January 28, 2008 Mr. Tom E. Tynan Vice President - Vogtle Vogtle Electric Generating Plant 7821 River Road Waynesboro, GA 30830

SUBJECT:

VOGTLE ELECTRIC GENERATING PLANT, UNIT 2 (VOGTLE), REQUEST FOR ADDITIONAL INFORMATION (RAI) REGARDING THE STEAM GENERATOR TUBE INSPECTION REPORT FOR THE TWELFTH REFUELING OUTAGE, 2R12 (TAC NO. MD7228)

Dear Mr. Tynan:

By letter dated October 12, 2007, Southern Nuclear Operating Company, Inc. (the licensee),

submitted the spring 2007 steam generator (SG) tube inspection report performed at Vogtle 2 during the twelfth refueling outage (2R12). The Nuclear Regulatory Commission (NRC) staff is reviewing the submittal and has determined that additional information is required to complete its evaluation.

The NRC staffs RAI is enclosed. The licensee is required to provide a response to the RAI within 30 days.

Sincerely,

/RA/

Siva P. Lingam, Project Manager Plant Licensing Branch II-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-425

Enclosure:

RAI cc w/encl: See next page

ML080230193

  • transmitted by memo dated OFFICE NRR/LPL2-1/PM NRR/LPL2-1/LA NRR/DCI/CSGB/BC NRR/LPL2-1/BC (A)

NAME SLingam MO=Brien AHiser MWong DATE 1/28/08 1/28/08 1/14/08*

1/28/08

Enclosure REQUEST FOR ADDITIONAL INFORMATION REGARDING THE SPRING 2007 STEAM GENERATOR TUBE INSPECTIONS VOGTLE ELECTRIC GENERATING PLANT, UNIT 2 DOCKET NO. 50-425 By letter dated October 12, 2007 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML072880102), Southern Nuclear Operating Company, Inc.,

(the licensee), submitted information summarizing the results of the spring 2007 steam generator (SG) tube inspections at Vogtle Electric Generating Plant, Unit 2 (Vogtle 2). These inspections were performed during the twelfth refueling outage (2R12). In order to complete its review of the documents listed above, the Nuclear Regulatory Commission staff needs the following additional information:

1. For each refueling outage and steam generator tube inspection outage since the steam generators were placed in service, please provide the cumulative effective full power months the steam generator has operated.
2. Regarding the scope of examinations in the U-bend region of rows 1 and 2, please confirm that you have examined all of the tubes (in this region) prior to the completion of your current inspection period (presumably the 90 effective full power month period).
3. You indicated that the steam generators were chemically cleaned during your 2007 outage. Please discuss the results of the chemical cleaning.
4. Please discuss the scope and results of any secondary side inspections.
5. Please confirm that the one non-pluggable volumetric indication is the same volumetric indication that was reported in steam generator 2 in row 1 column 46. Please also confirm that the indication was attributed to wear and that the indication is non-pluggable because it did not exceed the tube repair criteria (rather than the tube could not be plugged). In addition, discuss the cause of the wear (e.g., interaction with cleaning equipment, etc.)

Vogtle Electric Generating Plant, Units 1 & 2 cc:

Mr. Tom E. Tynan Vice President - Vogtle Vogtle Electric Generating Plant 7821 River Road Waynesboro, GA 30830 Mr. N. J. Stringfellow Manager, Licensing Southern Nuclear Operating Company, Inc.

P.O. Box 1295 Birmingham, AL 35201-1295 Mr. Jeffrey T. Gasser Executive Vice President Southern Nuclear Operating Company, Inc.

P.O. Box 1295 Birmingham, AL 35201-1295 Mr. Steven M. Jackson Senior Engineer - Power Supply Municipal Electric Authority of Georgia 1470 Riveredge Parkway, NW Atlanta, GA 30328-4684 Mr. Reece McAlister Executive Secretary Georgia Public Service Commission 244 Washington St., SW Atlanta, GA 30334 Mr. Harold Reheis, Director Department of Natural Resources 205 Butler Street, SE, Suite 1252 Atlanta, GA 30334 Attorney General Law Department 132 Judicial Building Atlanta, GA 30334 Mr. Laurence Bergen Oglethorpe Power Corporation 2100 East Exchange Place P.O. Box 1349 Tucker, GA 30085-1349 Arthur H. Domby, Esquire Troutman Sanders Nations Bank Plaza 600 Peachtree Street, NE Suite 5200 Atlanta, GA 30308-2216 Resident Inspector Vogtle Plant 8805 River Road Waynesboro, GA 30830 Office of the County Commissioner Burke County Commission Waynesboro, GA 30830 Mr. Bob Masse Resident Manager Oglethorpe Power Corporation Vogtle Electric Generating Plant 7821 River Road Waynesboro, GA 30830