From:

Siva Lingam To:

njstring@southernco.com Date:

1/28/2008 8:23:02 AM

Subject:

Re: Vogtle - TS RWST Low Level (GSI 191)

Reference:

LAR to revise TSs 3.3.2 and 3.5.4, SNC Letter NL-07-2168 dated January 9, 2008 (TAC Nos. MD7772 and MD7773)

Please provide your response to the following RAI for the referenced license amendment request.

Siva P. Lingam Project Manager (NRR/DORL/LPL2-1)

Surry and Vogtle Nuclear Stations Location: O8-D5 Mail Stop: O8-G9 Telephone: 301-415-1564 Fax: 301-415-1222 E-mail address: spl@nrc.gov

>>> Kulin Desai 1/25/2008 3:11 PM >>>

Siva, Please send this RAI to the licensee.

Demonstrate that there will be adequate net positive suction head (NPSH) available for all ECCS injection pumps operating during a large break LOCA down to the proposed RWST Low Level before switchover to the sump recirculation mode of operation.

Thanks Kulin CC:

Kulin Desai; Melanie Wong Mail Envelope Properties (479DD736.DC4 : 13 : 35786)

Subject:

Re: Vogtle - TS RWST Low Level (GSI 191)

Creation Date 1/28/2008 8:23:02 AM From:

Siva Lingam Created By:

SPL@nrc.gov Recipients Action Date & Time nrc.gov EBGWPO01.HQGWDO01 Delivered 1/28/2008 8:23:05 AM MCW CC (Melanie Wong)

Opened 1/28/2008 8:54:58 AM nrc.gov OWGWPO03.HQGWDO01 Delivered 1/28/2008 8:23:05 AM KDD CC (Kulin Desai)

Opened 1/28/2008 9:10:47 AM

southernco.com Transferred 1/28/2008 8:23:19 AM njstring (njstring@southernco.com)

Post Office Delivered Route EBGWPO01.HQGWDO01 1/28/2008 8:23:05 AM nrc.gov OWGWPO03.HQGWDO01 1/28/2008 8:23:05 AM nrc.gov southernco.com Files Size Date & Time MESSAGE 1830 1/28/2008 8:23:02 AM Options Auto Delete:

No Expiration Date:

None Notify Recipients:

Yes Priority:

Standard ReplyRequested:

No Return Notification:

None Concealed

Subject:

No Security:

Standard To Be Delivered:

Immediate Status Tracking:

Delivered & Opened