September 2007 Evidentiary Hearing - Intervenors Exhibit a, List of Exhibits
ML072830317
Person / Time
Site: Oyster Creek
Issue date: 09/25/2007
From:
- No Known Affiliation
To:
Office of Nuclear Reactor Regulation
SECY RAS
References
50-219-LR, AmerGen-Intervenor-A, RAS 14296
Download: ML072830317 (7)


Text

RtlS

/1ý 9%

CITIZENS' EXHIBIT A No.

Exhibit 1

GPU Nuclear, Drywell Steel Shell Plate Thickness Reduction (July 21, 1995).

2 Partial Cross Section of Drywell and Torus.

3 Memorandum from Peter Tamburro on the Unclear Documentation of Calculation C-1302-187-5320-024 (AR 00461639 Report) (Mar. 3, 2006).

4*

Exelon Nuclear, Calculation C-1302-187-5320-024 Revision 1: O.C. Dry~well Ext. UT Evaluation in Sandbed (Sept. 21, 2006).

NOTE: Intentionally omitted, submitted by AmerGen at Applicant Exh. 18.

5*

Exelon Nuclear, Calculation C-1302-187-E310-041 Revision 0: Statistical Analysis of Drywell Vessel Sandbed Thickness Data 1992, 1994, 1996, and 2006 (Dec. 15, 2006).

NOTE: Intentionally omitted, submitted by AmerGen at Applicant Exh. 20.

6 Affidavit of Peter Tamburro, Mar. 26, 2007.

7 AmerGen, NRC Information Request: Audit Question Numbers AMP-141, 210, 356 (Apr. 5, 2006).

8*

AmerGen, Passport 00546049 07 (AR A2152754 E09): Water Found in Drywell Trench 5 - UT Data Evaluation (Nov. 7, 2006).

NOTE: Intentionally omitted, submitted by AmerGen at Applicant Exhi. 19.

9 Structural Integrity Associates, Inc., Statistical Analysis of Oyster Creek C-o 'L(

mlbffi OllflcWEdbto C

l5'6.

by: Applicant/Licens a

.I_

r e-N Other IDNMB "IfWO 2.J7$L

Lfle~sIPaflel A114-Acon1~ken:

ME R~lE.ATM-j M(THDRAWAI DOCKETED USNRC October 1, 2007 (10:45am)

OFFICE OF SECRETARY RULEMAKINGS AND ADJUDICATIONS STAFF P I rzte = se 6 /- C) a s--

5,6 CY- 0,A-

Drywell Thickness Data (Jan. 4, 2007).

10 AmerGen, NRC Information Request: Audit Question Numbers AMP-357, 356, 210 (Jan. 24, 2006 and Feb. 16, 2006).

11 Email from Peter Tamburro to Ahnmed Ouaou (June 8, 2006).

12 Memorandum from Dr. Rudolf Hausler, Apr. 25, 2007.

Note: Identical to Attachment 2 to Dr. Hausler's Initial Testimony.

13 Memorandum from Dr. Rudolf Hausler, July 18, 2007.

Note: Identical to Attachment 3 to Dr. Hausler's Initial Testimony.

14 AmerGen, Reference Material to the ACRS: Photograph of the Sand Bed Region (1992).

15 Transcript of Nuclear Regulatory Commission Proceedings, Advisory Committee on Reactor Safeguards Subcommittee on Plant License Renewal Oyster Creek Generating Station (Jan. 18, 2007) (Excerpted Pages: p. 1-10, p. 132-144, p.207-224,

p. 353-358).

16 Transcript of Nuclear Regulatory Commission Proceedings, Advisory Conmmittee on Reactor Safeguards Meeting of Plant License Renewal Subcommittee (Oct. 3, 2006) (Excerpted Pages: p.1-8, p.59-63).

17 Email from Steven Hutchins to John Huffiagel Jr., with Drywell White Papers attachment (Sept. 18, 2006, 16:51 EST).

18 Affidavit of Jon R. Cavallo, Mar. 26, 2007.

19 AmerGen, Action Request: Determine the Proper Sealant for Drywell Sandbed Floor Voids (Oct. 25, 2006).

20 Letter from Richard J. Conte, Chief Engineering Branch 1, Nuclear Regulatory Commission, to Richard Webster, Esq., Rutgers Environmental Law Clinic (Nov. 9, 2006).

