/01 3.3-110-4 07/021/01 3.3-102-7 11/13/03 3.3-110-5 07 /23 /01 3.3-102-8 04/19/04 3.3-111-1 02 /05/01 3.3-102-8a 04/19/04 3.3-111-2 03 /06/98 3.3-102-8b 04/19/04 3.3-111-3 03/06/98 3.3-102-9 01/05/01 3.3-111-4 02 05/01 01/0/01 3.3-111-5 02 05/01 3.3-102-10 3.3-102-11 01/05/01 3.3-112-1 12/05/06 3.3-103-1 05 /25/00 3.3-112-2 12/05/06 3.3-103-2 04/24/96 3. 3-112-3 12/05/ 06 3.3-103-3 O5/2 /00 3.3-112-4 12/05/06 3.3-104-1 05/2 5/00 3.3-112-5 12 /05/06 3.3-104-2 05/25/00 3.3-112-6 12 /0/06 3.3-104-3 12/14/00 3.3-112-7 12/05/06 3.3-104-4 01/29/99 3.3-112-8 12 /05/06 3.3-104-5 05/2 /00 3.3-112-9 12/05/06 3.3-105-1 05/2 /00 3.3-113-1 10/27/03 3.3-105-2 04/24/96 3.3-113-2 03/19/03 3.3-105-3 05/2 5/00 3.3-113-3 03/19/03 3.3-.106-1 06/07/01 3.3-113-4 10/27/03 3.3-106-2 04/23 /01 3.3-113-5 10/27/03 3.3-106-3 03/29/99 3.3-113-6 03/19/03 3.3-106-4 03/29/99 3.3-113-7 10/27/03 3.3-106-5 05/04/99 3.3-114-1 10/27/03 3.3-106-6 01/02/99. 3.3-114-2 03/19/03 3.3-106-7 05/30/917 3.3-114-3 03/19/03 03/'19/03 3.3-106-8 06/07/01 3.3-114-4 3.3-106-9 06/07 /01 3.3-114-5 10/27/03 3.3-106-10 04/23/01 3.3-114-6 03/19/03 3.3-107-1 08/22/00 3.3-114-7 10/27/03 3.3-107-2 04/24/96 3.3-115-i 04/25 /05 3.3-107-3 05/2 /00 3.3-115-2 04/25/05 3.3-108-1 10/05/00 3.3-115-3 04/25/05 3.3-108-2 04/24/96 3.3-115-4 04/25 /05 3.3-108-3 10/05/00 3.4-101-1 05/2 5/00 3.3-108-4 10/O5/0O 3.4-101-2 05/25/00 3.3-108-5 10/05/00 3.4-101-2a O5/25/00 NDMS Revision 1 Page 2 of 6 08/29/07

SAN ONOFRE UNIT 3 LICENSEE CONTROLLED SPECIFICATIONS LIST OF EFFECTIVE PAGES Page No. Rev. Date Page No. Rev. Date 3.4-101-3 04 /24/96 3.6-101-2 3 05/28/04 3.4-101-4 04/28/97 3.6-101-3 0 04/24/96 3.4-101-5 07/12/99 3.6-101-4 0 04/24/96 3.4-101-6 07/12/99 3.6-101-5 2 05/28/04 3.4-101-7 07/12/99 3.6-101-6 0 04/2 /96 3.4-101-8 05/2 5/00 3.6-101-7 0 04/24/96 3.4-101-9 07/12/99 3.6-101-8 3 05 /28/04 3.4-102-1 02/11/03 3.7-101-1 1 12/18/02 3.4-102-2 05/25/00 3.7-101-2 0 09 /21/02 3.4-102-3 01/2 1/98 3.7-101-3 0 *09/21/02 3.4-102-4 02/11/03 3.7-101-4 1 12/18/02 3.4-103-1 12/12/07 3.7-101-5 0 09 /21/02 3.4-103-2 12/12/07 3.7-101-6 1 12/18/02 3.4-103-3 12/12/07 3.7-101-7 0 09 /21/02 3.4-103-4 12/12/07 3.7-101-8 1 12/18/02 3.4-103-5 12/12/07 3.7-101-9 0 09 1/02 3.4-103-6 12/12/07 3.7-101-10 0 09/2 1/02 3.4-103-7 12/12/07 3.7-101-11 0 09/2 1/02 3.4-103-8 12/12/07 3.7-101-12 0 09/2 1/02 3.4-106-1 1212 /07 3.7-102-1 8 04/2 3/01 3.4-106-2 12/12/07 3.7-102-2 4 04/2 /01 3.4-106-3 12/12/07 3.7-102-3 1 1121 /97 3.4-107-1 12/12/07 3.7-102-4 2 05/2 /00 3.4-107-2 12/12/07 3.7-102-5 2 11/21 /97 3.4-107-3 12/12/07 3.7-102-6 2 11/21/97 3.4-112.1-1 12/12/07 3.7-102-7 6 04/23 /01 3.4-112.1-2 12/12/07 3.7-103-1 6 04/12 /07 3.4-112.1-3 12/12/07 3.7-103-2 2 04/12/07 3.4-112.2-1 12/12/07 3.7-103-3 2 07/29/99 3.4-112.2-2 12/12/07 3.7-103-4 0 04/24/96 3.4-112.2-3 12/12/07 3.7-103-5 0 04/2 /96 3.5-100-1 04/24/96 3.7-103-6 1 05/0997 3.5-100-2 04/24/96 3.7-10'3-7 2 08/20/98 3.5-101-1 12 /23/99 3.7-103-8 5 04/12/07 3.5-101-2 04/24/96 3.7-104-1 5 07/16/04 3.5-101-3 04/24/96 3.7-104-2 3 05/2 00 3.5-101-4 12/23/99 3.7-104-3 2 07/16 04 3.6-100-1 02111/02 3.7-104-4 4 07/16 04 3.6-100-2 02/02/01 3.7-104-5 2 07/16 04 3.6-100-3 02111/02 3.7-105-1 13 05/29 07 3.6-100-4 02/02/01 3.7-105-2 5 05/09 01 3.6-100-5 02/02/01 3.7-105-3 3 05/09 01 3.6-100-6 02/02/01 3.7-105-4 5 06/3 003 3.6-100-7 02/02/01 3.7-105-5 4 11/14/06 3.6-100-8 02/02/01 3.7-105-6 3 05:/09 0 3.6-100-9 02/02/01 3.7-105-7 3 05/09/01 3.6-100-10 02/02/01 3.7-105-8 4 10/29/04 3.6-101-1 05/28/04 3.7-105-9 5 07/2 1/05 NDMS Revision 1 Page 3 of 6 12/12/07

