Survey Unit Release Record Design #
I EP-Rx 138-3 /
Revision ll I Original I Page I of 4 Survey Unit #(s)
Description
- 1) Embedded Pipe (EP) Survey Unit Rx 138-3 meets the definition of embedded pipe for Plum Brook Reactor Facility (PBRF).
- 2) EP Rx 138-3 is a Class 1, Group 1 survey unit as per the PBRF Final Status Survey Plan (FSSP) and Technical Basis Document (TBD)-06-004.
- 3) Surveys in EP Rx 138-3 were performed using a scintillation detector optimized to measure gamma energies representative of Co-60. Sample #EP 3-9 from Survey Request (SR)-13 was referenced for this decision.
- 4) Survey Instructions for this survey unit are incorporated into and performed in accordance with (IAW) the Babcock Services Incorporated (BSI)/LVS-002, Work Execution Package (WEP)05-006. Survey instructions described in this document constitute "Special Methods" and the survey design used in the acquisition of survey measurements.
- 5) Instrument efficiency determinations are developed in accordance with the BSILVS-002, WEP 05-006, these determinations are appropriate for the types of radiation involved and the media being surveyed.
- 6) Only the seven feet of the approximate overall length of twenty two feet of this pipe was accessible for final survey. However, it is concluded that the final survey of the accessible portion of this pipe system is appropriate to demonstrate the radiological condition of the entire pipe and the suitability of the pipe for unrestricted release.
Technical Reviewer FSSICharacterization Manager Approval Signatures Date:
FSS/Characterization Engineer fi-28 -0'7
FSS Design # EP Rx 138-3 Revision # Original Page 2 of 4 Survey Unit: Rx 138-3 1.0 History/Description 1.1 The subject pipe system is a 1 system line. The ends of the piping section are accessible from the Sub Pile Room and Quad D on the -25 elevation of the Reactor Building.
1.2 EP Rx 138-3 is approximately 22 feet in length. The middle portion of the pipe run could not be accessed for survey due to a series of mitered, 90o elbows that prevent the travel of radiological detectors past the access points. Consequently, only seven of the approximate 22 feet of total length for this pipe was accessible for survey.
2.0 Survey Design Information 2.1 EP Rx 138-3 was surveyed IAW Procedure #BSI/LVS-002.
2.2 The accessible portion of the 1 ID pipe was surveyed by static measurement at one foot increments, for a total of 7 survey measurements.
2.3 Surface area for the 1 ID piping is 243 cm2 for each foot of piping, corresponding to a total 1 ID piping surface area of 1,703 cm2 (0.2 m2) for the entire accessible length of (7) of 1 piping.
3.0 Survey Unit Measurement Locations/Data 3.1 Pipe interior radiological survey forms are provided in Attachment 2 of this release record.
4.0 Survey Unit Investigations/Results 4.1 None 5.0 Data Assessment Results 5.1 Data assessment results are provided in the EP/Buried Pipe (BP) Survey Report provided in Attachment 1.
5.2 Only the seven feet of the approximate overall length of 22 feet of this pipe was accessible for final survey.
5.3 All measurement results from the seven feet of accessible pipe are less than the Derived Concentration Guideline Level (DCGL) for radionuclide specific EP that corresponds to the 1 mrem/yr dose goal established in Table 3-3 of the FSSP.
5.4 Background was not subtracted from the survey measurements and the Elevated Measurement Comparison (EMC) was not employed for the accessible portion of this survey unit.
5.5 In addition to the seven final survey measurements taken in the accessible portion of this pipe, additional radiological surveys were performed to the extent possible as allowed by the configuration of this piping. These surveys were performed to provide additional assurance that the
FSS Design # EP Rx 138-3 Revision # Original Page 3 of 4 Survey Unit: Rx 138-3 radiological conditions represented by the seven interior survey measurements are representative of the entire length of pipe.
5.6 Scan surveys were performed for pre and post remediation purposes, using a beta-gamma GM detector on the exterior of the access point for this pipe system. The surveys are documented as survey nos. NASA-07-3204 and NASA-07-3221, performed in support of RWP PB-07-100. Both pre and post surveys showed negligible levels of activity. The scan survey results indicated activity <1,000 dpm per direct frisk. In addition, smear rag was pulled through the length of the piping section. No loose radiological contamination greater than 1,000 dpm/100cm2 was detected.
5.7 Based upon the results of the final survey measurements combined with the results of the operational survey, it is reasonable to conclude that the final survey of the accessible portion of this pipe system is appropriate to demonstrate the radiological condition of the entire pipe. Survey Unit EP Rx 138-3 demonstrates compliance with the DCGL values, as presented in Sections 3.3, 7.5 and Attachment C of the PBRF FSSP.
5.8 When implementing the Unity Rule, provided in Section 3.6.3 of the FSSP, and applying the Nuclide Fraction (NF), provided in TBD-06-004, the survey unit that is constituted by EP Rx 138-3 passes FSS.
