DOCKETED USNRC October 1, 2007 (10:45am)
OFFICE OF SECRETARY RULEMAKINGS AND ADJUDICATIONS STAFF APPLICANT'S EXHIBIT 44 U.S. WUCE REULATORY COMMISSION In theMawa ~5D-&r F,j~ CD~. Lto Docket 14052 121 9-1U.
OftIc~aI EXhIbitNo.'4A OFFERED by-PIanLiensee Intervenor ADENTIFIED on TaWitness/Panel ITDR ActoionTaken:
ADtE,,JCE WITHDRAWN Bay 1 - 2006 Spatial Relationship Of Internal Grids and External Locally Thin Areas Inches
-72
-60
-48
-36
.24
-12 12 24 46 48 60 72 "6
A Grid ID This 36" b 36" (average 1122 Cm A m Criteria Tray Area mils In 2006) A m" m, A
" Point 5 A
(680 mils In 2006)
A AA
- -42 ALN A
Squares are less than 0.736" Triangles are greater then 0.736".
-s6Cy-0oL.
Bay 13-2006 Spatial Relationship Of Internal Grids and External Locally Thin Areas Inches r
4
-72
-60
-4 Grid 13D (average Top 1047, Bottom 904, All 968 In 2006) 8 B
-24
-.12 i
8 U,
a, U
Point 15 (666 mils In 2006)
AE N
U LA
-3 Grid 13C (average 1142 mils in 2006)
A A
48 60 72 A
A A
A, I
0 A
Grid 13A (average 846 mils in 2006) 7 Y This. 36" b 36" Criteria Tray Area Squares are less than 0.736" Triangles are greater then 0.736"
Bay 17-2006 Spatial Relationship Of Internal Grids and External Locally Thin Areas Inches U
5
-83
-71
-59 Grid 17D (average 819 mils In 2006)
-47
-35
-23
-11 6-1 A
6-13 25 37 49 61 73 85 Point 2 (663 mils In 2006)
A 0
(A-c Grid 17-19 (average Top 964, Bottom 972, All 969 in 2006)
I A N A
-30 A This 36" b 36" Criteria Tray Area Grid 17A (average Top 1122, Bottom 935, All 1015 In 2006)
Squares are less than 0.736" Triangles are greater then 0.736"
Bay 19 - 2006 Spatial Relationship Of Internal Grids and External Locally Thin Areas Inches
-72
-60
-4a
-2
-24
-12 12 24 A,t0 Grid 19C Grid 19B (average 824 (average 848 mils in 2006) mils In 2006)
-10 9
11 728 Mils A
712 MIs
-34 A