SAN.ONOFRE UNIT 3 LICENSEE CONTROLLED SPECIFICATIONS LIST OF EFFECTIVE PAGES Page No. Rev . Date Page No. Rev. Date 3.7-105-10 05/29/07 3.7-112-2 0 04 /96 3.7-105-11 05/09/01 3.7-112-3 1 05/2 5/00 3.7-105-12 05/29/07 3.7-113-1 20 12/21/06 3.7-105-13 06/30/03 3.7-113-2 4 06/27/00 3.7-105--14 06/30/03 3.7-113-3 5 05/16 01 3.7-105-15 05/29/07 3.7-113-4 10 09/20 05 3.7-105-16 05/29/07 3.7-113-5 3 05/16 01 3.7-105-17 05/09/01 3.7-113-6 3 07 /3 03 3.7-105-18 05/29/07 3.7-113-7 3 11/13 03 3.7-105-19 06/30/03 3.7-113-8 2 03/28 05 3.7-105-20 06/30/03 3.7-113-9 3 06/27/00 3.7-105-21 05/09/ 01 3.7-113-10 5 05/16 /01 3.7-105-22 05/09/01 3.7-113-11 3 03 /2805 3.7-105-23 07/2 1/05 3.7-113-12 4 07/13/05 3.7-106-1 02/19/04 3.7-113-13 2 06/27/00 3.7-106-2 12/18/98 3.7-113-14 3 12/21/06 3.7-106-3 02/19/04 3.7-113-15 2 06/27/00 3.7-106-4 12/18/98 3.7-113-16 1 06/27/00 3 .7-106-5 10/28/02 3.7-113-17 2 06/27/00 3.7-106-6 10/28/ 02 3.7-113-18 2 06/27/00 3.7-106-7 10/28/02 3.7-113-19 1 06/27/00 3.7-106-8 10/28/ 02 3.7-113-20 3 07/13 /05 3.7-106-9 10/28/ 02 3.7-113-21 4 12/21/06 3.7-106-10 10/28/02 3.7-113-22 3 07/13/05 3.7-107-1 05/2 5/00 3.7-113-23 2 12 /2 06 3.7-107-2 04/2 4/96 3.7-113-24 8 06/27/00 3.7-107-3 04/24/96 3.7-113-25 1 06/27 00 3.7-107-4 O5/25/00 3.7-113-26 2 06/27 00 06/28/02 3.7-114-1 1 05/2 00 3.7-108-1 3.7-108-2 10/04/00 3.7-114-2 0 08/14 /96 3.7-108-3 10/19/98 3.7-114-3 1 05/2 00 3.7-108-4 10/19/98 3.7-115-1 1 05/2 00 3.7-108-5 11/27/96 3.7-115-2 0 08/27 96 3.7-108-6 04/24/96 3.7-115-3 1 05/2 /O0 3.7-108-7 06/28/02 3.7-116-1 4 03/05 08 3.7-108-8 05/09/97 3.7-116-2 3 03/05 08 3.7-108-9 06/28/02 3.7-117-1 3 02/19/04 3.7-108-10 10/04/00 3.7-117-2 2 06/12/02 3.7-109-1 05/25/00 3.7-118-1 2 12/05/06 3.7-109-2 07/29/99 3.7-118-2 2 12/05 06 3.7-109-3 05 /25/00 3.7-118-3 0 12 /0 06 3.7-110-1 05/23/01 3.7-118-4 0 12/05/06 3.7-110-2 04/24/96 3.7-118-5 0 12/05/06 3.7-110-3 02 /28/01 3.7-118-6 0 12/05/06 3.7-111-1 05/2 5/00 3.8-100-1 10 11/07/06 3.7-111-2 04/24/96 3.8-100-2 3 03/28 /05 3.7-111-3 05/25/00 3.8-100-3 1 03/06/01 3.7-112-1 05/25/00 3.8-100-4 2 11/07/06 NDMS Revision 1 Page 4 of 6 03/05/08

SAN ONOFRE UNIT 3 LICENSEE CONTROLLED SPECIFICATIONS LIST OF EFFECTIVE PAGES Page No. Rev. Date Page No. Rev. Date 3.8-100-5 11/07/06 3.9-107-2 O5/2 5/00 3.8-100-6 05/28/97 3.9-107-3 12 /21/00 3.8-100-7 11/07/06 3.9-107-4 12 *21/00 3.8-100-8 11/22/99 4.0-10.0-1 09/27/07 3.8-100-9 11/22/99 4.0-100-2 09/27/07 3.8-100-10 11/22/99 4.0-100-3 09/27/07 3.8-100-11 05/2 8/97 4.0-100-4 09/27/07 3.8-100-12 04/24/96 4.0-100-5 09/27/07 3.8-100-13 04/2 5/05 4.0-100-6 09/27/07 3.8-100-14 03/06/001 4.0-100-7 09/27/07 3.8-100-15 03/12/02 4.0-100-.8 09/27/07 3.8-100-16 03/12/02 4.0-100-9 09/27/07 3.8-100-17 03/12/02 4.0-100-10 09/27/07 3.8-100-18 03/12/02 4.0-100-11 09/2.7/07 3.8-101-1 05/27/05 4.0-100-12 09/27/07 3.8-101-2 05/27/05 4.0-100-13 09/27/07 3.8-101-3 04/24/96 4.0-100-14 09/27/07 3.8-101-4 04/24/96 4.0-100-15 09/27/07 3.8-101-5 04/24/96 4.0-100-16 09/27/07 3.8-101-6 05/28/97 4.0-100-17 09/27/07 3.8-101-7 04/24/96 4.0-100-18 09/27/07 3.8-101-8 05/25/00 4.0-100-19 09/27/07 3.8-102-1 01/03/00 4.0-100-20 09/27/07 3.8-102-2 01/03/00 4.0-100-21 09/27/07 3.8-102-3 01/03/00 4.0-100-22 09/27/07 3.8-102-4 01/03/00 4.0-100-23 09/27/07 3.8-102-5 01/03/00 4.0-100-24 09/27/07 3.8-102-6 01/03/00 4.0-100-25 09/27/07 3.8-102-7 01/03/00 4.0-100-26 09/2 7/07 3.8-102-8 01/03/00 4.0-100-27 09/27/07 3.8-102-9 01/03/00 4.0-100-28 09/27/07 3.9-100-1 11/18/05 4.0-100-29 09/27/07 3.9-100-2 11/18/05 4.0-100-30 09/27/07 3.9-100-3 11/18/05 4.0-100-31 09/27/07 3.9-101-1 O5/25/00 4.0-100-32 09/27/07 3.9-101-2 05/25/00 4.0-100-33 09/27/07 3.9-102-1 05 /25/00 4.0-100-34 09/27/07 3.9-102-2 05/25/00 4.0-100-35 09 /27/07 3.9-103-1 05/25/00 4.0-100-36 09/27/07 3.9-103-2 05/09/97 4.0-100-37 09/27/07 3.9-103-3 05/25/00 4.0-100-38 09/27/07 3.9-104-1 05/25/00 4.0-100-39 09/27/07 3.9-104-2 05/25/00 4.0-100-40 09 /27/07 3.9-104-3 05/25/00 4.0-100-41 09/27/07 3.9-106-1 05/25/00 4.0-100-42 09/27/07 3.9-106-2 05/09/97 4.0-100-43 09/27/07 3.9-106-3 05/25/00 4.0-100-44 09/27/07 3.9-107-1 12/21/00 NDMS Revision 1 Page 5 of 6 09/27/07

SAN ONOFRE UNIT 3 LICENSEE CONTROLLED SPECIFICATIONS LIST OF EFFECTIVE PAGES Page No. Rev. Date Page No. Rev. Date 4.0-100-45 2 09/27/07 4.0-100-46 2 09/27/07 4.0-100-47 2 09/27/07 4.0-100-48 2 09/27/07 4.0-100-49 2 09/27/07 4.0-100-50 2 09/27/07 4.0-100-51 2 09/27/07 4.0-100-52 2 09/27/07 4.0-100-53 2 09/27/07 4.0-100-54 2 09/27/07 4.0-100-55 2 09/27/07 4.0-100-56 2 09/27/07 4.0-100-57 2 09/27/07 4.0-100-58 2 09/27/07 4.0-100-59 2 09/27/07 4.0-100-60 2 09/27/07 4.0-100-61 2 09/27/07 4.0-100-62 2 09/27/07 4.0-100-63 2 09/27/07 5.0-100-1 3 08/29/06 5.0-100-2 3 08/29/06 5.0-100-3 1 08/29/06 5.0-100-4 1 09/24/03 5.0-101-1 0 04/24/96 5.0-103-1 5 11/30/07 5.0-103-2 2 11/30/07 5.0-103-3 0 04/24/96 5.0-103-4 5 02/28/01 5.0-103-5 0 04/24/96 5.0-103-6 1 11/06/06 5.0-104-1 1 02/14/97 5.0-104-2 1 02/14/97 5.0-105-1 2 03/21/06 5.0-105-2 2 03/21/06 NDMS Revision 1 Page 6 of 6 11/30/07

(LCS 3.7.116 deleted upon implementation of Amendment 205)

SAN ONOFRE--UNIT 3 3.7-116-1 Rev. 4 03/05/08 1

(LCS 3.7.116 deleted upon implementation of Amendment 205)

SAN ONOFRE--UNIT 3 3.7-116-2 Rev. 3 03/05/081

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES LCS 4.0.100 Fuel Storage Patterns NOTE 1:

This Licensee Controlled Specification is listed by revision number and data in Technical Specification 4.3.1. All changes to pages 1 through 61 Rev. 2 dated 09/27/2007 of this LCS (i.e., excluding the Bases pages) must be approved by the NRC via the amendment application process in conjunction with an associated change to Technical Specification 4.3.1.