21 Letter from J.C. Devine, Jr., Vice President of Technical Functions, GPU Nuclear, to the Nuclear Regulatory Commission (Dec. 5, 1990)

(Attachment 3; GPUN Detailed Suimmary Addressing Water Intrusion and Leakage Effects Related to the Oyster Creek Drywell).

22 GPU Nuclear, Clearing of the Oyster Creek Drywell Sand Bed Drains (March 3, 1989).

23 AmerGen, Disclosed Document Relating to Drywell Leakage (Ref. # OCLR00013354).

24 Transcript of Nuclear Regulatory Commission Proceedings, Advisory Committee on Reactor Safeguards 539th Meeting (Feb. 1, 2007)

(Excerpted Pages: p.1-3, p. 172-177, p. 217-224).

25 Letter from the Nuclear Regulatory Commission to C. Crane (Jan. 17, 2007)

("Inspection Report").

26 Email from Steven Dunsmuir, FIN/Operations RO, Exelon Corp., to Howie Ray, et al. (Oct. 22, 2006, 04:52 EST).

27 Email from Tom Quintenz to Kevin Muggleston, et al. (Feb. 1, 2006, 17:02 EST).

28 GPU Nuclear, Evaluation of February 1990 Drywell UT Examination Data (Apr. 18, 1990).

29 Affidavit of Barry Gordon, Mar. 26, 2007.

30 Letter from Jill Lipoti, Director Division of Environmental Safety and Health, New Jersey Dept. of Environmental Protection, to Dr. Pao-Tsin Kuo, Director Division of License Renewal, U.S.

Nuclear Regulatory Commission (Apr. 26, 2007).

31*

AmerGen, Calculation Sheet C-1302-187-5300-01 1.

NOTE: Intentionally omitted, submitted by AmerGen at Applicant Exb. 23.

32*

GPU Nuclear, Calculation Sheet C-1302-187-5320-024 Revision 0: Oyster Creek Drywell Exterior Evaluation in Sandbed (Apr. 16, 1993)

NOTE: Intentionally omitted, submitted by AmerGen at Applicant Exh. 17.

33*

Exelon Nuclear, Calculation C-1302-187-5320-024 Revision 2: O.C.

Drywell Ext. UT Evaluation in Sandbed (Mar. 18, 2007).

NOTE: Intentionally omitted, submitted by AmerGen at Applicant Exh. 16.

34*

ACRS Information Packet (Dec. 8, 2006).

NOTE: Intentionally omitted, submitted by AmerGen at Applicant Exh. 3.

35 Letter from AmerGen to the NRC (2103-06-20426) (Dec. 3, 2006)

(Excerpted Pages: Dec. 3, 2006 Letter, p. 1-3, p. 9-15, p. 17-24).

36 Email from Caroline Schlaseman, MPR Associates, Inc. to Howie Ray & Jim Nestell (Nov. 2, 2006), contained within E-mail from Barry Gordon to Howie Ray et al. (Nov. 2, 2006).

37 Background and Statement of Facts (July 20, 2007)

Note: Identical to Attachment 5 to Dr. Hausler's Initial Testimony.

38 Memorandum from Dr. Rudolf Hausler,

Subject:

Response To The Questions About Statistics (Aug. 16, 2007).

Note: Identical to Attachment 2 to Dr. Hausler's Rebuttal Testimony.

39 Memorandum from Dr. Rudolf Hausler,

Subject:

Further Discussion of the Nature of the Corroded Surfaces and The Residual Wall Thickness of the Oyster Creek Dry Well (Aug. 16, 2007).

Note: Identical to Attachment 3 of Dr. Hausler's Rebuttal Testimony.

40 Email from William Russell to Frederick Polaski, et al.,

Subject:

Challenge Board #1 additional comment (Nov. 30, 2006, 9:48 EST), attached to email from John Hufnagel Jr. to Atuned Ouaou, et al. (Nov. 30, 2006 10:41 EST).

