ML072840334

From kanterella
Jump to navigation Jump to search
Reports for Analysis for Samples from Set Twenty-Six from the Indian Point Power Station, Buchanan, New York. Dtd. August 1, 2007
ML072840334
Person / Time
Site: Indian Point 
Issue date: 08/01/2007
From: Condra D
Oak Ridge Institute for Science & Education
To: Kottan J
NRC Region 1
References
RFTA 07-001 IR-07-003
Download: ML072840334 (4)


Text

OAK RIDGE INSTITUTE FOR SCIENCE AND EDUCATION August 1,2007 Mr. Jim I<ottan U.S. Nuclear Regulatory Commission Region I 475 Allendale Road IOng of Prussia, PA 19406

SUBJECT:

REPORT FOR ANALYSES FOR SAMPLES FROM SET TWENTY-SIX FROM THE INDIAN POINT POWER STATION, BUCHANAN, NEW YORK

[INSPECTION REPORT NO. 050-247/2007-0031 [RFTA NO. 07-0011

Dear Mr. Kottan:

The Oak Ridge Institute for Science and Education (ORISE) received set 26, consisting of 11 water samples, associated with the Indian Point Power Station on May 21, 2007. Sample analysis was initiated based on your previous direction for handling samples from this licensee and modified based on a phone conversation with John \\%te on July 3,2007 and an e-mail from Stacie Sakai on July 9, 2007. Sample identification and collection data for the samples addressed in t h s report are presented in Table 1.

Gamma spectroscopy and tritium data are provided in Table 2 and Table 3, respectively. The pertinent procedure references are provided in each specific table.

ORISE's Quality Control (QC) rrquircmcnts were met for these analyscs. The QC files are avdable for your review upon request.

My contact information is listed below. You may also contact Wade Ivey at 865.576.9184 with any questions or comments.

Sincerely, Dale Condra, Manager Laboratory RDC:\\VPI:bf Enclosures c:

T. Carter, NRC/FSME/DUIWEP 7J8 J. \\Xhm, NRC Region I E. Knox-Davin, NRC/FSME/'TWFN 8A23 S. Roberts, ORISE File 1697 E. Abelquist, ORISE Distribution approval and concurrence :

'l'cchnical Management 'l'cam blrmber Quality Managcr I

1 Initials

- d*

Voice: 865.241.3242 Fax: 865.241.3248 E-mail: Dale.Condra @orau.org

TABLE 1 SAMPLE IDENTIFICATIONS AND COLLECTION DATA INDIAN POINT POWER STATION BUCHANAN, NEW YORK Collection Date Indian Point Purer Srauon

TABLE 2 ORISE NRC Region I Sample ID Sample ID 1697W0154 MW-62-55'-(001)

CONCENTRATIONS OF SELECTED GAMMA EMITTING RADIONUCLIDES IN WATER SAMPLES BY GAMMA SPECTROSCOPY CP1, REVISION 15 INDIAN POINT POWER STATION BUCHANAN, NEW YORK Radionuclide Concentrations, TPUs, and MDCs" (pCi/L) co-58 CO-60 cs-l34 cs-l37 0.1 ? 2.4b, 4.1 0.7 f 2.1. 3.7 2.5 f 2.2, 3.8 -1.8 f 3.6. 4.1 1697W0156 1697\\7c'0157 1697W0158 (I 1697W0155 1 MW-62-73'-(001) 1 0.4 t 3.0, 4.4 I -0.9 2 2.6, 4.2 1 1.3 f 2.8, 4.2 1 1.9 f 2.2, 3.9 )I MW-62-94'-(001)

-1.1 f 2.9, 4.3 1.3 f 2.3, 4.1 0.1 2 2.3, 4.0 0.7 f 2.3, 3.7 hIW-62-140'-(001) 0.9 f 1.9, 3.4 0.6 f 2.0, 3.1 1.5 f 2.0, 3.1 0.1 2 1.6, 2.9 Mw-62-184'-(001)

-0.3 f 2.8, 4.6 -0.1 f 2.5. 4.3

-1.0 f 2.6. 4.3 2.1 f 2.3. 4.0 1697W0160 1697W0161 1697W0162 I( 1697W0159 I MW-63-52'-(001) I 0.0'

? 2.3, 3.8 1 -0.1 f 2.1, 3.71 2.3 f 2.3, 4.01 -3.1 t 3.6, 4.0 1)

MW-63-93'-(002)

-1.4 f 2.5, 4.1 2.1 2 2.7, 4.3 1.3 t 2.5, 4.3

-0.5 f 2.1, 3.6 MW-63-114'-(001) 0.6 f 1.9, 3.3 -0.3 ? 1.7, 3.0 0.0 f 1.8, 3.1

-0.3 f 1.7, 2.9 MW-63-124'-(001) 1.6 f 2.6. 4.2 0.7 f 2.2. 3.9 0.8 f 2.3. 3.5 -4.1 f 3.6. 4.0 1697W0164 1 MW-63-176'-(001) I 0.3 i 2.8, 3.0 1-0.5 f 1.7, 2.9

~

(1 1697W0163 1 MW-63-164'-(001) 1 3.8 2 2.9, 4.8 1 1.2 t 2.5, 4.41 0.1 f 3.0. 4.37 0.7 f-2.2 3.9 11 0.9 f 1.8, 3.2 0.2 f 1.7, 2.9

TABLE 3 1697W0156 1697W0157 1697W0158 CONCENTRATIONS OF TRITIUM I N WATER SAMPLES BY LIQUID SCINTILLATION ANALYSIS AP2, REVISION 16, CP4, REVISION 3 INDIAN POINT POWER STATION BUCHANAN, NEW YORK ORISE NRC Region I Concentrations, Sample ID Sample ID TPUs, and MDCS" 1697W0154 Mw-62-55'-(001) 340 k 180b, 28(

Mw-62-94'-(001) 430

-t 180, 2%

MW-62-140'-(001) 410 i 180, 2%

MW-62-184'-(001) 430

? 180, 28(

11 1697W0155 1

MW-62-73'-1001) 1 500 i-180. 28(

11 1697W0159 1

Mw-63-52'-1001) 1 390 k 180. 28(

11 1697W0160 I MW-63-93'-(002) 1 270 k

170, 28(

I MW-63-114'-(001)

I 390

+_

180, 28C 1697W0162 I MW-63-124'-(001) I 630

?

190, 2%

11 1697W0163 1

MW-63-164'-(001) I 590

_+

190, 28C Ind,.n h i n t Po\\r-cr Station