NOTE 2:

Prior to using the storage criteria in 4.0.100.1, 4.0.100.2, and 4.0.100.4 below, the following uncertainties shall be applied:

(1) The calculated discharge burnup of San Onofre Units 2 and 3 fuel assemblies will be reduced by 6.6%.

(2) The calculated d~ischarge burnup of San Onofre Unit I fuel assemblies will be reduced by 10.0%.

VALIDITY STATEMENT: Rev. 2 effective upon NRC approval, to be implemented within 180 days.

4.0.100 New or burned fuel (which does not meet the criteria of LCO 3.7.18 for unrestricted storage or storage at the pool periphery) may be stored in Region I or Region II in accordance with the allowable Storage Patterns described in this LCS.

4.0.100.1 Region I = Region I Storage Patterns are given in Tables 1-1 through 1-8 and Figures I-I through 1-9.

4.0.100.2 Region II = Region II Storage Patterns are given in Tables II-1 through 11-15 and Figures II-I through 11-22.

4.0.100.3 SONGS Unit 1 Fuel shall not be stored in Region I Racks.

4.0.100.4 The burnup of each SONGS Unit I uranium dioxide spent fuel assembly stored in Region II. shall meet the following criteria:.

SAN ONOFRE--UNIT 3 4.0-100-1 Rev . 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued) 4.0.100.4.1 SONGS Unit I nominal 3.40 w/o assemblies can be stored in the Region II Racks, (unrestricted) if:

the burnup is greater than 25,000 MWD/T, and the cooling time is greater than 5 years.

4.0.100.4.2 SONGS Unit 1 nominal 4.00 w/O assemblies can be stored in the Region II Racks (unrestricted) if:

the burnup is greater than 26,300 MWD/T, and the cooling time is greater than 20 years.

the burnup is greater than 27,100 MWD/T, and the cooling time is greater than 15 years.

the burnup is greater than 28,200 MWD/T, and the cooling time is greater than 10 years.

4.0.100.4.3 SONGS Unit 1 nominal 4.00 w/o assemblies can be stored in the Region II Racks (SFP periphery) if:

the burnup is greater than 20,000 MWD/T, and the cooling time is greater than 0 years.

4.0.100.5 Design Requirements For Guide Tube Inserts (i) GT-Inserts shall be 0.75 inches O.D. minimum, completely cover the active fuel region (150 inches),

and have a minimum boron content of 0.02434 grams of B-10 per cm3 .

0ii) Three (3) or 5 GT-Inserts are, allowed. The orientation of every fuel assembly with 3 guide tube inserts shall be the same (Figure 11-23).

(iii) A 5-finger, full length Control Element Assembly (CEA) may be used in place of borated stainless steel or aluminum guide tube inserts.

4.0.100.6 Design requirements For Erbia Assemblies containing 40 or 80 erbia rods shall have the erbia rods distributed per Figures 11-24 and 11-25. The minimum initial nominal erbia loading shall be 2.0 w/o Er203.

4.0.100.7 The Failed Fuel Rod Storage Basket (FFRSB)

The Failed Fuel Rod Storage Basket (FFRSB) shall be treated as if it were an assembly with enrichment and burnup of the rod in the basket with the most limiting combination of enrichment and burnup.

SAN ONOFRE--UNIT 3 4.0-100-2 Rev. 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued) 4.0.100.8 Non-Fuel Components Neutron sources and non-fuel bearing assembly components (thimble plugs, CEAs, etc) may be stored in fuel assemblies without affecting the storage requirements of these assemblies. A storage basket containing no fissile material can be stored in any storage location, and can be used as a storage cell blocker for reactivity control.

4.0.100.9 Fuel Assembly Reconstitution Station A fuel assembly reconstitution station is a special case of a checkerboard pattern. A reconstitution station is permitted anywhere in the Region I racks. The empty cells in the checkerboard pattern do not need to be blocked. A reconstitution station is permitted anywhere in the Region II racks provided that empty cells in the checkerboard pattern are blocked to make it impossible to misload a fuel assembly during reconstitution activities.

SAN ONOFRE--UNIT 3 4.0-100-3 Rev. 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Table 1-1 REGION I Category I-i Fuel (Unrestricted Storage)

Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o 0 Years 5 Years 10 Years 15 Years 20 Years Cooling Cooling Cooling Cool ing Cooling 5.00 22.84 21.47 20.59 20.04 19.67 4.50 18.61 17.57 16.89 16.45 16.17 4.00 14.30 13.58 13.09 12.78 12.57 3.50 9.84 9.40 9.11 8.92 8.79 3.00 5.24 5.02 4.91 4.84 4.79 2.47 0.00 0.00 0.00 0.00 0.00 Category Category I-i C -i Category Category I-I I-1 Note: Category I-I and fresh fuel with full-length 5-finger CEAs (Table 1-5) may be stored together with no restrictions.

SAN ONOFRE--UNIT 3 4.0-100-4 Rev. 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Table 1-2 REGION I Category 1-2 Fuel (SFP Peripheral Storage)

Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cooling Cool ing Cooling Cool ing Cooling 5,00 12.55 12.15 11.82 11.61 11.47 4.50 9.09 8.85 8.63 8.49 8.40 4.00 5.58 5.43 5.33 5.25 5.21 3.50 2.22 2.13 2.09 2.05 2.03 3,20 0.00 0.00 0.00 0.00 0.00 P P 0 0 0 0 L L Category Category Category 0 0 0 Category Category Category 1-2 1-1 1-I I-I II-1-2 W W A 0 A L 0 L L L 0 0 0 Category Category Category 1-2 1-2 1-2 POOL WALL SAN ONOFRE--UNIT 3 4.0-100-5 Rev. 2. 09127107

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Table 1-3 REGION I Category 1-3 Fuel (Filler Assembly For 1-out-of-4 Pattern)

Initial Minimum Burnup (GWD/T)

Enrichment (W/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cooling Cooling Cool ing Cooling Cooling 5.00 39.99 36.28 34.27 33.04 32.22 4.50 34.95 31.71 29.94 28.84 28.12 4.00 29.71 26.99 25.46 24.51 23.89 3.50 24.22 22.03 20.79 20.02 19.52 3.00 18.37 16.84 15.91 15.34 14.97 2.50 12.21 11.30 10.72 10.37 10.13 2.00 5.28 5.05 4.85 4.72 4.62 1.71 0.00 0.00 0.00 0.00 0.00 4.80 Category Fresh 1-3 Category Category 1-3 1-3 SAN ONOFRE--UNIT 3 4.0-100-6 Rev. 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Table 1-4 REGION I 4.80 w/o Fresh Fuel Checkerboard Pattern Initial Minimum Burnup (GWD/T)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cooling Cooling Cool ing Cooling Cooling 4.80 0.00 0.00 0.00 0.00 0.00 4.80 Empty Fresh Empty 4.80 Fresh SAN ONOFRE--UNIT 3 4.0-100-7 Rev. 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Table I-5 REGION I 4.8 w/o Fresh Fuel With Full-Length, 5-Finger CEA (Unrestricted Storage)

Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cool i ng Cool ing Cooling Cooling Cooling 4.80 0.00 0.00 0.00 0.00 0.00 4.80 4ý.80 Fresh Fresh With CEA With CEA 4.80 4.80 Fresh Fresh With CEA With CEA Note: Category'l-i and fresh fuel with full-length 5-finger CEAs (Table 1-5) may be stored together with no restrictions.