Statistical Summary Table Statistical Parameter 1 Pipe Total Number of Survey Measurements 7
Number of Measurements >MDC 6
Number of Measurements Above 50% of DCGL 0
Number of Measurements Above DCGL 0
Mean 0.2290 Median 0.2832 Standard Deviation 0.1363 Maximum 0.3938 Minimum 0.0380 6.0 Documentation of evaluations pertaining to compliance with the unrestricted use limit of 25 mrem/yr and dose contributions from Embedded Pipe and radionuclides contributing 10% in aggregate of the total dose for both structural scenarios and soils.
FSS Design # EP Rx 138-3 Revision # Original Page 4 of 4 Survey Unit: Rx 138-3 6.1 A review of the survey results has shown that the dose contribution for the accessible portion of EP Rx 138-3 to be less than 1 mrem/yr. The dose contribution is estimated to be 0.229 mrem/yr based on the average of the actual gross counts.
7.0 Attachments - BSI EP/BP Survey Report -Pipe Interior Radiological Survey Form & Radiation Protection Survey Forms - DQA Worksheet -Disc containing RR for EP Rx 138-3 & Spreadsheet
SECTION 7 ATTACHMENT 1 z
PAGE(S)
BSI EPlBP SURVEY REPORT S u ~ e y Location DetectorSled #
PMT FO 1.5L-X Detector Efficiency Field BKGm)
Field MDCR,,)
Survey Unit Classification TED 06-004 Piping Group SR-13 Radionuciide Distribution Sample Measured Nuclide Area FactorIEMC Used PassIFail FSS MREMNR Contribution 1
1 EP 3-9 Co-60 No Pass c l COMMENTS:
ACTIVITY VALUES NOT BACKGROUND CORRECTED RP Engineer I Date
/
/i'-
1 p - 0 7
EP Rx 138-3 1" Pipe TBD 06-004 Group 1 Measurement #
gcpm ncpm Co-60 activity (total dpm)
Co-60 activity (dpm/100cm2)
Cs-137 activity (dpm/100cm2)
Eu-152 activity (dpm/100cm2)
Eu-154 activity (dpm/100cm2)
Nb-94 activity (dpm/100cm2)
Ag-108m activity (dpm/100cm2)
Unity 1
88 88 123,944 50,960 2,020 48,341 12,851 1,487 355 0.304 2
74 74 104,225 42,852 1,698 40,650 10,806 1,250 299 0.256 3
83 83 116,901 48,064 1,905 45,594 12,121 1,403 335 0.287 4
82 82 115,493 47,485 1,882 45,045 11,975 1,386 331 0.283 5
114 114 160,563 66,016 2,616 62,623 16,648 1,926 460 0.394 6
12 12 16,901 6,949 275 6,592 1,752 203 48 0.041 7
11 11 15,493 6,370 252 6,043 1,606 186 44 0.038 MEAN 0.229 MEDIAN 0.283 STD DEV 0.136 MAX 0.394 MIN 0.038 1 of 1
SECTION 7 ATTACHMENT 2 5-PAGE(S)
- BSIiZVSPippeCrawier4IfZ Revision 5 Pipe Interior Radi~logical Survey Farm W : i \\ ~ 7. 0 7
~ime:
1357 pipem*
R x 13f '3
~ip~ipenrameta:
1 "
~ ~ c c e s s ~ & b a : k M 0
, x
~~evation: -d6' Sy~em:
Typeaf S w
P+
r-,=
P ~ S t w q )( other ?/
@ass Co60 Cs Detectox I M F I &dm# &T ~ ; 3 1.5 L-X / 00471 ~J\\A
&tecter Caf Date:
q. M. 0 7 Detecm Gal Due Date:
- 4. HP Instmm&.
e 1 f#:
J0.34 68 wmnt Gal D*:
9 1447 Instnune~t Csf. Due Date:
q4 Vf.08 F-fhe Daily Pipe m y
Detector Cmtrol Form fbr fortha SeEected Detector Backgroundvalue 7.0 cpm ra.1~
cprn Efficiemcy Fxbr for Diameter 0 a00 7 1 (hmdetector efficimcy determination)
(ifnu, *s@e carmt trme andrmdcalar: MD-1 "Q",
9 a n A ID fi-~fi, 1
Technician Signature f
\\
Pipe InteFiQr Radiological Survey
- u.
REFERENCE COPY 1-1 Package Page 1 of 5, Page I
RADIATION PROTZMON SURVEY FORM
~-,
RADUTION PROTECTXON SURVEY FORM Pagelof )
re-005 11 Rev. 0 rl
SECTION 7 ATTACHMENT 3 I
PAGE(S)
FSSICharacterization Engineer (prinffsign)
CS-0912 Page 1 of 1
SECTION 7 ATTACHMENT 4 1 DISC