Report for Analysis of Four Water Samples from Set Four from the Indian Point Power Station, Buchanan, New York, Dtd October 15, 2007
ML073180148
Person / Time
Site: Indian Point 
Issue date: 10/15/2007
From: Condra D
Oak Ridge Institute for Science & Education
To: Kottan J
NRC Region 1
References
07-004, IR-07-003
Download: ML073180148 (6)


Text

October 15, 2007 O R I S E OAK RIDGE INSTITUTE FOR SCIENCE AND EDUCATION Mr. Jim Kottan US. Nuclear Regulatory Commission Region I 475 Allendale Road Icing of Prussia, PA 19406

SUBJECT:

REPORT FOR ANALYSES OF FOUR WATER SAMPLES FROM SET FOUR FROM THE INDIAN POINT POWER STATION, BUCHANAN, NEW YORK

[INSPECTION REPORT NO. 050-247/2007-0031 [RFTA NO. 07-0041

Dear Mr. Kottan:

The Oak bdge Institute for Science and Education (ORISE) received set four, consisting of four water samples associated with the Indian Point Power Station on August 14, 2007. Sample analysis was initiated based on the information in RFTA 07-004. Sample identification and collection data for the samples addressed in t h s report are presented in Table 1. Gamma spectroscopy, total rahostrontium, nickel-63, and tritium data are provided in Tables 2-5, respectively. The pertinent procedure references are provided in each specific table.

ORISEs Quality Control (QC) requirements were met for these analyses. The QC files are available for your review upon request.

My contact information is listed below. You may also contact Wade Ivey at 865.576.9184 with any questions or comments.

Sincerely, Dale Condra, Manager Laboratory RDC : WPI : b f Enclosures c:

T. Carter, NRC/FSME/DWMEP 7J8 J. Whte, NRC Region I E. Ibox-Davin, NRC/FSME/TWFN 8A23 E. Abelquist, ORISE File 1748 J. Commiskey, NRC Region I S. Roberts, ORISE Distribution approval and concurrence :

T e c h c a l Management Team Member Quality Manager Voice: 865.241.3242 Fax: 865.241.3248 E-mail: Dale.Condra @orau.org

TABLE 1 ORISE Sample ID SAMPLE IDENTIFICATIONS AND COLLECTION DATA INDIAN POINT POWER STATION BUCHANAN, NEW YORK NRC Region I Collection Sample ID Time Collection Date 1748W0023 1748W0024 Mw-63-18-(002) 7/30/2007 13:lO Mw - 6 3 -3 4- (0 02) 7/30/2007 13:28 11 1748W0025 I Mw-66-21-(001) I 7/30/2007 I

13:45 11 1748W0026 I Mw-66-36-(001) 1 7/30/2007 I

12:49 Indian Point Power Station projects/ 1748/Data Tables/ 1748-DT-004-0

TABLE 2 ORISE NRC Region I Sample ID Sample ID 1748W0023 m-63-18-(002) 1748W0024 MW-63-34-(002) 1748W0025 MW-66-21-(001) 1748W0026 MW-66-36-(001)

Radionuclide Concentrationsa (pCi/L) co-58 co-60 cs-134 cs-137

-0.1 i-2.9

, 4.2 0.9 k 2.2, 3.9 3.0 k 2.6, 4.0 0.4 i-2.2, 3.7

-0.1 k 1.8, 3.0 1.1 i-1.7, 3.0 0.7 t-1.7, 3.0 3.0 k 2.1, 2.1

-0.1 I 2.8, 4.3 -1.1 & 2.4, 4.1

-1.3

& 3.0, 4.1 0.1

& 2.2, 3.8 0.3 I 2.8, 4.7 1.5 2 2.4, 4.2 2.3

& 2.6, 4.5 -0.9 & 2.3, 3.8 b

TABLE 3 ORISE Sample ID 1748W0023 1748W0024 1748W0025 1748W0026 CONCENTRATIONS OF TOTAL RADIOSTRONTIUM IN WATER SAMPLES BY LOW BACKGROUND BETA COUNTING AP4, REVISION 14; CP3, REVISION 2 INDIAN POINT POWER STATION BUCHANAN, NEW YORK Radionuclide Concentrations, TPUs, and MDCS" (pCi/L)

NRC Region I Sample ID MW-63-18-(002) 1.12 0.49b, 0.72 m-63-34-(002) 0.55 0.47, 0.77 m-66-21-(001) 2.19 k

0.56, 0.71 Mw-66-36-(001) 6.91

?

0.81. 0.71 "The MDCs are after the comma.

buncertainties represent the 35% confidence level, based on total propagated uncertainties.

Indian Point Power Station projects/l748/Data Tables/1748-DT-004-0

TABLE 4 CONCENTRATIONS OF NICKEL43 I N WATER SAMPLES BY LIQUID SCINTILLATION ANALYSIS AP12, REVISION 6; CP4, REVISION 3 INDIAN POINT POWER STATION BUCHANAN, NEW YORK Indian Point Power Station projects/l748/Data Tables/1748-DT-004-0

TABLE 5 ORISE Sample ID 1748W0023 1748W0024 1748W0025 1748W0026 BJ NRC Region I Radionuclide Concentrations, Mw-63-1 S-(002) 210 k

150b 250 Mw-63-34-(002) 390 k

160 250 Mw-66-21-(001) 3,640 k

300 250 Mw-66-36-(001) 9,310 k

520 250 Sample ID TPUs, and MDCS" (pCi/L)

CONCENTRATIONS OF TRITIUM I N WATER SAMPLES LIQUID SCINTILLATION ANALYSI AP2, REVISION 16; CP4, REVISION 3 INDIAN POINT POWER STATION BUCHANAN, NEW YORK Indian Point Power Station projects/l748/Data Tables/1748-DT-004-0