SAN ONOFRE--UNIT 3 4.0-100-8 Rev. 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Table 1-6 REGION I Category ]-4 Fuel (Filler Assembly For 1-out-of-4 Pattern)

Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cool i ng Cooling Cool ing Cool ing Cooling 5.00 26.57 24.71 23.59 22.90 22.44 4.50 22.12 20.62 19.73 19.17 18.80 4.00 17.54 16.46 15.78 15.35 15.07 3.50 12.84 12.12 11.66 11.37 11.18 3.00 7.95 7.56 7.31 7.15 7.05 2.50 2.76 2.64 2.56 2.50 2.46 2.27 0.00 0.00 0.00 0.00 0.00 4.80 Category Fresh 1-4 80 Erbia Category Category 1-4 1-4 SAN ONOFRE--UNIT 3 4.0-100-9 Rev. 2. 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Table 1-7 REGION I Category 1-5 Fuel (Filler Assembly For 1-out-of-4 Pattern)

Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cooling Cool ing Cooling Cool ing Cooling 5.00 30.81 28.40 27.00 26.14 25.57 4.50 26.17 24.17 22.99 22.26 21.78 4.00 21.32 19.77 18.84 18.27 17.88 3.50 16.32 15.22 14.55 14.13 13.85 3.00 11.11 10.45 10.05 9.79 9.61 2.50 5.55 5.30 5.14 5.04 4.98 2.07 0:00 0.00 0.00 0.00 0.00 4.80 Category Fresh 1-5 40 Erbia Category Category 1-5 1-5 SAN ONOFRE--UNIT 3 .4.0-100-10 Rev. 2 09/27/07 1

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Table 1-8 REGION I Checkerboard Pattern Category 1-6 Fuel (4.80 w/o Assembly Depleted to 18.0 GWD/MTU)

Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cooling Cooling Cooling Cooling Cooling 5.00 19.82 18.84 18.12 17.67 17.37 4.50 15.83 15.11 14.58 14.24 14.01 4.00 11.75 11.28 10.92 10.69 10.54 3.50 .7.56 7.23 7.04 6.91 6.83 3.00 3.28 3.15 3.07 3.03 2.99 2.65 0.00 0.00 0.00 0.00 0.00 Category 1-4 Fuel (Checkerboard Partner For Category 1-6 Fuel)

Initial Minimum Burnup (GWD/MTU)

Enrichment (W/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cool ing Cool ing Cooling Cooling Coo ling 5.00 26.57 24.71 23.59 22.90 22.44 4.50 22. 12 20.62 19.73 19.17 18.80 4.00 17.54 16.46 15.78 15.35 15.07 3.50 12.84 12.12 11.66 11.37 11.18 3.00 7.95 7.56 7.31 7.15 7.05 2.50 2.76 2.64 2.56 2.50 2.46 2.27 0.00 0.00 0.00 0.00 0.00 Category Category 1-4 1-6 Category Category 1-6 1-4 SAN ONOFRE--UNIT 3 4.0-100-11 Rev . 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Table 11-1 REGION II Category 11-1 Fuel (Unrestricted Storage)

Initial Minimum 8urnup (GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cooling Cooling Cool ing Cooling Cooling 5,00 53.76 47.77 44.75 43.00 41.86 4.50 48.43 42.93 40.15 38.52 37.47 4.00 42.91 37.94 35.40 33.92 32.96 3.00 30.99 27.26 25.30 24.16 23.43 2.00 17.05 14.97 13.90 13.25 12.83 1.87 14.93 13.23 12.26 11.68 11.31 1.23 0.00 0.00 0.00 0.00 0.00 Category Category It-i C 1-i Category Category II-1 II-1 Note: Category 11-1, 11-8, 11-9, and 11-15 may be stored together with no restrictions.

SAN ONOFRE--UNIT 3 4.0-100-12 Rev . 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Table 11-2 REGION II, Category 11-2 Fuel (SFP Peripheral Storage)

Initial Minimum Burnup GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cooling Cooling Cooling Cooling Cooling 5.00 36.95 33.68 31.89 30.81 30.10 4.50 32.29 29.44 27.87 26.91 26.28 4.00 27.44 25.04 23.70 22.88 22.35 3.00 16.95 15.62 14.83 14.34 14.03 2.00 4.93 4.67 4.52 4.42 4.35 1.87 3.04 2.87 2.76 2.69 2.64 1.70 0.00 0.00 0.00 0.00 0.00 P P 0 0 0 0 L _L Category Category Category o o o Category Category Category 11-2 11-1 1I -I 11III 11-2 W W A o A L o L L o L Category Category Category o o o Category Category Category 1-2 11-2 11-2 11-2 11-2 11-4 POOL WALL SAN ONOFRE--UNIT 3 4.0-100-13 Rev. 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Table 11-3 REGION II Checkerboard Storage Category 11-3 Fuel (Checkerboard Partner For Category 11-4 Fuel)

Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cool i ng Cooling Cooling Cooling Cooling 5.00 41.18 37.27 35.18 33.93 33.12 4.50 36.34 32.87 31.01 29.88 29.15 4.00 31.29 28.31 26.69 25.70 25.06 3.00 20.32 18.50 17.47 16.84 16.42 2.00 7.81 7.25 6.91 6,71 6.58 1.87 5.90 5.53 5.30 5.17 5.09 1.56 0.00 0.00 0.00 0.00 0.00 Category 11-4 Fuel (Checkerboard Partner For Category 11-3 Fuel)

Initial Minimum Burnup (GWD/MTU)

.Enri chment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cool ing Cooling Cooling Cooling Cooling 5.00 75.42 61.90 56.85 54.18 52.60 4.50 68.08 56.12 51.65 49.25 47.76 4.00 60.74 50.35 46.44 44.19 42.78 3.00 46.06 38.80 35.41 33.52 32.31 2 .00 31.38 25.71 23.12 21.65 20.71 1.87 29.19 23.83 21.34 19.91 19.08 0.94 0.00 0.00 0.00 0.00 0.00 Category Category 11-4 11-3 Category Category 11-3 11-4 SAN ONOFRE--UNIT 3 4.0-100-14 Rev . 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Table 11-4 REGION II Checkerboard Storage Category 11-5 Fuel (Checkerboard Partner For Category 11-6 Fuel)

Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cooling Cool i ng Cooling Cooling Cooling 5.00 47.50 42.58 40.03 38.53 37.55 4.50 42.40 37.95 35.64 34.26 33.37 4.00 37.10 33.16 31.10 29.86 29.06 3.00 25.64 22.89 21.40 20.52 19.95 2.00 12.29 11.10 10.42 10.01 9.75 1.87 10.24 9.35 8.80 8.46 8.25 1.38 0.00 0.00 0.00 0.00 0.00 Category 11-6 Fuel (Checkerboard Partner For Category 11-5 Fuel)

Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cooling Cooling Cool ing Cooling Cooling 5.00 62.37 53.95 50.33 48.25 46.91 4.50 56.21 48.90 45.51 43.56 42.31 4.00 50.04 43.67 40.54 38.73 37.57 3.00 37.71 32.56 29.97 28.52 27.58 2.00 23.30 19.80 18.13 17.14 16.50 1.87 21.11 18.02 16.42 15.48 14.88 1.08 0.00 0.00 0.00 0.00 0.00 Category Category 11-6 11-5 Category Category 11-5 11-6 SAN ONOFRE--UNIT 3 4.0-100-15 Rev. 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES. (continued)

Table 11-5 REGION II Checkerboard Storage Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cool ing Cool ing Cooling Cooling Cooling 4.80 0.00 0.00 0.00 0.00 0.00 4.80 Empty Fresh (Blocked)

Empty 4.80 (Blocked) Fresh SAN ONOFRE--UNIT 3 4.0-100-16 Rev. 2 09/27/07 1

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Table 11-6 REGION II Category 11-7 Fuel (3 Out Of 4 Pattern)

Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cooling Cool ing Cool ing Cooling Cooling 5.00 34.20 31.35 29.74 28.76 28.12 4.50 29.67 27.21 25.82 24.97 24.41 4.00 24.94 22.92 21.75 21.05 20.59 3.00 14.79 13.76 13.13 12.73 12.47 2.00 3.16 3.00 2.90 2.83 2.79 1.87 1.21 1.14 1.09 1.06 1.04 1.80 0.00 0.00 0.00 0.00 0.00 Category Empty 11-7 (Blocked)

Category Category 11-7 11-7 SAN ONOFRE--UNIT 3 4.0-100-17 .Rev. 2 09/27/07

Fuel Storage Patterns LCS 4.0..100 4.0 DESIGN FEATURES (continued)

Table 11-7 REGION II Category 11-8 Fuel (Fuel With 5 GT-Inserts)

(Unrestricted Storage)

Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cool i ng Cool i ng Cool i ng Cool ing Cooling 5.00 37.68 34.53 32.72 31.61 30.88 4.50 32.61 29.90 28.33 27.36 26.72 4.00 27.33 25.10 23.78 22.97 22.43 3.00 15.86 14.76 14.06 13.61 13.32 2.00 2.04 1.97 1.89 1.84 1.81 1.90 0.00 0.00 0.00 0.00 0.00 Category Category 11-8 11-8 Category Category 11-8 11-8 Note: Category I-1, 11-8, 11-9, and 11-15 may be stored together with no restrictions.