41 GPU Nuclear, Technical Functions Safety/Environmental Detennination and 50.59 Review (Jan. 5, 1993).

42 Email from Peter Tamburro to Ahmed Ouaou, Cc Howie Ray, et al.,

Subject:

Surface Are (sic) of the Drywell in the sand bed (Apr. 3, 2006 3:24 PM).

43 Email from John O'Rourke to Michael Gallagher, et al.,

Subject:

External Inspections of DW in Sandbed Region (Oct. 10, 2006 8:08 AM), attached to'email from John Hufnagel to John O'Rourke (Oct. 10, 2006 8:10 AM).

44 Memorandum, GPU Nuclear from K. L. Whitmore, Civil/Structural Mgr. to J. C. Flynn, Manager, Special Projects, Engineering Projects,

Subject:

Inspection of drywell sand bed region and access holes (Jan. 28, 1993).

45 AmerGen Technical Evaluation 330592-27-27 (Apr. 20, 2007).

46 Email from John O'Rourke to Marcos Herrera, Cc Michael Gallagher et al.,

Subject:

Oyster Creek Drywell Thickness to be Used for Base Case Analysis, with OYSTER CREEK DRYWELL THICKNESSES, Rev2.doc attachinent (Feb. 28, 2007 7:20 PM).

47 Issue # 005571.80, Exelon Nuclear Issue - Statement of Confirmation, Originator: Kathy Barnes (Nov. 13, 2006).

48 Email from Tom Quintenz to John O'Rourke,

Subject:

Notes of video inspection results of trough area with Video Inspection of Concrete Trough Notes November 1996 with attachment (Oct. 10, 2006 2:26 PM).

49 GPU Nuclear, Material Nonconformance Report (Oct. 27, 1986).

50 Memorandum, GPU Nuclear from R. Miranda, Engineer, Technical Functions to Distribution,

Subject:

14R Reactor Cavity Leak Detection Effort (Feb. 1, 1993).

51 Sketches showing ultrasonic and "Echo to Echo" techniques, and explanations of sketches (OCLR00026641).

52 E-mail from Tom Quintenz to Ahmned Ouaou & John Hufnagel, Jr. (September 20, 2006 2:02 EST)

AR 00547236 Report

53.

Letter from Alexander W. Dromerick to John J. Barton (November 19, 1991) 54 Letter from Alexander W. Dromerick to John J. Barton (September 2, 1993) 55 Memorandum from Goutam Bagchi for John F. Stolz dated April 9, 1992, with attached Safety Evaluation Report with supporting analysis by Brookhaven National Laboratories 56 Letter from Alexander W. Dromerick to John J. Barton (April 24, 1992)

57 Letter from J.C. DeVine to NRC (May 26, 1992) 58 Letter from Alexander W. Dromerick to John J. Barton (June 30, 1992) 59*

Letter from H.S. Mehta to Dr. Stephen Tumminelli (December 11, 1992)

NOTE: Intentionally omitted. Submitted by AmerGen at Applicant Ex. 39 60 Sandia Report on Structural Integrity Analysis of the Degraded Drywall Containment. of Oyster Creek Nuclear Generating Station (Jan. 2007) (SAND2007-0055)

NOTE: Portions intentionally omitted; only included pages 77-85. Other relevant pages submitted by NRC Staff 61 Memorandum from Rudolf H. Hausler to Richard Webster, Esq.,

Subject:

Further Discussion of the External Corrosion on the Drywall Shell in the Sandbed Region (September 13, 2007) 62 Transcript excerpt from the Official Transcript of Proceedings, Nuclear Regulatory Commission -

Advisory Committee on Reactor Safeguards, http://www.nrc.,ov/readiingv-mn/doc-collections/acrs/tr/fullconmiittee/2001 /ac01 0906.1itml (last visited Sept. 13, 2007) (transcript excerpt from the 4 8 5 th Meeting held on September 6, 2001) 63 Diagram of Oyster Creek Lower Drywall/Sandbed Region. NOTE: Intentionally omitted. Submitted by AmerGen at Applicant Ex. 7.

64 E-mails ending in e-mail from Gordon to Licina, dated October 24, 2006 (redacted to be non-proprietary) 65 E-mail from O'Rourke to Herrera, dated February 7, 2007 (redacted to be non-proprietary)