ML080710005

From kanterella
Jump to navigation Jump to search

License and Technical Specification Page, Issuance of Amendment No. 279, Modify TS 3.1.1.4, Moderator Temperature Coefficient Surveillance Frequency
ML080710005
Person / Time
Site: Arkansas Nuclear 
(NPF-006)
Issue date: 03/31/2008
From:
NRC/NRR/ADRO/DORL/LPLIV
To:
Wang, A B, NRR/DORL/LPLIV, 415-1445
Shared Package
ML080710003 List:
References
TAC MD5515
Download: ML080710005 (2)


Text

3 (4)

EOI, pursuant to the Act and 10 CFR Parts 30, 40 and 70 to receive, possess and use at any time any byproduct, source and special nuclear material as sealed neutron sources for reactor startup, sealed sources for reactor instrumentation and radiation monitoring equipment calibration, and as fission detectors in amounts as required; (5)

EOI, pursuant to the Act and 10 CFR Parts 30, 40 and 70, to receive, possess, and use in amounts as required any byproduct, source or special nuclear material without restriction to chemical or physical form, for sample analysis or instrument calibration or associated with radioactive apparatus or components; and (6)

EOI, pursuant to the Act and 10 CFR Parts 30 and 70, to possess, but not separate, such byproduct and special nuclear materials as may be produced by the operation of the facility.

C.

This renewed license shall be deemed to contain and is subject to conditions specified in the following Commission regulations in 10 CFR Chapter 1; Part 20, Section 30.34 of Part 30, Section 40.41 of Part 40, Sections 50.54 and 50.59 of Part 50, and Section 70.32 of Part 70; and is subject to all applicable provisions of the Act and to the rules, regulations, and orders of the Commission now or hereafter in effect; and is subject to the additional conditions specified or incorporated below:

(1)

Maximum Power Level EOI is authorized to operate the facility at steady state reactor core power levels not in excess of 3026 megawatts thermal. Prior to attaining this power level EOI shall comply with the conditions in Paragraph 2.C.(3).

(2)

Technical Specifications The Technical Specifications contained in Appendix A, as revised through Amendment No.

are hereby incorporated in the renewed license. The licensee shall operate the facility in accordance with the Technical Specifications.

Exemptive 2nd paragraph of 2.C.2 deleted per Amendment 20, 3/3/81.

(3)

Additional Conditions The matters specified in the following conditions shall be completed to the satisfaction of the Commission within the stated time periods following issuance of the renewed license or within the operational restrictions indicated.

The removal of these conditions shall be made by an amendment to the renewed license supported by a favorable evaluation by the Commission.

2.C.(3)(a) Deleted per Amendment 24, 6/19/81.

Renewed License No. NPF-6 Amendment No.

Revised by letter dated July 18, 2007 279 279

ARKANSAS - UNIT 2 3/4 1-5 Amendment No. 34,80,81,94,157,236,

265, REACTIVITY CONTROL SYSTEMS MODERATOR TEMPERATURE COEFFICIENT LIMITING CONDITION FOR OPERATION 3.1.1.4 The moderator temperature coefficient (MTC) shall be within the limits specified in the CORE OPERATING LIMITS REPORT. The maximum upper design limit shall be:
a.

Less positive than +0.5x10-4 'k/k/qF whenever THERMAL POWER is d 70% of RATED THERMAL POWER, and

b.

Less positive than 0.0 'k/k/qF whenever THERMAL POWER is > 70% of RATED THERMAL POWER.

APPLICABILITY:

MODES 1 and 2*#

ACTION:

With the moderator temperature coefficient outside any one of the above limits, be in at least HOT STANDBY within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

SURVEILLANCE REQUIREMENTS 4.1.1.4.1 The MTC shall be determined to be within its limits by confirmatory measurements.

MTC measured values shall be extrapolated and/or compensated to permit direct comparison with the above limits. (Note 1) 4.1.1.4.2 The MTC shall be determined at the following frequencies and THERMAL POWER conditions during each fuel cycle:

a.

Prior to initial operation above 5% of RATED THERMAL POWER, after each fuel loading. (Note 1)

b.

At greater than 5% of RATED THERMAL POWER, within 7 effective full power days (EFPD) of reaching 40 EFPD core burnup.

c.

At greater than 5% of RATED THERMAL POWER, within 7 EFPD of reaching two-thirds of expected core burnup. (Note 2)

  1. See Special Test Exception 3.10.2.

Note 1: For fuel cycles that meet the applicability requirements given in WCAP-16011-P-A, the verification prior to entering MODE 1 may be made using the predicted MTC as adjusted for the measured boron concentration.

Note 2: The MTC determination of surveillance 4.1.1.4.2.c is not required if the results of the tests required in surveillances 4.1.1.4.2.a and 4.1.1.4.2.b are within a tolerance of r 0.16 x 10-4 'k/k/qF from the corresponding design values. For cycles that meet the applicability requirements given in WCAP-16011-P-A, the MTC determination of surveillance 4.1.1.4.2.c is not required if the result of the test required in surveillance 4.1.1.4.2.b is within a tolerance of r 0.16 x 10-4 'k/k/qF from the corresponding design value.

279