SAN ONOFRE--UNIT 3 4.0-100-18 Rev . 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Table 11-8 REGION II Category 11-9 Fuel (Fuel With 3 GT-Inserts)

(Unrestricted Storage)

Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cooling Cooling Cooling Cooling Cooling 5.00 44.16 39.95 37.68 36.31 35.42 4.50 38.99 35.25 33.22 31.99 31.18 4.00 33.61 30.38 28.60 27.52 26.81 3.00 21.92 19.86 18.72 18.01 17.56 2.00 8.28 7.72 7.34 7.11 6.96 1.87 6.18 5.83 5.58 5.43 5.34 1.59 0.00 0.00 0.00 0.00 0.00 Category Category 11-9 II-9 Category Category 11-9 11-9 Note: Category 11-1, 11-8, 11-9, and 11-15 may be stored together with no restrictions.

SAN ONOFRE--UNIT 3 4.0-100-19 Rev. 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Table 11-9 REGION II Category 11-10 Fuel (Filler Assembl.y With 5 Guide Tube Inserts)

Initial Minimum Burnup (GWD/MTU)

(w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cooling Cool ing Cool ing Cooling Cooling 5.00 80.09 65.66 60.12 57.45 55.68 4.50 72.13 59.43 54.55 52.02 50.33 4.00 64.18 53.19 48.98 46.58 44.98 3.00 48.27 40.72 3.7.16 35.03 33.75 2.00 32.35 26.59 23.79 22.25 21.25 1.03 0.00 0.00 0.00 0.00 0.00 Category Category Category 11-10 11-10 11-10 (GT-Inserts) (GT-Inserts) (GT-Inserts)

Category 4 .80 Category 11-io Fresh 11-10 (GT-Inserts) (GT-Inserts)

Category Category Category 1f-t0 II-sr ( I-10 (GT-Inserts) (GT-Inserts) (GT-Inserts)

SAN ONOFRE--UNIT 3 4.0-100-20 Rev. 2 09/27/07 1

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Table II-10 REGION II.

Category II-11 Fuel (Filler Assembly With 5 Guide Tube Inserts)

Initial Minimum Burnup (GWD/MTU)

Enri chment (W/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cooling Cool ing Cooling Cooling Cooling 5.00 47.04 42,52 40.05 38.57 37.60 4.50 41.62 37.58 35.36 34.02 33.14 4.00 35.97 32.46 30.50 29.32 28.54 3.00 23.70 21.42 20.09 19.31 18.79 2.00 9.17 8.54 8.09 7.81 7.62 1.59 0.00 0.00 0.00 0.00 0.00 Category Category Category 11-11 11-11 11-11 (GT-Inserts) (GT-Inserts) (GT-Inserts)

Category 4 .80 Category Il-11 Fresh i1-11 (GT-Inserts) 5 Inserts (GT-Inserts)

Category Category Category I]-I 1 II-11 II-11 (GT-Inserts) (GT-Inserts) (GT-Inserts)

SAN ONOFRE--UNIT 3 4.0-100-21 Rev . 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Table 11-11 REGION II Category 11-12 Fuel (Filler Assembly With 3 GT-Inserts)

Initial Minimum Burnup '(GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cooling Cooling Cool ing Cooling Cooling 5.00 54.33 48.48 45.46 43.67 42.51 4.50 48.81 43.45 40.67 39.02 37.95 4.00 43.07 38.24 35.72 34.22 33.26 3.00 30.65 27.11 25.18 24.05 23.33 2.00 16.01 14.23 13.22 12.62 12.22 1.87 13.82 12.35 11.47 10.94 10.60 1.32 0.00 0.00 0.00 0.00 0.00 Category Category Category 11-12 11-12 11-12 (GT-Inserts) (GT-Inserts) (GT-Inserts)

Category 4.80 Category 11-12 Fresh 11-12 (GT-Inserts) 5 Inserts (GT-Inserts)

Category Category Category 11-12 11-12 11-12 (GT-Inserts) (GT-Inserts) (GT-Inserts)

SAN ONOFRE--UNIT 3 4.0-100-22 Rev . 2 09/27./07 1

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Table 11-12 REGION II Category 11-13 Fuel (Filler Assembly With No GT-Inserts)

Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cooling Cooling Cool ing Cooling Cooling 5,00 64.24 55.51 51.59 49.41 48.03 4,50 57.99 50.23 46.73 44.67 43.38 4.00 51.75 44.94 41.71 39.79 38.59 3,00 39.25 33.75 31.05 29.48 28.50 2.00 24.76 20.95 19.07 18.01 17.33 1.87 22.64 19.10 17.38 16.37 15.72 1,05 0.00 0.00 0.00 0.00 0.00 Category Category Category 11-13 11-13 11-13 4.80 Category Category 11-13 Fresh 11-13 5 Inserts Category Category Category 11-13 11-13 11-13

-f SAN ONOFRE--UNIT 3 4.0-100-23 Rev. 2 09/27/07 1

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Table 11-13 REGION II Category 11-14 Fuel (4.80 w/o Assembly Depleted to 18.0 GWD/MTU)

Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cooling Cooling Cool ing Cooling Cooling 5.00 19.59 18.61 17.96 17.54 17.27 4.50 15.93 15.17 14.68 14.36 14.15 4.00 12.18 11.64 11.29 11.07 10.93 3.00 4.28 4.12 4.05 4.00 3.98 2.51 0.00 0.00 0.00 0.00 0.00 Category 11-13 Fuel (Filler Assembly For Category 11-14 Fuel)

Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cooling Cooling Cooling, Cooling Cooling 5.00 64.24 55.51 51.59 49.41 48.03 4.50 57.99 50.23 46.73 44.67 43.38 4.00 51.75 44 94 41.71 39.79 38.59 3.00 39.25 33.75 31.05 29.48 28.50 2.00 24.76 20.95 19.07 18.01 17.33 1.87 22.64 19. 10 17.38 16.37 15.72 1.05 0.00 0.00 0.00 0.00 0.00 Category Category Category 11-13 11-13 11-13 Category Category Category 11-13 1 1-14 11-13 Category Category Category 11-13 11-13 11-13 SAN ONOFRE--UNIT 3 4.0-100-24 Rev. 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Table 11-14 REGION II Category 11-14 Fuel (4.80 w/o Assembly Depleted to 18.0 GWD/MTU)

Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cooling Cool i ng Cool ing Cooling Cooling 5.00 19.59 18.61 17.96 17.54 17.27 4.50 15.93 15.17 14.68 14.36 14.15 4.00 12.18 11.64 11.29 11.07 10.93 3.00 4.28 4.12 4.05 4.00 3.98 2.51 0.00 0.00 0.00 0.00 0.00 Category 11-11 Fuel (Filler Assembly With 5 Guide Tube Inserts)

Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cooling Cool i ng Cooling Cooling Cooling 5.00 47.04 42.52 40.05 38.57 37.60 4.50 41.62 37.58 35.36 34.02 33.14 4.00 35.97 32.46 30.50 29.32 28.54 3.00 23.70 21.42 20.09 19.31 18.79 2.00 9.17 8.54 8.09 7.81 7.62 1.59 0.00 0.00 0.00 0.00 0.00 Category Category Category 11-11 11-11 11-11 (5 Inserts) (5 Inserts) (5 Inserts)

Category Category Category Il-11 1I-11 (5 Inserts) 1- 14 (5 Inserts)

Category Category Category I -11 11-11 II-11 (5 Inserts) (5 Inserts) (5 Inserts)

SAN ONOFRE--UNIT 3 4.0-100-25 Rev . 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Table 11-15 REGION II Category 11-15 Fuel (Fuel With 5 Finger Full Length CEA)

(Unrestricted Storage)

Initial Minimum Burnup (GWD/MTU)

Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Cool ing Cooling Cooling Cooling Cooling 5.00 29.24 27.24 26.00 25.22 24.70 4.50 24.44 22.84 21.81 21.17 20.75 4.00 19.41 18.26 17.49 17.00 16.68 3.00 8.83 8.47 8.19 8.02 7.90 2.30 0.00 0.00 0.00 0.00 0.00 Category Category 11-15 11-15 Category Category 11-15 11-15 Note: Category 11-1, 11-8, 11-9, and 11-15 may be stored together with no restrictions.

SAN ONOFRE--UNIT 3 4.0-100-26 Rev. 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure I-i REGION I MINIMUM BURNUP FOR CATEGORY 1-1 FUEL 25 "15 001 0 -

2.0 2.5 3.0 3.5 4.0 4.5 5.0 Initial U-235 Enrichment (w/o)

- 0 Yeare-- 5 Year.;e- 10 Yea%- 15 Yea4m- 20 Years SAN ONOFRE--UNIT 3 4.0-100-27 Rev. 2 09/27/07 1

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 1-2 REGION I MINIMUM BURNUP FOR CATEGORY 1-2 FUEL 15-

_10 Acceptable Region m

-e 0 Unacceptable Region U-3.0 3.5 4.0 4.5 5.0 Initial U,235 Enrich~rment (w/o) eO0Years G 5 Years z* 10 Years 15 Years 11 20 Years SAN ONOFRE--UNIT 3 4.0-100-28 Rev. 2 09/27/07 1

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 1-3 REGION I MINIMUM BURNUP FOR CATEGORY 1-3 FUEL SAN ONOFRE--UNIT 3 4.0-100-29 Rev . 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 1-4 REGION I MINIMUM BURNUP FOR CATEGORY 1-4 FUEL 30 20o . Acceptable Region CL co 15 __ - - _- - - -

E " I (n 10 -----

z~- Unacceptable Region LL 5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Initial U-235 Enrichment (w/o) 0 Years - 5 Years v, 10 Years 4-, 15 Years - 20 Years SAN ONOFRE--UNIT 3 4.0-100-30 Rev. 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 1-5 REGION I MINIMUM BURNUP FOR CATEGORY 1-5 FUEL 35 S25ý- Acceptable Region m

(D

-* 15 0 - ___ --

-_3 Unacceptable

5. Region 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Initial U-235 Enrichment (w/o)

-8 0 Years e 5 Years -z 10 Years - 15 Years x 20 Years SAN ONOFRE--UNIT 3 4.0-100-31 Rev. 2 09/27/07 1

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 1-6 REGION I MINIMUM BURNUP FOR CATEGORY 1-6 FUEL P

-0 E

Zi oL-2.5 3.0 3.5 4.0 4.5 5.0 Initial U-235 Enrichmenl (w/o) e 0 Years e 5 Years zF 10 Years - 15 Years E- 20 Years SAN ONOFRE--UNIT 3 4.0-100-32 Rev. 2 09/27/07 1

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 1-7 REGION I Boundary Between Unrestricted Storage And Checkerboard Storage I- E I-1 I-1 I-1 I-1 I-1 I-1 I-1 I-1 I-1 I-1 I-i I-1 I-1 I-1 1-1 I-1 I-1 I-1 Empty I-1 I-1 I-1 I-1 Empty 4.80 Empty I-1 1-1 -1 4.80 Empty 1-1 I-1 I-i I-I II I Interface I-i I-I I-I I-I I-I I-i 1-1 1-4 I-I I-1 1-1 I-i I-I I-i 1-1 I-I I-1 I-1

[ I-I 1-4 I-] I-I I-1 1-i 1-4 1-6 1-4 I-1 I-I I-i 1-6 1-4 I-1 I-1 1-1 I-1 Interface Note: 1) A row of empty cells can be used at the interface to separate the configurations.

(2) It is acceptable to replace an assembly with an empty cell.

SAN ONOFRE--UNIT 3 4.0-100-33 Rev. 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 1-8 REGION I Boundary Between Unrestricted Storage And 1 Out Of 4 Storage Interface Note: (1) A row of empty cells can be used at the interface to separate the configurations.

(2) It is acceptable to replace an assembly with an empty cell.

SAN ONOFRE--UNIT 3 4.0-100-34 Rev. 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 1-9 REGION I Boundary Between Checkerboard Storage And 1 Out Of 4 Storage 4.80 Empty 4.80 Empty 4.80 Empty Empty 4.80 Empty 4.80 Empty 4.80 4.80 Empty 4.80 Empty 4.80 Empty Empty 1-3 Empty 4.80 Empty 4.80 1-3 4.80 1-3 Empty 4.80 Empty 1-3 I-3 Empty 4.80 Empty 4.80 II II Interface Interface Note: (1) A row of empty cells can be used at the interface to separate the configurations.

(2) It is acceptable to replace an assembly with an empty cell.

SAN ONOFRE--UNIT 3 4.0-100-35 Rev. 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure I1-i REGION II MINIMUM BURNUP FOR CATEGORY 11-1 FUEL 60

- 50

(-40 E

m 30 E

a) w 20 0)

LL1 0 2 3 4 5 Initial U-235 Enrichment (w/o)

-- 0 Years e 5 Years ---- 10 Years l- 15 Years 20 Years SAN ONOFRE--UNIT 3 4.0-100-36 .Rev. 2 09/27/07

Fuel Storage Patterns

  • LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 11-2 REGION II MINIMUM BURNUP FOR CATEGORY 11-2 FUEL 40 E

10 0-1.5 2 2.5 3 3.5 4 4.5 5 Initial U-235 Enrichment (w/o)

- 0 Years Eý 5 Years --- 10 Years ýF 15 Years -s- 20 Years SAN ONOFRE--UNIT 3 4.0-100-37 Rev. 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 11-3 REGION II MINIMUM BURNUP FOR CATEGORY 11-3 FUEL 50 40 S30 E20-0-

1.5 2 2.5 3 3.5 4 4.5 5 Initial U-235 Enrichment (w/o)

-ý 0 Years ---- 5 Years -- >-- 10 Years ;-- 15 Years -- 20 Years SAN ONOFRE--UNIT 3 4.0-100738 Rev. 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 11-4 REGION I1 MINIMUM BURNUP FOR CATEGORY 11-4 FUEL 80 060 0

c40

-0 E

-20 LL 0*

2 3 4 5 Initial U-235 Enrichment (w/o) 0 Years -ý 5 Years -10 Years  ;- 15 Years is- 20 Years SAN ONOFRE--UNIT 3 4.0-100-39 Rev . 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 11-5 REGION 11 MINIMUM BURNUP FOR CATEGORY 11-5 FUEL 50 E40 E 330 E 20 a) 0" 1 2 3 4 5 Initial U-235 Enrichment (w/o) z- 0 Years 9 5 Years ---- 10 Years -. 15 Years - 20 Years SAN ONOFRE--UNIT 3 4.0-100-40 Rev. 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 11-6 REGION II MINIMUM BURNUP FOR CATEGORY 11-6 FUEL 70 60-

~50--

0 z 40--

30 30

< 20 U-10 0

I 2 3 45 Initial U-235 Enrichment (w/o) 0 Years 5 Years -'- 10 Years !- 15 Years ---- 20 Years SAN ONOFRE--UNIT 3 4.0-100-41 Rev . 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 11-7 REGION II MINIMUM BURNUP FOR CATEGORY 11-7 FUEL 35.

30 Zý25-E 20-S15-E a)

W)

< 10-LL 5.

0-1 1.5 2 2.5 3 3.5 4 4.5 5 Initial U-235 Enrichment (w/o) 0 Years E- 5 Years --- 10 Years - 15 Years -E- 20 Years SAN ONOFRE--UNIT 3 4.0-100-'42 Rev. 2. 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 11-8 REGION II MINIMUM BURNUP FOR CATEGORY 11-8 FUEL 40 n30 0..

O 20 E

10.

U-0 1.5 2 2.5 3 3.5 4 4.5 5 Initial U-235 Enrichment (w/o)

Eý 0 Years E- 5 Years 10 Years 15 Years :E 20 Years SAN ONOFRE--UNIT 3 4.0-100-43 Rev. 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 11-9 REGION 11 MINIMUM BURNUP FOR CATEGORY 11-9 FUEL 50 E'40 (D

  • 30 E 20-a) u 0-1.5 2 2.5 3 3.5 4 4.5 5 Initial U-235 Enrichment (w/o) 0 Years -E- 5Years lOYears 0 -ý- 155Years F-- 20 Years SAN ONOFRE--UNIT 3 4.0-100-44 Rev . 2 09/27/07 1

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 11-10 REGION 11 MINIMUM BURNUP FOR CATEGORY 11-10 FUEL 100 80 0

60 M.

E 40 En U-20 0

S2 3 4 5 Initial U-235 Enrichment (w/o)

-0 Years - 5 Years - 10 Years - 15 Years L; 20 Years SAN ONOFRE--UNIT 3 4.0-100-45 Rev. 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 11-11 REGION II MINIMUM BURNUP FOR CATEGORY II-11 FUEL 50 40 9-30 co E 20

)0 cn "L10 1.5 2 2.5 3 3.5 4 4.5 5 Initial U-235 Enrichment (w/o)

-n- 0 Years 5 Years 10 Years -;;; 15 Years E- 20 Years SAN ONOFRE--UNIT 3 4.0-100-46 Rev . 2 09/27/07

Fuel Storage Pattern~s LCS 4.0.1I0' 4.0 DESIGN FEATURES (continued)

Figure 11-12 REGION II MINIMUM BURNUP FOR CATEGORY 11-12 FUEL 60 50-r)

(0 40 CL m30

.0 E

20 LL.

10 0

1 2 3 4 5 Initial U-235 Enrichment (w/o) 0 Years -e-- 5 Years - 1Years 1-4-- ;7 15 Years iý 20 Years SAN ONOFRE--UNIT 3 4.0-100-47 Rev. 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 11-13

. REGION II MINIMUM BURNUP FOR CATEGORY 11-13 FUEL 70 60 50 CD 40 co "B30 E

0)

V)

V)

< 2-10-0--

12 3 4 5 Initial U-235 Enrichment (w/o) 0 Years - 5 Years -- 10 Years -t- 15 Years -- 20 Years SAN ONOFRE--UNIT 3 4.0-100-48 Rev. 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 11-14 REGION II MINIMUM BURNUP FOR CATEGORY 11-14 FUEL 20 0 15.

(D co 10-

.0 a1)

V),

a) 5 0

2.5 3 3.5 4 4.5 5 Initial U-235 Enrichment (w/o)

-i 0 Years e 5Years --- 10 Years - 15 Years ---- 20 Years SAN ONOFRE--UNIT 3 4.0-100-49 Rev . 2 09/27/07

Fuel Storage Patterns LCS 4;0.100 4.0 DESIGN FEATURES (continued)

Figure 11-15 REGION 11 MINIMUM BURNUP FOR CATEGORY 11-15 FUEL

-25

~20 S15 E

10)

U-2.2 2.7 3.2 3.7 4.2 4.7 Initial U-235 Enrichment (w/o) 0 Years Eý 5 Years - 10Years 10- -v- 15 Years -a- 20 Years SAN ONOFRE--UNIT 3 4.0-100-50 Rev. 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 11-16 REGION II Boundary Between Unrestricted Storage And Checkerboard Storage 11-i 11-I Il-] II-i fl-i If-i II- T Blocked 1-I 111-i 11-i 11-i Blocked 4.80 Blocked II-1 I1-I Il-i 4.80 Blocked 11-1 11-I 11-i 11-1 II II Interface 1I-i 11-1 II-i II-i 11-i 11-1 If-i 11-i 11-i II-1 11-i 11-i 11-i 11-4 11-I 11-I 11-i 11-1 Il-4 11-3 11-4 I1-I 11-i 11-I 11-4 11-3 11-1 11-1 Il-i II II Interface Note: (1) A row of empty cells can be used at the interface to separate the configurations.

(2)- It is acceptable to replace an assembly with an 'empty cell.

SAN ONOFRE--UNIT 3 4.o-100-51 Rev. 2 09/27/07 1

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 11-17 REGION II Boundary Between Unrestricted Storage And 3 Out Of 4 Storage II-I :I-i II-i II-I 11.-I II-I II-i II-I II-I II-I II-i II-i Il-I II-i TI-i II-i II-I II-i Blocked Il-i Blocked 11-i Il-i II-i 11-7 11-7 TI-1 11-1 TI-I I-i Blocked 11-7 Blocked I-1i 1I-i I-I Interface II II Note: (1) A row of empty cells can be used at the interface to separate the configurations.

(2) It is acceptable to replace an assembly with an empty cell.

SAN ONOFRE--UNIT 3 4.0-100-52 Rev. 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 11-18 REGION II Boundary Between Checkerboard Storage And 3 Out Of 4 Storage 11-7 Blocked 11-7 Blocked 11-7 Blocked 11-7 11-7 11-7 11-7 11-7 11-7 11-7 Blocked 11-7 Blocked 11-7 Blocked Blocked 11-7 Blocked 11-7 11-7 11-7 4.80 Blocked 11-7 Blocked 11-7 Blocked Blocked 4.80 Blocked 1I-7 11-7 11-7 Interface Note: (1) A row of empty cells can be used at the interface to separate the configurations.

(2) It is acceptable to replace an assembly with an empty cell.

SAN ONOFRE--UNIT 3 4.0-100-53 Rev. 2 09/27/07 1

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure lI-I9 REGION II Boundary Between I-Out-Of-9 Storage And Unrestricted Storage 11-i 11-1 11-1 I1-i 11-1 I1-i 11-1 II-i Il-I 11.-I II-i I1-i lI-i II-I 11-1 II-i 11-i 11-I Filler Filler Filler LI-I II-I Il-1 Filler A Filler II-I 11-1 11-I Filler Filler Filler II-i II-i II-1 Interface II Where: (1) If A = 4.80 w/o + 0 Inserts, Filler = Category 11-10 (2) If A = 4.80 w/o + 5 Inserts, Filler = Category II-11 (3) If A = 4.80 w/o + 5 Inserts, Filler = Category 11-12 (4) If A = 4.80 w/o + 5 Inserts, Filler = Category 11-13 (5) If A = Category 11-14, Filler = Category 11-13 (6) If A = Category 11-14, Filler = Category IT-11 SAN ONOFRE--UNIT 3 4.0-100-54 Rev. 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 11-20 REGION II Boundary Between i-Out-Of-9 Storage And Checkerboard Storage 11-4 11-3 11-4 11-3 11-4 11-3 11-3 11-4 11-3 11-4 11-3 11-4 11-4 11-3 11-4 11-3 11-4 11-3 Filler Filler Filler 11-4 11-3 11-4 Filler A Filler 11-3 11-4 11-3 Filler Filler Filler 11-4 11-3 11-4 Interface Where: (1) If A 4.80 w/o + 0 Inserts, Filler Category II-10 (2) If A 4.80 w/o + 5 Inserts, Filier Category (3) If A 4.80 w/o + 5 Inserts, Filler Category 11-12 (4) If A 4.80 w/o + 5 Inserts, Filler Category 11-13 (5) If A Category 11-14, Filler Category 11-13 (6) If A Category 11-14, Filler Category 1-1II SAN ONOFRE--UNIT 3 4.0-100-55 Rev. 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure JI-21 REGION II Boundary Between I-Out-Of-9 Storage And Checkerboard Storage Blocked 4.80 Blocked 4.80 Blocked 4.80 4.80 Blocked 4.80 Blocked 4.80 Blocked Blocked 4.80 Blocked 4.80 Blocked 4.80 Filler Blocked Filler Blocked 4.80 Blocked Filler A Blocked 4.80 Blocked 4.80 Filler Filler Filler ;Blocked 4.80 Blocked Interface Where: (1) If A = 4.80 w/o + 0 Inserts, Filler = Category 11-10 (2) If A = 4.80 w/o + 5 Inserts, Filler = Category Il-11 (3) If A = 4.80 w/o 7 5 Inserts, Filler = Category 11-12 (4) If A = 4.80 w/o + 5 Inserts, Filler = Category 11-13 (5) If A = Category 11-14, Filler = Category 11-13 (6) If A = Category 11-14, Filler = Category 11-11 SAN QNOFRE--UNIT 3 4.0-100-56 Rev. 2 09/27/07

Fuel Storage Patterns LCS 4.0:100 4.0 DESIGN FEATURES (continued)

Figure 11-22 REGION II Boundary Between 1-Out-Of-9 Storage And 3-Out-Of-4 Storage 11-7 Blocked 11-7 Blocked 11-7 Blocked 11-7 11-7 11-7 11-7 11-7 11-7 11-7 Blocked 11-7 Blocked 11-7 Blocked Filler Filler Filler 11-7 11-7 11-7 Filler A Filler Blocked 11-7 Blocked Filler Filler Filler 11-7 11-7 11-7 Interface Where: (1) If A 4.80 w/o + 0 Inserts, Filler Category 11-10 (2) If A 4.80 w/o + 5 Inserts, Filler Category II-II (3) If A 4.80 w/o + 5 Inserts, Filler Category 11-12 (4) If A 4.80 w/o + 5 Inserts, Filler Category 11-13 (5) If A Category 11-14, Filler Category 11-13 (6) If A Category 11-14, Filler Category II-ii SAN ONOFRE--UNIT 3 4.0-100-57 Rev. 2 09/27/07 1

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 11-23 Orientation Of 3 Guide Tube Inserts Fuel Assembly yyy <--- Serial yI Number yI 00 xx 00 xx xx xx xx 00 xx 00 XX = Guide Tube-With Insert xx 00 = Empty Guide Tube 00 SAN ONOFRE--UNIT 3 4.0-100-58 Rev. 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

.Figure 11-24 SONGS UNITS 2 AND 3 FUEL ASSEMBLY WITH 40 ERBIA RODS 40 Erbia Rods DHigh Enriched Fuel Rod Z Low Enriched Fuel Rod E] Erbia Fuel Rod SAN ONOFRE--UNIT 3 4.0-100-59 Rev. 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 4.0 DESIGN FEATURES (continued)

Figure 11-25 SONGS UNITS 2 AND 3 FUEL ASSEMBLY WITH 80 ERBIA RODS I II j

II I 1.11 80 Erbia Rods D High Enriched Fuel Rod

~ Low Enriched Fuel Rod E] Erbia Fuel Rod SAN ONOFRE--UNIT 3 4.0-100-60 Rev. 2 09/27/07

Fuel Storage Pat-terns LCS 4.0.100 B LCS 4.0.100 Fuel Storage Patterns BASES BACKGROUND The spent fuel storage facility is designed to store either new (nonirradiated) nuclear fuel assemblies, or burned (irradiated) fuel assemblies in a vertical configuration underwater. The storage pool is sized to store 1542 fuel assemblies. Two types/sizes of spent fuel storage racks are used (Region I and Region II). The two Region I racks each contain 156 storage locations each spaced 10.40 inches on center in a 12x13 array. Four Region II storage racks each contain 210 storage locations in a 14x15 array. The remaining two Region II racks each contain 195 locations in a 13x15 array. All Region II locations are spaced 8.85 inches on center.

As described in LCS 4.0.100, "Fuel Storage Patterns" fuel assemblies are stored in the spent fuel racks in accordance with criteria based on initial enrichment, discharge burnup, and cooling time (plutonium decay).

Additionally, LCS 4.0.100 allows the following storage options:

2x2 storage patterns, 3x3 storage patterns, credit for erbia in fresh assemblies, inserted CEAs, and borated stainless steel guide tube inserts (GT-Inserts).

Theeffect of these storage options is to reduce the required discharge burnup of irradiated assemblies and add flexibility jn storing fresh assemblies containing erbia.

Finally, credit for boron is taken to maintain Keff < 0.95.

The storage options allowed by LCS 4.0.100 and credit for soluble boron are needed because the boraflex is assumed to be completely absent. Boraflex erosion/dissolution is an industry problem, and SONGS Units 2 and 3 are affected.

Taking no credit for boraflex for SONGS Units 2 and 3 (continued)

SAN ONOFRE--UNIT 3 4.0-100-61 Rev.. 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 BASES (continued)

BACKGROUND eliminates any boraflex concerns and monitoring programs to (continued) ensure that an adequate amount of boraflex is present will not be needed.

APPLICABLE When soluble boron is credited, the following acceptance SAFETY ANALYSIS criteria apply:

(1) Under normal conditions, the 95/95 neutron multiplication factor (Keff), including all uncertainties, shall be less than 1.0 when flooded with unborated water, and, (2) Under normal and accident conditions, the 95/95 neutron multiplication factor .(Keff), including all uncertainties, shall be less than or equal to 0.95 when flooded with borated water.;

The storage options allowed by LCS 4.0.100 meet acceptance criterion I above. Under normal, non-accident conditions, Keff is less than 1.00 with 0 ppm.

The storage options allowed by LCS 4.0.100 meet acceptance criterion 2 above. Under normal, non-accident conditions, the TS 3.7.17 limit for soluble boron concentration of 2000 ppm will ensure that Keff remains less than or equal to 0.95.

The analytical methods used to demonstrate that the storage options allowed by LCS 4.0.100 meet acceptance criteria 1 and 2 are described in the SONGS Spent Fuel Pool Criticality Analysis (Reference 1).

A fuel assembly could be inadvertently loaded into a spent fuel rack location not al:,lowed by LCS 4.0.100 (e.g., an unirradiated fuel assembly or an insufficiently depleted fuel assembly). However, the negative reactivity effect of the soluble boron compensates for the increased reactivity caused by the postulated accident scenario. For this accident condition, the TS 3.7.17 limit for soluble boron concentration of 2000 ppm will ensure that Keff remains less than or equal to 0.95.

(continued)

SAN ONOFRE--UNIT 3 4.0-100-62 Rev. 2 09/27/07

Fuel Storage Patterns LCS 4.0.100 BASES (continued)

LCS The placement of fuel assemblies within the spent fuel pool according to LCS 4.0.100 ensures that the Keff of the spent fuel pool will always remain < 1.00 under normal, non-accident conditions assuming the pool to be flooded with unborated water. The Keff of the spent fuel pool will always remain

  • 0.95 under normal and accident conditions assuming the pool to be flooded with borated water at 2000 ppm.

APPLICABILITY This LCS applies whenever any fuel assembly is stored in the spent fuel pool.

ACTIONS See the Bases for LCO 3.7.18 A SURVEILLANCE See the Bases for SR 3.7.18.1 REQUIREMENTS REFERENCES 1. Spent Fuel Pool Criticality Analysis, (with no Boraflex and Credit for Soluble Boron), Southern California Edison, San Onofre Nuclear Generating Station Units 2 and 3, Revision 2, April 2007.

(continued)

SAN ONOFRE--UNIT.3 4.0-100-63 Rev. 2 09127107